| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.3 L+₹3,780 (0.18%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.6 L+₹2.3 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.3 L+₹4.0 L (18.9%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹25.8 L+₹4.6 L (21.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30.0 L
EMD Value
₹59,960
Closing Date
30 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-11/2022-23 CERTAIN PETTY REPAIR OF E/M COMPLAINT OF INTERNAL ELECTRIC SUPPLY AT PCDA(NC) OFFICE AND RESIDENTIAL COMPLEX UNDER GE(AF) JAMMU
2022_MES_536903_1
CA NO GE/AFJ-11/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Jammu
₹59,960
Yes
12 Oct 2022
9 Jul 2022
1 Aug 2022
9 Jul 2022
30 Jul 2022
23 Jul 2022
Amount
Attending complaints for checking of existing electrical points wiring upto size 6 sqmm in any Buildings for continuity ,no light including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified.Note- Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all working days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor. Note : a ) Contractor shall provide his tadesmen/labour along with necesary tools to rectify defects from 0830 to 1700 Hrs on all working days. (b) One complaint shall be considered as Each Job c) The contractor shall depute ITI holder electrician & skiilled helper to attend complaints, with proper uniform as finalised by Engr-in-Charge, with name tag. (d) Material required for attending complaints will be given as supply only item. ( e) Any parts required to be replaced shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule.
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
M&L for point wiring for light/fan/Bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc
All as per item No.3 above but for one multipin 5 amps socket outlet on same board complete all as specified and directed.
All as per item No.3 above but for one multipin 5 amps socket outlet on independent board complete all as specified and directed.
All as per item No . 3 above but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent boardcomplete all as specified and directed.
Supply only switch piano button flush type, single pole one way 5 amps complete all as specified.
Supply only switch bell push piano flush button single pole one way 5 amps complete all as specified and directed.
Supply only piano switch two way flush button 5 amps complete all as specified and directed.
Supply only 5 pin socket outlet 2 in 1, 3 pin, 5 amps flush type complete all as specified and directed.
Supply only 5 pin switch socket combination 2 in 1, 5 amps flush type complete all as specified and directed.
Supply only switch socket combination 5 in 1, 5 and 15 Amp flush type controlled by one switch complete all as specified and directed.
Supply only ceiling rose, 3 phase on PVC square blocks surface bakelite 65 x 50 mm, 3 terminal complete all as specified and directed.
Supply only Lamp holder, PVC/Polycarbonate type with back plate and 12W LED Lamp suitable for batten fittings complete all as specified and directed.
Supply only flush type fan regulator 230V, electronic rotary stepped increase complete all as specified and directed.
Supply only Call bell ding dong AC, 23 Volts, single pole type complete all as specified and directed. .
Supply only Switch Modular (piano) flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed.
Supply only Switch Modular (piano) flush button single pole one way 16 amps with suitable plate and cover complete all as specified and directed.
Supply only Socket outlet flush modular (piano) type 5 pin 6 Amps with suitable plate and cover complete all as specified and directed.
Supply only Socket outlet flush universal modular (piano) type 6 pin 6/16 Amps with suitable plate and cover complete all as specified and directed.
Supply only three modular sheet fitting .
Supply only four modular sheet fitting .
Supply only Six modular sheet fitting .
Supply only twelve modular sheet fitting .
Supply only modular 6 Amps socket .
Supply only modular 16 Amps socket .
Supply only copper wire 1.5 Sqmm green colour single core . Make:-Anchor/Havells/Polycab
Supply only copper wire 2.5Sqmm green colour single core Make:-Anchor/Havells/Polycab
M&L for sub main wiring with two run of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 25 mm wide & 6 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.Make of wire-- Finolex/Havells/Plaza.
Description all as per item No.29 above but size 4 Sqmm two runs and with 4 sqmm FRLS copper wire for earth continuity. Make of wire-- Finolex/Havells/Polycab/Plaza..
Description all as per item No.29 above but size 2.5 Sqmm two runs and with 2.5 Sqmm FRLS copper wire for earth continuity. Make of wire-- Finolex/Havells/Polycab/Plaza..
Supply only LED tube light fitting 18/20 watt wall mounted LED batten with aluminum housing & integrated electronic drivermake-Cat Part- CCS 102-20-65-SLDPNWH Crompton & equivalent to Philips/Wipro.
Supply only LED tube light fitting 9/10 watt wall mounted LED batten With aluminum housing & integrated electronic driver Make- Cromptonor/Philips/Wipro
Supply and fixing in repairs by flushing to walls MCB distribution board Double door SPN 230 volts 12 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc Make- Legrand/Havells/L&T/Indio asian
Supply and fixing in repairs by flushing to walls MCB distribution board Double door SPN 230 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc Make- Legrand/Havells/L&T/Indio asian
Supply and fixing in repairs by flushing to walls MCB distribution board double door 240 volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls. Make- Legrand/Havells/L&T/Indio asian
Supply and fixing in repairs distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge Make- Legrand/Havells/L&T/Indio asian (Note: MCB's and MCCB will be measured and paid separately under relevent items)
Supply only MCB SP 6 to 32 Amps, 240 Volts complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
Supply only MCB SPN upto 32 Amps ,240 Volts complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
Supply only MCCB TPN 100 Amps ,415 Volts complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
Supply only MCCB TPN 125 Amps ,415 Volts complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
Supply only MCB SPN 63 Amps, 230 V,AC complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
Supply only TPN 63 Amps 415 V complete all as specified and directed. Make- Legrand/Havells/L&T/Indio asian
M & L metal socket enclosure with 240 volt MCB 20 Amps, with metal plug top complete all as specified incl taking down old unserviceable one. Make ABB/Legrand/ L&T.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Supply only 10 Watt energy efficient wall mouted LED Bulk head luminaire made off die cast aluminium with opal diffuser Make- Crompton/Philips/Wipro incl taking down old UNSV.
Supply only 36 watts recess /pendant mounting ultraslim LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser Make-Crompton/Philips/Wipro incl taking down old UNSV.
Supply only round sheet for blank area 2.5 " dia and 3 "
S & F in repair MCCB Three pole 415V 125 Amps 16 kA complete all as specified and directed.
S & F in repair MCCB Three pole 415V 200 Amps 25 kA complete all as specified and directed.
S & F in repair MCCB Three pole 415V 250 Amps 25 kA complete all as specified and directed.
M&L in repair of PVC Boards closed recessed of size 4x4x2 inches complete all as specified and directed.
M&L in repair of PVC Boards closed recessed of size 4x7x2 inches complete all as specified and directed.
M&L in repair PVC Boards closed recessed of size 8x10x2 inches complete all as specified and directed.
M&L in repair of PVC Boards closed recessed of size 10x12x2 inches complete all as specified and directed.
Supply only PVC electrical insulation tape width 25-30mm and length 35-40 mtrs
Supply only PVC Gang box two way or one way for shifting of 5A/15 Amps switch & socket etc complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Supply only 9 watts LED Bulb Make Wipro/CE/Havells/Siska
Supply only 18 way modular box
Supply only 14 way modular box
Supply only 12 way modular box
Supply only 6 way modular box
Supply only 4 way modular box
Supply only 3way modular box
Taking down carefully the existing unserviceable ceiling / Exhaust fans/ Wall mounted fan of any make/ model and sweep from different sites in the building for overhauling / servicing after disconnecting carefully cleaning and checking unserviceable components, and replacing the defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor burnt windings flexible cord, shaft and painting etc., including assembling after lubricating the movable components and installing in its original position connecting, testing and commissioning all as specified and directed by the Engineer-in-charge. Note:- Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexiable / stator/rotor and painting only will be measured and paid separately under respective item.
M & L for rewinding of ceiling fans 1200/1400mm sweep of any make/model, including removal of existing burnt windings carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enmelled copper winding wire of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush,rubber bush/bolt, capacitor,flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed for :- Note :-(1) Fan will be issued from AGE E/M store yard through gate pass.(2) Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexible / stator/rotor and painting only will be measured and paid separately under respective item.
All as per item no 67 above but exhaust fan of 450/375/300mm sweep of any model/make.
All as per item no 67 above but pedestal fan of any sweep of any model/make.
All as per item no 67 above but Wall mounting fan of any sweep , any model/make.
Supply only fan motor 150W 1500 RPM suitable for Exhaust fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG/Bajaj/Havells
Supply only fan motor 150W 1500 RPM suitable for Padestal fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG/Bajaj/Havells
Supply only fan motor 90W 1500 RPM suitable for Wall Mounting fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG/Bajaj/Havells
Supply only ball bearing suitable for any fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make TATA, SKF
Supply only gunmetal bush suitable for ceiling fan / wall mounting fan of any make/model/ sweep of 1200/1400 mm and Exhaust fan of any sweep all as specified and directed by the Engineer-in charge.
Supply only twin core PVC flexible copper conductor of size 23/0076 all as specified and directed by the Engineer-in-charge
Supply only capacitor of 2.5 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply only capacitor of 3.15 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply only capacitor of 4.0 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply only PVC canopies of suitable size for ceiling fan of any make/model(set of two) with screws.
Supply only U clamps with rubber reel and nuts/bolts of suitable size with pins.
M & L for painting of ceiling fan with blades of any make/ model/ sweep of 1200/1400 mm required at any site of married and OTM Accn/E/M store by scrapping/scratching of old paints and apply with two coats of white enamel paint of approved quality and colour over a coat of primer including marking of MES No. all as specified and directed by the Engineer-in-charge.
All as per item No 82 above but for Exhaust fan of sweep 230/300/400/450-mm sweep.
Supply only rubber bush kit suitable for exhaust/wall mounting fan of any make/sweep complete.
Taking down existing louvers from any location or any height of bldg. with safety and re-fixed after repair with fastner complete all as specified and directed.
Supply only metallic / plastic louversof size 21" x 21" for 350mm/450mm/300mm sweep exhaust fan including fixing arrangment i.e. nuts , bolts, washers etc. complete all as specified and directed by Engr-in Charge.
Supply only Modular regulator electronic rotary step type suitable for ceiling fan of sweep 1200/1400 mm complete all as specified and directed.Make:- Kinjal/ Penta/Usha/Orient/bajaj
M & L for day to day maintenance and servicing for Split AC/Window AC for PCDA Jammu (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and water cooler, deep freezer, refrigerator and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition , all as specified and direted by Engineer In Charge. Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending day to day complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quated shall be inclusive of transport from AF Station to work shop & back shifting within permises. ( c) Any parts required to be replaced shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule.
Supply only the following Items to incorporate against repairable summer appliances Window / Split Type AC's against relevant items No. 88 here-in- before: -
Blower motor complete suitable for window/Split type AC upto 2.0 Ton.
Thermostat switch suitable for window/Split type AC up to 2 Ton. Make - Ranotroll, Denfess
Relay box suitable for window Type AC upto 2 Ton. Make- Voltas/ Bluestar/ LG/ As on site.
Power control Board ( PCB ) for window type / split Type AC up to 2 Ton.
Wiring kit suitable for Window/split AC and window Type AC upto 2 Ton.
Condenser fan motor complete with fan suitable for Window/split Type Air conditioner upto 2 Ton.
Relay suitable for Window/Split Type AC upto 2 Ton.
Foaming insulator for AC suction/ cooling line ( Approx - length 15').
Supply and fixing as in replacement ( hermetically ) uncut sealed compressor unit for Window/Split Type Air conditioner with filling of refrigerent gas for the following capacity: -
Capacity 1.0 TR.
Capacity 1.5 TR.
Capacity 2.0 TR.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Window/Split Type air Conditioners for the following capacity: -
Capacity 1.0/1.5/2.0 TR.
Repair to Power control Board (PCB) of Window/Split type AC upto 2.0 TR capacity.
Supply only the following capacitors to incorporate against repairable summer appliances Window / Split Type AC's , Desert cooler, Water cooler: -
Running capacitor 45 MFD. Make- Epcos.
Running capacitor 50 MFD. Make- Epcos.
Running capacitor 4 MFD. Make- Epcos , Havells.
Supply and fixing Plug top 15 Amps capacity, fixed in repairs complete all as specified and as directed.
Supply and fixing Plug top 5 Amps capacity fixed in repairs complete all as specified and as directed.
S&F Trigger Transformer (Control Step- down- transformer) 12-0-12 Volts for 03 KVA to 06 KVA.
S&F Power Relay 24 Volts / 250 Ohms 30 Amps ( 03- Nos) for 03 KVA to 06 KVA.
M&L Rewinding transformer of voltage stabalizer of capacity upto 05 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed.
S&F in repairs 240 Volt, sheet metal enclosure, distribution board single pole and neutral 2 way without bus bar.Make- Legrand/L&T/ABB
Disconnecting water and electric connections from existing position of geyser capacity 25/50 ltr, taking down geysers fixed to walls at any height, transporting to/ depositing in MES store yard for inspestion of Engineer-in-Charge to ascertain the serviceability / unserviceability and quantam of repairs involved including transportation of serviceable geyser capacity 25/ 50 Ltr from workshop to building site as directed for fixing in existing position making water and electric connections and testing complete as directed.
Repairs to geyser capacity 25/ 50 Ltr involving the following operations. (a).Dismantling (opening) of geyser complete in MES yard / workshop part by part of all the stationary parts, cleaning the covers and parts as applicable (b).Servicing, cleaning of geyser accessories and parts as applicable such as inner tank body, water inlet/ outlet assembely, heating element etc descaling with acid wash all as directed by Engineer-in-Charge. c). Assembling of geyser complete with old serviceable parts, replacement of unserviceable parts by new as ordered, renewal of nuts bolts and washers, rubber gasket complete as directed by Engineer-in-Charge. Note:- (i) Parts required to be replaced shall be measured and paid separately as "supply only " against relavant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item. (ii) Any minor parts / repairs involved to make the geyser completely functional even if not notified by Engineer-in-Charge shall be carried out by the contractor without any extra cost to the Department.
Shifting of Geyser of capacity upto 50 Ltrs including submain/point wiring all electrical items and drilling , making good on surface of PCC concreting, white cement plastering and iron frame /angle all necessary items and transporting complete from one location to other location in 23 Wing area and 256 SU Kaluchak and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge.
Supply only heating element with rubber washer ('O' ring) cap 1.5 KW. (triangular / round ) any type. Make- Make- Theetta, Micron., DasPass , Bajaj
Supply only heating element with rubber washer ('O' ring) cap 2 KW (trangular/ round ) Type Make- Theetta, Micron., DasPass , Bajaj
Supply only indicator bulb neon round / square type single phase 230 Volt
Supply only Safety plug 15mm ( brass ) for geyser cap 25/50 Ltr.
Supply only Thermostat 30 deg.C to 70 deg.C 230 Volts.
Supply only Inner tank for geyser cap 25/50 ltr of MS Steel sheeting thickness of gauge 20 (Geyser make :- Bajaj, usha, recold, venus, vguard)
Supply only geyser water (inlet/outlet) assembly brass for geyser cap 25 Ltr of any type.(Geyser make :- Super hot, Racold, Bathwell, Ditz, Kumar, Pearl, Classic, Pieco)
Supply and fixing Indus series Powder coated pressure die cast alluminium compact high power LED street light fittings with heat resistant toughned glass with lense having 45 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make: Bajaj/Havells/ Crompton
Supply only PVC connection 600 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water complete all as specified and directed. Make: Theetta / Micron / DasPass / Bajaj
Supply only Glass wool of approved quality as recommended by the approved manufacturer's of geysers complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Scraping old paint of 25 litres capacity geyser (Approx painting area- 1.5 Sqm) making the surface smooth for painting, applying two coats of synthetic enameal paint over a coat of red oxide primer, with superior quality approved paint as approved by Engineer-in-Charge
Supply and Fixing in repair Globe light fitting 15/27 watt flame proof , certified recommended for gas /vapour group of IIA & IIIB , zone 1 & 2 and IP 54 protection with die cast aluminium housing, Gardening with heat resistant toughened glass with LED bulb light fixtures driver, holders, connector etc. complete with all accesories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Make : Philips/ Havells/ Crompton
Supply and Fixing in repair Outdoor Garden lights Lights offers a wide range of Bollard Lights, Garden lights and path LED lights warm white,size 24 to 30" (Inch) , body color, black Make : Crompton /Philips/ Havells etc.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S Chib Engineers
Harsh Electricals
M/s Sahib Construction and engineers
Rakesh Kumar Malia
NATIONAL TRADING COMPANY
M/s Raj Construction
M/s Shakti Electric Works
M/S ESS ESS ENTERPRISES
bamral builder
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .