Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | L1 | Accepted-Finance Ok | |
| 2 | L2₹4.5 L+₹14,171.80 (3.22%)Accepted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | L2 | Accepted-Finance Ok | |
| 3 | Rejected-Technical | - | Rejected-Technical EMD as FDR not submitted | |
| 4 | Rejected-Technical | - | Rejected-Technical EMD as FDR not submitted | |
| 5 | Rejected-Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | - | Rejected-Technical EMD as FDR not submitted |
| Sl No | Description | Qty | Unit | M G Traders and Engineers L2 | MITTAL TRADING COMPANY L1 |
|---|---|---|---|---|---|
| 1.01 | Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust & vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non‑deteriorating neoprene rubber gaskets to provide protection. The each part of the fabricated panel will be strictly subjected to seven tank treatment and will indicate the following procedures. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 mm cross section. Each wire will be terminating with a copper ferule crimped to the wire panel sized 1600 X 1000 X 400 mm. Having following components of approved make. | 1 | Nos | 42,000 ₹49,560 | 40,000 ₹47,200 Lowest |
| 1.02 | MCCB 415V, FP 200 Amp 50 KA with spreader & handle. Make L&T/Siemens/DJB approved | 1 | Nos | 13,250 ₹15,635 | 12,500 ₹14,750 Lowest |
| 1.03 | MCCB 415V, TP 100 Amp 50 KA with spreader & handle. Make L&T/Siemens/DJB approved | 2 | Nos | 18,400 ₹21,712 | 18,000 ₹21,240 Lowest |
| 1.04 | MCB Single pole 6/10 Amp. Make L&T/Schneider/DJB approved | 16 | Nos | 4,960 ₹5,852.8 | 4,800 ₹5,664 Lowest |
| 1.05 | MCB Triple pole 32 Amp. Make L&T/Schneider/DJB approved | 2 | Nos | 2,100 ₹2,478 | 2,000 ₹2,360 Lowest |
| 1.06 | MCB Triple pole 63 Amp. Make L&T/Schneider/DJB approved | 2 | Nos | 3,040 ₹3,587.2 | 3,000 ₹3,540 Lowest |
| 1.07 | Amp Meter digital type Make AE/L&T | 5 | Nos | 5,100 ₹6,018 | 5,000 ₹5,900 Lowest |
| 1.08 | Volt Meter 0-500V Digital Type Make AE/L&T | 1 | Nos | 1,250 ₹1,475 | 1,200 ₹1,416 Lowest |
| 1.09 | MPP type power capacitor 10Kvar Unit 440V 3 phase Make Epcos/DJB approved | 2 | Nos | 10,300 ₹12,154 | 10,000 ₹11,800 Lowest |
| 1.10 | Motor protection relay MPR300 Make L&T/Siemens/DJB approved | 4 | Nos | 28,200 ₹33,276 | 28,000 ₹33,040 Lowest |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
19 Jan 2026, 3:00 pmClosed
Executive Engineer(E and M)M-10
Command Tank 1, SFS Flats, Dwarka Sector 7, Delhi- 110075
Replacement of LT panel at Dwarka Sector 7 BPS.
2026_DJB_284762_22
NIT NO. 22 (2025-26)/EE(EnM)M-10
Open Tender
Miscellaneous Works
Works
Office of Ex. Engineer(E and M)M-10
Please refer tender documents
2 documents required · 2 mandatory
₹500
Account No SB 06121000095461
₹9,000
19 Mar 2026
13 Jan 2026
19 Jan 2026
13 Jan 2026
19 Jan 2026
13 Jan 2026
Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust & vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non‑deteriorating neoprene rubber gaskets to provide protection. The each part of the fabricated panel will be strictly subjected to seven tank treatment and will indicate the following procedures. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 mm cross section. Each wire will be terminating with a copper ferule crimped to the wire panel sized 1600 X 1000 X 400 mm. Having following components of approved make.
MCCB 415V, FP 200 Amp 50 KA with spreader & handle. Make L&T/Siemens/DJB approved
MCCB 415V, TP 100 Amp 50 KA with spreader & handle. Make L&T/Siemens/DJB approved
MCB Single pole 6/10 Amp. Make L&T/Schneider/DJB approved
MCB Triple pole 32 Amp. Make L&T/Schneider/DJB approved
MCB Triple pole 63 Amp. Make L&T/Schneider/DJB approved
Amp Meter digital type Make AE/L&T
Volt Meter 0-500V Digital Type Make AE/L&T
MPP type power capacitor 10Kvar Unit 440V 3 phase Make Epcos/DJB approved
Motor protection relay MPR300 Make L&T/Siemens/DJB approved
Power contactor 220V 3phase 25Amp Make L&T/Schneider
Power contactor 220V 3phase 50Amp Make L&T/Schneider
Power contactor 220V 3phase 70Amp Make L&T/Schneider
Current Transformer 200/5 Make AE/Advance/Saviour
Current Transformer 100/5 Make AE/Advance/Saviour
Over load relay 30-50A Make L&T/Siemens
Over load relay 9-15A Make L&T/Siemens
Indicating lights LED type RYB & ON/OFF Make FTC/Havells/L&T
Star delta timer Make L&T/Siemens
On load 4 pole change over switch 200Amp Make Havells/Advance/DJB approved
PVC insulated aluminum armoured cable 4x35 sqmm Make Havells/Grandly/Gloster/DJB approved
PVC insulated copper flexible cable 3x16 sqmm Make Havells/Grandly/Gloster/DJB approved
Single phase preventer, make: DJB approved/ISI approved
Earthing with G.I. earth pipe 4.5 metre long 40 mm dia including accessories, masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. DSR Code 35.1.2
Supplying and laying 25mm x 5mm G.I. Strip at 0.50 metre below ground as strip earth electrode including connection/terminating with G.I. nut, bolt, spring washer etc. as required. Jointing shall be done by overlaping and with 2 sets of G.I. nut bolts and spring washer at 50 mm. DSR Code 35.1.9
Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut bolt, spring washer excavation and refilling etc. DSR Code 35.1.11
Fitting of above components in panel enclosure with terminal blocks, channels, ferrules, thimbles, support insulators on bus bar, required hardware's, control wiring in 1.5/2.5/4/6 sqmm wire complete in all respect
Dismantling of old panel, structure, damaged components and installation of new panel at site by making foundation, termination of cable both incoming & out going side, meggering of complete panel, fitting of the starter star delta including cable connection, functional testing of components at no load and testing of panel on load at site with site in charge. This includes cartage, loading & unloading etc.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
nit22.pdf
Tender Documents • 0.73 MB
BOQ_376670.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .