Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 2 | Accepted-Technical | Accepted-Technical technically qualified |
| 3 | Rejected-Technical | Rejected-Technical technically not qualified |
| 4 | Rejected-Technical KANDLI TQ ACHALPUR DIST AMRAVATI | ACHALPUR | AMRAVATI | MAHARASHTRA | Rejected-Technical technically not qualified |
| 5 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
₹2.3 Cr
Closing Date
26 Feb 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PD ATMA YAVATMAL
Project Director ATMA,Samvidhan Square,Garden Road,Yavatmal
Construction of Godown 1800 MT And Machine Shed 225.70 Sqm
2026_DOAWB_1272030_1
SMART/YTL/LANG/CIVIL/RE/2026
Open Tender
Warehouse
Item Rate
365 days
at shahapur tq ner dist yavatmal
as per tender doc
2 documents required · 2 mandatory
₹2,360
Exempted
PD ATMA Yavatmal
6 May 2026
28 Jan 2026
27 Feb 2026
28 Jan 2026
26 Feb 2026
28 Jan 2026
28 Jan 2026 - 26 Feb 2026
11 Feb 2026
BUILDING STRUCTURE
Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation, and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift up to 1.5 m.) By Mechanical Means WAREHOUSE BUILDING- 261.90 PROCESSING UNIT-68.04 TOTAL QTY- 329.94
Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting, etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means WAREHOUSE BUILDING- 226.44 sqm PROCESSING UNIT-0.00 sqm TOTAL QTY- 226.44 sqm
Excavation for foundation in Hard murum in cluding removing the excavated material upto adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-27.22 TOTAL QTY- 27.22
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 cm to 20 cm thick including hand packing and compacting complete.WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-48.51 TOTAL QTY- 48.51
Filling in plinth and floors with approved excavated material in 15cm to 20cm layers, including watering and compacting, etc. Complete. WAREHOUSE BUILDING- 54.48 PROCESSING UNIT-95.26 TOTAL QTY- 149.74
Filling in plinth and floors with contractor's material/brought from outside and approved by Engineer in charge in layers of 15cm to 20cm including watering and compaction etc. complete. WAREHOUSE BUILDING- 1170.54 PROCESSING UNIT-158.17 TOTAL QTY- 1328.71
Providing soling using 80mm size trap metal in 15cm layer including filling voids with crushed sand/grit, ramming, watering, etc. complete. WAREHOUSE BUILDING- 238.74 PROCESSING UNIT-0.00 TOTAL QTY- 238.74
Providing pre-constructional anti-termite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorpyrifos per one square metre of vertical surface area covering 10 years guarantee on bond paper WAREHOUSE BUILDING- 1509.93 PROCESSING UNIT-0.00 TOTAL QTY- 1509.93
(P.C.C. FOR FOOTING ) Providing and laying cast in-situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, and curing complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) WAREHOUSE BUILDING- 118.10 PROCESSING UNIT-27.11 TOTAL QTY- 145.21
(FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 69.42 PROCESSING UNIT-0.00 TOTAL QTY- 69.42
( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 44.77 PROCESSING UNIT- 0.00 TOTAL QTY- 44.77
( PLINTH BEAMS CONCRETE ) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 23.80 PROCESSING UNIT-0.00 TOTAL QTY- 23.80
(FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-14.18 TOTAL QTY- 14.18
( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-5.29 TOTAL QTY- 5.29
( PLINTH BEAMS CONCRETE ) Providing and laying Cast in situ/Ready Mix cement concrete in M-20. of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-10.40 TOTAL QTY- 10.40
( PLATFORM LANDING CONCRETE ) Providing and laying Cast-in-situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). With fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). WAREHOUSE BUILDING- 6.48 PROCESSING UNIT-0.00 TOTAL QTY- 6.48
Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches, etc. as per detailed designs, drawings, and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required, complete. WAREHOUSE BUILDING- 18.23 PROCESSING UNIT-1.86 TOTAL QTY- 20.09
( TREMIX FLOOR CONCRETE WORK ) Providing and layingin situ cement concrete M20 with TREMIX TREATMENT for 100 MM thickness for flooring with groove cutting of 4mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. WAREHOUSE BUILDING- 975.45 sqm PROCESSING UNIT-210.90 sqm TOTAL QTY- 1186.35 sqm
(Brick Work) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls, including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces, and watering, etc. Complete WAREHOUSE BUILDING- 17.44 PROCESSING UNIT-7.63 TOTAL QTY- 25.07
( BRICK WORK ) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete WAREHOUSE BUILDING- 76.70 PROCESSING UNIT-19.23 TOTAL QTY- 95.93
( INTERNAL PLASTER ) Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, etc. complete. WAREHOUSE BUILDING- 357.00 PROCESSING UNIT-142.05 TOTAL QTY- 499.05
( EXTERNAL PLASTER ) Providing sand-faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag, curing the same for not less than 2 days, and keeping the surface of the base coat rough to receive the sand-faced treatment 6 to 8mm thick in cement mortar 1:4, finishing the surface by taking out grains and curing for fourteen days, scaffolding, etc. Complete. WAREHOUSE BUILDING- 700.74 PROCESSING UNIT-210.24 TOTAL QTY- 910.98
( INTERNAL PAINTING WORKS ) Providing and applying white-wash in two coats on old/newplaster do rmasonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. WAREHOUSE BUILDING- 346.20 PROCESSING UNIT-210.24 TOTAL QTY- 556.44
(EXTERNAL PAINTING) Providing and applying plastic emulsion paint of approved quality, colour, and shade to old and new surfaces in two coats, including scaffolding, preparing the surface. (Excluding the primer coat) etc. Complete WAREHOUSE BUILDING- 700.74 PROCESSING UNIT-210.24 TOTAL QTY- 910.98
(SIDE VENTILATOR) Providing and fixing steel ventilator fully glazed, partly fixed as per detailed drawing, with hot-dip zinc coating, including fabricating glazing with plain/obscured glass panes 5mm thick and approved type quality, and iron oxidized fixtures and fastening with guard square bars 12 mm, 10 cm c/c, and oil painting 2 coats, etc. Complete. WAREHOUSE BUILDING- 41.40 PROCESSING UNIT-14.40 TOTAL QTY- 55.80 sqm
Providing neeru finish to plastered surfaces in all position s including scaffolding and curing etc. complete WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-142.05 TOTAL QTY- 142.05
Providing and applying primer coat for internal wall surfaces and ceilings including scaffolding etc. complete. WAREHOUSE BUILDING- sqm PROCESSING UNIT-142.05 sqm TOTAL QTY- 142.05 sqm
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. WAREHOUSE BUILDING- sqm PROCESSING UNIT-142.05 sqm TOTAL QTY- 142.05 sqm
Structural Steel
Supplying, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe490) conforming to IS:2062 - 2006. Rate shall include cost of cutting, welding, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position welded/bolted Structural steelwork in columns, beams, trusses, purlins, platforms, ladders, monorails, staircases ,supports, strengthening of steel members etc. at site to line and level, supply of approved bolts/nuts/washers etc. complete as per drawings including painting as per G4/G5/G6 before erection and all materials and labour charges etc., complete and including Sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG – HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / Construction Manager. (The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes required for the complete work). WAREHOUSE BUILDING- 26.00 PROCESSING UNIT-0.00 TOTAL QTY- 26.00
Supplying, fabricating and erecting of Cold Formed Light Gauge structural steel members conforming to IS:801/ IS:811 hot-dip galvanised to IS:4759 - 96 including cutting, welding or bolting, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position. WAREHOUSE BUILDING- 9.50 PROCESSING UNIT-0.00 TOTAL QTY- 9.50
Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by engineer incharge with all necessary accessories.(Essar) Make) WAREHOUSE BUILDING- 1195.66 PROCESSING UNIT-514.97 TOTAL QTY- 1710.63
Supply & Fixing of 0.5 mm thk PPGL roof accessories as per drawing or as directed by engineer incharge- WAREHOUSE BUILDING- 189.40 PROCESSING UNIT-0.00 TOTAL QTY- 41.40
Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer incharge WAREHOUSE BUILDING- 87.72 PROCESSING UNIT-0.00 TOTAL QTY- 87.72
Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / WAREHOUSE BUILDING- 72.00 PROCESSING UNIT-0.00 TOTAL QTY- 72.00
Supply & Fixing of 2mm thk polycarbonate sheets as per drawing & as directed by engineer in-charge.WAREHOUSE BUILDING- 21.72 PROCESSING UNIT-20.70 TOTAL QTY- 41.40
Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of2mm thk clear 1.020 mtr wide & 1.7 mtr long.WAREHOUSE BUILDING- 12.00 PROCESSING UNIT-6.00 TOTAL QTY- 18.00
Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing, including hinges, pivot block, locking arrangement, welding, riveting, and oil painting of three coats of approved shade. Weight of gate: 35 Kilogram/Square Meter. WAREHOUSE BUILDING- 10.08 PROCESSING UNIT-0.00 TOTAL QTY- 10.08
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness, reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with holdfast arrangements, M.S. Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high-grade cast iron or mild steel and one coat of red lead primer, etc. complete. (I.S. 6248-1979) (Without mechanical gear) WAREHOUSE BUILDING- 38.40 PROCESSING UNIT-10.50 TOTAL QTY- 48.90
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anti corrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. WAREHOUSE BUILDING- 0.00 PROCESSING UNIT-8.52 TOTAL QTY- 8.52
Bituminous Road Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land)
(ROAD MUROOM ) Supplying hard murum / kankar at the road site , including conveying and stacking complete.
(MUROOM SPREADING ) Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths, including laying in layers on each side with a vibratory roller, including artificial watering, etc. Complete.
Providing, laying, spreading, and compacting stone aggregates of specific sizes to water-bound macadam specification, including spreading in uniform thickness, hand-packing to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading I (Using Screening Type B (11.2 mm) Aggregate).
Providing, laying, spreading, and compacting stone aggregates of specific sizes to water-bound macadam specification, including spreading in uniform thickness, hand-packing to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate).
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including all mataerials, preparing the existing road surface, spreading 40mm.stone metal layers 30% crusher broken metal and 70 % Hand broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 2 kg/sqm, spreading 12mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates)3
Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk bitumen rates are considered to arrive at rates) ITEM NO.4.12
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Electrification
Providing and fixing lioghtening conductor system comprising of erecting Air - Termination consisting of tubular copper rod of 25 mm dia.1.2 mm thick with multiple point shead 1.2mt.long (Heavy Duty)welded or clamped to G.I. pipe pole B grade 50 mm dia of required length with M.S . round base plate 25 Cm diamand 10 mm thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 cm dia m x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cad mium plate nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and G.I. pipe 40 mm dia2 meter length burried in earthing plate remining portion above ground level for watering and refilling comcpete Note-Copper strip from lightening conductor is not considered in this item.
Providing and fixing copper strip 25 mm wide and 3 mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthin pits is not considered in this item
Supplying and errecting HMS PVC conduit FRLS Grade 25 mm dia. With pvc accessorieson wall/ ceilling as per specification No. WG-MA/ CON
Supplying and errecting mains with 1X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any other places as per specification No. WG-MA/CON
Supplying and errecting mains with 2X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any other places as per specification No. WG-MA/CON
Supplying and errecting mains with 2X2.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any other places as per specification No. WG-MA/CON
Supplying and errecting modular type 3pin 6/16 A multy sockets with safety shutter, duly errected on provided plate and box with wiring connections complete
Supplying and errecting PVC surface maodular switch box with double mounting plate for 6 module duly errected
Supplying and errecting PVC surface maodular switch box with double mounting plate for 12 module duly errected
Supplying and errecting street light wall bracket made from 40 mm dia G I pipe 1.2 m in total length complete as per specification no FG- BKT/WB
Supplying, errecting and marking SPMCB 6A to 32 A, C series with rated short - circuit braking capasity 10kA in provided distribution board as per specification no SW-SWR/MCB
Providing earthing with galvnised iron earth plate size 60 X 60 C 0.6 cm complete with all materials, testing and recording the resuilt as per specification no EA-Ep
Royalty for Sand
Royalty for murum and Other material
QUALITY CONTROL & LAB TESTING
M25 CONCRETE: Concrete Mix Design (With all Tests on basic materials)
M25 CONCRETE: Compressive Strength OF C.C. Cube (Set of 3
M20 CONCRETE: Concrete Mix Design (With all Tests on basic materials)
M20 CONCRETE: Compressive Strength OF C.C. Cube (Set of 3
M10 CONCRETE: Compressive Strength OF C.C. Cube (Set of 3 cubes).
BRICKS :Water Absorption (Set of 5 Bricks), Compressive strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks)
TMT STEEL : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Sand :- i) Fineness Modulus, II) Silt content
Murum :- ii) Atterberg Limit iii) Density of compacted layeriv) Proctor Test
Bitumen Penetration, Softening Point, Flash & Fire Point, Specific Gravity, Viscosity.
Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
Cement Test i) Comprecive strengh ii) Intital and final setting time iii)Spcific Gravity iv) Spicific Gravity v) soundness vi) Finess
METAL Gr I & Gr II Agrregates AIV Test, Gradation,Water Absorpation Test,Crushing Value
Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tenderdoc.pdf
Tender Documents • 1.39 MB
BOQ_2190058.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .