Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical All Ok |
| 2 | Accepted-Technical | Accepted-Technical All Ok |
Tender Value
₹33.9 L
EMD Value
₹25,500
Closing Date
20 Mar 2026, 5:30 pmClosed
Commissioner Of UMC
Chhatrapati Shivaji Bhavan Aagar Road Ujjain, UMC
Construction Of Sabhamandap Work At Kishanpura Gali No. 2 Shri Ramkrishn Tample In W-39
2026_UAD_483409_1
286/Zone 5/E-tender/2026
Open Tender
Civil Works - Others
Percentage
90 days
Shri Ramkrishn Tample W-39
As Per Tender Document
4 documents required · 4 mandatory
₹5,000
₹25,500
16 Apr 2026
18 Feb 2026
23 Mar 2026
18 Feb 2026
20 Mar 2026
18 Feb 2026
Demolishing lime concrete manually / by mechanical means and disposal of material within 50 meters lead as per direction of Engineer in charge.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in-charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge
Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. (Payment shall be made on the cross sectional area of R.C.C. or as per direction of Engineer -in-charge.
Extra for scrapping, cleaning and straightening reinforcement from R.C.C.
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in- In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead. Of area beyond 3 sq. meters
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead: Of area 3 sq. meters and below
Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead: Of sectional area 40 square centimeters and above.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,bolts,nuts,cutting rivets,welding etc. including dismembering and stacking within 50meters lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles upto 25 mm
For thickness of tiles above 25 mm and up to 40 mm
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
Dismantling old plaster or skirting upto 15 mm thickness, raking out joints and cleaning the surface for plaster upto two floor level including disposal of rubbish within 50 meters lead and including scaffolding etc.
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete Crusher Stone Dust
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete.
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete. Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete Moorum/Hard copra
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete.
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete Moorum/Hard copra
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete.
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for uspended floors, roofs, landings, balconies and access platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
12 mm cement plaster of mix : 1:4 (1 cement: 4 sand)
Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification.
Chequered terrazo tiles 18-20mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade using white cement
Providing and applying 1.0 mm thick white cement based wall putty of best quality, over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade New work (three or more coats)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Granite of any colour and shade Area of slab upto 0.50 sqm
Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing glazing in aluminium door, window,ventilator shutters and partitions etc. with EPDM Rubber neoprenegasket etc. complete as per the architectural drawings and thedirections of engineer-in- charge (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
With cement mortar 1:4 (1 cement : 4 fine sand)
SupplingandfixingofapprovedmakesteptypeelectronicFanregulator including connection etc. as required on existing board
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM Rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge (Cost of aluminium snap beading shall be paid in basic
Supply erectionandtestingofapprovedmakeelectricCeilingfanof doubleballbearingcompletewithstandarddownrod,canopy,hanging shackle,Aluminiumblades,withoutregulator,A.C.230-250voltsincluding connectionswithallnecessarymaterialco
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket OutletPointWith4Sq.mm.PVCinsulatedcableFRwithcoppermulti strandconductorISImarkedinSurfacerigidP.V.C.Conduit(MMS)ISI Markedofsuitablesizeincludingpaintingetc.with16Amp.F.T.Switch& Socket/S.S.Combined16Amp.ofISIMarkedand4Sq.mm.PVC insulatedcopperearthcontinuityconductorofgreencolourinsideconduit as per specification for short point
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket OutletPointWith4Sq.mm.PVCinsulatedcableFRwithcoppermulti strandconductorISImarkedinSurfacerigidP.V.C.Conduit(MMS)ISI Markedofsuitablesizeincludingpaintingetc.with16Amp.F.T.Switch& Socket/S.S.Combined16Amp.ofISIMarkedand4Sq.mm.PVC insulatedcopperearthcontinuityconductorofgreencolourinsideconduit as per specification for mediumn point
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket OutletPointWith4Sq.mm.PVCinsulatedcableFRwithcoppermulti strandconductorISImarkedinSurfacerigidP.V.C.Conduit(MMS)ISI Markedofsuitablesizeincludingpaintingetc.with16Amp.F.T.Switch& Socket/S.S.Combined16Amp.ofISIMarkedand4Sq.mm.PVC insulatedcopperearthcontinuityconductorofgreencolourinsideconduit as per specification for long point
Pointwiringincludingmetallicswitchbox,sheet,switches,sockets,lampholders/ceilingrosesetcwith1.5Sq.mm.PVCinsulatedcableFRwithcoppermultistrandconductorISImarkedinSurfacerigidP.V.C.conduit(MMS)ISIMarkedofsuitablesizeand1.5Sq.mm.PVCinsulatedcopperearthcontinuityconductorofgreencolourinsideconduitincludingpainting etc. as required as per specification for :- short point
Pointwiringincludingmetallicswitchbox,sheet,switches,sockets,lampholders/ceilingrosesetcwith1.5Sq.mm.PVCinsulatedcableFRwithcoppermultistrandconductorISImarkedinSurfacerigidP.V.C.conduit(MMS)ISIMarkedofsuitablesizeand1.5Sq.mm.PVCinsulatedcopperearthcontinuityconductorofgreencolourinsideconduitincludingpainting etc. as required as per specification for :- Midum point
Pointwiringincludingmetallicswitchbox,sheet,switches,sockets,lampholders/ceilingrosesetcwith1.5Sq.mm.PVCinsulatedcableFRwithcoppermultistrandconductorISImarkedinSurfacerigidP.V.C.conduit(MMS)ISIMarkedofsuitablesizeand1.5Sq.mm.PVCinsulatedcopperearthcontinuityconductorofgreencolourinsideconduitincludingpainting etc. as required as per specification for :- Long point
Supply FixingandTestingofCompactFlourescentLamp(CFL)with inbuiltelectronicballastISImarkedofapprovedmakeasrequiredasper specification 25 Watt Each 243.00
300mm sweep 900 RPM
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete.
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete Moorum/Hard copra
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete.
Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for uspended floors, roofs, landings, balconies and access platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Mild steel and Medium Tensile steel bars.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work will well burnt open bhatta bricks crushing strength not less than 25kg/cm² and water absoption not more than 20% in above plinth level upto floor two level in cm 1:6 including the cost of scaffholding etc.
12 mm cement plaster of mix : 1:4 (1 cement: 4 sand)
Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification.
Chequered terrazo tiles 18-20mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade using white cement
Providing and applying 1.0 mm thick white cement based wall putty of best quality, over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade New work (three or more coats)
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
tenderdocument.pdf
Tender Documents • 1.62 MB
BOQ_568166.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .