Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAdmitted-Finance | ₹15.8 L | L1 | Admitted-Finance |
| 2 | L2₹16.2 L+₹37,239.10 (2.35%)Admitted-Finance | ₹16.2 L+₹37,239.10 (2.35%) | L2 | Admitted-Finance |
| 3 | L3₹16.6 L+₹75,665.10 (4.78%)Admitted-Finance | ₹16.6 L+₹75,665.10 (4.78%) | L3 | Admitted-Finance |
| 4 | L4₹16.7 L+₹88,549.10 (5.59%)Admitted-Finance SAINIK COLONY JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹16.7 L+₹88,549.10 (5.59%) | L4 | Admitted-Finance |
| 5 | L5₹18.4 L+₹2.6 L (16.1%)Admitted-Finance | ₹18.4 L+₹2.6 L (16.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Malik Brothers Electrical Contractor and Suppliers L1 | Daya Krishan Raina L2 | Rajinder Singh L3 | R S ELECTRIC INFRA L4 | MOHD SHAFI NATNOO L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Creation of 1x25 KVA Distribution Substations at Washi on Bhagwah Feeder. ( All items are SITC) | ||||||||
| 1.00 | 11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors and with LV Cable Box having detachable Aluminium Gland Plate Energy Level-2 , as per amendment 4 of IS 1180-2014 (Aluminium wound) | 1 | No | 75,000 ₹75,000 Lowest | 1,10,000 ₹1,10,000 | 1,20,000 ₹1,20,000 | 1,10,000 ₹1,10,000 | 1,10,000 ₹1,10,000 |
| 1.00 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | 2,500 ₹2,500 Lowest | 7,000 ₹7,000 | 6,000 ₹6,000 | 4,500 ₹4,500 | 3,600 ₹3,600 |
| 1.00 | 11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm | 1 | Set | 7,000 ₹7,000 | 8,000 ₹8,000 | 7,500 ₹7,500 | 5,500 ₹5,500 Lowest | 8,100 ₹8,100 |
| 1.00 | 11 kV D O Fuse Set 3 Phase 200A | 1 | Set | 3,500 ₹3,500 | 7,000 ₹7,000 | 6,000 ₹6,000 | 3,000 ₹3,000 Lowest | 3,600 ₹3,600 |
| 1.00 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type | 35 | Mtr | 100 ₹3,500 Lowest | 180 ₹6,300 | 120 ₹4,200 | 150 ₹5,250 | 320 ₹11,200 |
| 1.01 | 9 Mtr. Long Pole( ST-410 SP33) | 2 | Nos | 22,000 ₹44,000 | 17,500 ₹35,000 Lowest | 18,500 ₹37,000 | 21,000 ₹42,000 | 21,000 ₹42,000 |
| 1.01 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 3 | Nos | 250 ₹750 | 600 ₹1,800 | 450 ₹1,350 | 200 ₹600 Lowest | 320 ₹960 |
| 1.01 | GI Channel/Angle/Flat of sizes including clamps | 230 | Kgs | 110 ₹25,300 Lowest | 170 ₹39,100 | 180 ₹41,400 | 130 ₹29,900 | 142 ₹32,660 |
| 1.01 | Aluminium Thimble 95 Sq. mm | 12 | Nos | 50 ₹600 | 50 ₹600 | 40 ₹480 | 15 ₹180 Lowest | 28 ₹336 |
Tender Value
₹19.7 L
EMD Value
₹39,500
Closing Date
25 Aug 2025, 4:00 pmClosed
XEN ED Doda
ED DODA
Creation of 1x25 KVA Distribution Substations along with HT LT network at Washi on Bhagwah Feeder
2025_PDD_283562_1
ED Doda/JPDCL/20 of 2025-26
Open Tender
Electrical Works
Turn-key
60 days
ED DODA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
XEN ED-Doda
₹39,500
8 Sept 2025
7 Aug 2025
26 Aug 2025
7 Aug 2025
25 Aug 2025
8 Aug 2025
Amount
Creation of 1x25 KVA Distribution Substations at Washi on Bhagwah Feeder. ( All items are SITC)
11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors and with LV Cable Box having detachable Aluminium Gland Plate Energy Level-2 , as per amendment 4 of IS 1180-2014 (Aluminium wound)
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
11 kV D O Fuse Set 3 Phase 200A
95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Aluminium Thimble 95 Sq. mm
Aluminium Bus Bar
Aluminium Paint
Busbar Insulator
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Galvanized Nuts and Bolts.
Earthing of substation complete
Laying of HT Network for 1x25 KVA Distribution Substation at Washi on Bhagwah Feeder. ( All items are SITC)
8 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasel
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Network for the dispersal of power supply of 1x25 KVA newly created Distribution Substations at Washi on Bhagwah Feeder . (All items are SITC)
8 mtr. Long Pole(ST-410, SP15)
GI Mucky-Clamps for Shackle Insulators
30 mm² ACSR Weasel Conductor
16kN Polymer Shackle Insulators
Galvanized Nuts and Bolts.
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Daya Krishan Raina (BID ID -2445007)
Rajinder Singh (BID ID -2454251)
R S ELECTRIC INFRA (BID ID -2454059)
MOHD SHAFI NATNOO (BID ID -2441697)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .