Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹21.7 L+₹2.0 L (9.93%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹22.8 L+₹3.1 L (15.9%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M S Enterprises L1 | M/S SURYA ELECTRICALS L3 | Vivek Electricals L2 |
|---|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa iw.kZ tek ;kstuk ds vUrxZr fuos'k fe=@>ViV iksVZy ij vkosnukuqlkj la;kstu fuxZr djus gsrq ykbZu fuekZ.k vkfn dk;ZA | ||||||
| 1.01Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms. | ||||||
| 1.02 | S.T Pole 13 Mtr. Long | 5 | Nos. | 1,200 ₹6,000 Lowest | 1,280 ₹6,400 | 1,300 ₹6,500 |
| 1.03 | PCC Pole 11 Mtr. Long | 5 | Nos. | 1,500 ₹7,500 Lowest | 1,650 ₹8,250 | 1,700 ₹8,500 |
| 1.04 | S.T Pole 11 Mtr. Long | 15 | Nos. | 1,200 ₹18,000 Lowest | 1,240 ₹18,600 | 1,250 ₹18,750 |
| 1.05 | PCC Pole 8.5 mtr Long. | 65 | Nos. | 1,200 ₹78,000 Lowest | 1,210 ₹78,650 | 1,250 ₹81,250 |
| 1.06 | Carriage of All line Material from store center BSR to je store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc. | 130 | Qtl | 450 ₹58,500 Lowest | 548 ₹71,240 | 550 ₹71,500 |
| 2.00Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | ||||||
| 2.01 | S.T Pole 13 Mtr. Long | 3 | Nos. | 2,000 ₹6,000 Lowest | 2,008 ₹6,024 | 2,010 ₹6,030 |
| 2.02 | PCC Pole 11 Mtr. Long | 3 | Nos. | 2,850 ₹8,550 Lowest | 2,890 ₹8,670 | 2,900 ₹8,700 |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
22 Aug 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
A 37 hydel colony Kavinagar Ghaziabad
The work of issuing conjunctions according to the application on the full deposit scheme (investment friend/rustic portal) in the field of electricity distribution division Modinagar.
2025_PVVNL_1064900_1
T-15/2025-26/EDC/GZB
Open Tender
Electrical Works
Item Rate
365 days
Superintending Engineer EDC GZB
Please refer tender document
2 documents required · 2 mandatory
₹3,540
Superintending Engineer
₹20,000
9 Sept 2025
11 Aug 2025
22 Aug 2025
11 Aug 2025
22 Aug 2025
11 Aug 2025
Amount
fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa iw.kZ tek ;kstuk ds vUrxZr fuos'k fe=@>ViV iksVZy ij vkosnukuqlkj la;kstu fuxZr djus gsrq ykbZu fuekZ.k vkfn dk;ZA
Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
S.T Pole 13 Mtr. Long
PCC Pole 11 Mtr. Long
S.T Pole 11 Mtr. Long
PCC Pole 8.5 mtr Long.
Carriage of All line Material from store center BSR to je store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
S.T Pole 13 Mtr. Long
PCC Pole 11 Mtr. Long
S.T Pole 11 Mtr. Long
PCC Pole 8.5 mtr Long.
Erection of Double pole/Scation Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
S.T Pole 13 Mtr. Long
PCC Pole 11 Mtr. Long
S.T Pole 11 Mtr. Long
PCC Pole 8.5 mtr Long.
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms, including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
S.T Pole 13 Mtr. Long
PCC Pole 11 Mtr. Long
S.T Pole 11 Mtr. Long
PCC Pole 8.5 mtr Long.
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
S.T Pole 13 Mtr. Long
PCC Pole 11 Mtr. Long
S.T Pole 11 Mtr. Long
PCC Pole 8.5 mtr Long.
Carriage of All line Material from J.E store Sub station to Pit Site ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
Cutting/drilling/Welding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
Carriage of 11 Kv CT/PT metering polemounted unit Varius ratio
Carriage and installation of 11 Kv Pilferresistant metering cubicle with out cable termination kit
Mounting of 11 KV CT/PT Unit Varius ratio
Making/Filling of 11 Kv Cable Jointing kit Varius size XLPE cable
Loading/Unloading & Carriage of T/F from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
10/16 KVA T/F
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
Fixing of 11 Kv Stay rod with Stay wire in proper way with Nozelling
Grouting of 11 Kv Stay rods
Guarding of 11 kv line.
Laying, sagging. Stringing and binding and jumpering of 11 Kv XLPE cable 3*70 Square MM & Outher size newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
11 Kv XLPE cable 3*70 Square MM
11 Kv XLPE cable 3*120 Square MM
11 Kv XLPE cable 3*185 Square MM
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal, rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
ACSR weisal conductor
ACSR Rabbit/Dog conductor
ABC Cable 3*50 Square Mм
ABC Cable 3*95 Square MM
ABC Cable 3*120 Square MM
Fixing of Earthing rod
Fixing of pin insulator
Fixing of Distribution Box.
Fixing disc insulator
Fixing of X arm/Toff Channel
Fixing of Top/Drop channel
Fixing of Sub station Angle.
Fixing of Fuse Set.
Transfomer Plinth.
Fencing Of TF
Paroviding & Fixing Chemical Earthing of Distribution Transformer and proper Completion of work as per RESSPO Manual.
Road Broken/Trench Digging with the help Road Cutter/Digging Machine/Tractor etc.
Mounting & Installation of T/F From D/P
10/16 KVA T/F
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
The folloing material is required to be supplied by the contractor.
Holding clamp.
11 Kv Cable Jointing kit 3*70 Square mm XLPE cable
Providing Of Dixtribution Box
Double Pole clamp.
F Clamp
LT Clamp
PG Clamp
Jhook
Earth clamp
TF Clamps. 04 Nos, (02 Set)
Stay clamp
Dead & clamps
Stay insulator for 11 Kv
Suspension clamps
LT Insulator
Bolt & nut off size.
Vivek Electricals (BID ID -5467788)
M/S SURYA ELECTRICALS (BID ID -5461399)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .