Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.6 LAccepted-AOC SHIVPURI COLONY CHAS BOKARO | BOKARO | JHARKHAND | 825102 | ₹93.6 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹94.2 LRejected-AOC | ₹94.2 L | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹94.2 LRejected-AOC BHAGWATI COLONY JODHADIH MORE CHAS BOKARO | BOKARO | JHARKHAND | 825102 | ₹94.2 L | L3 | Rejected-AOC L3 bidder |
| 4 | Rejected-Technical FLAT NO 302 BLOCK C NILKANTH APARTMENT CHAS BOKARO | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of ITB F2 Contract Sl. No. 9 (B)(1)(vii) of F2 bid document |
Updated dates
Tender Value
₹94.2 L
EMD Value
₹1.9 L
Closing Date
21 Oct 2025, 5:00 pmClosed
Chief Engineer
Jharkhand Police Housing Corporation Limited Line Tank Road Ranchi 834001
Construction of M.T. Shed at Home Guard, Bokaro in the district of Bokaro.
2025_JPHCL_105141_1
JPHCL/GR 13/NIT 04/2025-26
Open Tender
Civil Works - Buildings
240 days
Bokaro
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.9 L
Yes
22 May 2026
26 Sept 2025
24 Oct 2025
26 Sept 2025
21 Oct 2025
26 Sept 2025
5.1.1 EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.1.7 EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.4 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.2 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
5.3.10 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
5.3.11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
5.3.17.1 Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete
5.3.17.6 Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts
5.3.17.19 Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.2.3 Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
5.3.5 Providing 25 mm thick DAMP PROOF COURSE with cement concrete M-20 with nominal mix 1:1.5:3 with approved quality of stone ships of 20 mm to 6 mm (20mm to 10 mm : 10 mm to 6 mm stone chips 2:1) size graded and clean coarse sand of F.M. 2.5 to 3 including screening, mixing cement concrete in mixer with 5% Cico or any other approved water proofing compound and placing in position, striking, curing taxes and royalty and complete as per building specification and direction of E/I.
5.2.11 Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
5.2.50 Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:3) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
5.7.3 Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
5.7.6 Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
5.7.3 Providing 12 mm thick CEMENT PLASTER (1:6) on outside wall with clean coarse sand of F.M.1.5 and 5% cico including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. 8 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.5.5 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. 12 mm, 16 mm & 20 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
13.21/D.S.R. Extra for providing and mixing waterproofing material in cement plaster work in proportion recommended by the manufacturers.
5.3.8 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
5.7.21 Making 20x6 mm grooves in plaster surface over walls trully horizontal or vertical as specified at regular intervals at all heights including cleaning finishing , scaffolding and curing with all leads and lifts of water all complete as per buildinng specification and direction of E/I.
16.91/DSR Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
5.6.10 Providing 12mm cement plaster (1:3) with clean coarse sand of f.m. 1.5 with flooring coat of neat cement in skirting including rounded of junction with floor , curing ,
DSR 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) WT. OF AL. SECTION FOR 3 TRACK WINDOW - @ 0.75 KG PER S.FT.
5.5.12 Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
5.8.6 Colour washing two coat over a coat of white wash over new surface thoroughly and removing the scales of smoke and mash marks with jhama rubbing scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.
DSR 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives "Snowcryl - XT" of M/S Snowcem India Ltd, or equivalent of required shade. New work (Two or more coats applied @1.43 ltr / 10sqm. Over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg./10 sq.m. )
DSR 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
5.8.42 Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
5.8.45 Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
DSR 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work
Stone Chips (20 KM.)
Cement (5km)
DSR 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
METRE
METER
Fly Ash Brick (1K+19P=20 km)
Coarse Sand (18 KM.)
5.10.33 Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:8) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
17.28.2.1 Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
12.41.2 110 mm dia
DSR 12.42 Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
18.8.1 15mm dia
18.7.3 25mm dia
19.6.2 150 MM dia R.C.C. pipe
3.3.8 Supllying and matarials with lobour for construction inspection chamber of designation class 75 B brick 750mm deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6) including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm C.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Septic Tank and Soakpit
5.1.1 Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
5.1.10 Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
5.6.1 Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.2.23 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out
5.7.1 Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
5.7.1 Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.3.17.21 Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.5.5a 10mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
Steel (5km)
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
METER
Fly Ash Brick (1K+19P=20 km)
Brick (1k+19p=20km)
Coarse Sand (18 KM.)
JSR Page no (59) SI no(16) Item code (M-198) (Basic rate +14.95%) Brick bsts at Kiln site
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
From 0.0M to 50.0 M belew G.L
200x150xmm dia Deep bore Well With Pump set & electrification etc works.
DW & SD Page no(57) SI no.119 M 1035 (basic rate+14.95%) Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.
From 51.0 M to200.00 M belew G.L
DW& SD page no(58) SI no. 120 (M 1036) (basic rate+14.95%) supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc all complete job.
DW& SD page no(65) SI no. 126 (M1042) (basic rate+14.95%) Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction E/l (Basic Rate).
DW& SD page no(58) item no. 120 (M 1036) (basic rate+14.95%) Supplying all materials, labours, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job (Basic rates)
DW & SD Page no(67) SI no. (139)(M1055) (basic rate+14.95%) Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
PM 1-2-2 Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP
Rate Analiysed and Approved 2no heavy duty clamp 40mm dia duitable for pipe with all complet job.
DW & SD Page no(78) SI no. 149 M 1065 (basic rate+14.95%) Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914. F.A.S.D. Starter 10HP
Energy department Sor Page no.36 M-1627 (basic rate+14.95%) Supplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed as per IS : 7098 3 Core 4mm thick
DW & SD Page no 35 SI no14, M 9
30 (K-(v) Supplying & lowering 40mm da column G. I. pipe with all complete job.
INTERNAL & EXTERNAL ELCTRIFICATION WORK
Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Finolex (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/ Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)/Legrand/Schneider (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/Legrand/Schneider (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard (7) LED ITTING FIXTURE -: Havells/Bajaj/ Crompton (Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED
1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1.7.2 2x2.5 sq mm+1x2.5 sq mm earth wire
1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
1.3.2 Group B
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1.24.1 5/6 amps, one way switch
1.24.4 5/6 amps, 3 pin socket outlet
1.4 Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
1.7.5 2x10 sq mm+1x6 sq mm earth wire
1.7.12 4x16 sq mm+2x6 sq mm earth wire
1.32 S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
1.33 S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1.25 S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
1.27 S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1.48 ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
1.27.3 6 module(78mm x 205mm x 50mm)
1.35 Errection on incandescent light fitting:- Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
1.36 S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
2.1 S/F rewireble double pole/TP&N switch disconector:- Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required.
2.1.2 32 amps double pole
2.1.4 32 amps, TP&N
2.4 S/F MCCB in cubical panel board:- Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panel making connections etc as required.
2.8 S/F S.P. MCB DB:- Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
2.4.3 125 amps, 16 KA fixed thermal seting
2.10 S/F VERTICAL TYPE T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) Note:- Vertical type MCB TPDB is normally used where three phase outlets are required.
2.7 S/F, panel mounting changeover Providing and fixing following capiacity 4 pole panel mounting chengeover switches in existing cubical panel board,making connection, earthing the body etc as required.
2.11 S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.11.1 6/32 amps,single pole, "B" SERIES
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.7.4 125 amps, 4 pole
2.8.8 8 Way,Double door
2.10.4 8 way (4+24),Double door, Vertical type
2.12.3 6/32 amps,SPN
2.13 S/F SP MCB blanking plate:- Supplying and fixing Single pole blanking plate in exiting MCB DB complete etc as required.
2.12.4 40 amps ,DP
2.12.7 50/63 amps, DP
3.6 Copper Earth plate electrode:- Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
3.7 S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
5.1 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
5.2 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
2.12.9 40 amps,TPN
2.18 S/F 20 amps SPN MCB industrial socket outlet:- Supplying and fixing 20 amps, 240 volts,SPN industrial type, socket outlet, with 2 pole and and earth, metal enclosed plug top along with 20 amps 'c' series, SP MCCB, insheet steel enclosure,in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
2.19 P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1)
M-738 16 sq.mm. 2 core
M-740 16 sq.mm. 4 core
M-329 70 sq.mm. 3.5 core
DSR 12.37 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
DSR 9.1. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
DSR 9.1.3 2 X 16 sq. mm (22mm)
DSR 9.1.33 4 X 16 sq. mm (28mm)
9.4 S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
DSR 9.1.23 3½ X 70 sq. mm (38mm)
9.3 SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
7.1 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
M-775 Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton
9.4.1 1200 mm (48") Ceiling Fan of make bajaj/havells/usha/crompton/polar
9.3.3 15/16 W LED Round Down Light of make bajaj/havells/crompton/C&S
9.1.7 90 /100 W LED Street light of make bajaj/havells/crompton/C&S
9.5 SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
9.2 S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wall for supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton/C&S
9.2.5 120 W LED FLOOD LIGHT of make bajaj/havells/crompton/C&S
M-869 Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
9.5.1 10/12 W LED Batten of make bajaj/havells/crompton/C&S
9.5.2 20/22 W LED Batten of make bajaj/havells/crompton/C&S
Add 18% GST
Add 1% Lebour Cess
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_141492.xls
BOQ • 0.43 MB
Techbid13.pdf
Tender Documents • 7.05 MB
Download all tender documents and submit your bid