Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹97,620
Closing Date
26 Feb 2024, 4:00 pmClosed
Executive Engineer, PWD Bameng Division Veno
O/o the Executive Engineer, PWD Bameng Division Veno
C/o Community transit camp 03 units at Tallo village under Bameng Circle
2024_PWDAP_1690_1
BMGD/DRG-40/SIDF/ 2023-24/03
Open Tender
Civil Works - Building
Item Rate
365 days
Tallo Village
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
EE PWD Bameng Division Veno
₹97,620
O/o the EE PWD Bameng Division Veno
27 Feb 2024
20 Feb 2024
27 Feb 2024
20 Feb 2024
26 Feb 2024
20 Feb 2024
21 Feb 2024
Amount
Sh:- Earth Work
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete
Sh:- Cement Concrete Work
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Sh:- RCC Work
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. (a) M 20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. (A) M20 ( 1Cement : 1.5 Coarse sand :3 Stone Aggerate 20 mm nominal size.)
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cementmortar1:3 (1cement: 3finesand) ofthickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1cement:1.5coarsesand:3stoneaggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete (a)Tar/TMT steel
Centring and shuttering including strutting, propping etc and removal of form work for
a) Foundation footings
b) Column, pillars, posts and struts etc.
c) Lintels, beams, girders, bressumers and cantilevers etc
d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height)
Sh:- Brick Work
Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
Extra for half brick masonry in superstructure above plinth level and up to floor two level.
Sh:- Wood Work
Providing approved best available local wood (Class- BII) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position
Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
Providing and fixing best available local wood glazed shutters for doors, windows and clerestory window using7.5kg/Sq.m .(3mm thick glass panes) including black enamelled MS butt hinges with necessary screws. a) 35 mm thick
Providing and fixing 30 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors,windows and clerestory windows including bright finished or and black enamelled iron wire butt hinges with necessary screws ( a) 2nd class approved local wood class - B I.
Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nuts and screws etc complete.
Providing and fixing MS tower bolts (barrel type) with necessary screws etc complete
Providing and fixing MS handles with necessary screws etc complete.
Providing and fixing MS hooks & Eyes. (b) 250mm
Sh:- Steel Work
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round barswith roundheaded boltsand nuts or by screws. (Plain grills)
Providing and fixing 40x3mm flat iron hold fasts 40cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x 15cm in1:3:6(1cement:3sand: 6hard stone chips 40 mm nominal size).
Providing and fixing MS fan clamp type I of 16mm dia MS bar bent to shape with hooked ends in RCCslabs during laying including painting the exposed portion of loop all as per standard design complete.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
Providing and fixing bolts up to 300 mm in length including nuts and washers complete.
Sh:- Cement Concrete Flooring
Cement concrete flooring1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. 40mm thick.
Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor a) 18 mm thick
Sh: Roofing
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. b) 0.63 mm thick GI sheet
Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. b) 0.63 mm thick GI sheet
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
Extra for making chamfered edges of beading
Sh:- Finishing
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
Neat cement punning.
White washing with whiting on new work (three or more coats) to give even shade.
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Sh:- Sanitary Work
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required
a) Long Pan patten WC Pan
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.
Sh:- Water Supply
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).
15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work)..
20 mm nominal bore
Providing and fixing brass bib cock of approved quality.
Providing and fixing brass stop cock of approved quality.
Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.
a) 100 mm dia
Providing and fixing kitchen sink including making all connection excluding cost of fittings.
a) White glazed fire clay sink size 600x450x150 mm
Sh:- Drainage
Construction of cement concrete drain 15cm wide and15cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40mm and downgauge) 8cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes
Providing and laying cement concrete 1: 5: 10 (1 cement: 5limesand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipes
Constructing brick masonry manhole with 2nd class bricks in cemen tmortar1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand :4stone single 20mm nomina lsize), foundation concrete1:4: 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete1:2:4mix(1cement:2coarse sand:4stone aggregate 20 mm nominal size) neatly finished complete as per standard design.
a)Insidesize90x80cmand45cmdeepincludingCIcoverwithframe (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg)
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
Sh:- Miscellanious Works
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Internal electrification
External electrification
SH:- Providing furniture & crockery Items
Wooden coats of size-(6'6"x5')=
Wooden Center table (1070x530x350)
Plastic Armed Chair
Crockery Items
Mattress kurlon Deluxe
Al Water Filter 3 Ltr.
Blanket
Pillow with cover
Bedsheet
Door and Window curtains
SH : Boundary Wall
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders up to 30 cm size, lift up to 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
a) Foundations and plinth :
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Providing and laying up to floor two level RCC string courses, coping bed plates, anchor blocks, plain window sills and the like including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface including centering and shuttering etc but excluding cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation, footings, bases of columns etc.
a) Column, pillars, posts and struts etc.
b) Lintels, beams, girders, bressumers and cantilevers etc.
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
Reinforcement of RCC work including bending, binding and placing in position complete.
b) Tar/ TMT steel
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
Extra for half brick masonry in superstructure above plinth level and up to floor two level.
12 mm cement plaster 1 : 6 (1 cement : 6 fine sand) .
15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall.
Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.
b) In Tees, Angles and Channels
Providing and fixing Mild steel Barbed wire
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Earth work in excavation in foundation and trenches in Soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 Cm layers when required into Plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and thendisposing of all surplus excavated soil as directed within a lead of 50 m.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
a) Foundations and plinth :
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation, footings, bases of columns etc. and mass concrete.
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height)
d) Column, pillars, posts and struts etc.
Reinforcement of RCC work including bending, binding and placing in position complete.
a)Tar/ TMT steel
Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.
b) In Tees, Angles and Channels
White washing with lime on new work (two or more coats) to give an even shade.
MS- Gate
M/S G B GROUPS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .