| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.5 L+₹59,435.40 (2.49%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹29.5 L+₹5.6 L (23.4%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹29.5 L+₹5.6 L (23.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹39.1 L+₹15.2 L (63.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Nov 2021, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Provn of E/M works and E/M appliances and certain sanctioned works at AF Stn Jaisalmer
2021_MES_482287_1
8786/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹60,000
Yes
22 Nov 2021
16 Oct 2021
12 Nov 2021
16 Oct 2021
10 Nov 2021
28 Oct 2021
18 Oct 2021 - 23 Oct 2021
Amount
Supply, installation, connecting and testing, electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW, capacity 25 litre, BEE 5 star rated complete with all assessories such as 02 Nos hot water gun metal glove/safety valve 15mm bore, 02 Nos hot water PVC connection 450mm length and 01 Nos hot water tape of brass/gun metal 15mm bore etc omplete all as specified and directed.
Gun metal globe valve/safety valve 15mm bore, fancy type, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule and fixed for hot water supply complete all as specified and directed.
Bib tap of brass/gun metal 15mm bore, fancy type, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule and fixed for hot water supply complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
PVC connection 450mm length for geysers, suitable for 15mm bore including necessary clamps, nuts and bolts complete all as specified and directed.
Sub main wiring with 4.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in PVC conduit 25mm dia complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor alongwith stove enamelled steel conduit shall be measured & paid as one unit.
Single Pole and earth enclosure with two pin and earth plug and MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, with one Single Pole, 20 Amps, repturing capacity 10 kA including taking down old unserviceable complete all as specified and directed.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles fixed complete all as specified and directed.
MCB, SPN, 40 to 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, fixed as in repair complete, all as specified & directed.
Exhaust Fan, steel body, 300mm sweep, heavy duty, ISI Marked with mounted in suitable opening arrangement with louvers shutters suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to exhaust fan including marking of MES number and making holes into wall and fixed to wall by using 4 Nos, bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed.
Point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and stove enamelled steel conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and stove enamelled conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified & directed.
Point wiring for one 3 pin, 16 Amps socket outlet controlled by one 16 Amps switch on independent board with 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and stove enamelled steel conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and stove enamelled conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified and directed.
Sheet metal enclosure powder coated Single Phase and neutral, Factory made, Prewired flameproof distribution board (DB) SPN 8 (2+6 ways) and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (class IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
Flameproof Fluorescent luminaire, Tube light fitting, 1x16 watt including LED tube, flame Proof, CMRI certified recommended for gas vapor group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holder, connector block, etc and all accessorie pre-wired and incuding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 16 Amp, single pole, 250 Volt complete all as specified and directed.
Flame proof switch socket plug combined in LM6, cable termination box in LM6, 16 Amp, 2 Pole with neutral, 250 Volt complete all as specified and directed.
Supply, installation, testing and commissioning of conventional optical smoke detectors with an optical measurement method for earliest fire detection and indication and type certified complete with standard base for conventional detector complete all as specified and directed.
Supply, installation, testing and commissioning of zonal indicator panel of upto 2 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, installation and connecting conventional type manual call point resettable, typically installed at various fire escape route locations throughout a premises complete all as specified and directed.
Supply, installation, connecting and testing conventional wall sounder complete all as specified and directed.
Remote response indicators complete all as specified and directed.
Sub main wiring, Single core, 2x1.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x1.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in surface/recessed steel/PVC/steel rigid conduit complete all as specified and directed.
Sub main wiring, single core, 2x2.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x2.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in surface/recessed steel/PVC/steel rigid conduit complete all as specified and directed.
Supply, installation, connecting and testing of Automatic chlorine dozing system with following arrangement complete all as specified and directed:- Make : Declibac Model No. ADS-Duo Aqua/Aventura or equivalent. (a) Water Inlet Valve (b) Overflow valve (Rubber guard included) (c) Outlet Valve for standalone gravity flow (d) Outlet valve with automated flow (e) Drain valve (f) Level controller (g) Level gauge (h) Capacity - 200 Litre (j) Shape - Cylinderical
Supply, installation, & testing, split type, Air conditioning unit (indoor & outdoor), electric driven single phase of capacity 1.5 TR (BEE 5 star rated) complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions complete all as specified & directed. Note:- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing indoor & outdoor unit & other minor extras shall be deemed included in quoted rate of this item.
Supply, installation, voltage stabilizer for automatic operation single phase naturally air cooled indoor type copper wound and designed for input variation between 140 volts to 280 volts with output voltage stabilized at 200-240 volts with accuracy of ± 2.5% of capacity 5 KVA wall mounted with time delay relay complete all as specified and directed.
M/s Ramesh & Company
M/s Shree Construction Company
Manisha Enterprises
SS SODHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .