| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC 37 4TH CROSS ASHWATHNAGAR SANJYANAGAR POST BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.3 L+₹2.4 L (7.88%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.8 L+₹2.9 L (9.52%)Rejected-AOC NO 228 3RD CROSS HRBR 3RD BLOCK NEAR JALVAYU VIHAR WEST GATE BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹34.5 L+₹4.6 L (15.3%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹39.5 L+₹9.6 L (32.0%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
17 Jun 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR/REPLACEMENT OF LT UG CABLE/LT OUTDOOR PANELS,MAINTENANCE TO E/M INSTALLATION /SUBSTATION,DG SET INSTALLATION AND CONNECTED WORKS AT HQTC BANGALORE
2024_MES_655040_1
8217/GE
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹90,000
30 Aug 2024
20 May 2024
24 Jun 2024
20 May 2024
17 Jun 2024
3 Jun 2024
21 May 2024 - 27 May 2024
Amount
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed by Engineer-in-Charge. Note- Punned thickness of sand i.e 18 cm to be consider for measurement purpose.
Supplying and laying un-reinforced precast concrete cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation,filling and mass concrete in foundation of poles and stay assembly for bed concrete or as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation,filling and mass concrete in foundation of stay assembly and pole or as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessary plastering work complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittings and pipes etc complete all as specified and directed.
Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
All as per item No-10.00 here-in-before but of size 10 sqmm 4 core.
All as per item No-10.00 here-in-before but of size 16 sqmm 4 core.
All as per item No-10.00 here-in-before but of size 25 sqmm 4 core.
All as per item No-10.00 here-in-before but of size 35 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 50 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 70 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 95 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 120 sqmm 3.5core.
All as per itemNo-10.00 here-in-before but of size 185 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 240 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 300 sqmm 3.5core.
Dismantling of unserviceable/damaged MCB/MCCB of any type/size and removal from site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 125 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 315 Amps,50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 400 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 500 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 630 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB TPN 63A "C" curve, 415V,10KA 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Dismantling and taking out old existing unserviceable/damaged/burnt change over switch 4 pole of capacity 125 Amp to 600 Amp 50 Hz 415 Volt any make,any capacity complete all as specified & directed by Engineer-in-Charge.
Supply and Install in replacement on load Changeover switch in existing LT panel 415 Volt in open execution 4 pole of capacity 125 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Supply and Install in replacement on load Changeover switch in existing LT panel 415 Volt in open execution 4 pole of capacity 160 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Supply and Install in replacement on load Changeover switch in existing LT panel 415 Volt in open execution 4 pole of capacity 200 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Supply and Install in replacement on load Changeover switch 415 Volt in open execution 4 pole of capacity 400 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Supply and Install in replacement on load Changeover switch 415 Volt in open execution 4 pole of capacity 630 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including 02 Nos of Flat Iron clamps of size 50x6mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including 02 Nos of Flat Iron clamps of size 50x6mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 100 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including 02 Nos of Flat Iron clamps of size 50x6mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Dismantling of damaged/ rusted steel tabular poles any size and removal from site complete all as specified & directed by Engineer-in-Charge.
Supply, installation and erection in replacement steel tubular swaged welded poles 9.0m long complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing confirming to IS-1161 part-II, type 410 SP -31 including drilling of holes of required size and nos for fixing of cross arms/clamps, poles shall be painted internally throughout using anti corrosive black bituminous paint and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete,painting three alternating layer of each black and yellow paints at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- Any wire, any type cable, any type box, CCTV camera, any type street light fitting, poster,picture or any items fixed with old pole shall be taken down carefully and safely and refixed to the new steel pole in same position in quoted rates.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board,LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified & directed by Engineer-in-Charge. Note- The unit rate includes main earthing lead GI earth strip of size 32x6 mm with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr complete all as specified & directed by Engineer-in-Charge. Note : - The rate qouted shall be inclusive of necessary Earth work encavations returning filling etc required for earth pit and main earthing lead, GI Earth strip of size 32 x 6mm with 40mm light grade GI pipe for earth lead protection from earth electrode to test point upto 7.5M
S&F GI strip 32 x 6 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building/ connect to LT panel or main DB and joining the same with existing earth test point all complete all as specified & directed by Engineer-in-Charge.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified & directed by Engineer-in-Charge.
M&L End termination indoor / outdoor joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 70 to 120 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L End termination indoor / outdoor joints heat shrink type for XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 150 to 185 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L for End termination indoor / outdoor joints heat shrink type for XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 240 to 300 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Cable jointing kit straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 70 sqmm to 120 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Cable jointing kit straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 150 sqmm to 185 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Painting of LT steel tubular pole 7.5 mtr long (above ground) after cleaning the complete body surface of pole by rubing with emery paper to remove old paint,dust etc and applying two coat of aluminium paint by brush to complete pole and painting three alternating layer of each black and yellow synthetic enamel paint at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge.
M&L for painting of LT RCC poles pole 7.5 mtr long (above ground) after cleaning the complete body surface of pole by rubing with emery paper to remove old paint,dust etc and applying two coat of white cement based paint by brush to complete pole and painting three alternating layer of each black and yellow synthetic enamel paint at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge.
M&L Scrapping and removing of existing paint,dust,rust by emery paper or other means and preparation of smooth surface for painting and painting with two coat of high quality synthetic enamel paint with approved colour on any size ,any type and any capacity feeder pillar box, LT panel including writing of incoming and outgoing location of all cables on LT panels and feeder pillar boxs with high quality synthetic enamel paint red colour complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Digital type ammeter of range 0-600 Amp Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Digital type Voltmeter of range 0-500 Volts Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement LED indicator lamp 240 V set of three (R,Y,B) of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Current transformer (CT) 300/5A , accuracy class 1.0 , burden 10 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Current transformer (CT) 250/5A , accuracy class 1.0 , burden 10 VA, resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Current transformer 100/5A , accuracy class 1.0 , burden 5 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Digital type Frequency meter , class 0.2 of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in Replacement of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size, fixed as in repairs,complete all as specified & directed by Engineer-in-Charge.
M&L Loose filling with aggregates of gauge 40 mm filling in Panel & surrounding area as per ground availability of area, cleaning the area, removing vegitation,debris around panel upto 2 mtr radius making level, and filling the aggregate upto 100 mm height complete all as specified & directed by Engineer-in-Charge.
Supply, installation,commisioning and testing Weather proof busbar chamber 600x450x300MM made out of 2 MM thick CRCA steel sheet & 40x5 MM angle iron frame suitable for mounting 1 mtr above ground level with locking arrangements incl. Provn of 4 Nos aluminium busbar of 600 Amps rating mounted on insulated frames 2 Nos incl. connecting up incoming & outgoing cables complete with glands,lugs incl.painted with two coats of powder coated paint over a coat of red oxide primer, including necessary PCC 1:3:6 type C1 in foundation for mounting complete all as specified & directed by Engineer-in-Charge.
Supply, installation,commisioning and testing out door type LT Panel made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame of size 50mm x 50mm x 6mm with canopy top,two side ventilators,front openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proof suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 630 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories:-
Incoming (a) MCCB 4 Pole,400 Amps, 415 volt of breaking capacity not less than 35 KA -1 No . (b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No. (c ) Indicator lamp LED type set of three(R,Y,B) - 1 No (d) Digital type Voltmeter composite type with ,0-500 Volts -1 No. Outgoing (a) MCCB 4 Pole,125 Amps, 415 volt of breaking capacity not less than 35 KA -1No . (b) MCCB 4 Pole,63 Amps, 415 volt of breaking capacity not less than 25 KA-4 Nos .
Dismantling and taking out old burnt cable lugs and S&F aluminium cable lugs ISI marked including cutting of burnt cable terminals ,prepare and crimping the cable lugs with LT cable for the following size complete all as specified & directed by Engineer-in-Charge:-
M/s BHOOMI ELECTRICALS
S SELVALAKSHMI ENGINEER AND CONTRACTOR
M/s STAR ELECTRICALS
Shiva Shakthi Electrical Enterprises
ARUNOTHAYA TRADERS
devan enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .