Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 CrAccepted-AOC | ₹2.7 Cr Quoted ₹2.3 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹2.6 Cr+₹36.9 L (16.2%)Rejected-AOC GODREJ GENESIS BUILDING UNIT NO 609 PLOT NO XI 6TH FLOOR BLOCK EP GP SECTOR V SALT LAKE KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.6 Cr+₹36.9 L (16.2%) | 2 | Rejected-AOC L2 |
| 3 | 3₹2.7 Cr+₹38.1 L (16.7%)Rejected-AOC | ₹2.7 Cr+₹38.1 L (16.7%) | 3 | Rejected-AOC L3 |
| 4 | 4₹2.7 Cr+₹43.0 L (18.9%)Rejected-AOC SINGHI HOUSE RM ROAD JORHAT 785001 | JORHAT | JORHAT | ASSAM | 785001 | ₹2.7 Cr+₹43.0 L (18.9%) | 4 | Rejected-AOC L4 |
| 5 | 5₹2.7 Cr+₹43.2 L (19.0%)Rejected-AOC | ₹2.7 Cr+₹43.2 L (19.0%) | 5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹7 L
Closing Date
7 Jun 2021, 12:00 pmClosed
CGM (PP and D)
1st floor, AEGCL, BIJULEE BHAWAN, GHY-1
Turnkey Construction of two nos. of 132kV Line bays including Supply of Bay Equipment and Line bay materials and associated works, etc. at Gohpur GSS, AEGCL
2021_AEGCL_21641_1
AEGCL/MD /TECH-845/LILO GOHPUR/2019/BID
Open Tender
Electrical Works
Turn-key
240 days
Gohpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
₹7 L
Yes
GUWAHATI
16 Jul 2021
8 May 2021
8 Jun 2021
8 May 2021
7 Jun 2021
18 May 2021
14 May 2021
Amount
145kV, 3150A, SCR 40kA for 1 sec, SF6 Circuit Breaker, outdoor type, 3-ph gang operated complete with terminal connector, operating mechanism & support structure
(i)145kV Gang operated SF6 Breakers as specified above (DC -110V)
Indoor floor mounted, simplex type Control & Relay Panel with mimic & annunciation panel for 132kV feeder as per specification comprising of the C&R panels shall be complete with Numeric Relays as per the Technical Specifications & shall be compatible for SCADA/SAS as open protocol.
(i) For 132 kV Feeder Panel (Simplex Panels) as specified above
145kV outdoor type . live tank single phase Current Transformers as per the details below
(i) CTR 800-400/1-1-1-1 A ( Feeder CT)
145kV , 1-ph, Capacitor Voltage Transformer ( CVT) for 132kV line
(i) 132 kV, 132/Ö3 / 110/Ö3 /110/Ö3
145kV, 1250A, 40kA for 1 sec, 3-ph gang operated Horizntal Centre Break ( HCB) , outdoor type , motor operated Isolators including solid core post insulators , mounting structure complete with nuts, bolts , washers and foundation bolts
132 kV With single Earth Switch
132 kV Without Earth Switch
120kV, 10kA metal oxide type, heavy duty, station class-3 Lightning Arrester complete with Surge Counter & flexible copper connecting lead
132 kV Lightning Arrester
Post Insulator
132 kV Post insulator
Supply of Mounting structures of all equipment including nuts, bolts & washers ( as per enclosed drg for bidding purpose)
Current Transformers
132 kV, 800-400/1-1-1 Line CT ( 174.511kg per CT, 6x174.511kg = 1047.066kg )
Foundation Bolts (20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Capacitance Voltage Transformer
132 kV CVT( 184.393kG per CVT, 184.393x6=1106.358kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate , 1.816kg per bolt )
Lightning Arrester
132 kV Lightning Arrester ( 218.879kg per LA, 218.879x6=1313.274kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Post Insulator
132 kV Post insulator ( 219.59kg per PI, 219.59x16=3513.44kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Bay Steel Structures except equipment mounting structures
9.1 COLUMNS: (For Column types refer drawings)
Column Type ‘C3’ ( 2013.77+78.88=2092.65 kg per column, 2092.65x4=8055.08kg)
Foundation bolt ( 40mm dia, 1500mm length with 300mm threaded , nuts, lock nuts , washers and anchor plate, 17.55kg per fdn bolt, Total 17.55x16x4=1123.20 kg)
BEAMS: (For Beam types refer drawings)
Beam Type ‘B2 796.61+35.191=831.801kg per beam , 831.801x5=4159.005kg’
Supply of Power and Control Cables
Power Cables
4C, 4 sqmm
4C, 6 sqmm
Control Cables
Supply of ACSR Conductor
ACSR ‘PANTHER’
Disc Insulator String complete with all hardware, fittings, clamps etc.
10 Disc Tension Insulator String for twin Panther
9 Disc Suspension Insulator String
Earth mat conductor and electrodes
65 x 12 mm GI Flat
40 mm dia. rod electrodes
Supply of Bay Marshalling Kiosk and support structure
Clamps & Connectors
UPG Clamps with Connectors for ACSR Panther
T Clamp With Connectors for ACSR Panther
Dove clamps for shield wires with connectors
T Clamp with connectors (Twin Panther to single)
Spacer for Panther conductor
PLCC Equipments (2 Sets)
EPAX (8x24) with 24 nos telephone, cable etc
Protection Coupler with PLC Terminal ( Duel Channel)
HF Cable
132kV , 800A wave trap for 40kA for 1 sec wave trap
Digital Carrier Terminal Equipment suitable to operate on 48V DC as per specification.
Digital teleprotection coupler with all fittings and accessories as per specification.
Telephone set (including hotline)
Co-axial Cable
Audio Cable
Description of Work / Item(s)
Amount
145kV, 3150A, SCR 40kA for 1 sec, SF6 Circuit Breaker, outdoor type, 3-ph gang operated complete with terminal connector, operating mechanism & support structure
(i)145kV Gang operated SF6 Breakers as specified above (DC -110V)
Indoor floor mounted, simplex type Control & Relay Panel with mimic & annunciation panel for 132kV feeder as per specification comprising of the C&R panels shall be complete with Numeric Relays as per the Technical Specifications & shall be compatible for SCADA/SAS as open protocol.
(i) For 132 kV Feeder Panel (Simplex Panels) as specified above
145kV outdoor type . live tank single phase Current Transformers as per the details below
(i) CTR 800-400/1-1-1-1 A ( Feeder CT)
145kV , 1-ph, Capacitor Voltage Transformer ( CVT) for 132kV line
(i) 132 kV, 132/Ö3 / 110/Ö3 /110/Ö3
145kV, 1250A, 40kA for 1 sec, 3-ph gang operated Horizntal Centre Break ( HCB) , outdoor type , motor operated Isolators including solid core post insulators , mounting structure complete with nuts, bolts , washers and foundation bolts
132 kV With single Earth Switch
132 kV Without Earth Switch
120kV, 10kA metal oxide type, heavy duty, station class-3 Lightning Arrester complete with Surge Counter & flexible copper connecting lead
132 kV Lightning Arrester
Post Insulator
132 kV Post insulator
Supply of Mounting structures of all equipment including nuts, bolts & washers ( as per enclosed drg for bidding purpose)
Current Transformers
132 kV, 800-400/1-1-1 Line CT ( 174.511kg per CT, 6x174.511kg = 1047.066kg )
Foundation Bolts (20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Capacitance Voltage Transformer
132 kV CVT( 184.393kG per CVT, 184.393x6=1106.358kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate , 1.816kg per bolt )
Lightning Arrester
132 kV Lightning Arrester ( 218.879kg per LA, 218.879x6=1313.274kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Post Insulator
132 kV Post insulator ( 219.59kg per PI, 219.59x16=3513.44kg)
Foundation Bolts ( 20mm dia, 500mm length with 125mm threaded, nut, lock nut , washer and anchor plate, 1.816kg per bolt )
Bay Steel Structures except equipment mounting structures
9.1 COLUMNS: (For Column types refer drawings)
Column Type ‘C3’ ( 2013.77+78.88=2092.65 kg per column, 2092.65x4=8055.08kg)
Foundation bolt ( 40mm dia, 1500mm length with 300mm threaded , nuts, lock nuts , washers and anchor plate, 17.55kg per fdn bolt, Total 17.55x16x4=1123.20 kg)
BEAMS: (For Beam types refer drawings)
Beam Type ‘B2 796.61+35.191=831.801kg per beam , 831.801x5=4159.005kg’
Supply of Power and Control Cables
Power Cables
4C, 4 sqmm
4C, 6 sqmm
Control Cables
Supply of ACSR Conductor
ACSR ‘PANTHER’
Disc Insulator String complete with all hardware, fittings, clamps etc.
10 Disc Tension Insulator String for twin Panther
9 Disc Suspension Insulator String
Earth mat conductor and electrodes
65 x 12 mm GI Flat
40 mm dia. rod electrodes
Supply of Bay Marshalling Kiosk and support structure
Clamps & Connectors
UPG Clamps with Connectors for ACSR Panther
T Clamp With Connectors for ACSR Panther
Dove clamps for shield wires with connectors
T Clamp with connectors (Twin Panther to single)
Spacer for Panther conductor
PLCC Equipments (2 Sets)
EPAX (8x24) with 24 nos telephone, cable etc
Protection Coupler with PLC Terminal ( Duel Channel)
HF Cable
132kV , 800A wave trap for 40kA for 1 sec wave trap
Digital Carrier Terminal Equipment suitable to operate on 48V DC as per specification.
Digital teleprotection coupler with all fittings and accessories as per specification.
Telephone set (including hotline)
Co-axial Cable
Audio Cable
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required. The erection, testing and commissioning shall be complete with Numerical relays as per technical specifications and shall be integrated with existing SCADA/SAS.
For 132 kV Feeder. (Simplex Panels)
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 800-400/1-1-1 Line CT
Erection, testing & commissioning of Voltage Transformers/CVT including laying control cables as required
132 kV, (132/Ö3) / (110/Ö3 /110/Ö3) VT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With single Earth Switch
132 kV Without Earth Switch
Erection, testing & commissioning of Lightning Arrester
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator
132 kV Post insulator
Erection of mounting structures as required for Circuit Breakers including construction of foundations and supply of all foundation materials.(as per Drg enclosed for bidding purpose)
132 kV Gang operated SF6 Breakers
Erection of mounting structures as required for Current transformers including construction of foundations and supply of all foundation materials (as per Drg enclosed for bidding purpose)
Erection of mounting structures as required for Voltage transformers /CVT including construction of foundations and supply of all foundation materials.(as per Drg enclosed for bidding purpose)
132 kV CVT
Erection of mounting structures as required for Isolators transformers including construction of foundations and supply of all foundation materials.(as per Drg enclosed for bidding purpose)
132 kV With single Earth Switch
132 kV Without Earth Switch
Erection of mounting structures as required for Lightning Arrester including construction of foundations and supply of all foundation materials.(as per Drg enclosed for bidding purpose)
132 kV Lightning Arrester
Erection of mounting structures as required for Post Insulators including construction of foundations and supply of all foundation materials (as per enclosed Drg for bidding purpose)
132 kV Post insulator
PLCC Equipment
Installation and commissioning of all equipment complete with erection of mounting structures, laying & terminations of all cables including construction of foundations & supply of foundation materials as required for following PLCC Links (excluding CVT).
Erection and Construction of foundations for lattice steel Columns including supply of all foundation materials and labour for:
Column Type ‘C3’
Erection of switchyard lattice Steel Beams:
Beam Type ‘B2’
Hoisting of insulator strings, stringing of Conductors , jumpering of equipments CB, CT, CVT Isolator, LA including supply of clamps, connectors , etc.
Installation of earthing system with GI flats, electrodes etc
Earthwork in filling, levelling, compacting, grading etc as per site condition and technical Specification
Supply of earth for filling
Filling, levelling, compacting, grading etc as per site condition and technical Specification
Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
Type B (1100 x 1050 mm)
Type C (800 x 1350 mm)
Type D (Sand filled)
PCC with Graveling (Area-1000 sq meter)
Integration of Control Relay Panel into the existing Substation Automation System (SAS)
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation materials and labour.
Erection, testing & commissioning of Digital Carrier Terminal Equipment suitable to operate on 48V DC as per specification.
Erection, testing & commissioning of Digital teleprotection coupler with all fittings and accessories as per specification.
Switchyard illumination complete(Outdoor LED flood light 100W 10 No.s)
Jayanta Khaund
M/S U.K. ENTERPRISE
Mega Electricals
ABN Tower and Transmission Private Limited
Singhi InfraPower Projects Pvt Ltd
T N T Projects Ltd
Anjali Constructions
Everlite Engineering Industries
CABCON INDIA LIMITED
HI-TECH CORPORATION
Shiv Construction
Jayanta Khaund
M/S U.K. ENTERPRISE
Shiv Construction
Anjali Constructions
ABN Tower and Transmission Private Limited
CABCON INDIA LIMITED
Duarah & Associates
Singhi InfraPower Projects Pvt Ltd
T N T Projects Ltd
Everlite Engineering Industries
HI-TECH CORPORATION
Jayanta Khaund
Singhi InfraPower Projects Pvt Ltd
ABN Tower and Transmission Private Limited
Everlite Engineering Industries
Anjali Constructions
M/S U.K. ENTERPRISE
Shiv Construction
Mega Electricals
CABCON INDIA LIMITED
T N T Projects Ltd
Duarah & Associates
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .