| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.1 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.2 L+₹7.5 L (30.5%)Rejected-AOC RZ 17B STREET NO 30 INDIRA PARK PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L-2 | Rejected-AOC L-2 | |
| 3 | Rejected-Technical | - | Rejected-Technical No, not enlisted in eligible category | |
| 4 | Rejected-Technical H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | - | Rejected-Technical No, Slow progress in WLR for QE Jun 2022 vide HQ CE WC letter No. 37940/WLR/D to S/QE Jun 2022/33/E8 dt 19 Oct 2022. | |
| 5 | Rejected-Technical III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | - | Rejected-Technical No, Slow progress in WLR for QE Mar 2022 vide HQ CE CC letter No. 980804/4/WLR/QE Mar 2022/33/E8 dt 31 Aug 2022. |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
29 Oct 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR MAINT OF VARIOUS LIFTS AND CONNECTED WORKS AT KWC AREA AND M HOUSE AREA UNDER GE I RND DELHI
2022_MES_555634_1
GE/RND-61/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D cat c (ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹66,000
Yes
14 Dec 2022
1 Oct 2022
1 Nov 2022
1 Oct 2022
29 Oct 2022
17 Oct 2022
Amount
S&F in replacement of unserviceable lift car door operator as per existing make including all connected accessories complete all as specified and directed.
S&F in replacement of UPS with complete accessories for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 3 KVA complete all as specified and directed.
S&F in replacement of ARD Battery for lifts 12 Volts 7 AH complete all as specified and directed.
S&F in replacement of ARD battery of batteries 12 volts 18 AH including all connected accessories complete all as specified and directed.
S&F in replacement of SWR Rope 10/12 mm dia & Existing length for lifts complete all as specified and directed.
Material and Labour in repair for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25X4 mm by means of nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25 mm x 4 mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated materials n. exc 50m and depositing where directed including taking out old unserviceable compete all as specified and directed.
Material and Labour in repair for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4 mm dia by means of Copper nuts, bolts and washers. GI wire laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI wire of size 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
S&F GI Wire 4mm dia for connecting earthing including taking out old unserviceable complete all as specified and directed.
S&F in replacement of lift car fan metalic body 16-30 W suitable to match with existing fan's RPM and sweep installed in the lifts of make Evaan/ThyssenKrupp/Johnson/OTIS/ Shindler/Omega with complete accessories all as specified and directed.
S&F in replacement of lift siren suitable for make of lift Evaan/ThyssenKrupp/Johnson/ OTIS/ Shindler/Omega as per OEM make with complete accessories all as specified and directed.
S&F in replacement of LOP ( Lift operating panel) as per OEM make of lift Evaan/ThyssenKrupp/Johnson/OTIS/Shindler/Omega with complete accessories all as specified and directed.
S&F in replacement of LOP up down button as per OEM make of lift Evaan/ThyssenKrupp/Johnson/OTIS/Shindler/Omega with complete accessories all as specified and directed.
S&F in replacement of lift light LED type rod/down lighter installed in the make of lift Evaan/ThyssenKrupp/Johnson/OTIS/Shindler/Omega with complete accessories all as specified and directed.
S&F in repair of car green mat of size 4'x4' as per existing complete all as specified and directed.
S&F in replacement of unserviceable ARD ( automatic rescue device) card including all connected accessories suitable for make of lifts Evaan/ThyssenKrupp/Johnson/OTIS /Shindler/Omega complete all as specified and directed.
S&F in replacement of Base Module TR IND AEs Bionic 5.4 supply Module TR for TR controller including all connected accessories suitable for shindler make lift serving for G+5 floor of capacity 10 pers (680 Kgs) complete all as specified and directed.
Supply, Fixing, testing and commissioning of following spare parts through OEM for lift of capacity 08 passangers (Ground + 5 floors) installed at ISSA Building Make - OTIS in M'House including taking down old unserviceable parts complete all as specified and directed. (a) Connecteur Male 6 pins Phoenix - 02 Nos (b) Drive LEDD W/3W Interface - 02 Nos (c) Interconnection-FAA24350DA1 - 02 Nos (d) Power Supply Block LEDO - 02 Nos (e ) Cable for LEDD - 02 Nos (f ) Electromagnetic Interface Shield - 02Nos (g) SMPS MTG Bracket - 02Nos (h ) Cable for LEDD - 02Nos
sumit associates
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .