Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-AOC ALWAR | 1 | Accepted-AOC L-1 Bidder | |
| 2 | 2₹4.6 L+₹1.0 L (28.4%)Rejected-AOC | 2 | Rejected-AOC L-1 Bidder | |
| 3 | 3₹7.0 L+₹3.4 L (92.9%)Rejected-AOC | 3 | Rejected-AOC Not L-1 Bidder | |
| 4 | 4₹11.7 L+₹8.1 L (223.5%)Rejected-AOC | 4 | Rejected-AOC L-1 Bidder | |
| 5 | Rejected-Technical 59 KARNAWAS KARNAWAS KARNAWAS REWARI HARYANA 123401 | REWARI | HARYANA | 123401 | - | Rejected-Technical Techno-commercially not acceptable |
Tender Value
Refer Docs
Closing Date
13 Jul 2020, 3:00 pmClosed
DGM (CSR and Learning and Devp)
INDIAN OIL CORPORATION LIMITED (PIPELINES DIVISION) NORTHERN REGION PIPELINE P.O.PANIPAT REFINERY BAHOLI, PANIPAT-132140
Annual Rate Contract for Servicing and Maintenance of Fire Fighting Equipment at NRPL Bathinda
2020_NRPNP_116937_1
PNP20011
Open Tender
Services
Works
365 days
NRPL Bathinda
Please refer Tender documents.
9 documents required · 9 mandatory
Exempted
12 Oct 2020
29 Jun 2020
14 Jul 2020
29 Jun 2020
13 Jul 2020
3 Jul 2020
Amount
SERVICE ITEMS
Checking, Inspection, Servicing and Maintenance of Fire Fighting System, equipments hydrants,, extinguishers of all type ,Water/ foam monitor as per OISD/ISI Standards to provide best functioning of the equipments always in best healthy condition inclusive of periodically cleaning ,checking/inspection/oiling/greasing of assemblies such as coupling, .nozzles ,valves, hydrants, extinguishers, hose pipes ,water/foam monitors, nozzles foam monitor, hose boxes ,sand buckets etc, updation of the data & identification tags , recording the status of checking in history register etc. as directed by the Engineers in charge with all labors ,tools and tackles and materials etc. complete.(inspection and servicing of the equipment/Fire Fighting facilities is to be done periodically as mentioned against each):-
Maintenance and inspection of double headed hydrants as perdirection of EIC. Reporting to be done as per owner supplied format including oiling , greasing , testing as per direction of EIC inclusive of all tools & tackles, consumable, transportation, labour charges etc
Maintenance and inspection of Fire Extinguishers of all types & Capacity as perdirection of EIC. Reporting to be done as per owner supplied format including cleaning, filling of DCP Powder, replacement of CO2 cartridge/washer/Cap/Discharge Pipe/Squeezing Grip etc. if required as per direction of EIC inclusive of all tools & tackles, consumable, transportation, labour charges etc
Maintenance and inspection of Fire Hose as perdirection of EIC. Reporting to be done as per owner supplied format including cleaning, replacement of washer/spring/lock etc. if required as per direction of EIC inclusive of all tools & tackles, consumable, transportation, labour charges etc
Maintenance and inspection of Hose Box as perdirection of EIC. Reporting to be done as per owner supplied format including cleaning, replacement of front glass/key box glass/key/rubber gasket etc. if required as per direction of EIC inclusive of all tools & tackles, consumable, transportation, labour charges etc
Maintenance of all kind of isolation valves of all sizes in Fire water line, Hydrants, Monitors, Tank sprinkler line and Tank foam line by opening the same, lapping, greasing, oil as required for the job with supply of all man, material greases required for the work.
Maintenance and inspection of Foam / Water Monitors by Cleaning, greasing, oiling, operating in 360 deg. for any kind of blockage/damage as per direction of EIC inclusive of all tools & tackles, consumable, transportation, labour charges etc.
Maintenance and inspection of Nozzles all types including foam branch by cleaning and checking of its efficiency by operating
Maintenance of Sand buckets with supply of sand for all bucket by cleaning and refilling with sand if required.
Maintenance of Foam Trolley & All Foam tank 200/1000 ltr. Capacity by cleaning, refilling with AFFF, checking of HOSE condition, checking fitted foam branch, checking level of AFFF as per the instruction of EIC/SE inclusive of labour charges, tool tackles and transportation.
PPE maintenance / up keep on Monthly Basis like as helmets., Breathing Apparatus -,Water jel blanket, Resuscitation set, Fire proximity suite-Goggles, Belts, Stretcher and other PPES as per instruction of Engineer-in-Charge .
Filling of foam compound/foam solution in foam tanks of fire fighting system in station area through 30L jerry cans including labour, collecting foam cans etc. in all respect. (Rates per 30L jerry cans)
Cleaning & stacking properly the foam containers,updating stock ,date of expiry,date of manufacturing on board and in register,placing foam containers at the foam monitors and water hydrants.
Inspection, maintenance and dechocking of foam maker of foam line and flushing with water, refitting back the foam maker & making it leak tight & testing the same including all labour, materials, tools and tackles complete in all respect with the gaskets, nuts and bolts. Foam if required for testing shall be supplied by IOCL.
Cleaning/ De-chocking of nozzles of water spray system at Transmix tanks and water curtain system at Control Room Building by opening nozzle, dechocking & refitting the same as per direction of site engineer/ EIC complete in all respect including labour , tools tackles , consumable etc
Taking the Hose Pipe for Hydrotesting and keeping it back in position after drying /rolling etc and fiiling of format as given by EIC/SE
COMPOSITE ITEMS
Taking delivery and refilling the extinguishers of various sizes /capabilities with dry or ABC chemical powder, CO2 gas, Clean Agent/Oxygen/Air, foam compound etc updating the data & identification tags, recording the status of checking in history register etc as per ISI standard and replacing the same as directed by Engineer-in-Charge (The rates are inclusive of all Taxes). (The CO2/N2 gas/ Clean Agent/Oxygen/Air cylinder may to be taken out and delivered back within 10 days after re-filling /repairing. However Fire extinguishers CO2 and N2 are to be supplied /Kept temporary in place of each fire extinguisher for which taking out for re-filling /repairing is required).
Supply and Replenishment of Dry Chemical Powder as relevant IS code
Refilling of CO2 gas in cartridge for using in DCP extinguisher including all labour,transportation etc. Complete as per specification and direction of EIC/Site engineer (CO2 Cartridge of 200 gms)
Refilling of high pressure CO2 Extinguisher (Capacity 2.0 Kg) through CCE approvedparty and charging upto required pressure including taking deliveryof the cylinder from the station and returning the same inclusive of alllabour material, transportation and all.
Refilling of high pressure CO2Extinguisher (Capacity 4.5 Kg) through CCE approvedparty and harging upto required pressure including taking deliveryof the cylinder from the station and returning the same inclusive of alllabour material, transportation and all
Refilling of high pressure CO2 Extinguisher (Capacity 6.8 Kg/9.0 Kg) through CCE approvedparty and charging upto required pressure including taking deliveryof the cylinder from the station and returning the same inclusive of alllabour material, transportation and all.
Refilling of Clean Agent Fire Extinguisher of capacity 2Kg/4Kg/6Kg by Hexafluoropropane ((HFC 227ea) Note: Cylinder refilling process report must be certified/ inspected by an IOCL nominated TPI agency. This rates includes Packing and transportation charges (To & Fro). Packing of cylinders with all required accessories for refilling from IOCL Bathinda Installation and packing of refilled cylinders from filling station are to be done in such way that cylinders must not be damaged or integrity of cylinders must not be weakened while transporting between both locations. To and From charges or freight charges are for transporation of cylinders & other required accessories between IOCL Bathinda Ins tallation and Filling station.
Oxygen filling in cylinders of Resuciator Apparatus
Refilling of breathing apparatus set cylinder with dry compressed air up to a pressure of 200/300 bar as per direction of EIC,inclusive of transportation handling charges,hydrotesting complete in all respect
Hydraulic testing of Co2 Cylinders of sizes 2.0 Kg/4.5 Kg/6.8Kg/Breathing Apparatus as per relevant standards inclusive of all taxes.
Hydraulic testing of DCP Cylinders 10 Kg as per relevant standards.
Hydraulic testing of Clean Agent Cylinders ( 2 to 4.5 Kg/Cm2) as per relevant standards.
Refilling & Hydraulic testing of 25/45/50/75 Kg DCP cylinders as per relevant standards.
Supply and replacing the spares /assembles etc of the Fire Fighting equipments system for all sizes /Capacities as per ISI standard and approved make with all labours ,materials, ,tools and tackles carriages , with all taxes duties etc .complete
Supply and fixing PVC Discharge Pipes for 10 Kg DCP Extinguishers
Supply and fixing Cast Iron Wheel for Hydrants
Supply and fixing Hydrants sheet washer/Rubber including fitting at site
Supply and fixing Hydrants coupling washer
Supply and fixing PVC Lock for Extinguishers
Supply & fitting of HDPE discharge horn for 2.0/4.5 / 6.8Kg capacity CO2 extinguishers with fittingsas per direction of EIC.
Supply and fitting of CO2 extinguisher Safety pin assembly
Supply & fitting of Discharge Pipe with Horn for all type of CO2 Exitinguisher 2.0-4.5Kg
Supply & Fitting of DCP extinguisher cap washer for 10 Kg DCP Extinguisher as per direction of EIC.
Supply and Replacement DCP main Cap (gun metal)
Supply and Replacement Squeezing grip(Plastic)
Supply and Replacement of fire box glass (front)
Supply and Replacement of Key Box Glass
Supply and fixing Hydrant Blind Cap with chain(Rubber)
Supply & fixing Rubber tube of pick up tube of FB5X with strainer
Supply & fixing PVC pick up pipe for foam cum water monitor with strainer of 4 M lengh as per sample
Supply and Replacement CO2 Safety valves 155kgf/cm2
Supply and Replacement DCP Plunger Pin with Spring
Supply and Replacement DCP Plunger top
Supply & Replacemnt of 200 gm CO2 cartridges. S&R of new CO2 cartridges for using in DCP extinguishers including all labour, transportation etc.. complete as per specification and direction of EIC/Site-Engineer. (CO2 Cartridge of 200 gms)
Supply & fitting of clamps for hanging 2Kg / 4.5Kg CO2 extinguisher on wall including labour charges, tools tackles & consumables complete in all respect as per direction of EIC/SE.
Supply & Fixing of Hose box key
Supply & Fixing of "F" key (8mm) as per instruction of EIC/SE.
Supply & Fixing of "F" key (12mm) as per instruction of EIC/SE
Supply & Fixing of "F" key (16,,mm) as per instruction of EIC/SE
Supply & Fixing Sand buckets with covers
Supply & Fixing winds socks only
Supply & fixing of small hammers with chains for Hose boxes.
Painting Works: Supply and painting with two coats synthetic enamel paint(Asian Paint)Fire paint including scrapping cleaning ,one coat of red oxide paint if required etc as per ISI standards and approved make with all labors , materials, carriages, all taxes etc including letter writing identification mark etc complete:
Spray/ Brush painting of fire boxes including stand with 2 coats Luminous yellow Paint and one coat of red oxide (Primer)
Spray/ Brush Painting and Marking of fire Bucket Stand with four Buckets, canopy with atleast two coat of luminour paint and one coat of red oxide etc including nomenclature/stickers
Spray Painting and Marking of Fire Extinguisher including two coat of luminous enemal paint and one coat of red oxide (Primer) of all sizes including nomenclature/stickers.
Spray/brush painting of Foam/water monitors/ Double hydrant valves along with its stand post including letter/number writing.
Spray/ Brush Painting of Fire Siren including letter/number writing.
Removing old damaged wire mesh in foam pourer outlet and replacing with new one (approx size 1.2'X1.2') as directed by EIC including supply of GI coated mesh, tools tackles all complete.
"Writing of slogans (in Hindi, English,Oriya, Punjabi) at all heights with approved paints and shade as per the direction of EIC, date changing on walls, numbering on hydrant valve ,post,direction marking etc as per instructions alongwith all tools, tackles, material etc. The rate covers back ground painting (application of 1 coat primer and 2 coat paint on the board/wall before writing)
Supplying, fabricating and fixing M.S structure steel work made of joints, tubes, pipes, channels, angles, plates, flats, bars etc for struts, chain link fencing as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coat of epoxy paint #EPILUX 155 High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer#s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor, plates, bolts, threading, nuts, washers, sleeves etc and necessary lettering of approved pattern on main gate, signboards etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specification and direction of Site Engineer. (Excluding the cost of concrete work)
"Supply and installation of display board including ACP sheet/Sun Board, Digital Eco-solvent Venyl printing with lamination and pasting with all tool, tackle material as per direction of EIC/SE.
Supply and pasting of radium sticker of required size as per direction of EIC/SE
Supply & pasting of Digital Eco-solvent Venyl printing with lamination in ACP/ Sun board with all tool, tackle material as per direction of EIC/SE.
Supply and application of one coat of Epoxy zinc rich primer to a DFT of 50 microns followed by two coats of epoxy high build finish paint to adry film thickness of 100 microns per coat. Fire Red shade for firewater lines and Canary Yellow shade for foam pourer lines. Total DFTshall be in the range of 250 microns. foam pourer pipings, totalsprinkler system, exterior pipings, sprinkler lines, etc. as per site engineer/EIC
BOL-BOM CONSTRUCTION
CLEANKO TECHNOLOGIES
Krishna Industrial Security And Fire Services
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .