| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹18.4 L+₹98,854 (5.68%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest bidder | |
| 3 | L3₹18.7 L+₹1.3 L (7.50%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L3 | Rejected-Finance Not being Lowest bidder | |
| 4 | L4₹19.8 L+₹2.4 L (13.9%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest bidder | |
| 5 | L5₹23.6 L+₹6.2 L (35.4%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L5 | Rejected-Finance Not being Lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Jan 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT OF MCCBS, CHANGE OVER SWITCH AMF PANELS AT VARIOUS DG SETS, INSTALLATIONS OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW.
2019_MES_300344_1
GE/EM/EXT(ELECT)/58 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class E or above, category b (i).
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹50,000
Yes
7 Feb 2020
22 Nov 2019
16 Jan 2020
22 Nov 2019
15 Jan 2020
23 Dec 2019
Amount
Supply, installation, testing and commissioning out door type LT Feeder Piller/LT panel made out of 3.15 mm thick MS sheet duly powder coated and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform , frame factory fabricated with front and back openable double door system lockable/openable by Keys completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity comprising of the following :- a) The TPN busbar duly plated Aluminium busbar fitted in cascaded moulding of suitable capacity. b) Incoming MCCB 250 Amps 36 kA, 415 volts, FP fixed thermal magnetic- 01 No c) Outgoing MCCB 100 Amps 25 kA, 415 volts, FP fixed thermal magnetic - 04 No d) Outgoing MCCB 63 Amps 25 kA, 415 volts, FP fixed thermal magnetic- 01 No e) Change over switch 200 Amp on load type, 415 volts, FP - 01 No f) Provn of blank compartment for future uses, 415 volts, FP - 01 No g) Voltage/Ampere/Frequency meter - 01 No h) LED indicator lamp RYB - 01 Set of three
Supply & fix Decorative wall mounting tube light fiting light 36 Watt LED with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size.
Supply and Fixing security lights LED 45 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 66 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniformlight spread cames LED technology of Britelite. The Lights are equipped with state of the art scrche and lock design, dimensional heat management LED system of Size 45 watt including bracket made out of suitable size of GI medium grade tubing 2 metre long and bent to shape at 120 degree angle at the middle from vertical, fixed with clamps nuts and bolts, washer complete all as specified .
Repairing to Dynamo/alternator assembly of 12 Volts/24 Volts from the DG sets replacing the spare parts such as carbon brushes, springs, spring holders, brushes, bearings or any other part required for full functioning, etc and fixing the same complete all as specified and directed by Engineer-in-Charge
Rewinding of armature of Dynamo/alternators dismantling the old coil, cleaning thoroughly and wound with new super enameled copper cord of existing size and gauge, varnishing, drying etc, and fixed with dynamo/alternator properly testing and commissioning all as specified and directed by Engineer-in-Charge
Supply and fixing of oil pressure gauge of existing size and model for any make/model/capacity of DG sets complete.
Supply and fixing in repair AVR unit /CVR –II for 320/250/200 DG Set. Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit /CVR –II for 125KVA/110KVA/100KVA DG Set. Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit /CVR –II for 82.5KVA/63KVA/62.5KVA DG Set. Make : Kirloskar/Cummins
Supply only battery terminals made of brass superior quality.
S & F in repair PVC heavy duty pipe of size 10 mm dia for Diesel tank indicator with suitable clamps.
S & F in repair controller for electronic control panel for DG Set upto 125 kva completet all as directed
M&L for cleaning and day to day maintenance of DG Set installation by using cotton waste -10 kg, yellow cloth 1x1 meter size-05 nos, two rin soap of 300 gm and two broom stick -04 for cleaning DG Set installation all as directed .
M&L for repair of DG set canopy by replacing of door hinges and locking arrangement complete all as directed
Supply only PVC pipe of size 25 mm dia heavy duty for fol distibution complete all as directed
Supply only EMPTY BARREL heavy duty made of steel of 220 ltr capacity for collection of a FOL complete all as directed
Supply and spread river sand including removing of old diesel wetted sand from FOL store complete all as directed by engr in charge.
M&L For for replacing of fly wheel teeth ring of capacity up to 125 KVA DG Set including taking down old unserviceable including repair of self by replacing of penion of self startor of DG Set complete all as directed.
M&L for cleaning by desludging of fuel tank of DG Set by including out going and over flowing pipe and replacement of fuel indicator pipe including make locking arrangement of tank ,painting of tank complete all as directed by Engg -in- charge.
Supply and fixing rotating rectifier assembly for 320/250/200 KVA DG set of any make and model.
Supply and fixing rotating rectifier assembly upto 125/110/100 KVA DG set of any make and model.
Supply and fixing rotating rectifier assembly upto 82.5/63/62.5 KVA DG set of any make and model.
Supply and fixing in repairs rectifier diode for 250/200 KVA DG sets.
Supply and fixing in repairs rectifier diode for 125/110/100 KVA DG sets.
Supply and fixing in repairs rectifier diode for DG sets upto 82.5 KVA capacity.
Supply and fixing in repairs voltmeter square/ round upto 500 Volts of existing size. Make : MECO/AE all as directed
Supply and fixing ammeter 0-300A.
Supply and fixing indicator lamp assembly 230/110 Volts as per existing size
S & F battery leads 95 Sqmm copper cable 1.5 Mtr long with brass terminals of suitable size cable
Supply only coolant concentrate Pert No SK 802 OIC Make : Valvoline and equivalent
Supply and fix in repairs electronic control timer type ET-100 of suitable capacity as required at site. (Make:- L&T or equivalent as approved by GE)
Supply and fix in repairs engine starter relay of suitable capacity as required at site. (Make:- L&T or equivalent as approved by GE)
Supply and fix in repairs under voltage relay (Make:- PIC / EC / Wader.)
Supply and fix in repairs 8/11 pin relay (Make:- PLA.)
Supply and fix in repairs Auto Mains Failure (AMF) relay as per existing model and make of AMF panels of DG sets of any capacity.
Material and labour for recharging of old used battery 12 Volts, 180 AH rating including cleaning complete and filling with acids as required all as directed.
Material and labour for recharging of old used battery 12 Volts, 150 AH rating including cleaning complete and filling with acids as required all as directed.
Material and labour for recharging of old used battery 12 Volts, 88 AH rating including cleaning complete and filling with acids as required all as directed.
Supply and fixing crocodile clip for battery chargers of required size all as specified and directed.
Supplying, fixing, connecting & testing battery, 12 volts, 180 AH with lead acid terminals,indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified (Model No. FXPO-MHD1800 Exide New express or equivalent of other specified make) including disconnecting existing unserviceable battery.
Supplying, fixing, connecting & testing battery, 12 volts, 150 AH with lead acid terminals,indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified (Model No. FXPO-MHD1500 Exide New express or equivalent of other specified make) including disconnecting existing unserviceable battery.
Supplying, fixing, connecting & testing battery, 12 volts, 110 AH with lead acid terminals,indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified. (Make- EXIDE / AMRON ) including disconnecting existing unserviceable battery.
Supplying and fixing in replacement, testing off load changeover switch 63 Amps TPN with sheet metal enclosure ,side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing of following capacities:- Make - L&T/Schneider/C&S/indoasian/HPL
All as per Item No 44 above but 100 Amps
All as per Item No 44 above but 200 Amps
All as per Item No 44 above but 315 Amps
Supply & Fixing in repairs "ON LOAD" type Change over switch 630 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply of following ratings :- Make - L&T/Schneider/C&S/indoasian/HPL
All as per Item No 48 above but 400 Amps
All as per Item No 48 above but 315 Amps
All as per Item No 48 above but 250 Amps
All as per Item No 48 above but 200 Amps
Supply only distilled water for batteries.
Supply and fix in repairs new battery charger heavy duty type with voltmeter and ammeter, with copper wound transformer, suitable for charging 12 Volts 180 AH battery complete all as specified and directed.
Supply and fix in repairs battery charger heavy duty type with voltmeter and ammeter, with copper wound transformer, suitable for charging 02 Nos 12/ 24 Volts 180 AH battery complete all as specified and directed.
Supply and fix in repairs power contactor 4NO assembly of capacity 150 AMPS, 3 /4 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one complete all as specified and directed.
Supply and fix in repairs power contactor 4NO assembly of capacity 200 AMPS, 3 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one complete all as specified and directed.
Supply and fix in repairs power contactor 4NO assembly of capacity 400 AMPS, 3 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with Aluminium Conductor, 1100Volts grade including cable lugs, nuts, bolts and washers of suitable size in cable ducts/trenches and taking out the old one of 300 Sqmm 3.5 Core size :-
All as per Item No 59 above but 240 Sqmm 3.5 Core
All as per Item No 59 above but 95 Sqmm 3.5 Core
All as per Item No 59 above but 70 Sqmm 3.5 Core
S & F MCCB in repairs MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make :HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : :HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make :HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : :HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : HAVELLS/L&T/C&S/INDOASIAN/HPL
S & F MCCB in repairs MCCB 3 Pole of capacity 400 Amps, 50 Hz, 415V with rupturing capacity of 50 KA with fixed thermal magnetic settings including spreader terminals complete all as specified and directed. Make : :HAVELLS/L&T/C&S/INDOASIAN/HPL
Supplying and fixing in repairs Cable jointing kit for 1100 Volts grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of 240 to 300 Sqmm 3.5 Core size :-
All as per Item No 71 above but 120 to 185 Sqmm 3.5 Core
All as per Item No 71 above but 50 to 95 Sqmm 3.5 Core
All as per Item No 71 above but 10 to 35 Sqmm 3.5 or 4 Core.
M&L for in repair of DG set fuel UPVC pipe 15 mm bore by replacing including elbow, tee , socket etc complete all as directed
Supply, fixing and testing in repairs Self Starter 24 Volt, DC for DG Set of capacity upto 320 KVA (Make of DG Set Kirloskar/Cummins) complete all as specified and directed.
Material and labour for hiring of fault locator for locating faults in UG XLPE cables complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface & sides to required slope/size as directed by the Engineer-in-Charge
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by the Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed by Engineer-in-Charge.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Supplying & Laying Sub Class 'B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engineer-in-Charge.
M & L 60 mm thick PCC interlocking tiles, rubber moulded and chemically coated, using grey cement and pigment of size and shape as approved, including 100 mm thick bed with PCC 1:2:4 type B1 with 20mm graded aggregate and layer of dry sand not less than 40 mm thick, interstices filled in floors/ pathway incuding locking the the tiles on all four sides with PCC complete all as specified and directed by Engr-in-Charge. (PCC & Sand cushion shall not be measured and paid separately).
Ajanta Associates
M/s Vatsh Raj and co
Shree Tirupati Associates
Unnati Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .