AGE(I) Navy Chennai
AGE(I) Navy Fort Saint George Chennai 600009
PROVISION OF SEPTIC TANK AND SOAKAGE WELL FOR INLIVING SAILORS AND OFFICERS NEAR P-11 AND ACCR COMPLEX AT NAVY UNIT IN MEENAMBAKKAM UNDER AGE(I) NAVY CHENNAI
2020_MES_385134_1
AGE(I)/NAVY/CHN/8133 of 2020 - 21
Open Tender
Civil Works
Item Rate
120 days
CHENNAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹15,600
Yes
7 Dec 2020
9 Oct 2020
7 Nov 2020
9 Oct 2020
6 Nov 2020
23 Oct 2020
10 Oct 2020 - 16 Oct 2020
60 days
Amount
Excavation in trenches, not exceeding 1.5 M wide, and not exceeding 1.5 M in depth for foundation etc and getting out in soft / loose soil all as specified and directed by Engineer-in-Charge
Returning filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25cm using approved excavated soil all as directed.
Removing excavated spoil to a distance not exceeding 50 Mtrs and depositing where directed at a level n.exc 1.5m above the starting point all as specified.
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) all as specified directed by Engineer-in-Charge.
M&L for concrete bed to drain pipes of size 150mm bore packing under and completely surrounding pipes after they are laid and fitted in cement concrete, type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge
M&L for mild steel TMT bars 10mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
Use and waste of form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work, not exceeding 200mm thick for fair finished surfaces complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
Material & labour Reinforced cement concrete ( Nominal mix) 1:1.5 : 3, type A1 ( 20 mm graded aggregate) Slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and as directed
Material & labour for rendering 15mm thick in two layers on fair faces of brick masonry surfaces or concrete surfaces, first coat 10 mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instructions finished fair and even complete all as specified and directed. Note : Water proofing compound will be measured & paid separately.
Supply only Integral water proofing compound as approved by AGE(I)
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C2, using 40mm graded granite stone aggregate as in pavings and finished the surface even and smooth complete all as specified and directed by Engineer in charge.
S&F 25mm dia. galvanised mild steel tubes/pipes, medium grade with all fitting and fixed complete to walls or laid in trenches complete all as specified and directed.
S&F 20mm dia. galvanised mild steel tubes/pipes, medium grade with all fitting and fixed complete to walls or laid in trenches complete all as specified and directed.
S&F 25mm gun metal globe/gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F 20mm gun metal globe/gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs 2000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F ball valves of diameter 25mm high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm - 210 gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over one coat of cement primer complete all as specified and directed.
M&L for supply and installation of Fiber reinforced plastic (FRP) based Bio Septic tank capacity of 25000Ltr (25KL) Horizontal cylinderical type suitable for under ground application including excavation and earthwork, PCC bed etc. with all inlet and outlet fittings complete all as specified and directed by Engineer-in-Charge Scope of supply :- Supply & installation of FBST 25-01 Model has a dimension of 22.3 ft lengthx 7.7 ft dia x9.2ft hight with necessary pipe nozzles, disc type partition wall and rib provision. the tank will supply along with 4 Nos of anchor and Nylon belt to neutralize the buoyancy force. Process Discription :- Bio septic tank consists of two chamber and the chambers are divided by disc type FRP partition wall. the first chamber works as a septic tank, where settleable solids are settle down and further degraded aerobically at the bottom zone. the second chamber consists of up flow anaerobic filter, where further removal of reorganic matter tanks place by bio pack media with high surface area. Bio media provider additional surfaces for the growth of organism that purify the sewage further. Make: Sintax/Geogreen or equivalent make as approved by AGE(I)
Construction of Soakage well consisting of excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in 1:6 CM, RCC cover slab in M/25 SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 3.00 Mtr x 4.50 Mtr effecive depth complete all as specified and as shown in drawing (Ref CE Chennai Zone Drg No : TD/ST/748 Sheet No. 1/1)
NVRAGAVANANDSONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .