| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 5 2 414 DACHA MANSION FLAT NO 3 VILLAGE TOWN HYDERBASTHI CITY SECUNDERABAD HYDERABAD TELANGANA 500003 INDIA | HYDERABAD | TELANGANA | 500003 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.1 L
EMD Value
₹8,130
Closing Date
24 Feb 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E) BSNL ED Warangal
2nd floor KTB TE Building Hanmakonda Warangal
Shifting and ITC of 160 KVA substation at Nizamabad
2023_BSNL_145405_1
NIT39/EE/BED/WGL/2022-23
Open Tender
Electrical Works
Item Rate
60 days
Nizamabad
Please refer Tender documents.
16 documents required · 16 mandatory
₹590
AO cash BSNL Nizamabad
₹8,130
25 Feb 2023
14 Feb 2023
25 Feb 2023
14 Feb 2023
24 Feb 2023
14 Feb 2023
Amount
Attending HG fuse Burntout Problem, openining of all covers, Meggaring and checking of HT Panel, HT cable and Transformer with 5000 volts Insulation Tester in 2 x 250 kva I/D type substation, including finding and aresting the problem in HT Panel Bus Chamber and HT Spots of OCB and restoring the supply to normal as required
Bypassing of HT incoming supply from faulty OCB to TR-3 by disconnection of Termination from HT Panel removing of 95 sqmm HT cable from trench relaying upto TR-3 [approx 15 Mtr] by cutting of 6mm thick bottom plates at OCB and Transformer, reconnection in Tr-3 by removing of existing OCB-3 cable as required
Checking of Winding Resistance of 250 KVA Transformer with backfeeding test with DG supply to MV panel, transformer , HT cable upto CT/PT including providing temporery cables, fuses etc., to found HT equipments are healthy to restoration of HT supply including providing of new HG fuses, cheking of all building loads after restoration of TRANSCO supply as required
Checking of Capacitor panel and APFC relay identification of CT sencing cable, removing from HT panel and relaying from MV panel Incoming ACB [approx 20 Mtr] including wiring and programming of realy as required
Supply and applying of Monoplast sealings to HT termination
SITC of RS Joist size of 150 x 75 x 9000mm Length, including welding of base plate size of 300 x 300 x 12 mm thick checked plate, including welding transportation , 2 coats of red oxide paint, transport to site etc., as required.
providint cement cocrete bed of size concrete 1800 mm depth 600 mm L x 600 mm W,providing 60mm metal bed, pole lifting, filling of 40mm metal concrete, 450mm x 450mm pole coaping,including lifting the pole by arranging crane /labour plastering making good etc as required
Supply and fixing MS Chanel size of 100 x 50 including cutting, drilling, welding of clamps, 2 coats of red oxide paint, fixing on new pole and existing DP, providing nutbolts MS clamps , transport to site etc., as required.
Supplying and fixing of following accessories suitable for operation on 11 KV, three phase, 50Hz, AC supply and fixing in same in the new DP structure including providing nutbolts MS clamps etc., as required. a) AB switch
b) HG Fuse set
c) Pin Insulators
d) 70 sqmm Allu.OH conductor with PVC colour sleev covering
Painting the 3 Pole and MS structure with aluminium paint, cleaning the rust with emry paper making good etc. the items which shall be covered in this work are 3No MS poles, horizontal 'C' channels, other connected items related to the out door yard.
SITC of GI Pipe Earth pit with 2500mm deep excavation, 75 mm CI Pipe With 150 mm Flange, closing with charcoal of 90 kgs.,. 20 kgs., salt, providing SS Nut bolts for connections, required civil work etc as reqrd.,
Supply and fixing of '8' SWG GI wire for HT equipment Earthing etc.,
Supplying of 3 core 11kV grade 95Sqmm XLPE aluminium conductor cable with ISI mark from New box pole to CT/PT including transort to site, interconnections etc. [Make : Polycab /ss]
Supplying and making out door/Indoor type End termination with Heat Shrinkable joint kit to the existing 3 core 95 Sq. mm X L P E, 11KV H.T. cable including crimping of lugs, providing cable supporting clamps, testing etc as required. (Raychem or SS make)
Checking, Meggaring of 160 KVA Transformer, shifting to out side of store yard Truck Loading area by using of crane/ traypad including removing other matrials on moving way as reqd., [DE office Bhongir]
Shifting of 160 Kva Transformer Bhongir to TE Nizamabad including Loading and Unloading by using of Crane/Traipad and Transport charges
Disconnection of 250 KVA Transformer HT Terminations, LT cable, earth and neutral strips, removing from location to fix new Transformer by using of Labour as reqd.,
ITC of 160 KVA Transformer by shifting to in side of building S S Room by using of manpower including connectin of HT Cable, LT cables, earth and neutral strips, as reqd.,
Filtration of Transformer oil for 250/160 KVA Indoor transformer at site, such as removal of all suspended particals like dust, rust, scales,colloidal carbon oxidation sludge etc., Degassing and Dehumidification of transformer oil under vaccum. Circulation of heated oil and filling of treated oil in transformer tank. De-acidification by evaporation and absorption meathod and including transportation of of filtering machine, providing test cetificate etc., as required.
Top up of transformer oil in the conservator tank up to the minimum level after filtration of the transformer oil as req.,
Supplying and fixing of silica gel breather including removing the old breather etc., as required.
General servicing of MV panel, Power room panel, capacitor panel by checking for any loose wires, contacts, tightening the link bolts, checking of overheating of any wires, links rectifying the defects if any, cleaning the complete panel with blower to remove the dust etc., as required.
General servicing of existing 800A capacity ACB in the MV panel, cleaning of contacts with CTC(carbon tetra chloride chemical), checking of trip bridges, shunt trip, UV coil, applying oil and grease for moving contacts checking of interconnections from the IDMT relay to ACB and other minor connected works
Supplying and fixing of LED indication lamps
P.S.ENGINEERS
stage.html
html • 0.02 MB
finance_158998.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .