Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
4 Jun 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIJAY PRAKASH JARWAL DGM C&M
Power Grid Corporation of India Limited Rajasthan Projects Office, 4th Floor, REIL House, Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
Construction of Transit Camp / Field Hostel at 765/400 kV Dausa New Substation
NR1/T/W-CIVIL/DOM/I00/25/05161
Open
Civil - All
Works
DAUSA RAJASTHAN
AS PER QR
₹12,500
₹5 L
6 May 2025
6 May 2025
6 Jun 2025
6 May 2025
4 Jun 2025
6 May 2025
Name of Package Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Tender Enquiry Ref No.: NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409
1 Fill up only green shaded cells in Sch-2,3,4,5,6 and Bid Form 2nd Envelope.
2 All the cells in Sch-7, Sch-1 and Sch-1 After Discount are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not drag any cell value to fill down cells to it.
(vii) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder. Do not leave this cell blank.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 to Sch-6 :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-2B After Discount.
● Fill up names & Designation of the representatives of bidder.
● Fill up additional information as required.
Happy Bidding !
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Address of Bidder
Name of other Partner …….. …….. …….. …….. …….. ……..
Address of other Partner …….. …….. …….. …….. …….. ……..
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 2
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
Rajasthan Projects Office, Multipackage Discount #REF!
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR 2023 Description Unit Quantity SAC / HSN Code SAC CODE Rate of GST applicable (in %) GST RATE Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
I CIVIL Scheduled Items (I)
1 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.:All kinds of soil CUM 871.714 120000345 18% Included 0.18
2 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.: All kinds of soil. CUM 63.448 120000349 18% Included 0.18
3 2.10.1.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc, not exceeding 80 mm dia. metre M 475.00 120000353 18% Included 0.18
4 2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia M 75.000 120000354 18% Included 0.18
5 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. CUM 2214.131 120000391 18% Included 0.18
6 2.34.1 Supplying chemical emulsion in sealed containers including delivery as specified.: Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Liter 250.000 120000407 18% Included 0.18
7 2.35.2.1 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration M 60.000 120000409 18% Included 0.18
8 2.35.3.1 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration sq.m 233.245 120000410 18% Included 0.18
9 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) CUM 56.422 120000437 18% Included 0.18
10 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) cum 122.184 120000442 18% Included 0.18
11 4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns sq.m 385.300 120000456 18% Included 0.18
12 4.12 Extra for providing and mixing water proofing material in cement concrete per 50kg work in doses by weight of cement as per manufacturer's specification. per 50kg cement 258.778 120000472 18% Included 0.18
13 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil sq.m 31.859 120000473 18% Included 0.18
14 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. sq.m 60.000 120000477 18% Included 0.18
15 5.33.1.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).:All works upto plinth level CUM 216.910 120003380 18% Included 0.18
16 5.33.2.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).:All works above plinth level upto floor V level CUM 183.565 120003382 18% Included 0.18
17 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. Quintal 160.190 120000568 18% Included 0.18
18 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete SQ.M 128.840 120000499 18% Included 0.18
19 5.9.2 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. SQ.M 400.560 120000500 18% Included 0.18
20 5.9.3 Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform SQ.M 664.550 120000501 18% Included 0.18
21 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers SQ.M 1200.080 120000503 18% Included 0.18
22 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts SQ.M 713.450 120000504 18% Included 0.18
23 5.9.7 Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases SQ.M 23.420 120000505 18% Included 0.18
24 5.9.14 Centering and shuttering including strutting, propping etc. and removal of form for : Extra for shuttering in circular work (20% of respective centering and shuttering items) SQ.M 7.350 120000512 18% Included 0.18
25 5.9.15 Centering and shuttering including strutting, propping etc. and removal of form for :Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like SQm. 15.340 120000513 18% Included 0.18
26 5.9.16.1 Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide M 357.120 120000514 18% Included 0.18
27 5.9.19 Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges SQ.M 19.670 120000518 18% Included 0.18
28 5.18.1 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 5.18.1 50 mm thick Sqm. 40.440 120000532 18% Included 0.18
29 M5.22.6/M 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level kg 49811.789 120000543 18% Included 0.18
30 6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) CUM 51.726 120000601 18% Included 0.18
31 6.2.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) CUM 27.224 120000603 18% Included 0.18
32 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) CUM 168.995 120000607 18% Included 0.18
33 6.12.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : sq.m 44.000 120000616 18% Included 0.18
34 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.:Cement mortar 1:4 (1 cement :4 coarse sand) sq.m 377.260 120000618 18% Included 0.18
35 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry sq.m 374.150 120000620 18% Included 0.18
36 8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity,counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.:Granite of any colour and shade: Area of slab upto 0.50 sqm SQ.M 50.990 120000738 18% Included 0.18
37 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.:Granite work M 70.050 120000741 18% Included 0.18
38 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sq.m 313.760 120003230 18% Included 0.18
39 8.5 Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete EACH 1.000 120000743 18% Included 0.18
40 9.7.5.1 Particle Board 12 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked Sqm. 50.810 120000779 18% Included 0.18
41 9.47.1 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracket: 20 mm dia (heavy type) meter 63.810 120000864 18% Included 0.18
42 9.96.2 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm EACH 2.000 120000988 18% Included 0.18
43 9.97.1 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm EACH 4.000 120000989 18% Included 0.18
44 9.97.2 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm EACH 2.000 120000990 18% Included 0.18
45 9.100.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm EACH 24.000 120000996 18% Included 0.18
46 9.101.2 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.:Twin rubber stopper EACH 3.000 120001000 18% Included 0.18
47 9.115 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineerin- charge. One set 47.000 120001021 18% Included 0.18
48 9.129 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge sq.m 216.730 120001043 18% Included 0.18
49 9.147C.2 (DSR 2021) Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm) sq.m 67.110 130000797 18% Included 0.18
50 9.147D.4 (DSR 2021) Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). sq.m 32.270 130000797 18% Included 0.18
51 9.147D.5 (DSR 2021) Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) SQ.M 5.280 170001892 18% Included 0.18
52 9.147A.1 (DSR 2021) Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) SQ.M 5.010 120003140 18% Included 0.18
53 9.156.1 Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 Sqm. 41.700 120001105 18% Included 0.18
54 10.2 Structural Steel work riveted, bolted or welded in built up sections, trusses & framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Kg 4364.267 120001116 18% Included 0.18
55 10.5.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.:Using M.S. angels 40x40x6 mm for diagonal braces sq.m 5.600 120001119 18% Included 0.18
56 10.17 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. EACH 31.000 120001146 18% Included 0.18
57 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.:In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works kg 1724.976 120001153 18% Included 0.18
58 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). kg 481.898 120001162 18% Included 0.18
59 11.23.5 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble SQ.M 32.970 120001227 18% Included 0.18
60 11.24 Extra for pre finished nosing to treads of steps of marble stone. M 49.000 120001229 18% Included 0.18
61 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. sq.m 32.970 120001230 18% Included 0.18
62 11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,complete. sq.m 149.840 120001246 18% Included 0.18
63 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.:Size of Tile 600x600 mm SQ.M 463.070 120001251 18% Included 0.18
64 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete: Size of Tile 600x600 mm SQ.M 73.800 120001259 18% Included 0.18
65 12.1.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 1.00 mm thick with zinc coating not less than 275 gm/m² Sqm. 172.750 120001280 18% Included 0.18
66 12.21.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 deep chase M 120.100 120001318 18% Included 0.18
67 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Each 18.000 120001319 18% Included 0.18
68 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:110 mm diameter M 59.750 120001351 18% Included 0.18
69 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.:Bend 87.5°: 110 mm bend EACH 8.000 120001361 18% Included 0.18
70 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.:110mm EACH 55.000 120001365 18% Included 0.18
71 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. EACH 6.000 120001366 18% Included 0.18
72 13.1.2 12mm cement plaster of mix: 1:6 (1 cement: 6 fine sand) Sq.m 990.830 120001400 18% Included 0.18
73 13.2.2 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) Sq.m 547.840 120001402 18% Included 0.18
74 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). sqm Sqm. 1409.600 120001418 18% Included 0.18
75 13.16.1 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) sq.m 1140.570 120001423 18% Included 0.18
76 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to given an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. Sq.m 55.200 120001491 18% Included 0.18
77 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. sq.m 3365.120 120001511 18% Included 0.18
78 13.41.1 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.:Two coats sq.m 1954.320 120001461 18% Included 0.18
79 13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.: Two Coats sq.m 1409.600 120001515 18% Included 0.18
80 13.85.3 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.:With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre sq.m 3387.270 120001522 18% Included 0.18
81 17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid EACH 6.000 120001870 18% Included 0.18
82 17.3.1 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid EACH 7.000 120001872 18% Included 0.18
83 17.7.4 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer EACH 13.000 120001889 18% Included 0.18
84 17.7.3 Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, Kingston/ Gem/ Techno/ Parko, 32mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever required: White Vitreous China: Flat back wash basin size 550x400mm with a single 15mm C.P. brass pillar tap. each 1.000 120001888 18% Included 0.18
85 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings EACH 1.000 120001897 18% Included 0.18
86 17.10.1.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board:510x1040 mm bowl depth 250 mm EACH 1.000 120001899 18% Included 0.18
87 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. EACH 13.000 120003124 18% Included 0.18
88 17.28.1.1 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete: Semi rigid pipe: 32mm dia each 1.000 120001935 18% Included 0.18
89 17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap. each 39.000 120001939 18% Included 0.18
90 17.32.2 Providing and fixing mirror of superior quality thickness of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape 453x357mm each 1.000 120001943 18% Included 0.18
91 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. EACH 13.000 120001946 18% Included 0.18
92 17.34.1 Providing and fixing toilet paper holder :C.P. brass EACH 13.000 120001947 18% Included 0.18
93 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. EACH 13.000 120001941 18% Included 0.18
94 18.7.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.:Internal work - Exposed on wall:25 mm nominal outer dia Pipes m 43.510 120002104 18% Included 0.18
95 18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 20 mm nominal outer dia Pipes Meter 120.060 120002109 18% Included 0.18
96 18.12.3 Providing and fixing G.I. Pipes complete with G.I. fittings including trenching and refilling etc. (external work): 25mm dia. nominal bore m 174.550 120002132 18% Included 0.18
97 18.12.6 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.:External work: 50mm dia nminal bore M 113.000 120002135 18% Included 0.18
98 18.12.8 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work: 80 mm dia nominal bore Meter 80.000 120002137 18% Included 0.18
99 18.13.1 Making connection of G.I. distribution branch with G.I. main of sizes by providing and fixing tee including cutting and threading the pipe etc. complete: 25 to 40mm dia. nominal bore each 2.000 120002138 18% Included 0.18
100 18.13.2 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore Each 4.000 120002139 18% Included 0.18
101 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25mm nominal bore each 12.000 120002145 18% Included 0.18
102 18.17.4 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore Each 3.000 120002148 18% Included 0.18
103 18.19.4.1 Providing and fixing gun metal non- return valve of approved quality (screwed end) :50 mm nominal bore:Horizontal Each 3.000 120002160 18% Included 0.18
104 18.19.6.1 Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm nominal bore: Horizontal Each 1.000 120002164 18% Included 0.18
105 18.21.2.1 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length:15 mm nominal bore Each 61.000 120002171 18% Included 0.18
106 18.32.1 Constructing masonry chamber 30x30x50cm inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4coarse sand) for stop cock, with C.I. surface box 100x100x75mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 course sand: 4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design: With F.P.S. bricks. each 2.000 120002228 18% Included 0.18
107 18.34.1 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1.000 120002230 18% Included 0.18
108 18.31.1.2 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) ::100 mm diameter:Class II Each 1.000 120002217 18% Included 0.18
109 18.38.6 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :50 mm diameter pipe Meter 209.000 120002239 18% Included 0.18
110 18.40.8 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :80 mm diameter pipe Meter 80.000 120002253 18% Included 0.18
111 18.46.3 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore each 20.000 120002272 18% Included 0.18
112 18.46.6 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50 mm nominal bore Each 10.000 120002275 18% Included 0.18
113 18.46.8 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 80 mm nominal bore Each 2.000 120002277 18% Included 0.18
114 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank(TRIPPLE LAYER). per litre 7500.000 120002286 18% Included 0.18
115 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.:15 mm nominal bore Each 5.000 120002289 18% Included 0.18
116 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931:15mm nominal bore(Hindware Addons Economy Model Angular Stop Cock (Chrome) Each 63.000 120002291 18% Included 0.18
117 19.6.1 Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : m 10.000 120002652 18% Included 0.18
118 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 9.000 120002665 18% Included 0.18
119 19.7.2.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 2.000 120002667 18% Included 0.18
120 19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 1.000 120002731 18% Included 0.18
121 21.1.1.1. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) kg 198.325 120002790 18% Included 0.18
122 21.1.2.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) kg 63.485 120002793 18% Included 0.18
123 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness SQ.M 33.620 120002798 18% Included 0.18
124 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width EACH 104.950 120002807 18% Included 0.18
125 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). sq.m 7.440 120002828 18% Included 0.18
126 22.3 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). SQm. 257.420 120002831 18% Included 0.18
127 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) SQ.M 59.820 120002835 18% Included 0.18
128 22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. SQ.M 557.990 120002837 18% Included 0.18
129 26.22.1 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqmincluding both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length1200 mm and secondaryintermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed on periphey wall / partition withthe help of plastic rawl plugs at 450mm center to center and 40 mmlong dry wall S.S screws. The workshall be carried out as perspecifications, drawing and as per directionsof the Engineer-in-Charge:With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles Sqm 11.514 120002990 18% Included 0.18
130 7427 Supply of Water stops Serrated with central bulb (225 mm wide, 8-11 mm thick) m 151.960 120002832 18% Included 0.18
CIVIL Non Scheduled Items (II) 0
1 NS1 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(Mode Hindware F160039CP Overhead Shower ) Each 9.000 170001523 18% Included 0.18
2 NS2 Providing and fixing C.P. brass TWO BAY BIB cock WITH HEALTH FAUCET (Hindware F330004CP Bib Cock 2 in 1 (Contessa Plus) With Chrome Finish and Hindware Soft ABS Plastic Toilet Hand Spray Complete Set (Multicolour) Each 12.000 17002103 18% Included 0.18
3 NS3 Providing and fixing C.P. SINK cock MODEL Hindware F330024CP Sink Cock with Swivel Casted Spout (Wall Mounted) (Contessa Plus) with Chrome Finish Each 2.000 170001410 18% Included 0.18
4 NS4 Providing and fixing uPVC SWR pipe (Type B) as per IS13592 :75mm dia pipe m 127.810 170001556 18% Included 0.18
5 NS5 Providing and fixing uPVC SWR pipe (Type B) as per IS13592 :110mm dia pipe m 173.530 170001556 18% Included 0.18
6 NS6 Providing and fixing bend of required degree with access door complete :100mmPVC -U SWR AS PER IS 14735 Each 24.000 170001811 18% Included 0.18
7 NS7 Providing and fixing bend of required degree with access door complete :75mmPVC -U SWR AS PER IS 14735 Each 13.000 170001811 18% Included 0.18
8 NS8 Providing and fixing plain bend of required degree/heel rest bend :100 mmPVC -U SWR AS PER IS 14735 Each 15.000 170002368 18% Included 0.18
9 NS9 Providing and fixing plain bend of required degree/heel rest bend :75 mmPVC -U SWR AS PER IS 14735 Each 48.000 170002369 18% Included 0.18
10 NS10 Providing and fixing terminal guard 100mm PVC -U SWR AS PER IS 14735 Each 10.000 170002372 18% Included 0.18
11 NS11 Providing and fixing PVC Clips for SWR PIPES :100MM Each 42.000 170002375 18% Included 0.18
12 NS12 Providing and fixing PVC Clips for SWR PIPES :75MM Each 15.000 170002376 18% Included 0.18
13 NS13 P/F OF STAINLESS STEEL H HANDLE FOR FRAMELESS DOOR (32MMX457MM) SS202 grade or better set 2.000 170001501 18% Included 0.18
14 NS14 Provoding LOCK FOR frameless door Ozone OPL-1 Steel Corner Patch Lock with Strike Plate (Silver) or equivalent Nos 2.000 170001772 18% Included 0.18
15 NS15 Providing and fixing C.I Manhole Cover of size 455X610mm Nos. 6.000 170000804 18% Included 0.18
16 NS16 Supply and fillimg of Brickbats in sunken portion of toilets Cum 11.203 170000779 18% Included 0.18
17 NS17 Supply and fixing of Wall Mixer in toilet of make : Jaguar,Hindware ,cera or equivalent as per direction of engineer -in-charge Nos. 9.000 170001822 18% Included 0.18
18 NS18 Providing and fixing CP Brass soap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Each 13.000 170000791 18% Included 0.18
19 NS19 Providing and fixing CP brass towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. each 14.000 170000789 18% Included 0.18
20 NS20 Providing and fixing CP Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. each 13.000 170000854 18% Included 0.18
ELECTRICAL Scheduled Items (III) 0
1 1.8.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required. Group A POINT 42.000 130000021 18% Included 0.18
2 1.9 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. POINT 1.000 130000024 18% Included 0.18
3 1.10.3 Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm FR LS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required.:Group C Point 212.000 130000027 18% Included 0.18
4 1.11 Wiring for twin control light point with 1.5 sq mm FR LS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with 2-way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Point 13.000 130000028 18% Included 0.18
5 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire M 452.600 130000031 18% Included 0.18
6 1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required..:2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire METER 1169.720 130000032 18% Included 0.18
7 1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire M 576.770 130000033 18% Included 0.18
8 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.:25MM Metre 1009.880 130000093 18% Included 0.18
9 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:5/6 A switch EACH 131.000 130000121 18% Included 0.18
10 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:3 pin 5/6 A socket outlet EACH 130.000 130000124 18% Included 0.18
11 1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:Telephone socket outlet EACH 11.000 130000126 18% Included 0.18
12 1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:TV antena socket outlet EACH 11.000 130000127 18% Included 0.18
13 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. EACH 30.000 130000129 18% Included 0.18
14 1.27.2 S/F modular boxes, base & cover plate: Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required.:3 Module ( 100 mm x 75 mm) Each 60.000 130000132 18% Included 0.18
15 1.27.4 S/F modular boxes, base & cover plate: Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required.:6 Module ( 200 mm x 75 mm) Each 84.000 130000134 18% Included 0.18
16 1.27.6 Supply and fixing of 12 Module (200mmX150mm) GI Box Each 18.000 130000136 18% Included 0.18
17 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A Modular switch, connections etc. as required Each 238.000 130000145 18% Included 0.18
18 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch, connections etc. as required Each 87.000 130000146 18% Included 0.18
19 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types/LED battens, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 231.000 130000155 18% Included 0.18
20 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 29.000 130000159 18% Included 0.18
21 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.:Upto 450 mm sweep Each 11.000 130000164 18% Included 0.18
22 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 11.000 130000166 18% Included 0.18
23 1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.:2 Pair METER 160.000 130000084 18% Included 0.18
24 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid core copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required. Metre 193.500 130000086 18% Included 0.18
25 2.4.1 Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (HAvells/L&T/Schneider/Equivalent makes): 4 way (4 + 12), Double door, horizontal TPN DB. Each 4.000 130000196 18% Included 0.18
26 2.5.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.):4 way (4 + 12), Double door EACH 2.000 130000202 18% Included 0.18
27 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with onnections, testing and commissioning etc. as required.: Single pole EACH 75.000 130000233 18% Included 0.18
28 2.10.5 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with Connections, testing and commissioning etc. as required.:Triple pole and neutral EACH 7.000 130000237 18% Included 0.18
29 2.14.3 Supply and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A Each 4.000 130000246 18% Included 0.18
30 2.13.1 Supply and fixing following rating, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required – 40A Each 8.000 130000241 18% Included 0.18
31 2.13.2 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required : 63A Each 6.000 130000242 18% Included 0.18
32 2.18 S/F 20A SPN MCB industrial socket outlet:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP, MCB, in sheet steel inclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 17.000 130000252 18% Included 0.18
33 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. EACH 5.000 130000255 18% Included 0.18
34 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Each 2.000 130000415 18% Included 0.18
35 5.4 Earthing with G.I earth plate 600 mm X 600mmX6mm thick including accessories and providing mansonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc . With charcorl /cock and salt as required. . Each 2.000 130000417 18% Included 0.18
36 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. SET 2.000 130000419 18% Included 0.18
37 5.9 Supply and laying 25x5 copper strip at 0.50m below ground as strip earth electrode, including connection, / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nuts and bolts and spring washer spaced at 50mm) Meter 35.750 130000422 18% Included 0.18
38 5.10 Supplying and fixing25x5mmG.I. strip in 40mm dia G.i. pipe from earth electrod all complete as per specification and direction of E/I. Meter 9.000 130000423 18% Included 0.18
39 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. M 37.760 130000428 18% Included 0.18
40 5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing alongwith existing surface /recessed conduit/ submain wiring/ cable as required Mtr 9.000 130000432 18% Included 0.18
41 6.2 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Each 2.000 130000435 18% Included 0.18
42 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required Each 4.000 130000437 18% Included 0.18
43 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) Meter 91.000 130000440 18% Included 0.18
44 6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) Meter 7.900 130000441 18% Included 0.18
45 7.10 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. EACH 20.000 130000482 18% Included 0.18
ELECTRICAL Non Scheduled Items (IV) 0
1 NS-1 Supply, installation, testing and commissioning of LED tubelight 20W (Philips Astra Line 20-Watt LED Battern (Cool Day Light or equivalent)) complete with all accessories as required - of POWERGRID approved makes Each 17.000 100005136 18% Included 0.18
2 NS-2 Supply, installation, testing and commissioning of LED tubelight 11W (PHILIPS 31167 11W Adjustable Mirror Light) or equivalent) complete with all accessories as required - of POWERGRID approved makes Each 12.000 100005136 18% Included 0.18
3 NS-3 Supply, installation, testing and commissioning of bulk head fitting Complete with all accessories 10 Watt LED lamp as required ; make as per TS Each 4.000 170001617 18% Included 0.18
4 NS-4 Supplying fitting and fixing 250 mm dia exhaust fan with plastic body and blade, self closing louvers in the fan, to provide off mode protection against birds etc. inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. (WITH CEILING ROSE) Each 13.000 100001077 18% Included 0.18
5 NS-5 Supplying fitting and fixing 1400 mm sweep ceilling fan high quality & high speed, heavy duty ,(approved make) inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. Crompton/CGL/Bajaj/ Havells/ Usha/Philips makes Each 18.000 100001076 18% Included 0.18
6 NS-6 Supplying fitting and fixing 1200 mm sweep ceilling fan high quality & high speed, heavy duty ,(approved make) inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. Crompton/CGL/BAjaj/Havells/Usha/Philips makes Each 11.000 100005138 18% Included 0.18
7 NS-7 2mm CRCA Indoor Panel alongwith 1 No. 250A MCCB 4P 36kA with Extended Handle & Spreader for Incoming and 3 Nos. 125A MCCB 4P 36kA with Extended Handle,Spreader forr outgoing consisting of suitable rating of Alu Busbar. This also includes supply and installation of 3-phase energy meter EAch 1.000 100005706 18% Included 0.18
8 NS-8 Supply & Installation of Geyser of minimum 3star and above with 15llts capacity of approved make by engineer-in-charge each 13.000 170001230 18% Included 0.18
9 NS-9 Supply & Installation of 1500 m³/hr Auto-Clean curved glass Kitchen Chimney of approved make as per the Engineer-in-charge each 1.000 100005418 18% Included 0.18
10 NS-10 Supplying, installation, testing and commissioning of following sizes and core PVC /XLPE insulated PVC sheathed ,heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts (Powergrid Approved make cables) 70sq. mm , 3.5 core Meter 100.000 100001132 18% Included 0.18
11 NS-11 Supplying, installation, testing and commissioning of following sizes and core PVC /XLPE insulated PVC sheathed ,heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts (Powergrid Approved make cables) 4Cx16 Sq-mm Meter 1000.000 100001134 18% Included 0.18
12 NS-12 Supply, Installation, testing and commissioning of 1.5 Ton Invertor model All weather (Hot & cold) Split AC(copper condensor ) with minimum 3 star rating and above. Scope of work including installation of indoor and outdoor units, laying of AC pipes in wall/PVC conduit upto outdoor unit and drain pipe. Fixing of Outdoor unit with suitable support fixure/frame etc all in complete respect as per directions of Engineer In-Charge. Each 17.000 100005716 18% Included 0.18
13 NS-13 Supply and laying/installation of Additional AC duct pipes and drain pipe in wall /Recessed PVC conduit as per the instructions of Engineer-in-charge Ft 223.500 170002451 18% Included 0.18
14 NS-14 Supply and installation of decorative wall mounted LED Night lamp fitting with lamp Philips make Philips 31434 Muziris Laminar Wall Lamp or equivalant as approved by the Engineer-in-charge Each 13.000 150000878 18% Included 0.18
15 NS-15 Supply installation, testing and commissioning of Lighting Fixture: Type SL-D1 as per TS (30W) Post Top Lighting Fixture (With all required accessories for fixing, termination and earthing) as per TS (Phillips, Bajaj, Havells, Insta, equivalent) Each 15.000 100004851 18% Included 0.18
16 NS-16 Supply installation, testing and commissioning of Supply of D1 Pole 4 Mtr (With all required accessories for fixing and earthing) as per TS Each 15.000 100004935 18% Included 0.18
17 NS-17 Supply Installation testing and commissioning of Sub Lighting Panel Incomers: 4 pole 32A TPN MCB suitable for 415V AC supply Outgoings: 8 nos. terminal blocks suitable for cable upto 16 sq. mm cable. Mounting: Suitable for Outdoor applications with Loop in and Loop out facility. Each 2.000 100001138 18% Included 0.18
18 NS-18 Supply, installation, testing and commissioning of 1.1kV 2C x 6 Sq-mm PVC cable Mtrs 200.000 100001138 18% Included 0.18
19 NS-19 Supply of 20w LED batten complete with all accessories of make philips/havells/syska or equivalent Nos 22.000 100004480 18% Included 0.18
20 NS-20 Supply 380-450 mm, 1400 RPM exhaust fans complete with brackets,blades and all other accessories and fittings,confirming to relevant IS and suitable for operation on 230 V single phase AC supply Nos 3.000 100001077 18% Included 0.18
21 NS-21 SUPPLY AND INSTALLATION of 100Watt(waterproof) LED flood light of make Philps/Bajaj or equivalent as approved by Engg in charge Nos 6.000 150000880 18% Included 0.18
22 NS-22 Supply & installation of 5 HP, 3 phase open well submercible pumpset with minimum head of 20 m and above suction 80/65mm & Delivery 65/50 mm of Kirloskar/CRI/ any ISI make as approved by Engineer-in-charge EACH 2.000 170001851 18% Included 0.18
23 NS-23 Supply and installation of DOL starter with overload protection rating 11-18A suitable for operation of 5HP, 3ph monoblock pumpset complete EACH 2.000 100006120 18% Included 0.18
24 NS-24 Supply of 10/12W water proof LED cool white underwater light fitting suitable for installation on wall/ceiling of underground water sump/tank EACH 2.000 100006422 18% Included 0.18
25 NS-25 Supply and fixing of 200 mm dia circular LED Lights in ceiling make :philips,anchor,Crompton etc Nos. 156.000 170001222 18% Included 0.18
Total charges (Excluding Tax) 0.00
Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 3
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
Rajasthan Projects Office, Multipackage Discount #REF!
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR Ref Description Unit Quantity SAC Code WhetherHSN in column ‘5’ is confirmed. If not indicate applicable theHSNC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
13.1 Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. each 3.00 998739 18% Included 0.18
13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. set 3.00 998739 18% Included 0.18
S.H.-III Cable & Pipes 0
14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 0
14.16.1 63 mm dia (OD-63 mm & ID-51 mm nominal) Mtr 75.00 998739 18% Included 0.18
14.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) Mtr 20.00 998739 18% Included 0.18
14.16.5 200 mm dia (OD-200 mm & ID-175 mm nominal) Mtr 10.00 998739 18% Included 0.18
CIVIL DSR 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand) RCC top slab with 1:2:4 mix ( 1 cement :2 coarse sand:4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand:8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : coarse sand :4 graaded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per stnadard design: Inside size 30x30 cm and and 45 cm deep including C.I. cover with frame (light duty) 500 mm internal diameter , total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) With common burnt clay FPS ( non modular) bricks of class designation 7.5 each 10.00 995424 18% Included 0.18
10.1 Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. Each 2.00 18% Included 0.18
9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 0
9.1.25 2x6 sq. mm Each 156.00 998739 18% Included 0.18
9.1.32 4x10 sq. mm Each 2.00 998739 18% Included 0.18
9.1.20 3.5x25 sq.mm (28 mm) Each 8.00 998739 18% Included 0.18
9.1.33 4x16 sq. mm Each 2.00 998739 18% Included 0.18
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 0
7.1.1 Upto 35 sq. mm Mtr 1847.00 998739 18% Included 0.18
7.1.2 Above 35 sq. mm and up to 95 sq. mm Mtr 110.00 998739 18% Included 0.18
7.1.4 Above 185 sq. mm and up to 400 sq. mm Mtr 140.00 998739 18% Included 0.18
7.2 Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation inclucing excavation, sand cushioning, protective covering and refilling the trench etc. as required. 0
7.2.1 Up to 35 sq. mm Mtr 173.00 998739 18% Included 0.18
7.5 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. 0
7.5.1 Up to 35 sq. mm Mtr 195.00 998739 18% Included 0.18
7.5.2 Above 35 sq. mm and up to 95 sq. mm Mtr 5.00 998739 18% Included 0.18
7.5.4 Above 185 sq. mm and up to 400 sq. mm Mtr 5.00 998739 18% Included 0.18
7.6 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size in the existing masonry open duct as required. 0
7.6.1 Upto 35 sq. mm Mtr 95 998739 18% Included 0.18
7.6.2 Above 35 sq. mm and up to 95 sq. mm Mtr 5 998739 18% Included 0.18
7.6.4 Above 185 sq. mm and up to 400 sq. mm Mtr 5 998739 18% Included 0.18
7.7 Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on wall surface as requred. 0
7.7.1 Upto 35 Sq. mm (clamped with 1 mm thick saddle) Metre 5.00 998739 18% Included 0.18
8.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 0
8.1.1 Upto 120 sq. mm Mtr 40.00 998739 18% Included 0.18
8.30 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 0
8.3.1 Upto 120 sq. mm Mtr 10.00 998739 18% Included 0.18
S.H.- V Earthing 0
5.20 Earthing with G.I. pipe 4.5 metre long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Each 7.00 998739 18% Included 0.18
5.40 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Sets 12.00 998739 18% Included 0.18
5.60 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. Set 2.00 998739 18% Included 0.18
5.1 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Mtr 10.00 998739 18% Included 0.18
5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. Mtr 50.00 998739 18% Included 0.18
5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I wire in 15 mm dia G.I pipe FRLSom earth electrode including conneciton with G.I thimble excavation and re-filling as required. Mtr 35.00 998739 18% Included 0.18
5.18 Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. Mtr 3800.00 998739 18% Included 0.18
Sub Head I - 11 KV H.T. Out door items :- 0
MR Supply and erection of 152.x152 mm 9 mtr. long H beam steel pole (37.1 kg/meter) in cement concrete foundation 1:3:6 ( 1 cement: 3 coarse sand: graded stone aggregate 40mm nominal size) including excavation aligning, keeping the pole in vertical position, painting with one coat of red oxide (primer), secured with holding clamps nuts and bolts, confirming to relevant ISS etc. as required. each 2.00 998731 18% Included 0.18
MR Supply and fixing of following sizes of Angle/channel/flat iron in the pole structure for mounting of lighting arrestors, A.B. switches, D.O. fuse assembles, Disc insulators, pin and post insulators.P.T. & cable end box etc. complete with G.I. Nuts, bolts, washers making of holes and other required materials painting with one coat of red oxide etc. as required. 1. M.S. channel (100 x 50mm) 2.M.S. angle iron ( 50x50x6mm) 3.M.S. flat iron (80x6mm) for clamps 4.M.S. plate 7mm thick (for mounting of lightning arrestors). Note: Cost of lightning arrestors AB switches etc. not to be included in this item. They are covered under item No. 1.6 and 1.7 kg 400.00 998731 18% Included 0.18
MR Painting of one no. 2 pole structure complete with members including clamps, brackets,nuts,bolts and washers with additional one coat of red oxide (primer) and two coats of aluminium paint of approved make etc. as required. job 1.00 998731 18% Included 0.18
MR Supply and fixing anti climbing device made of G.I. Barbed wire confirming to ISS 278-1960 having 4 points barbs 12.5 kg/100m size wrapped helically with a pitch of 75mm on the existing poles for height 1.5m commencing from 3.5m from ground with suitable clamps at the end as required. each 2.00 998731 18% Included 0.18
MR Supplying, spreading and dressing of 40mm (nominal) graded stone broken from boulders of hard quartz and sand stone upto a depth of 150mm (nominal) in the existing H.T. yard etc. as required. cum 8.00 995428 18% Included 0.18
MR Supplying and erection (one set of three numbers) of 200 Amps.11 KV A.C. supply system H.T. gang operated air break isolating switch assembly (tilting type) with phosphor bronze/tinned copper contacts complete with operating handle of suitable length with square bar handle including pad locking arrangement and other G.I. hardware fittings confirming to relevant I.S. specifications and fixing the same on the existing pole structure on channels and clamps including making connections, testing and commisssioning etc. as required. set 1.00 998736 18% Included 0.18
MR Supplying and erection (one set of three Nos.) of 11 KV dropout fuse unit assembly vertical mounting complete with fuse barrel, fuses and other G.I. Hardware fittings confirming to relevant ISS & fixing the same on the existing pole structure including making of connections, testing and commissioning etc. as required. set 1.00 998736 18% Included 0.18
MR Supply, installation, testing and commissioning of outdoor type transformer of 400 KVA capacity ONAN type with copper winding having a continuous rating of 11 KV/433 V 3 phase 50 Hz. Vector group Dy N 11 having 3x120 sq. mm 11 KV u.g cable on H.V.side and 1 No. 3.5 core 300 sq.mm underground cable on 433 volts side, with all fittings and accesories off load tap changer for - 7.5% to + 7.5% of 2.5 each complete with filtered oil etc.and outdoor foundation plate form complete confirming to section 3 of CPWD General specifications for electrical works (part IV sub-station) 2013. set 1.00 998736 18% Included 0.18
MR Supplying and drawing of ACSR Raccoon conductor of approved make including stringing and making complete with binding at existing insulator jointing jumpering teeing of connections etc. as required. mtr 20.00 995468 18% Included 0.18
Sub Head-II L.T Panel & Feeder Pillar 0
MR Supplying, installation, testing and commissioning of cubicle type LT panel suitable for 415 V, 3 Phase, 4 wire 50 HZ AC supply system fabricated in comparmentalized ( preferable) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick fro gland, plates i/c cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 3000Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bars of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec, bottom base channel of MS section not less than 100 mm x 50 mm x5 mm at the rear with 2 nos. earth stud, solid connectons from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plated in two hald, i/c providing following switch gears:- Incoming:2 Nos. four pole MCCB of fault breaking capacity 50 KA (Ics=Icu up to 433V) , fitted with interlocked door,complete with following accessories for each MCCB. (a) 800A 4P MCCB- 1 no. for normal supply (b) 630A 4P MCCB - 1 no. for DG supply Set 1.00 998736 18% Included 0.18
(a) 800A 4P MCCB- 1 no. for normal supply Price included above 0
(b) 630A 4P MCCB - 1 no. for DG supply 0
© Analog 96 mm square /Digital* type volmeter (0-500V), with selector switch and back up / MCBs- 1 set. 0
(d) Analog 96 mm. square /Digital* type Ammeter (0- 800Amp), with selector switch and one set of 3 nos. CT's of ratio 800 /5A Class I accuracy and 15 VA burden- 1 set . 0
(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker 'ON' indicated light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. 0
(II) Bus Couplers: 0
1 No. 800 Amps 4 Pole MCCB of fault breaking capacity 50 KA (Ics-Icu up to 433 V) complete. 0
(III) Bus Bars: 0
TPN aluminium bus bars of minimum of 1000 Amps capacity with heat shrinkabel coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec. 0
(IV) Interlocking: 0
Electrical throuth advance contacts in MCCBs (incomers & bus coupler) and mechanical ( castel key) interloking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminated any possibility of accidentally approaching two supplies at one bus section. 0
(V) Outgoing: 0
(a) 200A 4 P MCCB 35 KA - 5 nos. 0
(b) 100 A 4 P MCCB - 25 KA - 5 nos. 0
( c) 63A 4P MCCB 25 KA 1 no. 0
Feeder Pillar for compound lights 0
MR Supply, installation, testing and commissioning of cubicle type feeder pillar (out -door type) suitable for 415 V. 3 ph. 4 wire 50 Hz AC Supply system fabricated in compartmentalizer (preferably) design from CRCA sheet steel 2 mm thick for frame work and covers 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 200amps capacity extensible type TPN aluminium alloy bus bars, bottom base channel of MS section not less than 100 mm x 50mmx5 mm thick complete with 2 nos. earth stud the control wiring shall be with 2.5 sq. mm PVCinsulated copper conductor s/c cable complete with cable alloys, cable gland plates in two half i/c providing following switch gears. Set 1 998736 18% Included 0.18
(a) Incomer Prices included above 0
(i) 63 Amp 4P MCCB 25 KA- 1 no 0
(ii) 40 Amps astronomical time switch for automatic switching On & OFF of compound Lights (Auto ON, Auto OFF, Auto modes) with manual over ride facility with 12/24 hrs. display format with suitable battery and indications for relay status i/c programming at site complete as required. 0
(i) 6-15 Amp DP MCB 10 KA - 15 nos. 0
Feeder Pillar for Quarters 0
MR Supply, installation, testing and commissioning of cubicle type feeder pillar (out -door type) suitable for 415 V. 3 ph. 4 wire 50 Hz AC Supply system fabricated in compartmentalizer (preferably) design from CRCA sheet steel 2 mm thick for frame work and covers 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 400amps capacity extensible type TPN aluminium alloy bus bars, bottom base channel of MS section not less than 100 mm x 50mmx5 mm thick complete with 2 nos. earth stud the control wiring shall be with 2.5 sq. mm PVC insulated copper conductor s/c cable complete with cable alloys, cable gland plates in two half i/c providing following switch gears. Set 1 998736 18% Included 0.18
(i) 200A 4P MCCB 35KA-1 no Prices included above 0
(i) 100A 4P MCCB 25 KA- 2 nos. 0
(ii) 63A 4P MCCB 25KA - 6 nos 0
AUTOMATIC POWER FACTOR CORRECTION PANEL 0
MR Design, manufacture, supply, storing, inspection, handling, assembling, installation in correct alignment, position, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 125 KVAR A P F C Panel APP/Mdxl type consisting of, one no. 50 KVAR 2 nos. 25 KVAR and 2 nos. 12.5 KVAR complete with 1 no 8 step APFC relay etc., in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & virmin proof, front operated construction, enclosure class - IP 52, Painting by one coat of red oxide primer with two coats of approved synthetic enamel paint complete with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2,5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 440 Volts, 3 phase 50 Hz, suitable capacitor duty contineous to be used for switching etc., as required. SET 1.00 998736 18% Included 0.18
S.H.-III Cable & Pipes 0
MR Suppy of 3 core 120 sq.mm standard aluminium conductor 11 KV grade XLPE (E) insulated PVC sheathed galvanised flat steel sheet armoured cable conforming to IS 7098 (Pt-II with latest amendment) Mtr 50.00 998739 18% Included 0.18
MR Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required. 0
(i) 3.5x300 sq. mm Mtr 150.00 998739 18% Included 0.18
(ii) 3.5x70 sq. mm Mtr 120.00 998739 18% Included 0.18
(iii) 3.5x35 sq. mm Mtr 500.00 998739 18% Included 0.18
(iv) 3.5x25 sq. mm Mtr 200.00 998739 18% Included 0.18
(vi) 4x16 sq. mm Mtr 60.00 998739 18% Included 0.18
(vii) 4x10 sq. mm Mtr 5.00 998739 18% Included 0.18
(viii) 2x6 sq. mm Mtr 1550.00 998739 18% Included 0.18
MR Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 300 sq. mm Each 2.00 998739 18% Included 0.18
S.H.-IV (Compound Light Fittings) 0
MR Supply, installation, testing and commissioning of 40 watt LED street light fitting IP 66 suitable for installation on 6 mtr high existing pole complete with IP 66 control gear in separate compartment , extruded aluminium painted housing, a toughened glass protector etc., as required (POWERGRID approved make) each 15.00 998739 18% Included 0.18
MR Supply, installation, testing and commissioning of 150 W LED street light fitting IP 66 suitable for installation street light fitting IP 66 suitable for installation on 6 mtr high existing pole complete with IP 66 control gear in separate compartment , extruded aluminium painted housing, a toughened glass protector etc., as required (POWERGRID approved make) each 4.00 998739 18% Included 0.18
MR Supply, installation, testing and commissioning of 40W LED Post top luminaire sealed to IP 66 and impact resistance complete with aluminium housing a canopy and high impact polycarbonate protector etc., complete as required (POWERGRID approved make) each 30.00 998739 18% Included 0.18
MR Supply, installation, testing and commissioning of 14 Watt LED prewired Bollard Lights complete with protector etc., as required to cat No. Bollard LED 14w-NW-Monichromatic. (POWERGRID approved make) each 23.00 18% Included 0.18
MR Supply, installation, testing and commissioning of base mounted above ground 6 meter long tubular G.I. pole along with single side 500 mm bracket suitable for installing 40/150 watt LED street light fitting. Bottom of the pole shall be 127 mm dia till 1 meter and 76 mm dia for 5 meter along with 16 mm thick base plate of size 300 mm x 300 mm. The column shall also be provided with flush door at the bottom with junction /looping box along with heavy duty connector etc., complete as required (POWERGRID approved make) each 19.00 998739 18% Included 0.18
MR Supply, installation, testing and commissioning of base mounted above ground 4 meter long tubular G.I. Pole of 114mm dia throughout & baseplate of size 300 mm x300 mm complete with flush door at the bottom with junction /laying box with H.D. connector etc., complete as required each 30.00 998739 18% Included 0.18
MR 40 W HP LED fixture solar street lighting system complete with electrical & electronic accessories and 6.0 mtr light G.I. painted pole complete with 200W solar panel 150 Ah Battery, charging and converter kit and battery box etc/, having back up for more than 10 hrs. as day once fully charged (POWERGRID approved make) nos 7.00 998739 18% Included 0.18
Total Charges (Excluding Tax) 0.00 0.00
Total GST on Price 0.00
1 Total charges
2 Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name : 0.00
Designation : 0.00
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 4
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
Rajasthan Projects Office, Multipackage Discount #REF!
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR Ref Description Unit Quantity SAC Code WhetherHSN in column ‘5’ is confirmed. If not indicate applicable theHSNC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
1 1.10.1 Wiring for light point / fan point / exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.:Group A Point 313 995461 18% Included 0.18
2 1.10.2 Wiring for light point / fan point / exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.:Group B Point 188 995461 18% Included 0.18
3 1.12 Wiring for light / power plug with 2X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 1136 995461 18% Included 0.18
4 1.13 Wiring for light/power plug with 4X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 Sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 1302 995461 18% Included 0.18
5 1.14.1 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 1592 995461 18% Included 0.18
6 1.14.4 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For MCB Socket) Metre 1148 995461 18% Included 0.18
7 1.14.5 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 2x10 sqmm +1x10 sq. mm earth wire (For submain) Metre 632 995461 18% Included 0.18
8 1.14.6 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 2 X 16 sq. mm + 1 X 6 sq. mm earth wire Metre 50 995461 18% Included 0.18
9 1.14.11 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 125 995461 18% Included 0.18
10 1.18.2 Supplying and drawing following pair, 0.5 Sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.: 2 Pair Metre 918 995461 18% Included 0.18
11 1.19 Supplying and drawing co-axial TV Cable RG-6 grade 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. Metre 830 995461 18% Included 0.18
12 1.21.2 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same incase of recessed conduit as required for telephone and TV Points: 25 mm Metre 1748 995461 18% Included 0.18
13 1.22.2 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated seet cover in front including painting etc as required.: 100 mm X 100 mm X 60 mm deep Each 19 995461 18% Included 0.18
14 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : 5/6 amps switch Each 140 995461 18% Included 0.18
15 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: 3 pin5/6 amp socket outlet Each 97 995461 18% Included 0.18
16 1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: Telephone socket outlet Each 63 995461 18% Included 0.18
17 1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: T.V. antenna socket outlet Each 63 995461 18% Included 0.18
18 1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: Bell Push Each 20 995461 18% Included 0.18
19 1.25 Suplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 92 995461 18% Included 0.18
20 1.27.1 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular plate as required (for telephone and T.V. socket) : 1 or 2 Module (75 mm X 75 mm) Each 63 995461 18% Included 0.18
21 1.27.2 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular plate as required (for telephone and T.V. socket) : 3 Module (100 mmX75 mm) Each 63 995461 18% Included 0.18
22 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. Each 237 995461 18% Included 0.18
23 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. Each 109 995461 18% Included 0.18
24 1.38 Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. Each 20.00 995461 18% Included 0.18
25 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting/LED/ compact fluorescent fitting of all types, comlete with all accessories and tube etc. directly on celing/ wall, including connection with 1.5 Sq. mm FRLS PVC insulated, copper conductor, sigle core cable and earthing etc; as required. Each 85 995461 18% Included 0.18
26 1.35 Erection of wall bracket/ceiling fittings of all sizes and shapes containing LED lamps per fitting, complete with all accessories including connection etc. as required. Each 325 995461 18% Included 0.18
27 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 92 995461 18% Included 0.18
28 1.50.1 Installation of exhaust fan in the existng opening, including making good the damage, connection, testing , commissioning etc. as required. : Up to 450 mm sweep Each 54 995461 18% Included 0.18
29 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 54 995461 18% Included 0.18
30 1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Each 71 995461 18% Included 0.18
31 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 8 way , Double door Each 6 998736 18% Included 0.18
32 2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 16 way, Double door Each 12 998736 18% Included 0.18
33 2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) :8 way (4+24), Double door Each 1 998736 18% Included 0.18
34 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit brealer suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. :Single pole Each 346 998736 18% Included 0.18
35 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral ), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 miliamperes in the sxisting MCB DB complete with connections, testing and commissioning etc. as required. : 40A Each 14 998736 18% Included 0.18
36 2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral ), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 miliamperes in the sxisting MCB DB complete with connections, testing and commissioning etc. as required. : 63A Each 5 998736 18% Included 0.18
37 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts''C'' curve DP MCB complete with connections , testing and commissioning etc. as required. ( For Common Lights & Stairs) Each 5 998736 18% Included 0.18
38 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 59 998736 18% Included 0.18
39 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 5 998736 18% Included 0.18
40 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal or coke and salt as required. Set 10 998739 18% Included 0.18
41 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 50 998739 18% Included 0.18
42 14.16.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 200 mm dia (OD-200 mm & ID-175 mm nominal) Metre 36 995424 18% Included 0.18
43 DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia, round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. each 92 995476 18% Included 0.18
44 NSE-1 Supply installation, testing and commissioning of Krone type tag block of 10 pair complete with back mount frame, modules, etc in a lockable metal box including connection etc, as required Each 6 995461 18% Included 0.18
45 NSE-2 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) 18W LED tube essential on batten Each 85 998739 18% Included 0.18
46 NSE-3 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) 10W LED surface down lighter round Each 177 998739 18% Included 0.18
47 NSE-4 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) Bracket Light fitting complete with 7W LED Lamp Complete Each 102 998739 18% Included 0.18
48 NSE-5 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) Bulk Head 9W Each 18 998739 18% Included 0.18
49 NSE-6 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) Surface mounted 1x11W CFL mirror Lights Each 27 998739 18% Included 0.18
50 NSE-7 Supplying prewired fluorescent fitting/LED fluorescent fitting surface/recess type stove enameled. Control gear duly wired complete and end plates/retainers in ready to use complete as required. (Fitting shall be supplied as per given ref. cat no or other equivalent POWERGRID approved make) Chandeliar Suspended (Antique design with 5 lamps) Each 1 998739 18% Included 0.18
51 NSE-8 Supplying of white colour blades ceiling fans of following sizes capacitor type complete with down rod canopies, hanging shackles, blades, without requlator suitable for use on 220/240 volts 50 Hz. Single Phase A.C. supply conforming to 15-374/1979 class I as desired 1200 mm sweep Each 68 998731 18% Included 0.18
52 NSE-9 Supplying of white colour blades ceiling fans of following sizes capacitor type complete with down rod canopies, hanging shackles, blades, without requlator suitable for use on 220/240 volts 50 Hz. Single Phase A.C. supply conforming to 15-374/1979 class I as desired 1400 mm sweep Each 24 998731 18% Included 0.18
53 NSE-10 Supply of metal type exhaust fans suitable for 220/240 Volts 50 Hz. Ac supply of 900 RPM single Phase AC supply complete with ,shutter etc; as required. 300 mm ventilating Fan Each 60 998731 18% Included 0.18
54 NSE-11 Supply and installation of wall bracket fan of 300mm , sweep complete with fan motor, blades etc. with all accessories etc. of approved make as required.(Make : Bajaj / Crompton / Havells) Each 6 998731 18% Included 0.18
55 NSE-12 Supply installation testing and commissioning of cubical type compartmentalized meter board for 4 meters, made of 1.6mm thick sheet steel, duly powder coated, integral loose wire box complete with 1 no 63 Amp 4 Pole 25 KA MCCB, insulated copper bus bars, 200 amps capacity. Each meter having one No. 40 Amp DP MCB, with single phase 10/40 amp energy meter, prewired from bus bar upto connector block (for each quarter) in loose wire box/cable alloy, locking/ceiling arrangement for each compartment ) bus bar chamber etc., as required. set 5 998736 18% Included 0.18
56 NSE-13 Supply, installation, testing and commissioning of Electric Geyser (Inner tank material as Stainless Steel) complete in all respects as required: Storage capacity 25 L Each 23 998736 18% Included 0.18
57 NSE-14 Supply, installation, testing and commissioning of Electric Geyser(Inner tank material as Stainless Steel) complete in all respects as required: Storage capacity 10 L Each 19 998736 18% Included 0.18
58 NSE-15 Supply, installation, testing and commissioning water meter (made of primary material-Brass) consisting of accessories complete in all respects as required:50 mm nominal bore Each 17 995462 18% Included 0.18
Total charges (Excluding Tax) 0.00
1 Total GST on Price 0.00 0
2 Total charges
3 Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 3
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(SUMMARY OF TAXES & DUTIES)
Bidder’s Name and Address To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office,
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
Sl. No. Description Total Price (INR)
1 Total GST for Supply of Goods/ Services between the Contractor and the Employer (identified in Schedule 2) which are not included in the Unit price as per the provision of the Bidding Documents, as applicable. 0.00
Date : --2025 Printed Name : 0
Place : 00-Jan-00 Designation : 0
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 4
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(GRAND SUMMARY)
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office,
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 2 0.00 0.00 0
Civil Works price
2 TOTAL SCHEDULE NO. 3 0.00 0 0 0.00
External Electrification Price
3 TOTAL SCHEDULE NO.4 0.00 0
Internal Electrification Price
4 TOTAL SCHEDULE NO. 5 #REF! #REF!
External Water Supply, Sewerage and pumps & Equipments Price
5 TOTAL SCHEDULE NO.6 #REF! #REF!
Road Work for Residential complex price
2 TOTAL SCHEDULE NO. 3 0.00
Total GST for Schedule-2
3 GRAND TOTAL [1+2] 0.00 0
Date : --2025 Printed Name : 0
Place : 00-Jan-00 Designation : 0
This letter of discount is optional. Bidder may / may not offer any discount.
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Letter of Discount
LETTER OF DISCOUNT
Contracts & Material
Power Grid Corporation of India Ltd.,
B-9, Qutab Institutional Area,
Katwaria Sarai,
New Delhi-110016
Subject : Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us . [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1,2,3] In Rs. #REF! #REF!
1 Discount on percent basis on total price quoted by us [The discount shall be proportionately applicable on all the items of all the Schdules ] In Percent (%) #REF! 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.00% Schedule-1 : Ex works prices #REF!
Schedule-1 : Ex works prices (Bought Out Only) In Rs. #REF! #REF! Schedule-1 : (Bought Out Only) #REF!
Schedule-2 : Freight & Insurance In Rs. #REF! #REF! Schedule-2 : Freight & Insurance #REF!
Schedule-3 : Installation Charges In Rs. #REF! #REF! Schedule-3 : AMC Charges #REF!
Schedule-7 : Type Test Charges In Rs. #REF! Schedule-6 : Type Test Charges #REF!
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-1 : Ex works prices (Bought Out Only) In Percent (%) #REF! 0.00%
Schedule-2 : Freight & Insurance In Percent (%) #REF! 0.00%
Schedule-3 : Installation Charges In Percent (%) #REF! 0.00%
Schedule-7 : Type Test Charges In Percent (%) #REF!
3 Multipackage discount on Total Price on LS Basis quoted without T&D (Applicable on this package only if other package covered under the same bidding Document is also awarded to us, Discount) #REF!
4 Multipackage discount on Total Price on percent Basis quoted without T&D (Applicable on this package only if other package covered under the same bidding Document is also awarded to us, Discount) #REF!
Discount(s) offered at sl. No. 1 to 4 will automatically get displayed and accounted for in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 3 & 4 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : --2025 Printed Name : 0
Place : 00-Jan-00 Designation : 0
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Schedule - 5A After Discount
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(GRAND SUMMARY : AFTER DISCOUNT)
Bidder’s Name and Address To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office,
4th Floor, REIL House, Shipra Path,
Mansarovar, Jaipur-302020 Rajasthan
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 2 0.00 #REF!
Civil & Electrical Works price
2 TOTAL SCHEDULE NO. 3 0.00
External Electrification Price
3 TOTAL SCHEDULE NO.4 0.00
Internal Electrification Price
4 TOTAL SCHEDULE NO. 5
External Water Supply, Sewerage and pumps & Equipments Price
5 TOTAL SCHEDULE NO. 6
Road Work for Residential complex price
2 TOTAL SCHEDULE NO. 3 0.00
Total GST for Schedule-2
3 GRAND TOTAL [1+2] 0.00
Date : --2025 Printed Name : 0
Place : 00-Jan-00 Designation : 0
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Bid Form 2nd Envelope (Price Bid) Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : --2025 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts & Material 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
Rajasthan Projects Office, 11 th 11 November
4th Floor, REIL House, Shipra Path, 12 th 12 December
Mansarovar, Jaipur-302020 Rajasthan 13 th
Name of Contract : Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 2 Civil and Sanitary Works
Schedule 3 Total GST
Schedule 4 Total (schedule 2 and 3) without discount
Schedule 5 Total (schedule 2 and 3) with Discount
Sched-6 Discount Discount
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Date : --2025 Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package : Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Tender Enquiry No.: NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409
Completion Schedule: 09 Months from the issuance of LOA
: Attachments : General guidelines for filling up the Attachments
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Specification No.: NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409
1 Fill up only green shaded cells in the relevent attachments.
2 Various Attachments and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(s) and as per remarks in the safety pact.
7 Attachment-21 to 25: To be submitted as perproforma provided in the bidding document.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Sole Bidder 1
JV (Joint Venture) 2 or More
Whether Bidder is MSE [Select from drop down menu] 0
Whether Meets criteria of minimum local content as per provisions of bidding document and as per public procurement (preference to make in India) order, 2017 as amended upto date [Select from drop down menu] 0
You are not eligible to bid in subject package 0
Specify type of Bidder (Please note that JV's are not allowed to participate in the tender) [Select from drop down menu] SOLE BIDDER SOLE BIDDER 1 0
1 JOINT VENTURE (JV)
Name of Sole Bidder
Complete Address of Sole Bidder with Pin Code
Name of Contact Person
Mobile Number of Contact Person
Email Id of Contact Person
Name of Alternate Contact Person
Mobile Number of Alternat Contact Person
Email Id of Alternate Contact Person
Address of other Partner
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any) …… ……. …….. …… ……. ……..
Any Tower Parts Manufacturer proposed other than the bidder [Yes / No] No
Proposed Tower Parts Manufacturer other than the bidder, if any [Maximum two nos.]
NOTE: (In case of JV, all partners of the Joint Venture shall be MSEs to consdier its bid as bid from MSE, JV bidder with at least one non-MSE partner (whether lead or other partner) shall not be eligible for the benefit available to the MSE bidders)
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-3(JV) SOLE BIDDER 0
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address : To:
Contract & Materials deprtament 1 &
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
Name(s) and Addresse(s) of other partner(s)
JV's are not allowed to participate in this Tender.
Date : #REF! Printed Name : 0
Place : Designation : 09 Months from the issuance of LOA
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 ATTACHMENT-3 (QR)
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Qualifying Requirement Data)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name: Power Grid Corporation of India Ltd.,
Address: Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
THIS ATTACHMENT IS NOT APPLICABLE.
We have submitted our bid as 1
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b)** Joint Venture Agreement.
[** To be submitted only in case of Joint Ventures. Strike off in case of individual firms.]
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars For Sole Bidder 1 1
1 Name of the Firm 0
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
[Necessary documents to establish legal status of the bidder (all the partners in case of Joint Venture) should be enclosed with the bid].
2.0 TECHNICAL REQUIREMENTS {Reference para 1.1 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1 The bidder should have the manufactured and supplied latticed steel structures (transmission line tower parts, microwave tower parts, substation structures etc.) as on the originally scheduled date of bid opening ( i.e., 09/01/2019)
In case bidder is a holding company, the technical experience referred to in clause 2.1 shall be of that holding company only (i.e. excluding its subsidiaries/ group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1 shall be of that subsidiary company only (i.e., excluding its holding company).
Format for individual firm:
Bidder’s Name/Tower Manufacturer : 1
Single Firm/Lead Partner/Other Partners of a JV :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
(a)(i) Scope of work executed under the above contract (Tick only whichever is/are applicable)
4 Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1
i) Type of steel supplied (transmission line tower parts, microwave tower parts, substation structures etc.
ii) Transmission Line for which Steel supplied
iii) Value of work Rs. in crore
2.2 The bidder should have its own manufacturing facilities for the transmission line towers and tower parts having the following minimum manufacturing capacities and manufacturing experience: a. Manufacturing capacity per financial year: 4160 MT per year b. Manufacturing experience: Average quantity of latticed steel structures (transmission line tower parts, microwave tower parts, substation structures etc.) manufactured per financial year, during the last three financial years should not be less than i.e. (Minimum average Quantity manufactured in a year) 2080 MT per year-
2 Manufacturing capacity of the bidder per financial year(in MT):
6 Manufacturing experience: Average quantity of latticed steel structures (transmission line tower parts, microwave tower parts, substation structures etc.) manufactured per financial year, during the last three financial years
7 Details of documents furnished in the Bid, in support of the aforesaid data/details/information
3.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.4 of Annexure-A (BDS)}
a) Net worth for last 3 financial years should be positive. (Total Asset – Total liabilities for last three years shall be positive)
b) Minimum Average Annual Turnover@ (MAAT) for best three years i.e. 36 months out of last five financial years (Starting from Year 2014-15) of the bidder should be not be less than Rs. 17.45 Crores.
* Note: @Annual total income as incorporated in the profit and loss account excluding non-recurring income, i.e. sale of fixed assets.
c) Bidder shall have liquid assets (L.A) or/and evidence of access to or availability of credit facilities of not less than Rs.2.91 Crores.
Note: In case bidder is a holding company, the Financial Position referred to in clause 1.2 shall be of that holding company only (i.e. excluding its subsidiaries/ group companies). In case bidder is a subsidiary of a holding company, the Financial Position referred to in clause 1.2 shall be of that subsidiary company only (i.e., excluding its holding company).
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data:
Details of documentary evidence submitted in support of Qualification Data
Networth (in Crores)
Sl No Financial Year
Do you have audited results for FY 2018-19 Yes
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Crores)
Sl No Financial Year
Average Annual Turnover for best Three Years is
C Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture Bids {Reference Annexure-A (BDS)}
a) a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet jointly the Technical experience requirements. The figure of average annual turnover for each of the partners of the JV shall be added together to determine the JV’s compliance with the financial position criteria. However, for a JV to be qualified, the partner(s) of the JV must also meet the following minimum criteria:
(i) (i) The lead partner shall meet, not less than 40% of the financial position criteria given at Part-B above.
(ii) (ii) Each of the other partner(s) shall meet, not less than 25% of the financial position criteria given at Part-B above.
b) In case of Joint Venture, the following conditions shall also apply:
c) (i) In case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners. (ii) One of the partners shall be nominated as Lead Partner, and this authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatories of all the partners. (iii) The Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract, including payment, shall be done exclusively with the Lead Partner as per power conferred to him in the Power of Attorney. (iv) All partners of the Joint Venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms, and a statement to this effect shall be included in the authorization mentioned under (ii) above as well as in the Bid Form and in the Contract Form (in case of a successful bid). (v) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-4
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
country. country. [Name of Countries], [Name of Countries],
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-4(A)
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-4(B)
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : #REF! Printed Name :
Place : Designation :
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-5
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
1.We hereby furnish the details of the items/ sub-assemblies (supply items), we propose to buy for the purpose of furnishing and installation of the subject Package :
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
2. We hereby delare that we would not subcontract the erection portion of the contract without prior approval of the Employer.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 ATTACHMENT-5A
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package :
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category (Micro or Small)
2. 2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-6
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-7
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Details of Alternative Bid)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
No Alternative Bid
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-9
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Work Completion Schedule)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. for the period commencing from the effective date of Contract to us :
We confirm that materials will be supplied as per the time limit agreed at the time of contract.
Sl. No. Description of Work Period in months from the effective date of contract 09 Months from the issuance of LOA
765KV D/C (Hexa) Wardha - Aurangabad Transmission Line-II 400KV D/C Quad Aurangabad – Boisar Transmission line 400KV D/C (Twin) Akola – Aurangabad Transmission line 765kV S/C Seoni-Wardha Transmission Line CKT-I 765kV S/C Seoni-Wardha Transmission Line CKT-II 400 kV D/C Wardha-Akola Transmission Line
1 Manufacturing
a) commencement
2 Shipments & Delivery
a) commencement
#REF! #REF! #REF! #REF! #REF! #REF!
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-10
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Guarantee Declaration)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
We conform that the equipments offered shall have minimum (or a muximum, as the case may be) performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-11
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly,We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-11
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name :
Place : 0 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-11
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name :
Place : 0 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-12
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Price Adjustment Data)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
1 For Fabricated Tower Parts (including bolts & nuts)
A Steel Blooms, co-eifciant a = IEEMA
B Electrolytic High Grade Zinc, co-efficient b = IEEMA
C Labour, Co-efficient l= 0.85 Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Invalid Entry !
Coefficient ‘a’ shall be between 0.51 to 0.57 and coefficient ‘b’ shall be between 0.08 to 0.10 and coefficient ‘l’ shall be between 0.20 to 0.24 and sum of Coefficients ‘a’, ‘b’ and ‘l’ shall be 0.85
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-13
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Declaration regarding Social Accountability)
Bidder’s Name and Address : To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : Rajasthan Projects Office
4th Floor, REIL House,
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-14
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
Integrity Pact is annexed separately herewith this Volume (To be submitted in hard copy-two sets in original on Rs. 100/- stamp paper).
Date : #REF! Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (n).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 1 of 8
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. Package and Specification Number NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409
POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors."
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles
(a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to
(b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution
(c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 2 of 8
(a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract
(b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
(c ) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
(d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
(e ) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
(f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID
(g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 4 of 8
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or its subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter
(10) The word ‘IEM’ would include both singular and plural
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-15
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises
Bidder’s Name and Address : Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3.(a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3.(b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) 0
3.(c) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3.(d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No)
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6. PF Registration No. of the Company
7. PF Regional Office covered (with Address)
8. Name of Contact Person
9. Contact Details
10. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11. 9 digit MICR code printed at bottom in middle, next to cheque no.
12. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-16
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Additional Information)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-17
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-17
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials deprtament
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. Northern Region –I, Regional Headquarter,
…… ……. …….. …… ……. …….. SCO Bay No. 5 to 10, Sector 16A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : #REF! Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Attachment-17
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : #REF! Printed Name :
Place : Designation :
#REF! Attachment-19
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
Faridabad-121002, Haryana
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : #REF! Printed Name :
Place : Designation :
#REF! Attachment-20
Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation.
(Declaration of Key Managerial Person and Power of Attorney holder)
Bidder’s Name and Address : To:
Contract & Materials deprtament
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region –I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A
1. We confirm that the declarations made in our bid, particularly Attachment-3 (QR) regarding eligibility/qualification data and documents submitted in our bid in support of the declarations, are true and correct to the best of our knowledge. 2. We further confirm that we have filled up Attachment-3(QR). We also confirm that in support of meeting the Technical experience requirement as per Annexure-A (BDS), we have enclosed self-certified copy of Contract/ Award Letter and certificate from the utility for which the contract has been executed. 3. We shall furnish clarification to bid, if any sought by Employer pursuant to ITB clause 21.1. We understand that if we fail to rectify/furnish the requested documents if any, within 7 working days’ notice, our bid is liable to be rejected. 4. We understand that any false declaration and/or misrepresentation of facts and/or furnishing of false/forged documents /information may lead to our debarment from participation in Employer tenders and that our Bid Security/ Contract Performance Guarantee may be forfeited besides other actions as deemed to be appropriate as per the provisions of the Bidding Document/Integrity Pact/Employer’s policy.
5*. Our Balance Bid Capacity net of works under execution, calculated as per Clause ITB 23.2.1 (i.e. 3T-B), as on 1st date** of the Quarter in which First Envelope Bids are to be opened i.e. 01st
(MM/YYYY) in equivalent Indian Rupees is
Crore. The details of value used for working out the Balance Bid Capacity as above, are as follows:
A. Maximum value of Transmission & Distribution (T&D) works (including substation, transmission lines, distribution for all verticals), executed in any one financial year during the last 5 financial years taking into account the completed as well as the works in progress
S N FY Value of Total Sales (including Taxes and Duties)(T)
B. Value of existing commitments and ongoing similar works yet to be completed as on the 1st date of quarter of the financial year in which the bids are opened(B) as on 1st date of the Quarter in which First Envelope Bids are to be opened
S N Value of Balance Works (B1) against the Contracts awarded by Employer Value of Balance Works (B2) against the Contracts awarded by Utilities other than Employer Total value of Balance Works (B){B=B1+B2}
[**1st day of the quarter in which the first envelope bids are opened for e.g. If the actual date of opening of first envelope bids is 15th June 2016, the Balance bid capacity as on 01st April 2016 is to be declared)] *(Applicable only in case of package for which the stipulated Qualification Requirements in respect of Technical experience pertains primarily to erection, testing and commissioning/civil works viz. transmission Line tower packages/Substation package/civil works package etc.)
6***. Our/Our proposed manufacturer’s annual manufacturing capacity as certified by a Chartered Engineer or similar Professional/ Professional body/Govt Agencies is:
MT/annum (for tower/tower parts)
[Certificate from Chartered Engineer or similar Professional/ Professional body/Govt Agencies in the country of the bidder/proposed manufacturer is to be enclosed along with this Attachment. Annual manufacturing capacity of all the manufacturers to be furnished separately] ***(Applicable only in case of Tower packages with scope for tower supply)
7. Notwithstanding above, we also understand that the Bid Capacity/Manufacturing Capacity as declared hereinabove, shall be subject to assessment, if any, by the Employer, which shall be final and binding. We also confirm that the Employer may verify the supporting documents/ details in connection with above declarations. We further understand that in case of any unethical practices inter-alia including any misrepresentation of facts, submission of false and/or forged details/ documents/ declaration by us, we may be debarred from the participation in Employer’s tenders in future as considered appropriate by Employer and our Bid Security/ Contract Performance Guarantee shall be forfeited besides taking other actions as deemed appropriate.
Date : #REF! Printed Name :
Place : Designation :
Note: Key Managerial Personnel (KMP) of the company shall include CEO/Managing Director/ Company Secretary/ Director/ CFO/any of the partner in case of partnership firm/any other officer entrusted with substantial powers of the management of the affairs of the company/firm.
Bidders are advised to print this declaration on the Company Letter Head and upload the duly signed and scanned copy along with the First Envelope Bid.
NR1/T/W-CIVIL/DOM/I00/25/05161 – RFx Number 5002004409 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 00-Jan-00 6 six 6 th 0 6 June
7 seven 7 th 1 7 July
To: 8 eight 8 th January 8 August
Contracts & Material 9 nine 9 th 1900 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Rajasthan Projects Office 11 eleven 11 th 11 November
4th Floor, REIL House, 12 twelve 12 th 12 December
Shipra Path, Mansarovar, Jaipur-302020 Rajasthan 13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of Transit Camp/Field Hostel at 765/400 kV Dausa New Substation. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 0 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
Or Online Payment Acknowledgement towards Bid Security for a sum of ................................................ (name of currency and amount in words and figures)
Or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II
(b) Attachment 2() : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
(c) Attachment 3() : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). SOLE BIDDER Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 1 Not Applicable 24 th
(d) Attachment 4() : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5() : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A() : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works 27 th
(g) Attachment 6() : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 28 th
(h) Attachment 7() : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 29 th
(i) Attachment 8() : Manufacturer’s Authorisation Forms. 30 th
(j) Attachment 9() : Work Completion Schedule. 31 st
(k) Attachment 10() : Guarantee Declaration.
(l) Attachment 11() : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12() : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13() : Declaration regarding Social Accountability.
(o) Attachment 14() : Affidavit
(p) Attachment 15() : Declaration by the Bidder regarding events encountered
(q) Attachment 16() : Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
(r) Attachment 17() : Affidavit of Self certification regarding Minimum Local Content
(s) Attachment 18() : Safety Pact
(t) Attachment 18 () : Certificate from statutory auditor or cost auditor of the company
(u) Attachment 19 () : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 20 () : Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order December 2018, if applicable
(w) Attachment 21 () : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, and MoP Order December 2018, if applicable
(x) Attachment 22 () : Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
2.2 We are a Micro and Small Enterprise (MSE) registered with
a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. (applicable for MSE only)
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.7 Contractors Responsibility
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and Address of Agent Amount and Currency Purpose of Commission or Gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : 00-Jan-00 Printed Name :
Place : 00-Jan-00 Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
Other Partner -1 Other Partner -2 2
Printed Name : Printed Name :
Designation : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2() Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2() Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_Schedule.xlsx
xlsx • 0.43 MB
Attachemnt-22_Declaration regarding events encountered.docx
docx • 0.03 MB
Attachment 21-Affidavit for correctness of information.docx
docx • 0.02 MB
Attachment 23- Certification by the Bidder as per DoE order in line with ITB 2-1.docx
docx • 0.02 MB
Attachment-20 KMP Declaration Format.doc
doc • 0.06 MB
Attachment-24_Affidavit for self-certification regarding Minimum Local Content.DOCX
docx • 0.02 MB
First Envelope and Bid Forms.xlsx
xlsx • 1.84 MB
INTEGRITY PACT Proforma.pdf
pdf • 0.20 MB
Legends for Units.pdf
pdf • 0.03 MB
SAFETY PACT.pdf
pdf • 0.36 MB
Civil TS.pdf
pdf • 0.99 MB
SCC.pdf
pdf • 0.30 MB
SFQP Site.pdf
pdf • 2.86 MB
Transit Camp_Drawing.pdf
pdf • 3.93 MB
Underground Water Tank.pdf
pdf • 2.63 MB
00-Cover Page_Vol-I.doc
doc • 0.28 MB
01-Section - I IFB SSTE Vol-I Civil.docx
docx • 0.05 MB
02 Section-II ITB SSTE Civil (Feb-19) Vol-I.pdf
pdf • 0.67 MB
03 Section - III_BDS Civil Vol-I.docx
docx • 0.08 MB
04-Section-IV GCC Civil works Vol-I.pdf
pdf • 0.67 MB
05 Section - V SCC Civil Vol-I.docx
docx • 0.07 MB
05_01_Appendix-I to SCC.pdf
pdf • 0.35 MB
06 Section-VI Forms and procedures.docx
docx • 0.11 MB
Annexure-II Checklist & Safety Provision.pdf
pdf • 0.27 MB
QR.pdf
pdf • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .