| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹28.5 L+₹1.0 L (3.76%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹25.7 L
EMD Value
₹51,500
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
ADDITION, ALTERATION TO SMQS AND CERTAIN MINOR WORKS UNDER GE (AF) LOHEGAON AT AF STN PUNE
2023_MES_576027_1
8656/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹51,500
Yes
7 Apr 2023
19 Jan 2023
21 Feb 2023
19 Jan 2023
14 Feb 2023
2 Feb 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. liad in any type of motar all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving's not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 500m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed
M & L cement concrete type B0 1:2:4 (12.5 mm graded agg) 25mm thick as in sub floors complete all as specified and directed.
Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors {Superior/Premium quality}, set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all specified and directed.
Ditto all as per Ser Item No 7.00 above but as in skirting/dados over and including 10mm thick rendering in CM 1:3 complete all as specified and directed.
M&L Glazed Ceramic Coloured Tiles, 350X250X7mm/450X350X7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:4 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
M&L granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over 15 mm thick screed bed in CM(1:6) complete all as specified and as directed.
M & L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed.
Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete
M & L rendering 10mm thick on surface of brick work/concrete wall surface in CM 1:6 and is to be finished even and smooth with out using extra cement complete all as specified directed
M & L for 5mm thick cement plaster in CM 1:3 on fair faces of brick or concrete ceiling surface and finishing the surface even and smooth (without using extra cement) etc.
M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) using 20mm graded aggregates and set in CM (1:6).
M&L for RCC M-20 (Nominal Mix) using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelve including sup- ports, overhangs, etc. also splays between floors and beams, etc.of rough finished of concrete complete all as specified & directed
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm dia
S&F for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors in repairs
Fixing only 15mm dia tubes, any grade, to walls and ceilings or laying in floors
S&F for GI tubing 20mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs
Fixing only 20mm dia tubes, any grade, to walls and ceilings or laying in floors
Cutting of existing steel tubing for alternation or addition of 15m m dia pipes all as specified and directed.
Cutting of existing steel tubing for alternation or addition of 20m m dia pipes all as specified and directed.
Cutting chases pinning in making good to facing where required for concealed water tubing and making good cutting not xc 10 cm girth in stone/concrete walls complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous china, squatting pan of 'Orissa' pattern, long pan, size 580 mm x 440 mm, incl cones ,india rubber nozzle of WC pan,white, with 'P' of 'S' Trap, front or back inlet and foot rests any pattern, including connection to trap and connection flushing pipe and antisyphonage pipe including concrete bedding complete all as specified and as directed.
S&F in repair 15 mm dia CP brass PVC connection 60 cm long including check nuts etc complete all as specified and directed
S&F in repair for 15 mm bore bib tap chromium plated cast copper alloy with wall flange complete all as specified and directed.
Dismantling of PVC water tanks of exc 250 and n.exc 500 ltr capacity and removing to store and all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene double layer water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 20mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC low level flushing system plastic valve with inlet ball valve float chain and ball (of capacity 10 liters) ISI Marked incl 32mm PVC flush pipe complete all as specified and directed .
S&F in repair vitreous china wash hand basin, white, 550 mm x 400 mm flat back, including providing CI brackets, fancy type CP Pillar Tap, PVC waste pipe 32mm dia, chromium plated, brass, waste coupling, incl 32 mm dia all as specified and as directed.
S & F in repair 15mm dia angle valves fancy , cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed as complete all as specified and directed.
S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed.
S &F in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed.
S & F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed bothends for iron pipe 20 mm bore and fixed
S &F Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed.
S&F in repair 15mm dia CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed as approved complete all as specified.
S &F in repair 15mm dia stop valves cast copper alloy, screwed donw high pressure with crutch or butterfly handle screwed both ends for iorn pipe or for unions and fixed (concealed type) all as specified and directed.
S&F Sink made of stainless steel with drainage board1mm thick kitchen or laboratory with plug washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915x460mm bowl size 410x330x160mm complete all as specified and as directed
S & F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) all as specified and directed
S&F CP soap case all as specified and directed
S&F in repairs stainless steel kitchen plate rack of 0.65 mm thick of approved make with plugs, washers, over all size 750mm x 600m complete all as specified and directed.
Demolition and breaking up drain pipes Upto 150 mm (Salt glazed ware /PVC/ AC or Reinforced concrete) set in cement mortar
S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors
Ditto all as per Ser Item No. 48.00 above but 110mm dia complete all as specified and directed.
M&L for PVC (SWR) bends of any radius with oval and access door of 75mm dia
Ditto all as per Ser Item No. 50.00 above but 110mm dia complete all as specified and directed.
S &F 110mm dia of PVC (SWR) branch piece, single (Double Y) equal or unequal all as specified and directed.
M&L for PVC (SWR) vent cowl of 110mm dia
Taking down chowkat with shutter without taking out shutter from the frame exc 1.5 and n.exc 4 Sqm each
Taking down chowkat with shutter without taking out shutter from the frame n.exc 1.5 Sqm.
Taking down Shutters of description exc 1sq.m and n exc 2 sq. m each complete all as specified and as directed.
Taking down shutters of any description n exc. 1 Sqm each complete all as specified and directed.
Taking down Shutters of any description exc 1 sqm and n exc 2 Sqm each and refixing in other opening complete all as specified and directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as directed .
Supply and fix for solid PVC door frame of size 50mm x 47mm, made out of 5 mm thick plain colour PVC sheet, reinforced with mild steel square tube complete all as specified and as directed.
M & L for Factory made of 35 mm thick glazed and skeleton shutters made of 2nd class soft wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc for window, ventilator shutters, etc. as specified in SSR Part I, Section 8 clause 8.24(b) and fitted to chowkhat complete all as specified and directed .
S&F Stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
M & L for 2nd class HW 35mm Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneeringon both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc all as directed and specified .
M & L for Factory made of 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides: supplied and fitted to chowkats complete all as specified and directed .
S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
M & L for 105mm x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete, as specified, supplied and fixed all as specified and directed.
M & L for 125mm x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete, as specified, supplied and fixed all as specified and directed.
S F Butt hinges, extruded aluminium alloy with galvanised 100 mm long mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S & F 75 mm size Butt hinges, heavy weight, cold rolled mild steel, and fixed all as specified and directed.
S&F 150 mm long, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 100 mm long, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size handles, Extruded aluminium alloy handles, abricated type, anodised complete all as specified and as directed.
S&F 250 mm long aluminium anodised sliding door bolt, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
S & F for 300 mm, MS ordinary rat tail rod pattern Helical door springs including roller and roller plate complete all as specified and directed.
S&F aluminium powder coated three track sliding window with two shutters of 4mm thick tinted glass of modigaurd and one shutter of stainless steel wire mesh including good quality of bearing handle, locks, PVC rubber lining including frame work etc complete all as specified. :- Three track bottom – 20957, Three track top/vertical – 20958, Handle – 20606,Interlocking – 20605, Top and bottom – 20604.
M&L for aluminium powder coated louvered ventilator with provision of exhaust fan using ‘Jindal” aluminium section including glass and stainless steel wire mesh including frame work etc complete all as specified and directed by Engineer-in-Charge.
M & L for 18mm thick plywood BWR grade type BB fixed with fevicol and nails for working table / storage almirah to the size and pattern as shown in Drg and as directed by Engr-in-charge.
Ditto all as per Ser Item No 78.00 above but 12mm thick complete all as specified and directed.
M&L for 0.90mm thick decorative laminate type – I of surface finish (colour & pattern as approved) fixed with approved adhesive as per manufacturer’s instruction finished to approved size for working table all as directed by Engineer-in-Charge.
M&L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area n. exc. 6 Sqcm.
S &F of 125mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws all as specified and directed.
S&F in repairs 150 mm long aluminium, barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repairs 150 mm size handles, Extruded aluminium alloy handles, abricated type, anodised complete all as specified and as directed.
S & F in repair 100 mm size Butt hinges, heavy weight, cold rolled mild steel, and fixed all as specified and directed.
S&F in repair 250 mm long aluminium anodised sliding door bolt, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
S & F Harrison rail 20 mm Dia(Curtain rod)s, of anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc.all as specified and directed.
M&L for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
M & L for complete removal of existing treatment of walls plastered or unplastered, Washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant primer including making good the surface complete all as specified and directed.
M & L for preparation of newly plastered surfaces and priming plastered surfaces with alkali resistant primer and applying two coats of oil bound distemper on walls over 3mm thick putty complete all as specified and directed.
M & L for Preparation of old plastered surfaces/un plastered surfaces including brooming down with steel wire brushing scrapping down smoke spout moulds, moss and efflorescence, salt treating oil and greasy spots etc and applying one coat of white washing on old plastered surfaces of walls all as specified.
Ditto all as per ser Item No 91.00 above but on surface of on ceiling /soffits of slabs, chajjas all as specified and as directed at site complete all as specified and directed.
M & L for preperation of newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Ditto all as per Ser Item No. 93.00 above but on walls complete all as specified and directed.
M & L for Preparation of old painted wooden surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of new wooden surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paint over pink primer complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint for material and labour complete.
Preparation of new or previously un-treated surfaces of steel and applying two coat of synthetic enamel paint to steel surfaces over one coat of red oxide of any description not otherwise described over 10 cm width or girth complete all as specified and directed.
S&F PVC SWR floor trap of diameter of outlet 75mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
M&L(SWG) gully trap 100mm setting and jointing with solvent cement complete all as specified and directed.
S & F Grating doom 100mm dia of Stainless steel with holes for waste pipes all as specified and directed.
S & F Grating doom 100mm dia of stainless steel all as specified and directed.
S&F in repair galvanised mild steel steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
M&L for Providing cement concrete type C2 1:3:6 in win- dow or door cills, lintels,bressumers, steps, quoin blocks (foruse with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match etc.complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving's not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement & pigment complete all as specified and directed.
M&L Sand filling under precast concrete inter locking paver floors or in foundations or for laying blocks including watering and consolidation complete all as specified and directed.
M&L 75 thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) laying as in Sub base complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes, for laying cables etc or for laying of cables and getting out in soft/loose of soil
M&L 150mm dia RCC drain pipes class NP2 laid in treches & jointed for 150mm dia pipe in loose joints etc complete
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 150mm Dia ( Note : Work in Foule Position )
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm in soft/loose soils.
Removing the excavated surplus soils not exceeding 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested. (dia-150 mm)
M&L rendering 15mm thick in cm 1:4 on fair faces of brick work or concrete surface in external surfaces.
M&L Glazed Ceramic Coloured Tiles, 350X250X7mm/450X350X7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
M&L granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.
Stone slab 25 mm to 35 mm thick dressed true and square, in one length not less than 60cm and n. exc 120cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in mortarcomplete all as specified and directed.
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, coupling,washers and waste pipes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and directed.
M&L(SWG) gully trap 150mm setting and jointing with solvent cement complete all as specified and directed.
M & L rendering 15mm thick on surface of brick work/concrete surface in CM 1:6 and is to be finished even and smooth with out using extra cement complete all as specified directed
M&L for cement concrete in foundations, filling and mass concrete using type D2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed.
M & L for preparation of newly plastered surfaces and priming plastered surfaces with alkali resistant primer and applying two coats of oil bound distemper on walls complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Hard/ Dense soil
M&L for PCC 75mm thick type C2(1:3:6) using 40mm graded crushed aggregate as in sub base sub floor,and paving, complete all as specified and directed.
M & L Hardcore with broken stone of gauge exc 63mm but n exc 100mm, deposited, spread and levelled and layer n.exc 15cm thick, water and rolled/rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate as in sub base of floor and path, plinth protection finished even and smooth without using extra cement etc.complete all as specified and directed.
M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection
M&L for 10mm thick rendering on fair faces of brick works finished even andfair without using extra cement in cement mortar 1: 4 complete all as specified and as directed
S & F Grating 100mm dia of stainles steel all as specified and directed.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (110 mm bore) complete all as specified.
Ditto all as per Ser Item No. 131.00 above but 75 mm dia complete all as specified and directed.
M&L for PCC type B0 (1:2:4) using 12.5 mm graded crushed aggregate in coping , bands,damp proof courses,mass concrete etc all as specified and directed,.
M & L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil
M & L for P.C.C type D-2, 1:4:8 (40 MM graded aggregate), 100mm thick complete all as specified and directed.
M & L for Reinforced Cement concrete type B1 (1: 1 : 2) with 20 mm gradaed stone aggt. in foundations, filling and mass concrete complete all as specified and directed.
M & L for Expanded Polysterene EPS Insulation Bpard complete all as specified and directed
M&L for returning, filling incl spreading levelling watering and well ramming in layers n.exc 25 cm as in hard/dense soil.
M&L for Machine cut Kota stone slab flooring 20-25 mm thick including skirting over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
S& F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
M&L Framed work such as grills,Barred iron doors,Ladders, walk ways,frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Mild steel screw bolts of ength of bolt exc 5cm but n exc 10cm long, diameter of neck 11 to 15mm (machine made) with hexagonal or square heads,at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M&L for Forming mortice holes exc 50 but n exc 100 Cu cm for , fixing bolts ,balusters,newels,rag-bolts,etc and grouting with cement mortar 1:2 complete all as specified and directed.
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc all as directed.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire all as directed.
Taking down existing light fittings carefully after disconnecting the connection keeping separately and short out serviceable and unserviceable light fitting and keep serveable fitting in safe gard for reuse as reqired on site complete.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed
One light point controlled by one switch .
Bell point controlled by one switch .
One Fan/Exhaust point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Ditto all as per Ser Item No 148.00 here-in-before but with cable size 2.5 Sqmm for one 5 pin 15 Amps socket outlet on independent board incl multistranded insulated copper earth contunuity conductor of size 2.5 Sqmm all as specified and directed by Engineer-in-Charge.
Supply and fix Modular Socket 6A-2/3 pin combined module complete all as specified and directed.
S&F Modular Socket 6A/16A-2/3 pin combined 2 module complete all as specified and directed.
S&F Modular switch 1 way 16 A, 1 Module
S&F Modular switch 1 way 6A, 1 module
S& F Modular Bell push 6A 1 Module
Supply and fix bell electric 230V single pole complete all as specified and directed.
S&F Modular Fan step regulator 120W 2 Module complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm complete all as specified and directed.
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal.
S&F LED light fitting mirror type with high out put diffuser 2 feet 10 watt 220 AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of sutable size complete all as specified and directed.
S&F LED light fitting 1x10W bulkhead luminaires ncluding LED light driver holder conncting up with three core flexibe copper conductor cable of suitable size complete all as specified and directed.
S&F angle / batten holder insulated body with back plate for batten fittings complete all as specified and directed.
S&F 300 mm sweep Heavy duty Metal Exhaust fan with louvers, 1200 RPM with complete wiring and other fixing acessories as per requirement on site.
M&L for cutting wall for exhaust fan opening , the cutting mist be of suitable dimension to accommodate the exhaust fan and make good surface finish with cement plaster work complete all as specified and directed by Engr-in-Charge
S&F electrical water heater, storate type steel body with copper inner tank and heating element upto 2 kw capcity 25 Ltr BEE 5 star rated complete with all accessories such as safety valve , thermostate, NRV , connection piece etc
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar
Supply and fix MCB SPN 240 V, 40 Amps. complete all as directed at site.
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as directed at site.
M & L for sub main wiring with two runs of single core 6.0Sq mm Flame retardant PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
Taking down celing fan single phase 240 V 1200 mm/1400 mm sweep from the existing position includg disconnecting supply cable from ceiliing rose/connector opening ceiling fan carefuly and cleaning and washing the bearing/bushes throughly and applying necessary lubricants etc and anging in original position connecting and testing compete on competion of civil works of Bldg
Taking down the existng street ight fitting and Supply & fix ( in Replacement) energy saving and environnental frindly long life LED street light fitting 35 W 230 V outdoor type with high pressure die cast aluminum housig and heat resistant complete with impact and corrosion resisrant including thermal management in mutipe optics IP 65/IP66 rad way luminaries with LED as light source and lens embedded PC cover/toughened glass and impact resistce of IK07 and electronic driver fixed on pole/wall with and including suitable dia size bracket as per manufacturer recommendation bracket complee with MS flat iron clamps (clamp shall be 40x50 mm flat nts and blts and washers painting the clamp shall be 40x5 mm MS flat nts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified.
M & L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc.
Material and labour for taking down of old manual changeover switch and deposit to MES store and disconnecting of cables from change over switch and terminate the same cables in new AMF panel complete as directed by Engr-in-charge
Supply, Install, Test and Commissioning of AMF Panel for 160 KVA DG set outdoor type fabricated out of 3.15 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b ) 4 Pole power contactor 250 Amps Type MCX-34 - 02 Nos (c) DG VMR -01 Nos (b) MCCB 250 Amps, 25 KA - 03 No (e) Control Wiring & all acessories for AutomATiic & Manual Mode Operation
Supply and fix socket outlet 2-in-1, 3 pin ,5 amps, flush type complete all as specified.
Supply and fix heavy duty Air Circulator fans 230 volts sigle phase, 50 Hz oscillating 450 mm sweep suitable for wall mointing complete all as specified and directed on site.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 TR complete with fixing brackets, refrigerant piping, cable and drain water piping etc. as directed by Engr-in-Charge.
Supply and fixing of voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete on wall and making necessary electric connection with split AC unit all as directed.
M&L for Sheet metel enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts all as specified and directed by Engr-in-Charge
M&L for sub main wiring complete with two runs of single core 4 sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 sqmm single Flame retardan PVC insulated unshedthed multi stranded copper conducator green colour cable for continuous earthing complete in & including PVC casing & caping with all fitting & fixtures all as directed and specified ( Note Two runs of 4 sqmm copper cable and one run of 4 sqm copper cable including PVC casing & caping shall be measured and paid as one length).
Supply and fix wall mounted fan 400 mm sweep with complete wiring and other fixing accessories as per requirement on site.
Material and labour for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing based on 3 mtr long copper pipe 76 mm dia(ID) with wall thickness of 1.5 mm, copper strip 32x 6 mm ( strip in pipe type electrode )and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode ,including PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm).Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and other joints with nut bolt in addition to brazing and all as directed and specified by Engr-in-charge Note:- (i) Earth strip for grid network and from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately.
S & F copper earth continuity conductor or main earthing lead of size 20 x 3 mm fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situtation for earthing etc. as required complete all as directed by Engineer-in -charge.
S&F test point terminal block made out of gun metal or phosphorous bronze size 75x75x25 mm depth , drilled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete as directed .
Supply & fix aluminium strips 25x3.15 mm on porcelain insulator not more than 50 cm apart all as directed by Engr - in - Charge .
Supply and fix air termination single pointed aluminium 12 mm dia & 300 mm long
S&F porcelain insulators with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc .
S&F GI pipe medium grade 40 mm dia upto 0.7 meter with MS base plate of 5 mm thick of size 20x20 cm mounted on PCC structure complete all as specified and directed
M&L for cement concrete in foundations, filling and mass concrete type B2 (1:2:4) 40mm graded stone complete all as specified and directed
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised strip 32X6 mm dia by means of bolts, nuts, check nuts & washers etc connected to DBs all as shown in electrical plate No.3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation / earth work in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade,including GI strip 32x6 mm dia with GI protection pipe of 40 mm medium grade up to 7.5 meter length etc complete all as specified and directed.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:- 95 sqmm 3.5 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out in Soft/disintegrated rock for laying of cable / pole etc.
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm completed as directed
S& F cast iron LT cable route indicators round shape properly grouted complete all as specified and directed.
santulan & Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .