Arrangements for providing of oxygen facility including shifting/ transportation of Bulk D type cylinders to Sonmarg / Baltal / Panjtarni/ Lower Cave/ Upper Cave during SANJY 2026.
2026_PWDJK_311829_1
MHDH/TS/2026-27/eNIT/08
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
5 days
Sonmarg
as per NIT
3 documents required · 3 mandatory
₹500
Executive Engineer MHD Handwara
₹57,400
15 Jun 2026
8 Jun 2026
15 Jun 2026
8 Jun 2026
15 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Medical Gas Pipeline System
Provision for Providing, Fitting & Testing of a new 4 way/point Oxygen Manifold system with angle iron base comprising of not less than below items at Uppercave/Lowercave/Panjtarni:
(i) High pressure copper pipe.
(ii) High pressure Brass fittings.
(iii) Non Return Valve (NRV).
(iv) High pressure Copper/SS braided Tail Pipes 4 Nos.
(v) High Pressure Oxygen Regulator with pressure guages 01 Nos. | 2 | job | - | - |
| 2 | Installation of dismantled Oxygen Manifold including pipeline system along with Oxygen Outlet points at Upper Cave and Lower Cave temporary structure. The Job includes labour, carriage, tools and tackles cost. | 2 | job | - | - |
| 3 | Provision for Providing, Fitting & Testing of a High pressure Copper/SS braided Tail Pipes for manifold. | 7 | job | - | - |
| 4 | Provision for Repair of leaks druing Yatra Period in manifold, copper tubes and oxygen outlets by way of engaging skilled labour at Uppercave/Lowercave/Panjtarni for detection and rectification of leaks. The Job includes labour, carriage, tools and tackles cost. | 2 | Trips | - | - |
| 5 | Additional requirement of Copper tubing by way of providing, fitting & testing of seamless copper tubing of following diameters, solid drawn of thickness 0.9mm for oxygen line. The medical grade copper tubing shall be seamless hard tempered.The job includes cutting of copper tubing, silver brazing, polishing, providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc. The copper tubing shall be fitted on the wall with the help saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.
15 mm | 30 | mtr | - | - |
| 5.01 | 12 mm | 20 | mtr | - | - |
| 6 | Providing, fitting and testing of new PB type oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings complete in all respects. (6 new flow meters at every site) | 20 | No | - | - |
| 7 | Replacement of damaged Oxygen outlet points by way of supply, installation, testing & commissioning of Oxygen PB type Gas outlets properly cleaned for medical gas service. Each outlet will have less than 3 psi (21KPa) pressure drop through the outlet @ 120 l/min. and 50 psig (345KPa) inlet pressure. For outlets providing positive pressure gas, the outlet will be equipped with a primary and secondary check valve will be rated for 200psi (1,379 kPa) allowing the primary check valve to be removed for services without isolating the entire zone. The wall outlets will have a gas specific back body with steel mounting plate, which allows outlets to be ganged together with a center line spacing of 5” (127mm). Each back body will be equipped with a 6½” (165mm) length type “K” copper pipe stub which is brazed to the outlet body. The inlet pipe can be swiveled 360 degrees for ease of installation. | 15 | job | - | - |
| 8 | Replacement of damaged isolation valve by way of supply, installation, testing & commissioning of brass metal ball type Isolation Valves of following diameters. The job includes fitting of the valve on the pipeline by means of brazing with silver electrode along with necessary fittings required to complete the job. 12mm | 15 | No | - | - |
| 9 | Modification of the site for cylinders at Upper Cave by engaging labour for leveling and dressing of the area to enable easy placement of cylinders near the manifold, including all labour, tools and tackles required for completion of the work, complete in all respects as directed by the official-in-Charge. | 1 | job | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 0.53 MB
BOQ_1009565.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .