Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹8.7 L
Closing Date
7 Jul 2026, 12:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
17 conditions · 6 needing a document upload
10.2. Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Balance Sheet Declaration- Balance sheet for the 4th previous year (i.e. FY 2022-23 or as applicable) as per para 10.2 of GCC-2022 shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annex-VI B or a self declared certificate as attached duly signed by chartered accountant and the tenderer that the balance sheet of last financial year (i.e. FY 2025-26 or as applicable) has not been audited/yet to be prepared. If, balance sheet of last financial year (i.e. FY 2025-26 or as applicable) is not yet audited/ prepared ,then NIL position to be uploaded.
10.1 Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of similar nature of work:- Any signalling work involving design, installation, testing, commissioning of EI or alterations of EI.
Bidder has to upload requisite information as per Annexure V(A) along with the offer.
43 conditions · 5 needing a document upload
Stamp Duty fee for Bank Guarantee (for bid security) should be paid which should be 0.5% of the Bid security or Rs.10,000/-, whichever is less or as per latest/revised state policy of UP state.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) /registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate. (Note:In case of non-submission of above documents, offer may be summarily rejected)
The tenderer will give full information ( in annexure-A) as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender,if a tenderer is - i) be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, OR ii) being partnership firm / joint venture (JV) / registered society / registered trust etc have as one of its partners/members a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated company have any such retired Engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender
If a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of his partner(s)/shareholder(s) or member(s) of the family of partner(s)/shareholder(s) having share of more than 1% in the tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons. ( in annexure- A)
An undertaking shall be submitted by sole proprietorship firm, HUF, JV, LLP, Company registered under companies Act 2013 that he/they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract.(Note: Each member must sign separately in case of JV/Partnership firm/LLP.).(Note: IN case of non submission of above documents, offer may be summarily rejected).
In case of partnership firm an undertaking shall be submitted by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (Note: In case of non-submission of above documents, offer may be summarily rejected)
Please submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Whether the cost of tender form is submitted in hard copy if uploaded as a scanned copy in website.
Whether the cost of Bid Security is submitted in hard copy if uploaded as a scanned copy in website.
16.(1) Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfilment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
16.(4) Performance Guarantee:- The procedure for obtaining Performance Guarantee is outlined below: (a)The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty-one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty-one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty-one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work.
(b)The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value: and Additional Performance Guarantee as per clause 16(4)(h) in any of the following forms (i)A deposit of Cash; (ii)Irrevocable Bank Guarantee; (iii) Insurance Surety Bond as per Annexure-XVII Note:- In case of extension of Date of Completion, selected bidder needs to submit extended Insurance Surety Bond/Fresh Insurance Surety Bond/fresh Performance Security, in any form as given above, before expiry of existing Insurance Surety Bond. (iv)Government Securities including State Loan Bonds at 5% below the market value; (v)Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (vi)Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vii)Deposit in the Post Office Saving Bank; (viii)Deposit in the National Savings Certificates; (IX)Twelve years National Defence Certificates; (x)Ten years Defence Deposits; (xi )National Defence Bonds and (xii) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of Sr. DFM (free from any encumbrance) may be accepted. (c)The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d)The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e)The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f)Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g)The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i)Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii)Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii)The Contract being determined or rescinded under clause 62 of these conditions. (h) If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below Bid quoted in % of advertised cost -Additional Performance Guarantee(%) Below 0-5% (Inclusive)- Nil Below 5%- 5%
Balance sheet for the 4th previous year (i.e. FY 2022-23 or as applicable for the instance tender) as per para 10.2 of GCC-2022 shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annex-VI B or a self declared certificate duly signed by chartered accountant and the tenderer that the balance sheet of last financial year (i.e. FY 2025-26 or as applicable for the instance tender) has not been audited/yet to be prepared. Annexure has been attached for such certificate format
All Rules of NIT & Post LOA shall be governed by GCC & tenderer agree to adhere to it without any dispute
General Conditions of Contract-2022 has been added in tender document. Please go through this General Condition of Contract-2022 along with advanced correction slips before bidding. In case of any discrepancy, contradiction with regard to GCC (except special condition of contract) in that case GCC- 2022 will be applicable
S&T works in c/w (A) Prayagraj Division-Provision of stabling lines at Subedarganj station. (B) Construction of a new island platform at Subedarganj (SFG) by dismantling at line No. 2 & 3 along with retaining of existing PF No. 6.
PRYJ-Sig-009-2026-27
PRYJ-Sig-009-2026-27
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹8.7 L
7 Jul 2026
4 Jun 2026
23 Jun 2026
184 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Below/Par | ||
| — | — | — | 2,53,48,088.92 | ||
| — | 27.00 | — | — | ||
| Fixing, wiring, testing and commissioning of Electrical Point Machine on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes (i) Complete material for installation like ground- connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) nstallation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded frame for cable entry to machine. (vi) Supply and filling of industrial grade/good quality lubricant/grease/oil for smooth operation of point machine. Note: The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately Inspection by-Consignee | — | — | — | 3,90,188.61 | |
| — | 34.00 | — | — | ||
| Supply of stretcher bar insulation complete set consisting of the following: - Plate-T-10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos.Inspection by-Consignee | — | — | — | 12,970.66 | |
| — | 34.00 | — | — | ||
| Supply of gauge tie plate insulation complete set each set consisting plate T-10372 = 1No., Bush T- 10368=3 Nos. and washer - T-10371 = 6 Nos.Inspection by-Consignee | — | — | — | 12,985.96 | |
| — | 34.00 | — | — | ||
| Supply of IRS Type point machine 'D'/'P' bracket insulation complete set consisting of the following: - Plate LH - S-3266-1 No., RH - S-3265-1 No., Plate S-8804- 1 No., Bush - S- 3199 - 4 Nos, Bush S-8813- 2 Nos.Inspection by-Consignee | — | — | — | 16,320.34 | |
| — | 17.00 | — | — | ||
| Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20-21, 9151-52,9000-01,03-04,9065-6,9101, as applicable.Inspection by- Consignee | — | — | — | 2,50,397.59 | |
| — | 37.00 | — | — | ||
| Supply and fixing of GI bend pipe 50 mm dia., 'B'class, for cable entry into Point machine with all accessories. Note: This item to be operated independently for those points where Point machines are functional but GI bend pipe is not provided. For all other new installation of Point machines, item 06002 of the SOR includes the provision of GI bend pipe.Inspection by-Consignee | — | — | — | 1,17,983.75 | |
| — | 17.00 | — | — | ||
| Refixing of electrical point machine, ground connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment, if necessary, cable termination, wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on NCR and the instruction of Railway Engineer at site. Inspection by- Consignee (Per Unit=Per T/Out) | — | — | — | 96,469.39 | |
| — | 5.00 | — | — | ||
| Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. Inspection by-Consignee | — | — | — | 2,99,072.2 | |
| — | 5.00 | — | — | ||
| Laying of HDPE duct as per the approved cable route plan in the excavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings No. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8 (a) respectively, issued vide Chapter-XIII of the Telecomm Manual.Inspection by-Consignee | — | — | — | 31,507.9 | |
| — | 10.00 | — | — | ||
| Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor. Inspection by-Consignee | — | — | — | 62,562.2 | |
| — | 5.00 | — | — | ||
| Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already provided in the trench. Th e cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.Inspection by-Consignee | — | — | — | 85,527.05 | |
| — | 10.00 | — | — | ||
| Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own machine and tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.Inspection by-Consignee | — | — | — | 1,20,090.1 | |
| — | 20.00 | — | — | ||
| Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer Inspection by-RDSO | — | — | — | 67,223 | |
| — | 20.00 | — | — | ||
| Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77- 2012 (Rev.3.0) with (Amdt.- 1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer Inspection by-Consignee | — | — | — | 34,267.6 | |
| — | 2.00 | — | — | ||
| Supply of Optical Time Domain Reflectometer (OTDR), operating at 1550 nm and 1310 nm for working on single mode optical fiber as per TEC spec. TEC/GR/TX/OTD - 001/05/SEP- 19 or latest, of reputed make like Yokogawa/JDSU/Viavi or similar. Consignee shall approve the supply only after successful demonstration at site.Inspection by-RITES | — | — | — | 8,49,749.56 | |
| — | 64.00 | — | — | ||
| Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS- 943 and RDSO Specn.No.IRS:S@45"44@ S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "BCEJK".Inspection by-RDSO | — | — | — | 3,43,048.96 | |
| — | 10.00 | — | — | ||
| Q-Series Twin Neutral Line Relay (QNN1 Type), 6F/2B, 24V DC complete with plug board (base plate), connectors and retaining clips etc. and conforming to BRS-960 and RDSO Specn.No.IRS:S@45"44@ S-23 or latest, as applicable. The interlocking code for this unit shall be "ACDEK".Inspection by-RDSO | — | — | — | 53,436.4 | |
| — | 20.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors,retaining clips etc. and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH".Inspection by-RDSO | — | — | — | 88,784.8 | |
| — | 10.00 | — | — | ||
| Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1 or latest and RDSO Spec.No.IRS:S@45"44@ S-23 or latest, as applicable.The interlocking code for this unit shall be "ABDHK".Inspection by-RDSO | — | — | — | 69,173.8 | |
| — | 20.00 | — | — | ||
| Q-Series Neutral Line Relay, non-AC immunised, (QN1 Type), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 ,S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABCDF".Inspection by-RDSO | — | — | — | 72,788.2 | |
| — | 1030.00 | — | — | ||
| Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest.Inspection by-RDSO | — | — | — | 2,50,856.5 | |
| — | 1030.00 | — | — | ||
| Supply of Non deteriorating type, round head type, low voltage cartridge fuse as per Spec No IRS: S - 78/2006 with latest amendments, 2A/4A/6A/8A/10A rating capacity.Inspection by-RDSO | — | — | — | 1,26,834.2 | |
| — | 5500.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done.Inspection by-Consignee | — | — | — | 3,55,795 | |
| — | 2500.00 | — | — | ||
| "Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection by-RITES" | — | — | — | 15,17,175 | |
| — | 400.00 | — | — | ||
| "Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. Inspection by- Consignee" | — | — | — | 4,11,616 | |
| — | 2500.00 | — | — | ||
| "Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.Inspection by-Consignee" | — | — | — | 16,05,275 | |
| — | 120000.00 | — | — | ||
| "Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection by-Consignee" | — | — | — | 8,20,800 | |
| — | 4000.00 | — | — | ||
| Supply of Disconnect Terminal block for four conductors with screwing cage/clamp type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks. Inspection by-RDSO | — | — | — | 7,70,880 | |
| — | 9000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. Th e item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. Th e outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engineer incharge of the work.Inspection by-Consignee | — | — | — | 1,32,840 | |
| — | 6000.00 | — | — | ||
| Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest.Inspection by-RDSO | — | — | — | 7,02,060 | |
| — | 6000.00 | — | — | ||
| "Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately). Inspection by-Consignee" | — | — | — | 1,05,780 | |
| — | 14.00 | — | — | ||
| Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg.No.NR/S&T/Const/2.2/97 using standard size of foundation/galvanized anchor bolts complete, required for erection of shunt signal post. Anchor bolts complete should comply with the RDSO Drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged / provided by contractor Inspection by-Consignee | — | — | — | 51,361.24 | |
| — | 14.00 | — | — | ||
| Erection of Position Light Shunt signal with Base, Post, Signal unit,complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.Inspection by-Consignee | — | — | — | 13,314.7 | |
| — | 20.00 | — | — | ||
| "Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.Inspection by-RITES" | — | — | — | 5,49,996.2 | |
| — | 43.00 | — | — | ||
| Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full (Apparatus Case as per RDSO drg. No. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with Apparatus case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case. Foundation shall be done as per Drawing no.AGC/Full loc/2023/01. Inspection by-Consignee | — | — | — | 5,27,705.46 | |
| — | 20.00 | — | — | ||
| "Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full) Inspection by-Consignee" | — | — | — | 89,528.8 | |
| — | 43.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)Inspection by-Consignee | — | — | — | 28,949.75 | |
| — | 20.00 | — | — | ||
| Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.Inspection by-Consignee | — | — | — | 1,672.2 | |
| — | 1.00 | — | — | ||
| Supply of Ferrule/Tube Printer & label printer along with 5 nos. of Tap cartridge as per specification as under, Compatible Tube Diameter 2.5-6.5 mm, supported tube type - PVC, multi-line printing, Maximum Tape Width Up to 36mm, Auto Cutter.Inspection by-Consignee | — | — | — | 52,399.45 | |
| — | 500.00 | — | — | ||
| Supply of pressure Sensitive Adhesive Plasticized PVC Tapes having 20 mm Width, minimum 25 Meter length. The colour of the tape shall be decided by Railway in charge. Make: Protex/Nippon/Anchor or better.Inspection by-Consignee | — | — | — | 20,620 | |
| — | 70.00 | — | — | ||
| Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 Mtr. deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge.Inspection by-Consignee | — | — | — | 2,34,747.8 | |
| — | 10.00 | — | — | ||
| Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot.Inspection by-Consignee | — | — | — | 9,174.4 | |
| — | 21.00 | — | — | ||
| Installation of DC track circuits (Point zone) including supply of materials as per directive of site Engineer. Note : (i) This includes drilling 9/32" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fi sh plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper ires/cables,fi xing of track circuit equipment i.e. track charger, resistance, fuses, batteries,chokes, relays, anti-titling arrangement and painting, lettering and numbering of DC track circuit equipments etc., (ii) [a] Un-machined fi sh plates shall be supplied by the Railway's, but machining of fi sh plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fi sh plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B- type choke, Resistance, Un-charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. These are to be transported to site of work at contractor's cost. Tenderer/Contractor shall supply any other materials that are required for the work.Inspection by-Consignee | — | — | — | 2,68,053.24 | |
| — | 2.00 | — | — | ||
| Embedded software modification in (1) FEP in test room and (2) CMU in test room, to accept and transfer the relevant station data to a client PC. Inspection by-Consignee | — | — | — | 3,49,707.24 | |
| — | 43.00 | — | — | ||
| Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS:S@45"44@ S-23 , S-60 or latest, as applicable.The interlocking code for this unit shall be "FGHKX".Inspection by-RDSO | — | — | — | 1,63,539.75 | |
| — | 60.00 | — | — | ||
| "Supply of Track Lead Junction Box (TLJB), 4 way, made from FRP, as per Drg. no. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest. The technical specifications are as follows: (a) TLJB complete with cover to be in lack/red/grey with all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Along with each TLJB, nickel chrome plated brass links (two nos. of adequate strength for vertical linking of the terminals to be supplied . (c) HDPE pipe along with two nuts for fixing on the TLJB hole. (d) The FRP stump for mounting the TLJB.Inspection by-Consignee" | — | — | — | 3,27,902.4 | |
| — | 23.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Spec. no. IRS: S-89/2013 Ver.1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery. Inspection by-RDSO | — | — | — | 1,35,712.88 | |
| — | 113.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No. SA-20161-66/M or latest.Inspection by-RDSO | — | — | — | 2,57,615.14 | |
| — | 46.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 3) or latest.Inspection by-RDSO | — | — | — | 2,71,819.98 | |
| — | 30.00 | — | — | ||
| "Multi section Digital Axle Counter (MSDAC) supply,design, installation, testing and commissioning of multi section digital axle counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version 3 with Latest amendments or latest. Suitable for commissioning of yard/Auto Section/dual detection (DCTC/AFTC with MSDAC). MSDAC should have facility to reset track sections. Design of axle counter circuit indoor installation testing and commissioning of multi section digital axle counter (per unit), supply of essential 10% spares covering all types of cards, wheel sensors for MSDAC. Supply of Diagnostic system for Remote diagnostics Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, gloves and multimeter fluke 115 (1 Nos. per 14 DP). NOTE: 1. If any housing is required to keep outdoor equipment, it has to be supplied with the equipment with no extra cost. 2. Maintenance free earthing (supply and installation) for track device/mushroom housing etc. to be done by the contractor if required by system design. No extra cost/ payment will be made by this Railway: 3. Automatic resetting facilities through hardware/software for auto resetting to be 8 provided by contractor by his own materials for this no extra cost/payment will be made by Railways. 4. MSDAC system networking to be done with central control room. Required hardware PC/ network F equipment to be provided by the contractor, no extra cost/payment will be made for this by Railway. El Channel/media will be provided by Railway for this purpose from nearest Railway station. 5. All other Hardware like TPR, Extra card to make dual DP, Modem, ethernet switches etc. if required for commissioning and final track section pick up will be supplied by contractor, no extra payment will be made by this Railway. 6 Separate evaluator for UP and Down line to be provided at Station/RH as decided by Railway site engineer. For the communication between evaluator to evaluator (RH to Station) Quad/ OFC Link (dark fiber) will be provided by Railway. Any other Networking equipment if required will be supplied by contractor at no extra cost. 7. Manual resetting through reset box and LV box at station to be provided as per requirement." Inspection by-RDSO | — | — | — | 95,26,998.6 | |
| — | 6.00 | — | — | ||
| Ground connections for universal point machine143 mm with 'D' type clamp for 52kg/ 60kg/ 90R rail as per Org. No. RDSO/S3267-74Inspection by-Consignee | — | — | — | 52,020 | |
| — | 2.00 | — | — | ||
| Supply of complete set of ground connections for high thrust 220 mm stroke point machine along with insulation as per Org. No RDSO/33454 Alt. B dt 25-01-2023 or latest along with insulation.Inspection by-Consignee | — | — | — | 1,16,820 | |
| — | 50.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23, S- 60 or latest, as applicable. The interlocking code for this unit shall be "ABDFH".(Inspection by RDSO).Inspection by- RDSO | — | — | — | 1,84,808 | |
| — | 5.00 | — | — | ||
| Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit. Inspection by-Consignee | — | — | — | 1,26,368.4 | |
| — | 100.00 | — | — | ||
| Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer. .Inspection by-Consignee | — | — | — | 45,376 | |
| — | 5.00 | — | — | ||
| "Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA-23080/Adv.along with fixing U bolts, nut and clamps. Inspection by-Consignee" | — | — | — | 6,032.95 | |
| — | 5.00 | — | — | ||
| Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter no. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. Inspection by- Consignee | — | — | — | 67,531.4 | |
| — | 5.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring of complete signal including route and auxiliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates /boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. Inspection by-Consignee | — | — | — | 29,393.7 | |
| — | 2.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No.RDSO/SPN /151/1997 or latest.Inspection by-Consignee | — | — | — | 62,616.16 | |
| — | 1.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.Inspection by-Consignee | — | — | — | 35,737.37 | |
| — | 1.00 | — | — | ||
| Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway Signalling suitable for RE area FOUR Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO spec. No. RDSO/SPN/151/1997 or latest. Inspection by-Consignee | — | — | — | 42,230.83 | |
| — | 4.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete, Non-Metallic, made of FRP as per Drg. No. SA- 23840 (Adv.) suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).Inspection by- Consignee | — | — | — | 59,583.16 | |
| — | 23.00 | — | — | ||
| Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.Inspection by-Consignee | — | — | — | 1,34,023.99 | |
| — | 5000.00 | — | — | ||
| Supply of 16/0.2 mm (0.5 sq mm) PVC insulated multi strand, single core, tinned copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length.Colour of the wire will be specified by the Engineer incharge.Inspection by-Consignee | — | — | — | 53,750 | |
| — | 1500.00 | — | — | ||
| Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire , 85 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge.Inspection by-Consignee | — | — | — | 72,000 | |
| — | 1500.00 | — | — | ||
| Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge.Inspection by-Consignee | — | — | — | 1,98,690 | |
| — | 2.00 | — | — | ||
| Supply of Junction route indicator unit 1 way, made of FRP, (Without Lenses & Holder) as per Drg. No. SA 23401 -06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amdt. -1 or latest and RDSO/SPN/194/2006 Rev.2 or latest, (Supply of LED Unit is not covered in this item) .Inspection by- Consignee | — | — | — | 88,912 | |
| — | 6.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consists of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable. Inspection by-RDSO | — | — | — | 1,08,255.12 | |
| — | 6.00 | — | — | ||
| Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00-meter-long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made irement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Spec. No. RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are: (i) SDO/RDSO/E&B/001 for typical installation of Earth. (ii)SDO/RDSO/E&B/002 for typical bonding and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements Inspection by- Consignee | — | — | — | 43,159.02 | |
| — | 2.00 | — | — | ||
| Supply of Digital Ac and DC Leakage Clamp on meter, make/model ST-CL360, DCM 39A/Motwane or similar.Inspection by-Consignee | — | — | — | 1,13,705.74 | |
| — | 2.00 | — | — | ||
| Supply of Insulation resistance tester, 100 Mega ohms, 500V DC, hand generator type. Make Meco/Motwane/Waco or similar.Inspection by-Consignee | — | — | — | 35,811.84 | |
| — | 2.00 | — | — | ||
| Supply of Insulation resistance tester, 10 Mega ohms, 100V DC, hand generator type. Make Meco/Motwane/Waco or similar.Inspection by-Consignee | — | — | — | 31,808.34 | |
| — | 2.00 | — | — | ||
| Supply of Digital Clamp Earth tester/meter., with memory storage facility, make Motwane/Meco/Fluke or better.Inspection by-Consignee | — | — | — | 2,31,687.12 | |
| — | 10.00 | — | — | ||
| Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fittings like wheel, pulleys, wires, stakes etc. All the released material will be transported to the SSE/Consignee depot.Inspection by-Consignee | — | — | — | 14,437.2 | |
| — | 30.00 | — | — | ||
| Q-Series Neutral Line Relay (QSPA1 Type), AC immunised, 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-933A and RDSO Specn.No.IRS:S@45"44@ S-23, S 60 or latest, as applicable. The interlocking code for this unit shall be "ABDEJ".Inspection by-RDSO | — | — | — | 1,81,692 | |
| — | 3.00 | — | — | ||
| Miscellaneous arrangements for NI period comprising of a) Temporary Goomty /Tent of dimension at least 12'x12' at both side of the station yard and at central panel building, furnished with one table, six chairs, emergency light and mosquito repellent. b) Sufficient temporary lighting arrangement throughout the yard from Sunset to sunrise one day prior, during and post NI work. This includes provision of two DG set of minimum 7.5 KVA capacity and halogen flood lights. The DG sets and Diesel etc. has to be arranged by the contractor at his own cost. c) Provision of PA System at both the end of the yard. d) Resting arrangement for at least 16 staff at night. e) Vehicle for transportation for to and from movement of S&T staff during NI period. f) Manning of adjacent station to be done by contractor. g) Provision of printing/Xerox copies of drawings, wiring diagram, CTR/ Location box terminal chart, point wiring, MSDAC/track circuit wiring, NI program, Signal wiring, track bonding plan, etc. in a plastic folder. No. of copies depends upon the number of team formed for NI and as per instruction of officer incharge of NI. h) This also includes Free home & Free Starter wiring for NI as per the instruction of site engineer. (Up to 200 routes) Inspection by- Consignee (Per Unit=Per Station Per day) | — | — | — | 2,91,225 | |
| — | 1.00 | — | — | ||
| — | 30.00 | — | — | ||
| — | — | — | 7,617.6 | ||
| — | 2.00 | — | — | ||
| — | — | — | 15,798.76 | ||
| — | 2.00 | — | — | ||
| Supply of Junction route indicator unit 2 way/ 3 way, made of FRP,(Without Lenses & Holder) as per Drg. No.SA 23401-06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amdt. -1 or latest and RDSO/SPN/194/2006 Rev.2 or latest. (Supply of LED Unit is not covered in this item).Inspection by-Consignee | — | — | — | 90,917.22 | |
| — | — | — | Below/Par | ||
| — | — | — | 1,82,04,140.82 | ||
| — | 2.00 | — | — | ||
| Supply of paints, primers,varnish and other painting material, complete painting and varnishing ,lettering, numbering of all signalling gears, including signal posts and fittings, apparatus cases, point machines, junction boxes, signal machine, rail post, other gears etc. complete at a station/mid section gates/huts, letter writing on terminal Nos. apparatus cases, point machine, Signal Nos. and other details as per S.E.M., instructions of Engineer at site and as per Technical specifications. (station/yard).Inspection by-Consignee | — | — | — | 1,37,575.48 | |
| — | 2.00 | — | — | ||
| "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor""Inspection by-Consignee" | — | — | — | 43,187.24 | |
| — | 10.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete,Metallic, Independent type, along with base and post, hood, Cover etc as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item)Inspection by-Consignee | — | — | — | 1,00,008.9 | |
| — | 10.00 | — | — | ||
| Supply of Offset brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No SA-23080/Adv. along with fixing U bolts, nuts and clamps.Inspection by-Consignee | — | — | — | 16,057.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexVIB.pdf
ATTACHMENT
TypicalDiagramforLocationBoxFoundationdrawing1.pdf
ATTACHMENT
TenderDoc22_5.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
AnnexureA.pdf
ATTACHMENT
BankGuaranteeforBidsecurityformat.pdf
ATTACHMENT
LASTFYDECLARATION.pdf
ATTACHMENT
2025_06_24SeekingclarificationonapplicabilityofGCCCorrectionSlipNo_102.pdf
ATTACHMENT
JPO-05-2023UndertakingtheworkoflayingundergroundSignallingTelecomcablesandEngineeringdiggingwork.pdf
ATTACHMENT
GCC-CorrectionSlip1-2-3-4-5-6-7-8-9-10-11_compressed1.pdf
ATTACHMENT
SFGTSIP20260421_144917_compressed.pdf
ATTACHMENT
SFGTSIP20260421_144917_compressed_1.pdf
ATTACHMENT
signalfoundationdrg.pdf
ATTACHMENT
Annexure-CSignalMaint.ToolKit.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .