| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.7 LAdmitted-Finance 04 SUDARSHNA COOLING CENTRE ADP ROAD CHRISTIANPATTY NAGAON ASSAM 782001 UDYAM AS 22 0000781 | NAGAON | ASSAM | 782001 | -28.52% | ₹6.7 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
₹9.4 L
EMD Value
₹18,715
Closing Date
1 Dec 2025, 3:00 pmClosed
AGM EM
FCI RO Dimapur
SITC of Industrial 3Phase and 1Phase Sockets at FSD Dimapur and 1Phase Sockets at FSD Tuensang and FSD Mon for Moveable Conveyor Belt for mandatory mechanization of Loading and unloading operation
2025_FCI_886671_1
EM/Engg/NIT/01/DMV/2025-26
Open Tender
Electrical Works
60 days
DIMAPUR NAGALAND
Please refer to Tender Documents
11 documents required · 11 mandatory
₹0
₹18,715
2 Feb 2026
21 Nov 2025
2 Dec 2025
21 Nov 2025
1 Dec 2025
21 Nov 2025
Supplying and fixing 4 way (4 + 12), Double door prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Four pole, (Three phase and neutral), 240 V, 25A residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of of following sizes confirming to IS:7098(Part 1) 1988 with up to date ammendment as required.
4X16 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size up to 35 sqmm on wall / pole / steel structure surface as required. (Clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade at over head with 8 SWG dia GI wire, Shackle insulator, clamp, nut bolt cable clips etc as required. Upto 35 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for follwing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (4 X 16 sqmm)
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required. (Earthing for Industrial Sockets at FSD Dimapur, Mon, Tuensang)
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B (in points) at Dimapur Canteen.
Supplying of Swing wall fan, Elegant Look, High Air delivery,Smooth Oscilation, 57W, Speed 130/min, Air Delivery 65 m2/min, Pull Code for Speed and Oscilation, Swing Wall fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, Grey Colour, Sweep 400mm. copper winding, Powerfactor not less than 0.9, 350 RPM , suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (3 x 4 sq. mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Powerfactor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing module plate switch box including connection but excluding modular plate etc as required
20 W Surface mounting General Purpose Aluminium Battens with best in class Luminaire Efficacy. These Extruded Aluminium housing battens are equipped with high specifications CISPR 15 compliant Electronics driver and Milky white, special polycarbonate diffuser, for glare free efficient light distribution. THD: <10%
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, 25A residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Double Pole(DP) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 8 way ,Double door ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
Tendernotice_2.pdf
PDF • 0.93 MB
BOQ_932020.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid