Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹5.1 L
Closing Date
30 Jul 2026, 3:00 pm
Electrification work in connection with "Provision of pathway at various Stations over Agra Division".
T-11-N-2026-27
T-11-N-2026-27
Open
8 Months
Agra, Uttar Pradesh
₹0
₹5.1 L
7 Jul 2026
7 Jul 2026
16 Jul 2026
A-Electrification work in connection with " Provision of pathway at
250W. LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, 1 Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (8.17.6)
100 WattLED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, 2 powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (8.16.3)
Supply, Erection, testing and Commissioning of LT control panel outdoor, cubical floor mounted Hut type dust and vermin proof multi layer construction, weather proof proper ventilation arrangement, outdoor type LT distribution board for operation on 3 phase 4-wire, 415V AC supply system recondition with 14 SWG MS sheet base MS angle 50x50x6 mm MS Channel 75x40x6 mm. It 3 shall be coated with 2 coats approved colour. The LT panel shall be of front operated with copper conductor cable, cable glands, earthing studs, feeder, name plate and danger board on front. The LT panel shall be erected on the floor. The panel shall comprises of 400 Amps copper bus bar with protection equipment, 01 Number incoming side 250A MCCB 50KA, 4X100 A MCCB 36KA, 2X63A MCCB 30KA and 05 Nos. 32A MCCB 3OKA. All MCCB should be 4-pole type voltmeter, Ammeter indicating lamps shall be fitted all incoming and outgoing side complete with locking arrangement and all other required accessories as per site""
Excavation of cable trench:-This item shall be operated in conformity with IS:1255(latest version) i.e. code of practice for installation and maintenance of HT/LT cables. The price shall cover cost of excavation of cable trench in all type of soil for laying LT cables and back filling the same with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HT cables the trench shall be 600mm wide x 1000mmdeep. In 4 trench the cable shall be covered with river sand at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross position through out the cable route in the ground. The bottom of the trench should level free from stones and sharp edge of rocks etc. At the termination a loop of 5 meter (approx) cable shall be kept as allowance and loops rings be formed as per the site condition, in the ground, The cost shall include the cost of all materials i.e. sand, bricks, cable route markers (groutedin the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m.interval and each turn of the cable.
Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (asper IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)
Horizontal boring of cable duct at 1.4 to 2.1 mtr. depth from the bottom of 6 sleeper/ground lable and laying of120 mm dia HDPE DWC pipes for cable crossing under track/ road .The work shall be done as per extant practice and instruction of site engineer. It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Supply, Erection, Testing and commissioning of Single earth electrode of 50mm dia 3000mm long GI Pipe class B conforming to IS: 1239 latest complete with earth box including connection from earth electrode to MDB/SDB/poles/With 8 SWGGI Wire
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED 8 fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (50 watt) (8.14.12)
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia 9 pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (72 watt) (8.14.13)
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia 10 pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (45 watt) (8.14.11)
Supply, Erection, Testing and Commissioning of GI pipe 'B' class of minimum 50 mm. dia, suitable for cable protection or underground rail/road crossing with fixing clamp at least 03 Nos. for one pipe of MS flat of 50 x 6 mm. size clamp duly Aluminum painted.
Supply, Erection, Testing and commissioning of hot dip galvanized octagonal pole 5 12 Mtr. long confirming to IS 2629/BSEN ISO 1461 or equivalent including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc. the pole shall be complete with holes, Anchor bolts, bottom plate etc. As per Tech. Specification/site requirement, IS/IE rules of Double Arm type with 1.5 feet to 2 feet long type
Supply, erection, testing & commissioning of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers.
Dismantling & Removal of L.T. Existing Rail/Tubular pole and refilling the same with excavated earth and finishing the surface in its original condition after removal the existing Rail/Tubular pole handed over to concerned SSE/G store.
Supply, erection, testing & commissioning of 16 mtrs. long High Mast system with its accessories duly hot dip galvanized and suitable for wind velocity as per IS 875 Part - 03 or latest. It shall also include 03 points suspension head of steel frame with 06 mm dia steel wire rope, double drum with galvanized Lantern carriage arrangement, suitable for 06 Luminaries symmetrically and its control gear boxes. The Mast shall have an optional arrangement for external power for its operation i.e. lowering and raising system. Supply of foundation bolt manufactured from special steel 15 along with nut, Washers, Anchor Plate & template. Supply and installation of Control Panel Board consisting with 40 Amp four pole MCB, forward and reverse contactor for lowering and lifting, Astronomical timer & suitable control circuit (with required ble/wire) for the operation of the High Mast. Design and casting of suitable shallow foundation with M-20 Concrete for the High Mast considering safe soil bearing capacity at site as 10 T/SQ MTR at 02 Mtrs depth with Cement Concrete, Sand, ratio 1:3:6 complete with 06 Nos 200 Watt LED Beam light & fitting outdoor type Complete with 02 nos. pipe earthlings arrangement required as per site. (Note:- Section-1 Mast Bottom thickness - Min 4 mm to 5 mm & Section-2 (3mm to 4 mm))
Supply, erection, testing and commissioning of 30W. Led Luminaire Light LED Luminaire IP-65 s per IS 10322, IS 16107, IS 16108, IS 16103, IS 10322 (Q3)
Supply, Erection, Testing and commissioning of outdoor/indoor end termination kit 17 with cast resin compound including aluminium lugs and other jointing materials (such as back alight seat etc.) for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. (4 X 16 sq. mm) (11.2.29)
Supplying and fixing 5 A to 32 A Single pole rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (CPWD item no. 2.10.1)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
T-11-N-2026-27TENDERDOCUMENTS.pdf
ATTACHMENT
GCCApril202227-04-2022.pdf
ATTACHMENT
GCCACScorrectionslip1_compressed.pdf
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf gcccorrectionslip11
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
Letterofcredit.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid