Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.2 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.4 Cr+₹15.0 L (12.0%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.4 Cr+₹15.0 L (12.0%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.5 Cr+₹21.9 L (17.4%)Rejected-Finance 503 GIRIRAJ HEIGHT VAITY WADI L B S MARG NEAR HARINIWAS CIRCLE THANE 400 602 | THANE | MAHARASHTRA | 400602 | ₹1.5 Cr+₹21.9 L (17.4%) | L3 | Rejected-Finance Other than being lowest |
| 4 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | - | Rejected-Technical Three Class below |
| 5 | Rejected-Technical FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | - | - | Rejected-Technical Three Class below |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
23 Mar 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR ROUTINE MAINTENANCE OF COOLING APPLIANCES AND CONNECTED WORKS UNDER GE NW NOFRA REPAIR AND REPLACEMENT OF OLD DETERIORATED STREET LIGHT POLES AND LED STREET LIGHTS GARDEN LIGHTS ALONG WITH CONNECTED WORKS AT VARIOUS LOCATION AT OUTLAYI
2022_MES_507408_1
8702/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Wise
330 days
GE (NW) NOFRA
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) NOFRA
₹2.0 L
Yes
14 May 2022
11 Feb 2022
25 Mar 2022
11 Feb 2022
23 Mar 2022
9 Mar 2022
11 Feb 2022 - 7 Mar 2022
Amount
Material & labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the Window type air conditioner unit 1.5 Ton capacity complete all as specified and as directed.
All as per item No. 1 above but of 2.0 Ton Capacity.
All as per item No. 1 above but of Split type AC 1.5 Ton Capacity.
All as per item No. 1 above but of Split type AC 2.0 Ton Capacity.
All as per item No. 1 above but of Water cooler 40/60/80 Ltrs. Capacity.
All as per item No. 1 above but of Refrigerator 100/165/180/230 /350 Ltrs. Capacity.
Material & labour for Taking out split /window type Air conditioner any capacity of any make from its original location, removing the dust from body with blower, Servicing & cleaning the condenser and cooling coil by using water and caustic soda checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.0/1.5/2.0 Ton of AC of any make all as specified & directed by Engineer-in-charge.
Material & labour for preparation of old painted surfaces of Water cooler/Refrigerator of any capacity by complete scraping old painting and applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
Supply, install, test & commissioning new compressor sealed rotary/reciprocating type suitable for Window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-charge including taking out old . Make : Voltas/usha Shriram/Bluestar /samsung/Hitachi/videocon/LG/Carrier/Daikin etc. as per existing make at site.
All as per item No 9 above but of 2.0 Ton Capacity.
All as per item No 9 above but Split type of 1.5 Ton Capacity.
All as per item No 9 above but Split type of 2.0 Ton Capacity.
All as per item No 9 above but of Refrigerator 100/165/180/210 /350Liters Capacity.
All as per item No 9 above but of Water coolers 40 / 60 /80 /100/170 Liters capacity
Taking down carefully split type AC of capacity 1.5 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making good existing surface with out any damage to outdoor & indoor unit complete all as specified and directed.
Removing the existing unserviceable coil burnt fan motor from window/Split type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
Supply & fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete all as specified and directed.
Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.0 / 1.5 / 2.0 Ton capacity including removing old fan blade complete all as specified and directed
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade complete all as specified and directed
Replacement of starting capacitor 60 - 80 mfd.Make:(SARADA/UNIQUE/ KELTRON) complete all as specified and as directed.
Replacement of starting capacitor 80-100 mfd.Make:(SARADA/UNIQUE/ KELTRON) complete all as specified and as directed.
Replacement of running capacitor 25 MFD (Make : Asian / Epcos) complete all as specified and as directed.
Replacement of running capacitor 36 MFD (Make : Asian / Epcos) complete all as specified and as directed.
Supply & fix of thermostat switch for split /window type AC of capacity 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral / Arnapurna) complete all as specified and as directed.
Replacement of thermostat switch for Water Cooler of any capacity (Make :- Indofoss / Ranutral / Arnapurna) complete all as specified and as directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for Window/Split type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity complete all as specified and as directed.(Make : Arvind / Usha / Microtek)
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity complete all as specified and as directed. (Make : Arvind / Usha / Microtek)
Supply & fix of Float valve suitable for Water cooler of any capacity complete all as specified and as directed.
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and as directed.
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as directed by Engineer-in-Charge
Supply and lay PVC flexible pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete all as specified and as directed.
Supply & fix push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity complete all as specified and as directed.
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps all as specified & directed by Engineer-in-Charge.
Taking out old unserviceable condenser coil of 1.5/2.0 Ton split/Window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.
Removing electronic unserviceable printed circuit boards(PCB) from split type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system and testing complete all as specified and directed by Engineer-in-Charge.
Supply & Fix blower fan motor capacitor 4 MFD (Make : Asian / Keil) complete all as specified and as directed.
Supply & Fix blower fan motor capacitor 6 MFD (Make : Asian / Keil) complete all as specified and as directed.
Supply of sensor cord less remote handset suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by Engineer-in-Charge.
Supply & fix Condensing unit bracket stand of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers etc complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of indoor unit of split type AC 1.5 TR cap having 3 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. (Note :- Old unserviceable indoor unit will be deposited to MES store)
Repair/replacement of outdoor unit of split type AC 1.5 TR cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. ( Note :- Old unserviceable outdoor unit will be deposited to MES store)
Supply & fix in repairs UPVC Pipes of size 15 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply & fix in repairs UPVC Pipes of size 20 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply & fix in repairs UPVC Pipes of size 25 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 15 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 20 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 25 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix concussive push button taps of size 15 mm of cast copper alloy suitable for to connect with UPVC pipe complete all as specified and as directed.
Supply and fix ball valves of high pressure PTMT with epoxy coated high density plastic of sizes15 mm bore complete all as specified and as directed.
Supply and fix ball valves of high pressure PTMT with epoxy coated high density plastic of sizes 32 mm bore complete all as specified and as directed.
Maintenance, repair and servicing/cleaning of kitchen hood blower of10000 CFM 440V V-belt drive for fresh air and exhaust air at INS Shikra Sailors Galley /DSC mess/ WNC (O) Mess complete all as specified and as directed.
Maintenance, repair and servicing/cleaning of kitchen hood V shape with side oil filter matt finish and fresh air, aluminium grill with damper with GI 20 frame and 24 flap oil filter with oil drain complete all as specified and as directed. Hood size - 7500 x 3150 x 600mm (Height) Oil filter size 500 x 500 (Height) x 50 = As per Qty existing at site.
Material & labour for Rewinding of unserviceable Blower motor of 7.5 HP capacity 3 phase 50 Hz 415volt complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8 hours continuously to check the RPM etc. to the satisfactory performance etc. complete. Loc : WNC (O) Mess / INS Shikra Sailors Galley /DSC mess NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
All as per item No 52 above but motor capacity 1 HP for centralised water cooler complete all as specified and directed Loction WNC (O) Mess/ INS Shikra/ Pasta Lane.
Servicing/ repairs/ maintenance including replacement of minor spare parts of Centralised water cooler system of capacity 1000 Ltrs. installed at WNC(O)Mess/ Pasta Line complete all as specified and directed by Engineer-in-Charge.
Servicing/ repairs/ maintenance including replacement of filters, flexible pipes of any water purifier system complete to match the existing and connecting up with existing system complete all as specified and directed by Engineer-in-Charge.
Removing electronic unserviceable PCB from water purifier system and replacing with new circuit boards and connecting with system and testing complete all as specified and directed by Engineer-in-Charge.
Supply & charging refrigerant R-22 Gas as per requirement complete all as specified and as directed .Make:mafron or as approved by GE
Supply & charging refrigerant R-134 Gas as per requirement complete all as specified and as directed. .Make:mafron or as approved by GE
Supply & charging refrigerant R-32 Gas as per requirement complete all as specified and as directed. .Make:mafron or as approved by GE
Excavation in trenches not exceeding 1.5 mtrs. wide and not exceeding 1.5 mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Cutting and removing grass, vegetation bushes etc and brooming from surrounding water supply electric supply installation and removing small qty concrete debries / removing all rubbish to a distance not exceeding 100 m as directed and cleaning/ brooming in water /electric supply station/LT panel/street light area complete twice in a month all as specified and directed by Engineer-in-Charge.
Trimming tree branches on the route of LT line nearer to LT/HT line , pump house, street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
Dismantling steel poles/struts, any size from existing detorated street pole complete all as specified and directed by Engineer-in-Charge.
Checking and repairs to street light fitting ,Junction box , cable lugs , cable joint, MCCB, MCB, DB etc from Truss , Hanger, Helipad ,Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Avaition light fittings inside / out side of INS SHIKRA , NT POOL, SASSON COMPLEX , BOOT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignator, holder, rectifying the defects if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman.
Taking down old unserviceable transformer.Supply and fixing in repair of Isolating transformer,series to series 200 w, 5000 volts,current ration 6.6/6.6 amps suitable for Helipad identification light (CCR) Light fittings complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting and S&F of luminaires integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 nos. LED are provided as per site requirement , complete all as specified and directed by Engineer-in-Charge. Make - Bajaj/ Havells / Phillips .
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable junction box and S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable street light and fixing only 45 watt LED new generation energy saving and environmental friendly long life LED street light. Note : For Ser No 71 to 74 Street light 45 /70/120 watt street light any type any height and high bay light/flood light issued against sch "B" store free for fixing and colled to CDS store from BSO yard and Cost included 1.5 Sqmm 2 core cable for connection Junction box to light, transport charge and labour charge for collection from CDS store to site complete all as specified and as directed.
Taking down old unserviceable street light and fixing only LED Bldg security light 70 Watt indus series powder coated pressure die cast aluminium high power LED security light with heat resistant toughned glass with lens with IP66 Protection complete all as specified and as directed.
Taking down old unserviceable street light and fixing only 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and as directed.
Taking down old unserviceable street light and fixing only Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/round bar flat iron with clamping as good appearance complete all as specified and as directed.
S&F in Replacement LED driver for street light / highbay light fitting / flood light from120 to 240 Watt of any type and size etc to match with existing model /size complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaquar /Shakti
S&F in Replacement LED driver for street light / highbay light fitting / flood light from 70 to 90 Watt of any type and size etc to match with existing model /size complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaquar /Shakti
S&F in Replacement LED driver for street light / highbay light fitting / flood light from 45 to 48 Watt of any type and size etc to match with existing model /size complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaquar /Shakti
Supply and fixing in repair Steel tubular swaged street light poles and arms (Bracket) 45 degree angle fixed with 02 Nos iron clamps cast iron base plate ,final taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately)
Supply & fix in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 7 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket, tapper plug,bolts nuts and screws etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete all as specified and directed by Engineer-in-Charge.
Dismantling & Repair Static Frequency Converter of capacity 60 KVA, carefully from its original position and repair & overhauling , fabrication,carrying with new essential parts complete all as specified and directed by Engineer-in-Charge.
Dismantling & Repair Static Frequency Converter of capacity 05/03 KVA, carefully from its original position and repair & overhauling , fabrication,carrying with new essential parts and replacement 15 Nos old battery complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable clamp and Supply and fixing iron clamp (flat 25 x 4 mm) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply and fixing of new bracket for street/security light fitting made of GI pipe 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
Material and labour for straight through jointing heat shrinkable kit for cable of 240/300 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Material and labour for straight through jointing heat shrinkable kit for cable of 95 to 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Taking up old U/S XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including Old concrete cable cover from trenches/walls/ceiling/poles etc any size complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Cable and fixing/laying only XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : For Ser No 87 to 89 XLPE Cable 25 Sqmm ,35 Sqmm , 50 Sqmm, 3.5 core issued against sch "B" store free for fixing and colled to CDS store from BSO yard and Cost included transport, labour charge store to site , Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Taking down old unserviceable Cable and fixing/ laying only XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Cable and fixing only /laying XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and as directed.
Fixing only of MCCB sheet metal enclosure suitable for holding of MCCB of 100/400 amp capacity four pole type including fixing accessories etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no -607906 or its equivalent in Siemens / GE.
Material and labour for PCC 1:3:6 type C2 (using 20mm graded stone aggreagate) for base of pole including use and waste of form work complete all as specified and directed by Engineer-in-Charge.
Material and labour for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) for coping of pole complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
Free for fixing / laying HDPE of pressure rating 6kg/cm sq pipe of 75 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Note : For Ser No 94 to 95 HDPE pipe issued against sch "B" store free for fixing and collected to CDS store from BSO yard and Cost included transport, labour charge store to site , including cutting as required length to be included in quoted rate and no extra payment will be made for it.
Free for fixing / laying HDPE of pressure rating 6kg/cm sq pipe of 65 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
Material and labour for scraping the old paint from steel tublar poles by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
Material and labour for refixing & secure hanging of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
Material and labour in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm complete all as specified and as directed.
Material and labour for refixng of Old uprooted Air Termination Rods including saddling with suitable saddles and nails all as directed at site by Engineer - in - Charge.
Material and labour in Replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Materal and labour for in repair CPT Cirprotec CPT-L ESE Lighting rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on principle of early streamer emission technology which will offer level 1 protection for upto 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to protected complete all as specified and directed.. make:- NIMBUS-JEF Techno or erico as approved by GE
Supply and erection of in repair mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on building complete all as specified and directed.. Make:- NIMPUS-JEF Techno or erico as approved by GE
Supply and fixing of in repair 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Supply and fixing in repair 4 digital electromechanical lightning event counter in weather proof resistance complete all as specified and directed. Make:- JEF Techno or erico as approved by GE
Supply and fixing of in repair test link for connecting the earth pit and down conductor complete all as specified and directed.. Make:- JEF Techno or erico as aaproved by GE
Material & labour for in repair maintanance free enviroment friendly earth elctrode set comprising of 17.2mm dia, 3m long rod low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANS/INSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 Ibs) complete all as specified and directed.. make:- JEF Ecosafe or erico as approved by GE
Material and labour for in repair PCC pit 1:2:4 type B-1 ( using 20mm graded stone aggregate), earthing pit cover reinforced with XPM, weight not less than4kg/sqm and 6mm dia bar handle earth pit angle iron frame of size 25x25x3mm complete all as specified and directed.
Testing of earthing for earth resistance provided for various electrolde panels/bldgs/main DBs etc all as per clause 19.146.3 of SSR part-I and recording the test results complete including providing earth megger and test leads complete all as specified and as directed. (Note :- The results are to be recorded in register as directed by Engineer-in-charge)
Repair /replacement of earth wire, earth continuty conductor , where the voltage between earth line & neutral . More than 3 volts , tighting of wire nut bolts of pannel board, DB's etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation complete all as specified and as directed.
Material and labour for PCC 1:4:8 type C2 (using 40 mm graded crushed stone aggregate) for plinth protection of semi under tank and support to main water supply line all as directed by Engineer-in-Charge.
Material and labour for repair of brick masonry valve pit of size 75 x 75 x 75 cm (finished internal dimensions ) and 15 mm thick on internal wall surface finished even and smooth external using extra cement and plaster in cement mortar 1:4 and painted flush externally as posible and 50 mm thick PCC 1:2:4 type B-1 for copping and fixing new angle iron frame 40 mm x 40 mm x 6 mm with 4 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil and demotition of demolihon existing valve pit complete all as specified and directed by Engr-in-Charge
Material and labour for repair of brick masonry valve pit of size (105 x 105 x 105cm (finished internal dimensions ) using sub class "B" brick masonry in cement mortar cm 1:4 including plastering internally and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in copping with angle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil to distance n.exc 50 m all as specified and directed by Engr-in-Charge
Repair to broken brick masonry valve pit of size (1.2 x 1.2 x 1.0) mtr and 1.0 m x 1.0m x 0.75 M (finished internal dimensions ) and remove the old plaster and usingmortor for plaster in in cement mortar internally and painter flush externally as posible and PCC 1:2:4 type B-1 for copping and providing new MS sheet 4 mm thick cover of suitable size made of angle iron frame 40 mm x 40 mm x 6 mm with 4 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil all as specified and directed by Engr-in-Charge
Material and labour repair and replacement of rusted /broken rubber packing both side of non return valve of CI body 80/ 100/150 mm bore. Opening both side flanged with rubber packing including nuts bolts and wahsers etc complete as directed by Engr-in-Charge
Material and labour for drain out the water with the help of pumping set/Honda Gen set/by manually from the semi under ground sump of capacity 30 thousand ltrs to 2 lakh ltrs capacity for welding work complete all as specified and as directed.
Rough excauation removing disintigrated material/rock/ mud/other silt wasted by diging at Pump house and power house to semi under ground tank for drain out of rain water and depositing 50 mtrs away as directed by Engr-in-Charge
Taking down unserviceable centrifugal pump air release and in repalcement of new PVC air release valve as per sample directed by Engr -in- Charge
Material and labour for rubber gasket joint and flanged pipe 150 mm dia pipe , complete with jointing materials for jointing fittings with pipe all as specified, (Excavation shall be measured and paid separately
Material and labour for rubber gasket joint and flanged pipe 80 mm to 100 mm dia pipe , complete with jointing materials for jointing fittings with pipecomplete all as specified and as directed. (Excavation shall be measured and paid separately
Taking out old rusted pipe as per existing site and welding/ cutting work for MS pipe of any dia fixing of pipe as required shape and length for motor and pumps complete all as specified and as directed.
Material and labour for Painting of CI/GI pipe line 40 mm to 150mm inside the pump house and out side each pump house and all sluice valve, NRV gate valve) with one coat of synthetic enamel black/gray paint of existing colour shade with spray gun machine and after cleaning and preparation of surfaces complete all as specified & directed by Engr-in-Charge
Taking down the broken iron coupling frommotor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts as per sample for the following capacity .
Repair and replacement of burnt of capacity 160 to 400 Amps MCCB connecting patti / cable lugs and strip opening of MCCB from the panel and taking out burnt lugs/ cables and copper lugs fix new MCCB patti nut, bolts and lugs all as directed by Engineer-in-Charge. .
Repair and replacement of burnt panel aluminium bus bar of capacity 200 to 400 Amps taking out burnt aluminium bus bar and fixing with new bus bar minimum 05 mtrs with necessary fitting and fixtures , addition, alteration of existing panel complete ass as specified and directed by Engr-in-Charge
Taking out rusted LT insulation rubber mat and through out the out side of pump house and fixing /lay new electrical LT insulation rubber matting as per ISI of size 1m x 2m x 12 mm thick. Make : Jaipuria Brothers or equalent make approved by GE
Supply an fixing Nut and bolt of black bolt with hexagonal head and nuts round necks with washer of size 16 mm diameter and 100 mm length complete all as specified and as directed.
Taking down of leakage /rusted pipe from the existing position and repair to leakage GI pipe line of size of following dia pipe including by threading / welding &/ the earth work and labour charge all as directed by EIC.
(a) 25mm bore
(b) 40mm bore
(c) 50mm bore
Taking down of leakage /rusted 100 GI delivery pipe from the existing position pump house and replace with new GI pipe line of size 100 mm by threading / welding work / labour charge and including the earth work all as directed by EIC.
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump each pump house after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Disconnecting all electric connections from the submersible pump & motor 03 HP & taking out column assly from bore well and transporting the same to civil workshop for repair . directed by Enge -in-Charge.
Material and labour for fabricating positioning glow sign board for E/M iinstallation map plot lay out. Translite glow sign made of PVC sheet box frame with aluminium angle support and four (04 side ) angle iron frame for fixing of board and name of stn/ mob No and other information writing on acrylic sheet 1.2 m x 0.90 x 0.15 m size/coloured glazed lettering on white acrylic sheet back ground using super glow paint and provided with flourescent glow LED light using 1 x 36 watt tube light fitting including internal wiring inside the box, external point wiring from the nearest DB including wall mounting all as directed by Engr-in-Charge
Taking out burnt / damaged cable from panel to motor replacement with new single core copper conductor cable PVC insulated of size 35 sqmm , 1100 volt conforming to IS 694/1990 including UPVC pipe complete all as specified and as directed.
Taking out burnt / damaged cable from panel to motor ,replacement with new single core copper conductor cable PVC insulated of size 10 sqmm , 1100 volt conforming to IS 694/1990 including UPVC pipe complete all as specified and as directed.
Material and labour for joints with 15 mm thick MS flanges slip type through welded to MS pipes complete with jointing materials such as rubber, gasket, nut bolts and washer etc for 100 mm bore pipe complete all as specified and as directed.
Material and labour for joints with 15 mm thick MS flanges slip type through welded to MS pipes complete with jointing materials such as rubber, gasket, nut bolts and washer etc for 150 mm bore pipe complete all as specified and as directed.
Dismantling and taking down old u/s power contractor of any make and supply and fix 3 pole power contaractor suitable for motor of 40 HP complete all as specified and as directed.
Dismantling and taking down old u/s power contractor of any make and supply and fix 3 pole power contaractor suitable for motor of 70 HP type complete all as specified and as directed.
Dismantling and taking down old u/s timer and supply and fix timer suitable for motor upto 40 HP complete all as specified and as directed.
Dismantling and taking down old u/s timer and supply and fix timer suitable for motor upto 50 HP to 70 HP complete all as specified and as directed.
Dismantling and taking down old u/s relay and supply and fix relay as per existing make and capacity suitable for motor upto 20 HP to 70 HP Make- L & T/ Havells and equivallent as approved by GE.
Taking out old rusted and broken semi under ground sump lid and angle frame and replacement new lid made out MS sheet / cast iron as per existing hole including locking arrangements RCC water tank all as directed by Engr-in-Charge
Taking out old rusted and broken building over head tank lid and angle frame and replacement new lid made out MS sheet / cast iron as per existing hole including locking arrangements RCC water tank 10000 gallons capacity all as directed by Engr-in-Charge
Taking out burnt cable by excavation from main panel to motor panel and replacement aluminium conductor XLPE cable insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 of size 185 Sqmm 3.5 Core with both side aluminium lugs nut bolts etc and including earth work , returning and filling complete all as specified and as directed.
Disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the unserviceable pump set of any make from pump houses after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacene the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electric connection to the motor and testing complete to entire satisfaction of Engineer-in-Charge for the following capacity.
(a) Centrifugal pump set of capacity 75HP
(b) Centrifugal pump set of capacity 40HP
(c) Centrifugal pump set of capacity 20HP
(d) Centrifugal pump set of capacity 5 HP
Material and labour for rewinding the electric motor of capacity 60HP to 75 HP capacity, disconnecting the electric connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following works deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rotar and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing and paper removal all carbons. (c) Insert insulating materials such as insulating paper sleeves. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed.
All as per srl item No.146 here in before but Centrifugal pump set of capacity 55 Hp
All as per srl item No.146 here in beforebut Centrifugal pump set of capacity 40 Hp
All as per srl item No. 146 here in before but Centrifugal pump set of capacity 20 Hp
All as per srl item No. 146 here in before but Centrifugal pump set of capacity 5 Hp
Material and labour for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the foundation beds with MS channels angle of the required as per pump set capacity( 40 HP to 75 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and reerection the pump and taking out old PCC approx 1.2 feet depth and 1.5 mtr length, 1 mtr width and fix new RCC material 1 : 2 : 3 ratio and fixing new 06 No nut and bolts 1.2 feet long for loading of motor iron foundation and motor testing to the entire satisfaction of Engineer-in-Charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including Concrete required for foundation complete all as specified and as directed.
Material and labour for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the foundation beds with MS channels angle of the required as per pump set capacity( 15 HP to 35 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and reerection the pump and taking out old PCC approx 1.2 feet depth and 1.5 mtr length, 1 mtr width and fix new RCC material 1 : 2 : 3 ratio and fixing new 06 No nut and bolts 1.2 feet long for loading of motor iron foundation and motor testing to the entire satisfaction of Engineer-in-Charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including Concrete required for foundation complete all as specified and as directed.
Disconnecting electric supply from motor, removing wornout coupling rubber packing and supply and fix new coupling packing for the following:-
(a) 40 to 55 HP motor
Taking out old unserviceable water meter from the existing position by unscrewing the nut andbolts and replacement new water meter suitable to fit in 150 mm bore in existing GI/CI pipe complete with flange, gasket, nuts, bolts and all necessary required items all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable water meter from the existing position by unscrewing the nut andbolts and replacement new water meter suitable to fit in 100 mm bore in existing GI/CI pipe complete with flange, gasket, nuts, bolts and all necessary required items all as specified and directed by Engineer-in-Charge.
Material and labour for scrubbing old paints from outer surface of plants and equipment including painting with two coat of synthetic enameled paint over one coat of red oxide paint and also writig AM/MES Nos on surface of the plant with white paint all as specifed and directed by Engineer- in -Charge. The following pump and motor as under :-
(a) Pump and motor set from 60-75 HP including suction and delivery upto 15 Mtrs
(b). Pump and motor set from 5 -55 HP including suction and delivery upto 15 Mtrs
Taking down old broken pvc pipe and valve from priming tank to pump by cutting of wall / tank connection / motor connection and replacement with new Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 and PVC valve fixed complete to walls, ceilings or in floors etc including clamps and screws and all as specified and directed by Engineer-in-Charge.
Cleaning of PVC/RCC tank in any position by rubbing, washing removing the scales dust etc including plugging the inlets dusting washing all as directed for tanks
(a) Capacity 3000Ltr
(b) Capacity 5000 Ltrs
(a) Capacity 10000 Ltr
Repair/Maintenance to Chlorine dozing system assembly with chlorine injector dozing pump, cleaning, servicing, carrying out minor repairs and testing complete all as specified and as directed. (Note : (a) Work is including consumables like cotton waste cloth etc. (b) Parts and spares requied to be replaced.
Supply & fixing in replacement of dosing Pump high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc complete all as specified and as directed. Make:- Rayalaseema hi strength Hypo Ltd or equivalent as approved by GE
Supply and Fixing in replacement of dosing system consisting 40 ltr-100 ltr PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank complete all as specified and as directed. Make:- Rayalaseema hi strength Hypo Ltd or equivalent as approved by GE
Supply only Calcium Hypochlorite in granular form having minimum 70% of available chlorine (Ca(OCI)) with anti-corrosive and anti-scaling properties suitable for human consumption. Note: Contractor shall produce letter of authorisation, COA with unique serial number and NSF certiifcate from manufactuer. Make:- Rayalaseema hi strength Hypo Ltd or equivalent as approved by GE
Taking out broken PVC lid and Supply and fixing PVC polyethylene water storage tank lid of any capacity with locking arangement and fixed 01 lock each tank as specified and directed by Engineer-in-Charge.
Strip opening of 100 / 150 mm NRV top cover and taking out of unserviceable and damaged flap cover and change new flap cover and lather sheet including nuts bolts and wahsers etc complete as directed by Engineer-in-Charge.
Taking out unserviceable and broken/ damaged brass gate of 40/50 mm gun metal Valve and Supply and fixing in replacement 40 mm of gun metal gate with iron wheel head all as directed by Engr-in-Charge
Taking out unserviceable and broken / damaged brass gate of 80/100 mm gun metal Valve and Supply and fixing in replacement new brass gate with iron wheel head all as directed by Engr-in-Charge
Water testing report of BASIC TEST / HEAVY METAL TEST /PATHOGENS TEST as per list . Collection of empty sterlised bottles from the Govt/ authorised lab Mumbai , Maharashtra after taking out water sample from user end / pump house. Water sample filled bottle depositing to the same lab for anaylsis test and collect the sample report and deposited to E/M sub divn all as directed by Engr-in-Charge Location : Reviera/ INS Shikra/ NT Pool/ Sasson Complex/ Bhagirathi/ Aditi/ Vishakha
Repair to unserviceable sluice valve of size 80 mm to 150 mm dia. Opening the nut,bolts both side flanged ,after taking down unscrew the top cover and taking out the spendle , gate with chucknut complete all as specified and as directed.
Repair to unserviceable sluice valve Gland plate . Supply and fixing Gland plate with nut and bolts of size 100 mm dia complete all as specified and as directed.
Repair to unserviceable sluice valve Gland plate. Supply and fixing Gland plate with nut and bolts of size 150 mm dia complete all as specified and as directed.
Repair to unserviceable sluice valve Gland plate. Supply and fixing Gland plate with nut and bolts of size 80 mm dia complete all as specified and as directed.
Repair to unserviceable sluice valve brass spindle . Supply and replacing the brass spindle of size 100 mm dia sluice valve complete all as specified and as directed.
Repair to unserviceable sluice valve brass spindle . Supply and replacing the brass spindle of size150 mm dia sluice valve complete all as specified and as directed.
Repair to unserviceable sluice valve brass spindle. Supply and replacing the brass spindle of size 80 mm dia sluice valve complete all as specified and as directed.
Repair to unserviceable sluice valve gate checknut . Supply and replacing the Gate chucknut of size 80 mm dia sluice valve complete all as specified and as directed.
Repair to unserviceable sluice valve gate checknutSupply and replacing the Gate chucknut of size 150 mm dia sluice valve complete all as specified and as directed.
Repair to unserviceable sluice valve gate, checknut Supply and replacing the Gate chucknut of size 100 mm dia sluice valve complete all as specified and as directed.
Opening of nut and bolt for the pump and Taking out pipe / unserviceable/rusted foot valve and replacement with new foot valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. and fix the pipe/ valve in water tank / pump complete all as specified and directed by Engr-in-Charge.
Opening of nut and bolt for the pump and Taking out pipe / unserviceable/rusted foot valve and replacement with new foot valve, 100 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified and directed by Engr-in-Charge.
Routine maint of centrifugal pump / NRV / sluice valve/Non return valve by attending fault testing of system regularly basis to insure serviceability and checking of system , including replacement of unseriviceable component including preventive maintinance spares by replacing minor parts i.e galand packing nut and bolts complete all as specified and as directed. Note :- If the contractor will not attend the complaints by his trades man in any working day , the necessary reovery of Rs. 500/- per day shall be imposed complaint not attended within 24 hrs and checking of non ops pumps /valve /foot valve each location in routine wise per day by trades men.
Taking down old unserviceable pressure gauge with the help of gas cutter/ monkey packed and in replacement new Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm directed by Engr-in-Charge.
Taning out unserviceable submersible pump from the bore well and supply and fixing 3 HP submersible pump 3 phase 420 Volt all as per directed by Engr- in-Charge .
Disconnect the electric connections form starter and taking out burnt submersible starter from the existing position. Supply and fixing new water sensor, starter 3 phase of 10HP , 440 Volt , front side openable and locking arrangement all as per directed by Engr- in-Charge .
Manning and operation of water supply installation consisting of electrically operated pump sets of different capcity including firefighting pumpsets at vishakha.Vadadana,Vatsala pump, Foma house house ( for fresh water) including sunday and public holiday by one valve man in each shift and one FGM in each shift for all installations and maintanence of log book , taking care of pumps / valves/overflow of tanks and other minor repairs and leakages daily in three shifts from 1200 hrs to 2000 hrs and 2200 hrs to 0600 hrs (02 shifts ) = 04 persons including sunday/holiday all as specified and directed.
All as per Srl No. 179 here in before but one valve Man (in each shift) in two shift at Aditi/Ahilya Building from 1200hr to 2000hrs and 2200hr to 6000hr complete all as specified and as directed
All as per Srl No. 179 here in before but one valve man in one shift at Reviera Building from 1400hr to 2200hr complete all as specified and as directed
All as per Srl No. 179 here in before but one valve man (in each shift) for two shifts at Sasson Complex pump house from 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs complete all as specified and as directed
Notes for Item Nos 179 to 182: The rate quoted shall be deemed to be included the following :- (i) The shift time shall be first shift 0600hrs to 1400hrs, second shift 1400hrs to 2200hrs & third shift 2200hrs to 0600hrs.. (ii) The contractor has to apply for entry pass, for the labours to be employed against the work, from Naval Police with valid documents and shall submit Police verification of labours after receipt of work order through GE (iii) Operator must be skilled & must have knowledge of operation & maintenance of Pump Sets, DG Sets, Panel and controlling valves etc. (iv) Valve Man must be semi skilled & must have knowledge of controlling valves etc. (v) Consumable stores such as cotton waste, Grease including tools required shall be provided by the contractor. (vi) Operator must ensure cleanliness of Pump Sets/DG Sets/Panels and Pump house bldg. (vii) The rate quoted by the contractor shall be inclusive of Life insurance for the tradesmen employed by him in case of untoward incident such as injuries, fracture or casualty while on duty. (viii) Carrying out minor repairs viz. replacing blown out fuses, recharging MCCBs, priming of pumps, repair to pipe lines as directed. (ix) Checking of leakage /water level in the radiator,checking of leakage of oil from the engine ,compressor etc, shall be carried out by the operator.
(x) Inform the JE/AGE E&M in charge of any electric faults, water supply failure, Diesel requirement for Gen Sets and any other mishappenings. (xi) Any Major repair of Machineries, replacement of batteries and filing of Diesel for Gen Set will be carried out by the MES. (xii) Any other work, not specifically mentioned above, but ordered by the Engineer-in-Charge for the smooth functioning of Pump House for supply of water will have to be carried out without any extra cost. Rates quoted shall be deemed to be included accordingly (xiii) Rate quoted shall be inclusive for Relief Staff to the persons employed in shifts. (xiv) After issue of work order, contractor has to submit the list of employees including reserve alongwith relevant documents as mentioned is PS to the Engineer-in-Charge. (xv) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (xiv) Contractor has to submit proof of payment of EPF subscription made by him alongwith RAR failing which RAR will not be progressed for payment. (xvi) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xvii) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that shift will not be paid. In addition to that a penalty of Rs 700/- per shift per person will be recovered from contractors dues. Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any. The contractor shall have no claim on this account.
(xviii) Contractor has to supply three sets of Tools and Plants to the labours employed by him and should be placed with the safe custody of department. Rates quoted shall be deemed to be included the above provision. (xix) In case any variation in manpower as indicated in Column No 4 of BOQ due to any reasons / or any manpower held in Department or any policy change contractor should have no claim on that account. The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost of work mentioned in BOQ item Nos 179 to 182 ie Rs 2752321.00, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2). The deposited amount shall be the difference between estimated cost Rs 2752321.00 and amount quoted by lowest bidder. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of FDRs of equal amount as mentioned above. The FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be
cooltech engineering services
United Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .