Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.8 LAccepted-AOC | ₹72.8 L Quoted ₹61.7 L | L1 | Accepted-AOC LOA issued |
| 2 | L2₹72.2 L+₹10.5 L (17.0%)Rejected-Finance | ₹72.2 L+₹10.5 L (17.0%) | L2 | Rejected-Finance L2 |
| 3 | L3₹73.9 L+₹12.1 L (19.7%)Rejected-Finance | ₹73.9 L+₹12.1 L (19.7%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | - | - | Rejected-Technical Non Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
24 Jul 2024, 4:00 pmClosed
CGM(D and S),LAR,APDCL
O/o the CGM(Dand S), LAR,APDCL,Bijulee Bhawan,5th floor,paltanbazar,Guwahati
Construction of 33kV Larica feeder Bay at 132 KV Azara Grid Substation, AEGCL along with associated works on Full Turnkey Mode
2024_APDCL_37708_2
CGM (D)/APDCL/LAR/ Larica DSS/2022-23/ T-128
Open Tender
Electrical Works
Turn-key
240 days
Azara
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,600
₹2 L
O/o the CGM(Dand S), LAR,5th Floor,Bijulee Bhawan
13 Mar 2025
12 Jul 2024
25 Jul 2024
12 Jul 2024
24 Jul 2024
19 Jul 2024
18 Jul 2024
Amount
Supply of Equipment and accessories
33kV, 31.5 kA, 1250 A, Vaccuum Circuit Breaker complete with mounting structure and accessories including Terminal connectors.
33kV, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors. (Short time current rating will be in line with the existing rating at 132 KV Azara GSS.)
33kV, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors. (Short time current rating will be in line with the existing rating at 132 KV Azara GSS.)
33kV, 400/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 Class, live tank type).
33kV Lightning Arrester complete with all fittings and accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing.
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for SAS Integration
ABT compliant energy meter including installation (SAMAST Compliant) ( Secure )
Insulaor strings, Clamps & Connectors (UPG, T Etc.)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper)
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium)
a) 2CX6 sqmm
b) 4CX 16sqmm
b) 3 1/2 C X 35 sqmm
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)
Supply of Marshalling Box for CT
Supply of Marshalling Box for PT
Mandatory Spares For 33kV VCB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e) Complete one no. of VCB Pole compatible to fittings in any phase of the Circuit Breaker.
f) Set of all Gaskets along with sealing agents
33kV, 25kA, 1250A Isolators Contact (01male, & 01 female=01 set)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Clamps & Terminal connectors
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
Description of Work / Item(s)
Amount
F&I of Equipment and accessories
33kV, 31.5kA, 1250 A, Vaccuum Circuit Breaker complete with mounting structure and accessories including Terminal connectors.
33kV, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors. (Short time current rating will be in line with the existing rating at 132 KV Azara GSS.)
33kV, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors. (Short time current rating will be in line with the existing rating at 132 KV Azara GSS.)
33kV, 400/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 Class, live tank type).
33kV Lightning Arrester complete with all fittings and accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing. (F&I)
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for SAS Integration
ABT compliant energy meter including installation (SAMAST Compliant) ( Secure )
Insulaor strings, Clamps & Connectors (UPG, T Etc.) (F&I)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments (F&I)
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper) ( F&I )
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium) (F&I)
a) 2CX6 sqmm
b) 4CX 16sqmm
b) 3 1/2 C X 35 sqmm
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)
Supply of Marshalling Box for CT
Supply of Marshalling Box for PT
Mandatory Spares(F&I) For 33kV VCB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e) Complete one no. of VCB Pole compatible to fittings in any phase of the Circuit Breaker.
f) Set of all Gaskets along with sealing agents
33kV, 25kA, 1250A Isolators Contact (01male, & 01 female=01 set)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Clamps & Terminal connectors (F&I )
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
Description of Work / Item(s)
Amount
Erection of mounting structure as required , including construction of foundation structure
33kV VCB
33kV Isolator
33kV Post Insulator
Erection, Testing and commissioning including laying of control cables and equipment earthing as required
33kV VCB
33kV Isolator
33kV Post Insulator
Installation of earthing system
Installation of earth electrode for LA with test links including construction of covered earth pits.
Construction of extended earth mat using GI flats and connection to risers for equipment earthing as directed.
Construction of Cable trench & slab.
b) D Type
Switchyard PCC and Gravelling
Providing 80mm thick PCC base in prop 1:4:8 as per drawing & specifications including supply of all materials and labour.
Providing switchyard gravelling (100mm thickness) levelling etc as per directive of site engineer.
Installation and commissioning of the C&R panel
Installation in KIOSK, including testing and commissioning of C&R panel.
Integration of C&R panel into existing SAS including Testing and commissioning
Ms HEMEN DEKA (BID ID -235307)
HABI INFRASTRUCTURE (BID ID -235375)
POWER NETWORK ENGINEERS PRIVATE LTD (BID ID -235261)
Ms HEMEN DEKA (BID ID -235307)
Ms HEMEN DEKA (BID ID -235307)
POWER NETWORK ENGINEERS PRIVATE LTD (BID ID -235261)
stage.html
html • 0.05 MB
tech_eval.pdf
PDF • 0.32 MB
boq_comp_chart.xlsx
xlsx • 0.02 MB
fin_eval.pdf
PDF • 0.51 MB
aoc.pdf
PDF • 4.96 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .