Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹45.0 L+₹8.1 L (21.8%)Rejected-Finance 42 INDUSTRIAL ESTATE GWALIOR MP 474004 | GWALIOR | GWALIOR | MP | 474004 | L2 | Rejected-Finance Not a lowest tender |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA Gwalior
GE AF TA Gwalior 474020
REPAIRS/MAINT OF SPLIT/WINDOW ACs, SUMMER COOLING AND CONNECTED WORKS IN CERTAIN BLDGS IN EAST WING IN TECH AREA AT AF STATION GWALIOR
2023_MES_595417_1
8900/1497/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF TA Gwalior
₹98,000
Yes
14 Jul 2023
15 May 2023
22 Jun 2023
15 May 2023
15 Jun 2023
2 Jun 2023
Amount
Preventive maintenance & routine servicing of split AC of any type/size/make /model & capacity up to 3TR in any position/ work shop as convenent indoor & out door unit by cleaning of dust from condenser,airfilter, coolingcoils, by pressure pump of liquid line filter/capillary tube /expansion valve, refrigerent inlet /out let pipe by Nitrogen and Etheline tri chloride(ETC),and checking of all electrical components and compressor etc. Replacement of minor part such as nut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed. Note:- (i) The replacement of minor defective / nonfunctional parts during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ from item 3.01 to 3.22 and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging of gas, if required, shall be issued by Dept, under Schedule 'B' free for usage measured and paid for separately under appropriate item of Schedule `A'. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.
Preventive maintenance & routine servicing of Window type AC of any type/size/make /model & capacity at any position including cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers incl replacment of unserviceable parts of capacity 1.5/2.0 TR of single phase etc and testing complete all as specified and directed. NOTE :- (i) The replacement of minor defective / nonfunctional parts during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ from item 3.01 to 3.22 and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging of gas, if required, shall be issued by Dept, under Schedule 'B' free for usage measured and paid for separately under appropriate item of Schedule `A'. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.
Supply only following items of Air conditioning split/window type AC of capacity 1.5/2/3TR of any make/model/ capacity.including checking of defects and rectified. (a) Supply only Starting capacitor 80 mfd suitable for 240 Volts 50 HZ AC supply.
(b) Supply only Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply
(c ) Supply only Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ AC supply
(d) Supply only Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply
(e) Supply only Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply
(f) Supply only PVC braded drain pipe of size 15 mm inner dia
(g) Supply only PVC braded drain pipe of size 20 mm inner dia
(h) Supply only PVC braded drain pipe of size 30 mm inner dia
(j) Supply only Over load Relay confirming to Model 85001-2/3/4/5 Make :Annapurna
(k) Supply only Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of any capacity, model and make all as directed.
(l) Supply only Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 1.5 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1842
(m) Supply only Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 2.0 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1846
(n) Supply only Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR (2x1.5) of any capacity, model and make
(o) Supply only Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
(p) Supply only Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
(q) Supply only PVC Grills as per exisitng make of window AC Make :- LG/Carrier/Blue star/Feederllord
(r) Supply only Capacitor 2/4/6 mfd 230 volts for blower motor of window AC/split type AC
(s) Supply only Thermostate switch with knob 230 volts for Window AC
(t) Supply only PVC fan blower assembly for 1.5 /2TR window / split AC's any make
(u) Supply only Wiring kit consisting of 2.5 Sqmm copper PVC insulated stranded copper wire with copper lugs , thimbles and solder connection complete suitable for window type AC's of any make or model
(v) Supply only Condenser side fan blade suitable for existing Window type AC's of make :samsung / Videocon /Carrier /Voltas/LG
(w) Supply only Check valve 3/8" dia for upto 2.0 TR capacity Split AC's Make :- Danfoss or equivalent make as approved
(x) Supply and fixing in repair/replacement Blower motor 1330 RPM, 32W, Single phase suitable for 230 volts of 1.5 TR split AC Make : Guangdong welling Motor Model No. RP35 B-3 or equivalent as approved.
(y) Supply and fixing in repair/replacementBlower motor three speed 1/7HP to 1/5 HP 900 RPM suitable for 230 volts of 3.0 TR split AC Make : Speed King or equivalent as approved.
(z) Supply and fixing in repair/replacement copper tubing of special annealed pressure copper of size 3/8" bore
(aa) Supply and fixing in repair/replacement copper tubing of special annealed pressure copper of size 5/8" bore
(ab) Supply and fixing in repair/replacement copper tubing of special annealed pressure copper of size 1/4" bore
(ac) Supply and fixing in repair/replacement copper tubing of special annealed pressure copper of size 1/2" bore
(ad) Supply and fixing in repair/replacement Harmetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts, Make : Techamsha model No. 5522E
(ae) Supply and fixing in repair/replacement Hermetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts, Make : Emersion CR22 MK-6
(af) Supply and fixing in repair/replacement Hermetic sealed Reciprocating compressor suitable for 2.0 TR 230 volts Make :- Emersion model No. CR-30
(ag) Supply and fixing in repair/replacement Hermetic sealed Reciprocating compressor suitable for 3.0 TR 415 volts Make :- Emersion model No. CR-42
(ah) Supply and fixing in repair/replacement Rotary compressor suitable for 1.5 TR 230 volts 50 HZ Make :- Techamsha model No. PH 290
(aj) Supply and fixing in repair/replacement Rotary compressor suitable for 2.0 TR Make :- Techamsha model No. PH 380 or equivalent as approved
(ak) Supply and fixing in repair/replacement Electric fan motor 1/8 HP 900 RPM suitable for 3 TR split AC out door unit, three phase Make :- LG/Blue star/ Voltas or as per existing make of AC at site
(al) Supply and fixing in repair/replacement Electric fan motor 1/10 or 1/12 HP 900 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(am) Supply and fixing in repair/replacement Electric fan motor 1/10 or 1/12 HP 1400 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(an) Supply and fixing in repair/replacement Electric fan motor 1/8 HP 1400 RPM suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(ao) Supply and fixing in repair/replacement Evaporator complete indoor unit body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. Make :- LG/Blue Star/ Voltas/ Totaline /Carrier
(ap) Supply and fixing in repair/replacement Evaporator complete indoor unit body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed . Make :- LG /Blue Star/ Voltas/ Totaline/ Carrier
(aq) Supply and fixing repair/replacement power contactor of rating 11 amps four pole suitable for 415 volts 1.5/2.0 TR split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make L&T type MNX-12
(ar) Supply and fixing in repair/replacement power contactor of rating AC-3, 40 amps three pole suitable for 415 volts with auxillary contacts 02NO+02NC 50 HZ suitable for 3.0 TR (2x1.5 TR) for split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make :- Siemens /L&T
(as) Supply and fixing in repair/replacement power contactor 35 Amps, single pole coil voltage 220 V/230V Model :- MR-I of Make : L&T or equivalent model of make as approved
(at) Supply and fixing in repair/replacement Expansion valve model No. TX-2 with 05 Nos orriface including reducer size 1/2" x 3/8" with 02 Nos flair nuts of size 3/8"
(au) Supply and fixing in repair/replacement Liquid line filter drier of size 3/8" to 1/2" suitable for 3.0 TR three phase split AC Make:- Sporlan /danfoss or as approved.
(av) Supply and fixing in repair/replacement Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
(aw) Supply and fixing in repair/replacementBrass service valve of 5/8" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(ax) Supply and fixing in repair/replacement Brass service valve of 3/8" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(ay) Supply and fixing in repair/replacement Brass service valve of 1/2" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(az) Supply and fixing in repair/replacement Brass service valve of 1/4" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(aaa) Supply and fixing in repair/replacement AC electrical blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 3 speed Make :- Carrier/Voltas/LG/Samsung
(aab) Supply and fixing in repair/replacementVentury made of thermo-coal insulation suitable for Window AC Make: LG/Videocon/Samsung
(aac) Supply and fixing in repair/replacement Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
(aad) Supply and fixing in repair/replacement Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
(aae) Supply and fixing in repair/replacement Air cooled copper condenser coil suitable for split type AC 1.5/2TR including pressure testing, vaccum testing and welding work complete all as specified and directed. Make: samsung / Videocon /Carrier /Voltas/LG
(aaf) Supply and fixing in repair/replacement filter suitable for out unit of split AC 1.5TR/2TR of any make and description complete all as specified and directed.
(aag) Supply and fixing in repair/replacement capillary tube of size 0.075mm suitable for split AC 1.5TR/2TR/3TR and window type AC of any make and description complete all as specified and directed.
Repair of necessary invertor type PCB of any make and any model for split type air conditioner(1.5/2/3TR) complete all as directed and testing for satisfactory operation complete all as specified and directed.
M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed.
Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacity single phase, 50 HZ and reassembling, fixing and testing the dismantled AC in new position after making necessary cutting/opening and making good in window frame complete all as specified and directed Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A'.
Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A
Taking down old unserviceable MS braket of Split AC complete all as specified and directed
S&F MS factory made bracket with powder coated, fixed on wall with neccessory grouting MS bolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed
Taking down old unserviceable voltage stablizer of capacity 4 KVA/5 KVA
Supply and fixing voltage stabilizer electronic type for automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed Make:- Blue Bird / V-Guard or equivalent
Supply and fixing voltage stabilizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed Make:- Blue Bird / V-Guard or equivalent
M&L for MCB Plug and socket DBs with one MCB SP 20 Amps, 10 KA, 'C' Series complete including taking down old nserviceable all as specified and directed Make :- Legrand/ L&T/Havells
Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed
S&F PVC insulated and FR PVC round sheathed copper conductor flexible round cable 1100 volts of size 4 sqmm 4 core multigrade heavy duty complete all as specified and directed. Make :- L&T/Havells/Polycab
All as per item No-15 above but of size 4.0 sqmm 5 core
S&F in replacement of worn out insulating material suitable for copper tubing of split AC's of sizes Internal bore 3/8" and thickness 1/4" complete all as specified and directed, Make:- TotaliNe/Century flex
All as per item No-17 Internal bore 5/8" and thickness 1/4"
All as per item No-17 Internal bore 1/2" and thickness 1/4"
All as per item No-17 Internal bore 1/4" and thicel wags 1/4"
Sepply and replace timer switch with suitable size enclosure to limit the working of split/window Airconditioners of any capacity and make complete all as specified and directed
M&L for MCB Plug and socket DBs with one MCB TPN 32 Amps, rated voltage 240/415 volts AC, complete including taking down old nserviceable all as specified and directed Make :- Legrand/ L&T/Havells
Annual comprehensive maintenance of (New Bldg NFS and 706SU) variable Refrigerant volume (VRV) of 3x7TR capacity with complete servicing of out door/indoor unit twice in six months as per the instrustion of OEM. The spare parts required including charging of refrigerant as recommended by OEM is included in the scope of work. The contractor has to make necessary arrangement for attending unlimite breakdown call during the pendency of the contractor.
Supply, install,testing and commissioning cooling coil working on R-22 refrigirant gas suitable for 11 TR capacity Air cooled AC plant complete including flushing of pipe line and brazing as necessary by arranging N2 gas for checking and oxygen gas for welding works etc all as directed for satisfactory operation of plant complete all as specified and directed.
Supply & fix display board made out of white alluminium border acrylic sheet of 3mm thickness of size 1.5 x 1.5 mtr and vinyl lettering with radium stickaring of size & font as directed by Engineer -in-Charge. The content of display shall be details of plants/equipments, ratings etc obtained & approved from JE/Engineer-in-Charge as directed prior to fabrication of display boards.
Disconnecting, dismantling & taking up/down AC electric motors of any description and in any position from existing foundation of compressor/blowers/pumps/ cooling tower strip opening and dismantling of motor for servicing /overhauling, cleaning oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling motors, ensuring proper alignment of the motor with existing compressor / pumps/blower/cooling tower, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 1 HP to 3 HP 1 Phase/3 Phase 50 Hz
(b) 5 HP Three phase 50 Hz
(c) 10 HP to 12.5 HP Three phase 50 Hz
(c) 15 HP to 20 HP Three phase 50 Hz
Disconnecting, dismantling & taking up/down pump set and monoblock pump sets of AC plant of any description and in any position from existing foundation, strip opening and dismantling of Pumps for servicing/overhauling, cleaning oiling/ greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the pumps ensuring proper alignment of pump, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 3 HP three phase 50 Hz
(b) 5.0 HP Three phase 50 Hz
(c) 10 HP to 12.5 HP Three phase 50 Hz
(d) 15 HP to 20 HP Three phase 50 Hz Notes for Schedule `A' item No 26 & 27 :- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under respective item of overhauling and servicing mentioned here in before. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & from of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bots/washers/ packing etc with new one (iv) Re-metaling of side cover of motor and machinery, polishing for housing of bearing all as required at site for smooth and noiseless movement of rotor impeller shall be measured and paid for separately under appropriate item of Schedule `A’. (v) Re-metaling to pump shaft, polishing and grinding and making to standard size to match with GM Bushes / Neck ring shall be measured and paid separately under appropriate item of Sch`A’
Taking out & removing old burnt out windings and rewinding of electric motors of following sizes with existing size copper super enameled wire including insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing for the following capacities covered vide item 8 and 9 :- (NOTE : Taking down of motor, its servicing & overhauling, fixing on foundation in position, connecting and testing is deemed to be included in the respective item No 13 and 14 of Schedule `A' herein before. (a) 1.0 HP to 3.0 HP Three phase 50 Hz
(b) 5.0 HP Three phase 50 Hz
(c) 10 HP to 12.5 HP Three phase 50 Hz
(d) 15 HP Three phase 50 Hz
(e) 20 HP Three phase 50 Hz NOTE : - Bearing, Bush, Condenser, terminal plates etc will be measured and paid for separately under appropriate item of this Schedule.
Supply only ball Bearing/Roller Bearing of the following Sizes complete all specified and directed by the Engineer-in-Charge. (a) 6202Z
Supply only gun metal bushes suitable for following capacity of pumps of any make/model :- (a) 01 to 05 HP Pump
(b) 10 to 12.5 HP Pump
(c) 15 to 20 HP Pump
Supply only of MS coupling L – 190 for pump and Motor or as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’ item Nos 26 and 27 herein before.
Supply only pump shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only of rotor motor shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of motor of any make/model:- (a) 1 HP to 5 HP three phase, 50 Hz
(b) 10 HP to 15 HP three phase, 50 Hz
(c) 20 HP, three phase, 50 Hz
Supply only pump impeller CI suitable for following capacity of pumps of any make/model:- (a) 3 HP to 5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Disconnecting and taking down existing unserviceable terminal plate of any description and in any position supply and fixing terminal plate, 3 phase, six wire, bakelite, star delta connection as required at site with brass studs, two nuts and two washer complete all as specified and directed for the following capacity of motors : - (a) 1 HP to 3 HP
(b) 5 HP to 10 HP
(c) 12.5 HP to 20 HP
M/s Mahesh Engineering Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .