| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹19.7 LQualified Make: CbS
Model: TOCP-050-S 110 111 1 ST FLOOR RISHABH IPEX MALL ROAD NO 58A I P EXTENSION NEW DELHI DELHI 110092 INDIA | EAST DELHI | DELHI | 110092 | Make: CbS
Model: TOCP-050-S | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 Jun 2018, 12:00 pmClosed
centrifugal oil cleaning machine Average Turn Over of Last 3 Years 500000 Lakh (s) Experience with Gov. Required 5 Year (s) Centrifugal Oil Cleaning Machine ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values MODE OF WORKING TYPE/USAGE Mode of Working Offline Offline Type Portable Portable Suitable for Cleaning Transformer Oil Transformer Oil Type of Cleaning Removal of Both Solid Contamination and Liquid Contamination Removal of Solid Contamination Only
Removal of Liquid Contamination Only
Removal of Both Solid Contamination and Liquid Contamination Application/Usage Transformer Oil - PERFORMANCE Nominal Flow Rate (LPH) 5000.0 5000
5000.0 Dirt Holding Capacity 10000.0 500
1000
2000
4000
8 000
10000
12000 Minimum Size of Dirt( including metallic
Non Metallic
Suspended soild particle ) Separated (microns) 5.0 - AUXILIARY Centrifuge Pump 80.0 1/4 INFORMATION Flow Rate (LPM) Centrifuge Motor Capacity (HP) 0.5 0.5
0.75
1
2
3
4
5 Suction Pump Flow Rate (LPM) 110.0 - Suction Pump Motor Capacity (HP) 3.0 - Make of Motor (Suction Pump) Crompton - Discharge Pump Flow Rate (LPM) 110.0 - Discharge Pump Motor Capacity (HP) 3.0 - Make of Motor ( Discharge Pump) Crompton/Centrifugal pump - Vacuum Pump for First stage true - Vacuum Pump For Second Stage false - Vacuum Pump Motor Capacity ( For First Stage ) 2 - Vacuum Pump Motor Capacity ( For Second Stage ) NA - Vacuume Booster for First stage false - Vacuume Booster for Second stage false - Vacuum Booster Motor Capacity ( For First Stage ) NA - Vacuum Booster Motor Capacity ( For Second Stage ) NA - Vaccum Blower false - Vacuume Blower Motor Capacity(HP) 0.0 - Moisture Separator Yes - If yes Then Moisture Separating Capacity 1.0 - Heating System true - Heating Capacity 24.0 - Degassing Chamber true - Capacity of Degassing 480.0 - 2/4 Chamber Ionic Reaction Cartridge false - Oil Reclarmation Catridge false - Water adsorption Catridge false - Magnetic strainer true - Online Moisture PPM Sensor false - Tramp Oil Skimmer false - Filter catridge (for Solid Contamination removal only) consumable - The System shall be complete with control Panel with necessary gauage(s)
flowmeter(s) and other electrical switches
MCBs
Relays etc Yes - List of Standards Accessories of Panel Box with quantity to each one Indicator Light 3 phase - 3 Nos. Volt meter - 1 Nos. Amp. meter - 1 Nos. Hour Counter - 1 Nos. Push Button - 4 Nos. MCB TP 32 Amp - 1 Nos. MCB SP 6 Amp - 3 Nos. Contractor - 12 Amp 3 pole 2 Nos. O/L Relay - 2.5-4 Amp - 2 Nos. Protection relay - VSP- D-1 Cable Wire - 4C X 1.5mm2 - Operating Pressure
Max 5.0 - Operating Temperature 60.0 - Length of the centrifugal Oil Cleaning Machine 1265.0 - Width of the centrifugal Oil Cleaning Machine 600.0 - Height of the centrifugal Oil Cleaning Machine 1230.0 - weight of the centrifugal Oil Cleaning Machine 1500.0 - WARRANTY Warranty 1.0 1
5 3/4 CERTIFICATION Availability of Test Report from Central Govt/NABL/ILAC acredited lab to prove confirmity to specification true - Test Report No and Date GN 13642
29-Aug-2013 - Name and Address of the Lab Narang Metallurgical & Spectro Services
New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devinder Singh Bedi 180012
ELECTRICAL CENTRAL STORE COMPLEX
RAIL HEAD JAMMU 3 30 EMD Required No ePBG Required No
181808
GEM/2018/B/25905
centrifugal oil cleaning machine
30 days
Jammu And Kashmir; Jammu
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| centrifugal oil cleaning machine Average Turn Over of Last 3 Years 500000 Lakh (s) Experience with Gov. Required 5 Year (s) Centrifugal Oil Cleaning Machine ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values MODE OF WORKING TYPE/USAGE Mode of Working Offline Offline Type Portable Portable Suitable for Cleaning Transformer Oil Transformer Oil Type of Cleaning Removal of Both Solid Contamination and Liquid Contamination Removal of Solid Contamination Only | - | - | - |
| Removal of Liquid Contamination Only | - | - | - |
| Removal of Both Solid Contamination and Liquid Contamination Application/Usage Transformer Oil - PERFORMANCE Nominal Flow Rate (LPH) 5000.0 5000 | - | - | - |
| 5000.0 Dirt Holding Capacity 10000.0 500 | - | - | - |
| 1000 | - | - | - |
| 2000 | - | - | - |
| 4000 | - | - | - |
| 8 000 | - | - | - |
| 10000 | - | - | - |
| 12000 Minimum Size of Dirt( including metallic | - | - | - |
| Non Metallic | - | - | - |
| Suspended soild particle ) Separated (microns) 5.0 - AUXILIARY Centrifuge Pump 80.0 1/4 INFORMATION Flow Rate (LPM) Centrifuge Motor Capacity (HP) 0.5 0.5 | - | - | - |
| 0.75 | - | - | - |
| 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Suction Pump Flow Rate (LPM) 110.0 - Suction Pump Motor Capacity (HP) 3.0 - Make of Motor (Suction Pump) Crompton - Discharge Pump Flow Rate (LPM) 110.0 - Discharge Pump Motor Capacity (HP) 3.0 - Make of Motor ( Discharge Pump) Crompton/Centrifugal pump - Vacuum Pump for First stage true - Vacuum Pump For Second Stage false - Vacuum Pump Motor Capacity ( For First Stage ) 2 - Vacuum Pump Motor Capacity ( For Second Stage ) NA - Vacuume Booster for First stage false - Vacuume Booster for Second stage false - Vacuum Booster Motor Capacity ( For First Stage ) NA - Vacuum Booster Motor Capacity ( For Second Stage ) NA - Vaccum Blower false - Vacuume Blower Motor Capacity(HP) 0.0 - Moisture Separator Yes - If yes Then Moisture Separating Capacity 1.0 - Heating System true - Heating Capacity 24.0 - Degassing Chamber true - Capacity of Degassing 480.0 - 2/4 Chamber Ionic Reaction Cartridge false - Oil Reclarmation Catridge false - Water adsorption Catridge false - Magnetic strainer true - Online Moisture PPM Sensor false - Tramp Oil Skimmer false - Filter catridge (for Solid Contamination removal only) consumable - The System shall be complete with control Panel with necessary gauage(s) | - | - | - |
| flowmeter(s) and other electrical switches | - | - | - |
| MCBs | - | - | - |
| Relays etc Yes - List of Standards Accessories of Panel Box with quantity to each one Indicator Light 3 phase - 3 Nos. Volt meter - 1 Nos. Amp. meter - 1 Nos. Hour Counter - 1 Nos. Push Button - 4 Nos. MCB TP 32 Amp - 1 Nos. MCB SP 6 Amp - 3 Nos. Contractor - 12 Amp 3 pole 2 Nos. O/L Relay - 2.5-4 Amp - 2 Nos. Protection relay - VSP- D-1 Cable Wire - 4C X 1.5mm2 - Operating Pressure | - | - | - |
| Max 5.0 - Operating Temperature 60.0 - Length of the centrifugal Oil Cleaning Machine 1265.0 - Width of the centrifugal Oil Cleaning Machine 600.0 - Height of the centrifugal Oil Cleaning Machine 1230.0 - weight of the centrifugal Oil Cleaning Machine 1500.0 - WARRANTY Warranty 1.0 1 | - | - | - |
| 5 3/4 CERTIFICATION Availability of Test Report from Central Govt/NABL/ILAC acredited lab to prove confirmity to specification true - Test Report No and Date GN 13642 | - | - | - |
| 29-Aug-2013 - Name and Address of the Lab Narang Metallurgical & Spectro Services | - | - | - |
| New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devinder Singh Bedi 180012 | - | - | - |
| ELECTRICAL CENTRAL STORE COMPLEX | - | - | - |
| RAIL HEAD JAMMU 3 30 EMD Required No ePBG Required No | - | - | - |
Exempted
18 Jun 2018
7 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_181808.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .