Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹23.9 L+₹57,498.44 (2.47%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹24.8 L+₹1.5 L (6.55%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹25.2 L+₹1.8 L (7.88%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
29 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col NK Chaudhary
HQ 137 Wks Engrs PIN 914137 Co 99 APO
REPAIRS MAINT OF TRANSFORMER HT DISTRIBUTION SYSTEM AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
2021_MES_491595_3
8631/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Masimpur
As per NIT
2 documents required · 2 mandatory
₹500
Yes
GE Silchar
₹44,000
Yes
10 May 2022
7 Mar 2022
31 Mar 2022
7 Mar 2022
29 Mar 2022
15 Mar 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for foundation of poles, cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and exceeding 1.50 metre but not exceeding 3.00 metre depth for foundation of poles, cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50.00 metre and deposited/ spreaded where directed at a level n. exc 1.50 metre above the starting point complete all as specified and as directed .
Materials and labour for sand filling, 8 cm (compacted) below the cable and 15 cm after laying of cable to be punned down to a depth of 10 cm above the top of the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Taking down existing electric pole of any type / size including demolition of existing concrete for pole foundation complete all as specified and directed.
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of red & white alternate strips of 30cm each externally from ground level upto 1.9 m with synthetic enamel paint, numbering of poles complete all as specified and as directed. (Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
Dismantling of corroded / rusted / defective cross arms of MS channel or angle section etc complete all as specified and directed.
Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.
Dismantling of old unserviceable insulator, any type / size complete all as specified and directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
Supply and fixing Disc type insulator, porcelain, vitreous, 145 mm high and 255 mm dia ball and socket type, white, brown or green 'Two in series' disc assembly including nuts, bolts as requirred for 11000 volts grade confirming to relevant IS complete all as specified and as directed.
Dismantling of old unserviceable damaged stay assembly embedded in concrete including demolition of PCC complete all as specified and directed.
Supply and fixing stay assembly with using 16 mm diameter of stay rod complete with accessories as shown in electrical plate No. 1 all as specified and directed. (Note: loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately)
Supply and fixing galvanised stay strand, 7/3.15 mm complete all as specified and directed.
Dismantling old unserviceable air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism for repair / replacement of broken / worn out components and insulators etc complete all as specified and directed.
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulators and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, with 9 insulators of rating upto 200 Amps complete all as specified and as directed.
Taking down of HT 11 KV cable after disconnecting from both ends, any size complete all as specified and directed.
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands and including suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type-1, with peak, size 300mm x 180mm x 40mm laid flat and dry in trenches over the cable complete all as specified and directed.
Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Repair to HT 11 KV 4 pole structure, 11 metre height steel / RCC poles including replacement of all perished ACSR consuctor (weasel) of horizontal bus bar and down conductor for 4 Nos / 2 Nos GOD system on structure, jumpering and binding with alluminium conductor to the post insulators / pin insulators and providing PVC sleeve insulation grade-II suitable for 11 KV to the down conductor with colour code R, Y & B, replacing all rusted nuts and bolts complete all as specified and directed.
Repair to HT 11 KV 2 pole / 3 pole structure, 11 metre height steel / RCC poles including replacement of all perished ACSR consuctor (weasel) of horizontal bus bar and down conductor for 4 Nos / 2 Nos GOD system on structure, jumpering and binding with alluminium conductor to the post insulators / pin insulators and providing PVC sleeve insulation grade-II suitable for 11 KV to the down conductor with colour code R, Y & B, replacing all rusted nuts and bolts complete all as specified and directed.
Supply. Install, testing and commissioning lightning arrestor non linear resistor type complete with all fittings, line discharge class-3, nominal discharge current10 KA (Peak), 12 KV rated system voltage peak value high current impulse of 4/10 micro sec, wave shape 100 KA (Peak) assy suitable for 11 KV, long duration class-11 with insulation level28/75 KV and insulated on hot dip galvanised steel structure including all clamp. nuts, bolts and washers and connecting to earth complete on pole structure all as per IS-3070 Part-III (1993) and IEC 1994 including dismantling of old unserviceable one complete all as specified and dirceted.
Supply and laying 80 mm bore GI tubing, light grade with all fittings for passing of UG cables including taking up / down old unserviceable tubing complete all as specified and directed.
Disconnecting the HT/LT connection of existing outdoor type transformer of any capacity mounted on plinth and transport to factory for carrying out repairs, opening the transformer, lifting core and reassembling after rewinding and overhauling including draining and refilling of transformer after dehydration of transformer oil complete and refixing the same after repair / testing at its original position or position as indicated and connecting to HT/LT cable properly including testing of oil before and after complete all as specified and directed. (Note: (i) Spare parts and rewinding shall be measured and paid in relevant items. (ii) The cost of crane charges for loading / unloading of transformer at site and factory premises including transportation, labour charges for loading / unloading from site to factory and back are deemed to be included in quoted rate.)
Shifting of transformer carefully from the existing 2/4 pole structure / plinth / storeyard to another location under GE Silchar including transportation and connecting / disconnecting from HT / LT side and reconnecting the same and commissioning and testing complete all as specified and directed, (Note: Required tools and plants, labour and transportation charges for shifting shall deemed to be included in the quoted rate.)
Supply only HT bushing suitable for outdoor type transformer upto 200 KVA capacity conforming to IS 334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply only HT bushing suitable for outdoor type transformer from 250 KVA upto 500 KVA capacity conforming to IS 334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply only HT brass studs with brass nuts, bolts and washers suitable for upto 200 KVA transformer complete all as specified and directed.
Supply only HT brass studs with brass nuts, bolts and washers suitable for from 250 KVA upto 500 KVA transformer complete all as specified and directed.
Supply only LT bushing suitable for outdoor type transformer upto 200 KVA capacity conforming to IS 334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply only LT bushing suitable for outdoor type transformer from 250 KVA upto 500 KVA capacity conforming to IS 334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply only LT brass studs with brass nuts, bolts and washers suitable for upto 200 KVA transformer complete all as specified and directed.
Supply only LT brass studs with brass nuts, bolts and washers suitable for from 250 KVA upto 500 KVA transformer complete all as specified and directed.
Material and labour for rewinding the unserviceable burnt out copper winding wire for HT & LT sides of Transformers 150 KVA and 315 KVA capacity with copper conductor super enamelled / DPC impregnated paper insulated as per existing gauge and turns with necessary insulating materials , varnishing, heating backing complete all as specified and directed.
Supply and fixing as in repair old unserviceable drain plugs of suitable size for existing transformer complete all as specified and directed.
Supply only new transformer oil of dielectric strength not less than 50 KV and conforming to IS-335 of 1993 for filling / topping up of transformer up to desired level complete all as specified and directed.
Dehydration and filtration of existing transformer / Servo stabilizer oil at different location with filtration machine and heating system to get the minimum di-electric strength of oil 50 KV at 2.5mm gap minimum without disturbing the power supply system and refilling / topping up / replacement of unserviceable transformer oil conforming IS 335-1993 complete all as specified and directed. (Note: (a) Transformer oil required extra for refilling / topping up shall be measured and paid separately under the relevant item of this schedule. (b) Cost for testing of oil including T&P shall deemed to be included in the quoted rate.)
Supply and fixing silica gel breather with all accessories filled with silica gel for transformer of capacity of 250 KVA including removing of old breather complete all as specified and directed.
Supply and fixing silica gel breather with all accessories filled with silica gel for transformer of capacity of 315 KVA including removing of old breather complete all as specified and directed.
Taking out unserviceable cork sheet gasket of any description of transformer and providing new cork sheet gasket of 5 mm thick best quality complete all as specified and directed.
Material and labour for spray painting of transformer with two coats of Ducco paint (grey) after cleaning through and preparation of surface of transformer to receive painting for transformer of capacity 315 KVA including writing of MES No. / SM No. complete all as specified and directed.
Material and labour for 100 mm thick hardcore of broken stone / boulder, gauge n.exc. 63mm, spreading , levelling and compacting to a true surface complete all as specified and directed.
Material and labour for Repair / Overhauling / Servicing and testing of 33 KV and 11 KV VCB at site including removing incomming and outgoing cable connection, moving and fixed contacts, cleaning the parts with CTC, servicing the contactors, checking the VCB panel healthiness of fault tripping system by using secondary injection method and checking breaker closing coils, improving the insulation resistance and reassembling the same after replacement of unserviceable spare parts and making the VCB fully serviceable condition to the entire satisfaction of GE complete all as specified and directed. (Note: (i) Spare parts shall be measured and paid in relevant items. (ii) Repair work shall be carried out by authorised service engineer of the OEM and the cost for bringing service engineer at site shall be borne by the contractor.)
Supply only spring charging motor suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only trip coil suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only close coil suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only master trip relay, 110 volts suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only master trip relay, 110 volts suitable for 33000 Volts indoor type VCB complete all as specified and directed.
Supply only HRC fuse grip as per existing and with HRC fuses from 2 to 16 Amp complete all as specified and directed.
Supply only epoxy resin cast CT having ratio100.5+5A, 15VA, CL-5P10 suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only current transformer having ratio 100/5 and 50/5 suitable for 11000 Volts outdoor type VCB, insulation level 70/70 KV complete all as specified and directed.
Supply only digital voltmeter suitable for 11000 Volts VCB, complete all as specified and directed.
Supply only digital Ammeter with CT suitable for 11000 Volts VCB, complete all as specified and directed.
Supply only electrical insulation gloves, Type 4, test potential 25 KV, working voltage 17 KV as per IS 4770 complete all as specified and and directed.
Supply only HT tape complete all as specified and directed.
Supply only fix vaccum interrupter suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only motor charging bearing suitable for 11000 Volts indoor type VCB complete all as specified and directed.
Supply only spring charging motor suitable for 33000 Volts indoor type VCB complete all as specified and directed.
Supply only fix vaccum interrupter suitable for 33000 Volts indoor type VCB complete all as specified and directed.
Material and labour for trimming of various sizes of tree branches which are touching / close to LT over head line at various place and clear the LT over head line upto 3.00 metre from conductor close to tree along pole to pole complete all as specified and directed. (Note: (a) All the safety equipments, cutting materials, ladder etc requirred for the work to be provided by the contractor. (b) Pole to pole distance to be measured in span. (c) The cutting shall be done two times during the contract period as requirred basis. (d) Before and after photograph and video recording of the work will be done and kept on record.)
Cleaning of the shrubs, vegetation grass, bushes, plants and saplings grown below HT line around the stay and all substation in the area and cleaning the rubbish materials and dumping at places as directed complete all as specified and directed. (Note: (a) Before and after photograph and video recording of the work will be done and kept on record.)
Material and labour for pouring distilled water for battery bank of 33/11 KVMRS Sub station complete all as specified and directed.
Supply and fixing in replacement of 33 KV outdoor type CT, Ration-100-50A/5-5A, VA-15, class-0.5, 5P 10 solid earth rated frequency 50 Hz system failure-25 KA for 3 sec complete all as specified and directed with the following specification:- (a) Type three phase accuracy class 0.2S CT. (b) Rated primary current upto 200-400 A and secondary 5/1 Amp in CT. (c) Rated primary voltage 33 KV, secondary 110 PT (d) Rated burden-5 VA (0.8 Lagging PF per Phase in CT) (e) Rated burden-30 VA (0.8 Lagging PF per Phase in PT) (f) Current density 1.5 Amp/Sqmm (g) Instrument security factor<5 (h) Maximum allowable temperature rise 50 dgree centigrade (CT & PT). (j) Winding of material-Copper (CT & PT) (k) Dynamic current-40KA.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth lead upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Materials and labour for rendering 15mm thick plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 100 mm thick PCC (1:2:4) type B2 (using 40 mm graded stone aggregate) as in flooring of sub station area complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate as in cover slab for manholes, ducts etc, set in cement mortar 1:6 including necessary formwork complete all as specified and directed.
ICON TECHNOLOGY
APPLE CONSTRUCTION
M/S Satish Chand Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .