Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-Finance | L1 | Accepted-Finance Being accepted | |
| 2 | L2₹22.7 L+₹55,591.50 (2.51%)Accepted-Finance | L2 | Accepted-Finance L1 being accepted | |
| 3 | L3₹23.7 L+₹1.5 L (6.65%)Accepted-Finance | L3 | Accepted-Finance L1 being accepted | |
| 4 | L4₹23.7 L+₹1.5 L (6.66%)Accepted-Finance | L4 | Accepted-Finance L1 being accepted | |
| 5 | L5₹24.2 L+₹2.0 L (9.06%)Accepted-Finance | L5 | Accepted-Finance L1 being accepted |
Tender Value
₹20 L
Closing Date
7 Aug 2021, 5:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR REPLACEMENT MAINT OF LT EXT ELECT SUPPLY AND UG CABLES INCL CONTROL PANELS AND OTHER CONNECTING ALLIED WORKS AT MH MD AREA UNDER GE GOLCONDA
2021_MES_460698_1
CA No. GE/Gol/32of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE GOLCONDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GOLCONDA
Exempted
21 Aug 2021
17 Jul 2021
10 Aug 2021
17 Jul 2021
7 Aug 2021
31 Jul 2021
17 Jul 2021 - 29 Jul 2021
Amount
M & L Pre-stressed concrete pole, 9 m long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10 including taking down carefully the exisitng unserviceable pole, serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. Note: Excavaation, earthwork and PCC in foundation shall be measured and paid separately under relevant item.
M&L for PCC 1:4:8 type D2 as in foundation and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
Supply & Lay in trenches/ fixed to walls/ poles etc., testing and commissioning XLPE insulated PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable with stranded aluminium conductor of size 10 Sqmm 2 core including taking out of existing cable all as specified and directed.
Ditto all as per item No 3 above but for 4 Core 16 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 25 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 35 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 50 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 70 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 95 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 120 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 150 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 185 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 240 Sqmm Note for item 3 to 13 :- Earth work & excavation required shall be measured and paid separately.
S & L 100 mm bore GI tubing , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
Ditto all as per item No 14 above but for 80mm bore.
Ditto all as per item No 14 above but for 50mm bore.
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for 35 to 70 Sqmm 3.5 core complete including taking out old unserviceable cable end termination jointing kit for 1.1 KV all as specified and directed.
Ditto all as per iem No. 17 above but for 95 Sqmm to 150 Sqmm 3.5 core
Ditto all as per iem No. 17 above but for 185 Sqmm to 240 Sqmm 3.5 core
S & F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for 35 sqmm to 70 sqmm 3.5 core cable complete including taking out old unserviceable one all as specified and directed.
Ditto all as per item No. 20 but for cable 95 sqmm to150 sqmm
Ditto all as per item No. 20 but for cable 180 sqmm to 240 sqmm
Supply, fixing and stringing Aluminium Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator complete, on overhead line including taking down of existing conductor all as specified and directed.
Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed .
S&F stay assembly complete with accessories as shown in electric plate No.1, stay rod 16mm dia including loop type insulator, stay clamps, and also including taking out old unserviceable one all as specified and directed. (Note: Excavation & earthwork and PCC foundation shall be measured and paid separately.)
M&L MS cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers welding bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint, including removing the existing cross arms etc complete all as specified and directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulators all as specifeid and directed.
M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing one etc complete all as specified and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and clearing the distance 1.5 mtr either sides of overhead line removing the waste (branches etc) off the site all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles / cables / pipes in trenches etc and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread crushed stone sand for cushioning of cable laid in trenches complete all as specified and directed. Note:- Punned thickness will be measured for payment purpose.
M&L burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as directed by Engineer-in-Charge.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm
M & L cutting of road, hard standing of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/ hard standing by using all old/ new materials and with PCC (1:2:4) etc. complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation in any starta, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
S&F PVC separators suitable for LT over head line of 4 conductors complete all as specified and directed.
M&L MCCB 415 Volts, 4 pole, fixed type, 100 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 320 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L for cleaning thoroughly LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt / rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
M&L for cleaning thoroughly the two pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
Removing Existing unserviceable Analog voltmeter with electrical connections and supply, install and test the new voltmeter 0-500V all as directed and speicified at site.
Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new ammeter 0-250A/100A with necessary wires all as directed and speicified at site.
Note for item No 47 : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands, nuts & bolts etc the cost of which is deemed to be included in the above item.. (b) The cost shall also deemed to include for breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. (c) The panel shall be fabricated from a reputed firm(CPRI Approved) .
Removing Existing unserviceable Advance power factor controller and supply and fix Advance power factor controller 12 Segment including comprehensive displays with large, three- digit LED display, 3 Logics (1:1:1), (1:2:2), (1:2:4) to connect banks, with automatic recognition or with standards programs RS-485 Communication with electrical connections all as directed and specified at site.
S&F in repair suitable size Indoor cubicle type MCCB enclosure (on wall with necessary screws, lugs etc.) made out of 2 mm thick CRCA sheet single door, front open type, and painting with one coat of red oxide primer and two coats of powder coated paint for MCCB capacity 100 to 160 Amps with provision for entry /exit of suitable 3.5 core LT Cable and connecting incoming & outgoing LT cables complete all as specified and directed.
Disconnecting and removing the U/S switch air break gang operated system Out Door Type from the existing position and S&F air break switch gang operated triple pole mechanical operated, vertically or Horizontally mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 400 AMPs, 11000 Volts with locking arrangement incl connecting and testing, Air Break Insulators (Switch) complete all as specified and directed.
Labour only for replacement of defective wiring with copper wire of suitable size including replacement of electrical/ electronic parts of AMF panel of DG Set 200 KVA, including lugs, sleeves etc complete all as directed. Note: Electrical/ Electronic spare parts shall be measured and paid separately.
Supply only DG AMF Panel Controller Unit of Model No. DGC-6D, suitable for DG Set 200 KVA of Engine Kirlosker Cummins Ltd.,
Supply only Relay Chord ( 2+1 )
Supply only Push buttons & Elements.
Removing Existing unserviceable Capacitors upto 4 KVAr with electrical connections and supply and install New MPP -S heavy duty capacitors all as directed and specified at site. Make : neptune power 9 heavy duty capacitors/Equivalent
All as per item No. 57 above but for 5/7.5/10 KVAr capacity.
SANJEEV CONSTRUCTIONS
M/S Veerabhadra Constructions
BUILDWEL
MOHAMMED MUMTAZ ENGINEERING WORKS
m/s s indra reddy constructions
Sri Lakshmi Enterprises
Sri Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .