Signalling work in connection with provision of COP in ULNR-KJT section and improvement of facade, circulating etc area at karjat section of mumbai division.
CR-BB-SNT-NORTH-2026-47
CR-BB-SNT-NORTH-2026-47
Open
12 Months
Mumbai, Maharashtra
₹0
₹1.3 L
6 May 2026
6 May 2026
22 May 2026
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 1.6 A (System, Rapid or Malnad Make).
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 0.6 A (System, Rapid or Malnad Make).
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 6 A/10A (D- Type Bharat Linder, L&T or HEVELLS Make).
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 1.6 A (System, Rapid or Malnad Make).
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 0.6 A (System, Rapid or Malnad Make).
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 6 A/10A (D-Type Bharat Linder, L&T or HEVELLS Make).
Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding 07 the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.
Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest.
Supply of PVC flexible copper cable single core, multistrand 1x2.5 Sq.mm (50 09 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.
Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 10 conductor each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.
Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway.
Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 12 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender.
Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys.
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment.
Supply of Stop Board / IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice.
Supply of different warning Board as per Goods warning Board (SK-784) RDSO Drg No. SA 2380 (Adv), SA 2370/M-, Block section limit Board RDSO Drg No. SA 2373 - Paint and retroreflective arrangement as per Railways drawing.
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995.
Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET OF 10 MM THICKNESS AS PER ISO: 10192-1982, Dielectric strenth -25KV/mm with glass content 25 to 34% in standard size of 1.10x1.10 Mtr as per spec. No.IS:10192-1982
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3.
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make.
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4.
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest.
Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type 25 terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only.
Supply of DIN Channel for the terminals 1 Mtrs each
Supply of End plates for modular terminal block
Supply of End Clamp for modular terminal block
Supply of Marker Card as per customer spec (10x10)
Fuse terminals block with LED indication up to 2.5 sqmm screw type one in one out (suitable for (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10 A ) as per RDSO SPN/189/2004 Ver.03 or latest . (without fuse)
End plate for through terminal block with LED indication.
Fuse links of (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10A)
Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make.
Supply of Adhesive Tapes rolls, PVC (18mm x 25 Mtr) Steel Grip/SCOTCH/ANCHOR.
Supply of cable route marker as per RST/C/203A of FRP Above/
Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.
Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and 03 Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice.
Supply of Signal No.Plates as per Drg No RST-11393/ SK-842
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC,30 A t o spec.IRS.S.86/2000 (Amndt-1) with latest amendment for Axle counter application (Amd.4)
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment.
Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys.
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 08 Alt.4, & SA-23756 Alt.3.
Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration.
Supply of Apparatus case with godown locks with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration.
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments.
Supply of cable route marker as per RST/C/203A of FRP Above/
Fixing of stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 02 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. a) Single Case
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 03 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. b)Half Case Per
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. Per
Termination of cable cores on ARA terminal/fuse blocks in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. i) Single Case as per Drg No SK-803
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. ii)Half Case as per Drg No SK-804
Erection of Apparatus cases. This includes filling of location foundations and plastering .i)Single Case
Erection of Apparatus cases. This includes filling of location foundations and plastering. ii)Half Case
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. i) Single Case
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. ii)Half Case
Installation of earth electrode assembly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, 12 apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer 13 of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm 14 thickness afer clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
Cutting of all types of Roads/platforms (except concrete type) for trenching and 15 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Digging of trench 1.0 M deep from rail flange/road level (for LC) and, 0.3 Mtr to 0.6 17 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806
Laying of DWC/RCC pipes alongwith collars / RCC Half round pipes in trenches at places of track and road crossings, platform cutting etc.
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.
Fixing of modular termianal/fuse blocks alongwith all accessories with provision of 20 fixing holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing on DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination of modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the 21 apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 22 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(i)Apparatus Cases Full size.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 23 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(ii)Apparatus Cases Half size.
Providing Road Breaker/concrete breaker/boulder or rock breaker with compressor & 24 Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section) including contractors fuel, driver and all other charges completed as directed by Engineer in charge
Lettering / Numbering of Signals, Point Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc.(each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.
Releasing of cables from old location boxes and taking it into new location boxes. This 26 includes excavating the earth to release the cables. From old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station/ central cabin. Unit(Per Location=1 set) Above/
Excavation and Casting of main signal foundation as per Drg No SK 801 with 01 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.
Erection of CLS post with surface base and signal unit on top or on OFF set Bracket, 02 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.
Termination of tail cable on Main signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.
Installation on ON/OFF aspect LED's in signal including termination of tail cable on signal, wiring fixing of LED units and testing. The work shall be done as per instruction of Railway engineer at site.
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 05 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. a) Single Case
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 06 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. b)Half Case
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instructions of Engineer in charge. Per
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. Per
Termination of cable cores on ARA terminal/fuse blocks in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. i) Single Case as per Drg No SK-803
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. ii)Half Case as per Drg No SK-804
Erection of Apparatus cases. This includes filling of location foundations and plastering .i)Single Case
Erection of Apparatus cases. This includes filling of location foundations and plastering. ii)Half Case
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. i) Single Case
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. ii)Half Case
Installation of earth electrode assembly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, 16 apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Installation, wiring, testing and commissioning of Microprocessor based universal earth leakage detector unit 12 channel AC/DC.
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer 18 of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
Cutting of all types of Roads/platforms (except concrete type) for trenching and 19 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807
Digging of trench 1.0 M deep from rail flange/road level (for LC) and, 0.3 Mtr to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.
"Where ever depth of 0.5 m cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench."
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 23 instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence o f Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 24 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(i)Apparatus Cases Full size.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 25 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(ii)Apparatus Cases Half size.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- 26 charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(iii)Main signal post with signal Units, Surface base and complete fittings as per Centre Railways standard practice.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 27 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(iv)Shunt signal post with signal unit, surface base as per central Railway's Standard Practice.
Lettering / Numbering of Signals, Point Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc.(each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes.(a)Full Case.
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes.(b)Half Case. Above/
Item Breakup - C1-SUPPLY & EXECUTION
Supply of Microcontroller based programmable Numbers static switchingmodule of naturally air cooled onlywith an at a glance LCD displaysuitable for break-less switchingbetween two DC supplies of UP to40A for 20-110VDC.(Inspection Agency- RITES)
Installation and commissioning ofmicrocontroller Numbers basedprogrammable static switchingmodule of naturally air-cooled onlywith an a glance LCD displaysuitable for break-less switchingbetween two DC supplies of UP to40A for 20-110VDC. (cable forrailways(Inspection Agency-Consignee)
PDCU for Multi section digital axle counter Numbers (MSDAC) as per RDSO/SPN/176/2005 Make Eldyne electro System Pvt. Ltd. (Inspection Agency-RDSO)
Supply of HSS straight shank jobberDrill ground Numbers 50.00 flute to IS 5101/DIN 338/BS 328 ISO of size 7.1 mm ofAddison, JK make ofsimilar(Inspection Agency-Consignee)
Drill twist H.S.S. for MORSE taper shank type N Numbers 20.00 dia of drill bit 16 mm to IS 5103 / 1969 with amendement no. 1 to 3.(Inspection Agency- Consignee)
Supply of straight shank twist drill jobber size 13 Numbers 30.00 mm of make Addison,JK as per IS 5099/1983 for material & hardness(Inspection Agency- Consignee)
SK 30H double rail contact with 8 meter cable for Numbers Eldyne make Multi/Single section Digital axle counter as per RDSO specification no.RDSO/SPN/176/2013 ver.3 or latest and manufacturer specification. Make Eldyne electro systems Pvt.Ltd. (One no.packet contains the 02 no.TX and 02 nos RX Coils for rail connection sufficient for 1 DP including all accessories) (Inspection Agency-RDSO)
Supply of Track side Electronics Unit (EAK) Card Numbers for MSDAC as per RDSO Specification No.RDSO/SPN/176/2013 Ver.3 or latest or manufacturers specification.(Inspection Agency- RDSO)
WELD LESS MODULAR TYPE SS MEDUIM SIZE Numbers LOCATION BOX(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
WELD LESS MODULAR TYPE SS POST BOX Numbers LOCATION BOX(Inspection Agency-Consignee)
Supply of AC & DC low current clampmeter with Numbers range 1 mA to 60 A or higher make FLUKE, RISHABH, GTC CM 100.(Inspection Agency- Consignee)
Casting of cement concrete toprotect S&T cum equipments andlaid cables, above pipes, Signalstore etc by concrete mixtureof cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate as perinstruction of site in charge ofrailways. Concrete is to becasted with the help of suitablesize shuttering form as per siterequirement. Concrete is to becured for sufficient time as perstandard practices onrailways(Inspection Agency-Consignee) Total 1985120.65
Item Breakup - C2-SUPPLY & EXECUTION
Supply of Cable fault locator as per specification. Numbers Make : Tempo, Stanlay or Greenlee. Module SIDEKICK PLUS 1155-5001(Inspection Agency- RITES)
Supply of Megger 100V, 50 ohms hand driven Numbers type in Metal body with handle of Nippen, Motwani, Fluke or Rishabh make.(Inspection Agency- Consignee)
Supply of DWC/HDPE pipe with one snap fit Metre coupler 'O' ring confirming to IS 14930 (Part 2: 2001) Non metallic, normal duty, pliable with protection against chemical attack and fire resistant, anti rodent, in 6 meter length of size 50 mm inner dia.(Inspection Agency- Consignee)
Supply of "4 Aspect" Signal Unit in Alluminium Numbers body without lenses and transformers or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post (Inspection Agency- Consignee)
Digital current clamp meter to measure current Numbers leaks parasitic draws down to 1 mA and electric load from 1 mA to 100 Amp AC/DC, and voltages from 0 to 600 V AC/DC, small jaw size to measure current in signaling circuits, 4 digit display. make FLUKE/ GTC/KIOCO or superior with better specification mentioned with all accessories like test lead, batteries and carrying case, sample may got approved from consignee before supply. (Inspection Agency- Consignee)
"Rechargeable LED head light with hand sensor, Numbers 50.00 500 Lumen power integrated with 3W COD flood light with 3.7V, 1000MAH lithium battery, Impact proof ABS, Black woven head band. Make: Groz , Model : LED/225 or Equivalent in Make : Fenix or Ledlenser or Olight or Petzl only Make/Brand:GROZ Firm's accepted offer- Accepted Make: Head Lamp Dual Mode and Hand Sensor, Model No.- LED-225. Warranty: For Light warranty will be 12 Months from the date of delivery, and for Battery warranty will be 06 Months from the date of delivery. ,make/model- Groz, (Warranty Period : Upto 30 months from the date of delivery.)(Inspection Agency- Consignee)"
Supply of 120mm HDPE pipe for laying in Metre Horizontal Borring (Inspection agency- consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Raincoat (waterproof) with attached Cap/hood Numbers 50.00 and separate waterproof trouser with fullsleeves. Sizes as per requirement given by Railway Engineer Incharge(Inspection Agency- Consignee)
Reflective Specification as per Annexure A.(Inspection Agency- Consignee)
Safety shoes of various sizes as per IS Numbers 50.00 15298(Part2):2011/ISO 20345:2004 with following features. 1) Steel toe cap confirming to IS 5852 with minimum impact energy of 200 Joules.2) Oil, chemical & heat resistance, antistatic, anti sleep &electric hazard smooth upper mash fabric for cooling effect. 3) Double density directly injected. Some of reputed brand are Bata, Liberty, Action, Relaxo(Inspection Agency- Consignee)
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes etc by concrete mixture of cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate asper instruction of site incharge of railways. Concreteis to be casted with the helpof suitable size shutteringform as per site requirement.Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency- Consignee) Total 1376419.37
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
CORRECTIONSLIP1to11GCC2022_compressed.pdf GCC CORRECTION SLIP 1 TO 11
ATTACHMENT
FINALNEWTENDERDOC2026471.pdf
ATTACHMENT
CORRECTIONSLIP1to11GCC2022_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid