| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹90.7 LAdmitted-Finance | -31.01% | ₹90.7 L | L1 | Admitted-Finance |
| 2 | L2₹96.4 LAdmitted-Finance | -26.71% | ₹96.4 L | L2 | Admitted-Finance |
| 3 | L3₹1.1 CrAdmitted-Finance | -15.00% | ₹1.1 Cr | L3 | Admitted-Finance |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
19 Jan 2026, 4:00 pmClosed
Er Rajesh Kumar
Executive Engineer PWD R and B Division Basohli
Please refer in BOQ
2026_PWDJK_300326_1
e-NIT No.52 of 2025-26 Dated 10-01-2026
Open Tender
Civil Works
540 days
Basohli
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Executive Engineer PWD R and B Division Basohli
₹2.6 L
Executive Engineer PWD R and B Division Basohli
20 Jan 2026
10 Jan 2026
20 Jan 2026
11 Jan 2026
19 Jan 2026
13 Jan 2026
12 Jan 2026
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
All kinds of soil = 95%
Ordinary rock =5%
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : In all kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: a) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:4:8 (1 cement:4 coarse sand:8 graded stone aggregate 40mm nominal size).
Providing & fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases etc. including hoisting and setting in position with cement mortar 1:3 (1 cement:3 coarse sand) cost of required centring, shuttering and curing complete a) 1:1½:3(1 cement :1½ coarse sand :3 graded stone aggregate 20 mmnominal size)
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centring ,shuttering, finishing and reinforcement. All work upto plinth level with: a) 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. a) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with: a) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 5.5.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting propping etc. and removal of form work for:-
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Shelves (cast-in-situ)
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Columns, pillars, piers, abutments, posts and struts.
Stairs (excluding landings) except spiral staircases.
Edges of slabs and breaks in floors and walls under 20cm wide.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). a) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:6 (1 cement:6 coarse sand).
Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level.
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : a)Cement mortar 1:3 ( 1 cement : 3 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). a) Sal Wood.
Dash fastner/ Chemical fastener
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. i) Float glass panes. a) 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm)
Providing and fixing 35mm ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a)With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
Extra for providing vision panel not exceeding 0.1 sqm in all types of flush doors (Cost of glass excluded) (overall area of door shutter to be measured): a) Rectangular or square
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. A) Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : a) 250x10 mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete. : a) 300x16x5 mm
Providing and fixing bright finished brass handles with screws etc. complete : a) 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made a) Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. a) Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Float glass panes of nominal thickness 5 mm (weight not less than sqm 450.00 12.50 kg/sqm)
Float glass panes of nominal thickness 8 mm (weight not less than 20.00 kg/sqm)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. A) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. A) M.S. tube
Providing and laying vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. a) Size of tile 600x600mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. a) Size of tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 sqm sqm 11.68 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. A) Granite Work
Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3kg/sqm including pointing in white cement with curing complete. a) Granite of any colour and shade
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks)
12mm cement plaster of mix. 1:6 (1 cement:6 fine sand).
15mm Cement plaster on the rough side of single or half brick wall of mix: a) 1 : 6 ( 1 cement : 6 fine sand)
6mm cement plaster to ceiling of mix. 1:3 (1 cement:3 fine sand).
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as permanufacturers’ specifications: a) Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. A) 2 mm thick
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. A) With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. A) Two coat
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
French spirit polishing, Two or more coats on new works including a coat of wood filler
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: a) Two or more coats on new work.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: a) 1:4:8 or leaner mix (i/c equivalent design mix).
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: a) In cement mortar
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : a) Of area of 3 sqm. and below
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge. 23.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
6 mm thick High performance glass
ARMS GS HD -TOP HUNG -20"-TYPE P-COUPLE
Weather Sealant - DC 789
Providing and fixing white vitreous china pedestal type water closet (Euorpean type) with seat and lid, 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and CI brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. a) W.C. pan with ISI marked white solid plastic seat and lid. (Jaguar/Cera)
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : a) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610x390x370mm having pre & post flushing with water (250 ml & 500 ml consumption ), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Jaguar/Cera)
Providing and fixing stainless A ISI 304 (18/8) kitchden sink as per IS 13983 with CI brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherequired: a) Kitchen sink with drain board. i) 510x1040mm bowl depth 250mm.
Providing and fixing mirrior of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. A) Rectangular shape 1500x450mm
Providing and fixing toilet paper holder with flap made out of CP brass. (Jaguar/Cera)
Providing and fixing 8mm dia CP / SS jet with flexible tube upto 1 metre long with SS triangular plate to Euorpean type W.C. of quality and make as approved by Engineer-in-charge.
Providing and fixing brass bib cock of approved quality. A) 15 mm nominal bore
Providing and fixing 15mm nominal bore CP brass angle valve for basin mixer and geyser points of approved make conforming to IS:8931. (Jaguar/Cera)
Providing and fixing CP brass 32mm size bottle trap of approved quality and make and as per the direction of Engineer-in-charge.
Providing and fixing stainless steel Retractable sink basin water drain pipe of approved quality and make and as per the direction of Engineer-in-charge (For Kitchen sink). (LMR)
Providing and fixing CP brass sink mixer with regular swivel spout of quality & make as per approved by Engineer-in-chare. (Jaguar/Cera) (LMR)
Providing and fixing soil, waste and vent pipes IS 13592 and fittings (IS:14735) suitable to rubber ring joints, which includes bends, rubber ring, jointing, junctions, clean out plug, cowls, offsets, collar, M.S. holder bat clamps, access piecess, trap of self cleaning design etc. complete including jointing.
110mm dia PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B (LMR)
75mm dia PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B (LMR)
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes a) 110 mm diametre
Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
i) Coupler : a) 110 mm
Bend 87.5° : a) 110 mm bend
Shoe (plain) : a)110 mm shoe
Providing and fxing of floor traps 110mm with double chrome plated cover one Grated and one closed and all other fittings required. Maker:Astral/SFMC/Finolex. (LMR)
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Supply, Installation of PVC Gully Trap of size 110 mm. (LMR)
Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: a) Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc.
a) 1620 (20mm OD) pipe
2025 (25mm OD) pipe
Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: a) Internal work-exposed on wall with clamps at 1.00 meter spacing.
a) 2025 ( 25mm OD) pipe
2532 ( 40mm OD) pipe
Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: a) External work including trenching and refilling etc. complete. a) 4050 ( 50mm OD) pipe
Providing and unplasticised PVC connection pipe with brass unions: 45cm length. A) 15mm nominal bore.
Cutting holes up to 30x30 cm in walls including making good the same: a) With common burnt clay (non modular) bricks
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): a) 32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing and fixin on wall 35 Ltrs. Electric Geyser with ABS body. (LMR)
Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
Sand from Billawar for an av. lead of 60.00 km. by M.T.
Stone aggregate (Crusher bajree) below 40mm nominal size from Billawar for an av. lead of 60.00 km. by M.T.
Stone aggregate 40mm nominal size & above from Billawar for an av. lead of 60.00 km. by M.T.
Disposal of Earth for an av. lead of 1.00 km. by M.T.
Bricks from Kathua for an average lead of 85.00 Km. by M.T.
Lime, moorum, building rubbish for an av. Lead of 1.0 km. by M.T.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_974262.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid