Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35 LAccepted-AOC BAZAR RAM SUKH DASS FEROZEPUR CITY 152002 | FIROZEPUR | PUNJAB | 152002 | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹35.0 L+₹2.3 L (7.12%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹35.9 L+₹3.2 L (9.89%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹40.0 L+₹7.3 L (22.3%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹41.1 L+₹8.4 L (25.9%)Rejected-Finance OLD PULL MADIYA JAIRAMPUR AZAMGARH AZAMGARH UTTAR PRADESH 276001 | AZAMGARH | UTTAR PRADESH | 276001 | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE WEST FEROZEPUR CANTT
GE WEST FEROZEPUR CANTT
MISC REPAIR TO EXTERNAL ELECTRIC SUPPLY AT AD PATTI HUSSANIWALA HARIKE AND BOTH SOLAR PLANTS UNDER AGE EM OF GE WEST FEROZEPUR CANTT
2022_MES_524087_2
802022/GE-51/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST FEROZEPUR CANTT
₹70,000
Yes
22 Aug 2022
28 Jun 2022
21 Jul 2022
28 Jun 2022
19 Jul 2022
12 Jul 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layrs not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and dpositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable aftger laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L sub class B bricks locally available of size 22 x 11.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable
M&L in replacement of 80 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint and taking down complete all as specified and as directed.
M & L in replacement of pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers & one galvanized iron nuts, 100 mm height, 65 mm dia for 1100 volts grade complete after dismantling & taking out old U/s and directed.
M&L in replacement of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape of size as dircted inclusive of 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M & L in replacement of MCCB adjustable thermal & fixed magnetic setting type 200 Amps 4 pole of breaking capacity 25 to 36 KA 415 volt after and including taking down of unserviceable one complete all as directed.
M & L in replacement MCCB adjustable thermal & fixed magnetic setting type 250 Amps 4 pole of breaking capacity 25to36 KA 415 volt after and including taking down of unserviceable one complete all as directed.
M & L in replacement MCCB adjustable thermal & fixed magnetic setting type 100 Amps 4 pole of breaking capacity 25 KA 415 volt after and including taking down of unserviceable one complete all as directed.
M & L MCCB in replacement of adjustable thermal & fixed magnetic setting type 125 Amps 4 pole of breaking capacity 25 KA 415 volt after and including taking down of unserviceable one complete all as directed.
S&F in replacement of Changeover Four pole 100 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified.
Supplying and fixing in replacement of 1100 volts 16 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supplying and fixing in replacement of 1100 volts 10 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supplying and fixing in replacement of 1100 volts 6 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supply,Laying, testing in replacement of UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 95 sqmm 3.5 core complete all as specified..
Supply,Laying, testing in replacement of UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 50 sqmm 3.5 core complete all as specified..
Supply,Laying, testing in replacement of UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 sqmm 4 core complete all as specified.
Supply,Laying, testing in replacement of UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 10 sqmm 4 core complete all as specified. (Note for Srl item No 16,17,18,19 & 20 : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
M&L in replacement of XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross sectional area 95 Sqmm 3 Core including taking out old cable complete all as specified. (Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
All as per item no. 21 but of size 185 Sqmm 3 Core
All as per item no. 21 but of size 240 Sqmm 3 Core
All as per item no. 21 but of size 300 Sqmm 3 Core
S&F in replacement of Cable jointing kit for 11000 V (Earthed) gradecable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core complete all as specified and directed.
All as per item no. 25 but of size 185 Sqmm
All as per item no. 25 but of size 240 Sqmm - 300 Sqmm
S&F in replacement of Cable jointing kit for 11000 V (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
All as per item no. 28 but of size 185 Sqmm
All as per item no. 28 but of size 240 Sqmm - 300 Sqmm
Taking out and Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4mm diameter earth lead by means of nuts bolts check nuts & washers of GI with earth strip protected by galvanised iron pipe 15mm bore (Medium grade) for poles/lightening arrestors/GO Switch including connecting to LT overhead lines all as directed including concrete pit with PCC (1:3:6) type CI, precast RCC(1:2:4) type B-1 cover slab of size 54x54x50cm thick reinforced with 8mm hard drawn steel wire fabricated weighting exc 4 Kg/sqm with one handl e for lifting made out of 8 mm diameter MS bar finnel wiere mesh 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke andsalt in alternate layers including necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completeion all complete as specified and as directed.
Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 mtr/11 mtr pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed. Note : Spare parts will be measured and paid separtely.
(a) Supply only LED driver 240Volt 50Hz for upto 25 watt LED fittings.
(b) Supply only LED driver 240Volt 50Hz for 40 to 48 watt LED fittings.
(c) Supply only LED driver 240Volt 50Hz for 60 to 90 watt LED fittings.
M&L for Painting to steel tubular pole with existing paint and including cross arms upto 11 mtr long (except planting depth /PCC coping) with including one coats aluminum paint including preparation of old painted surface & Numbering of poles complete all as specified and directed .
M&L for Painting of LT PCC pole upto 1.5 mtr height from PCC, of synthetic enamel paint over a coat of cement primer with black and white strips with aluminum paint on pole & Numbering of poles all as specified and directed .
S&F GI Bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto 1.2 mtr long etc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed.
S&F GI Bracket for street light fitting bend to shape made out of GI pipe light grade 20 mm bore upto 1.2 mtr long etc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed.
M & L in replacement of wiring for circuit/street light connection with FRLS PVC insulated Copper conductor sigle core cable in surface/recessed in PVC conduit of suitable size 2x2.5 sqmm+ 1x1.5 sqmm earth wire as continous earthing complete all as directed. Note : Two run 2.5 Sq mm of cable shall be measured as single run.
Taking down of the UNSV/ defective transformers of capacity 75 KVA (out door/Indoor type) from the existing site located in cantt area after disconnecting the in/out connection, transporting the transformers to workshop/factory for repairs,testing and transporting the same back after repairs and installing, hoisting of transformers on two/four pole structure at height not less than 3 metre, making all electric connections with HT/LT side jumpers and leads including earth connections etc and testing, complete all as specified and directed. Note:- (a) Oil container for collecting old transformer oil will be arranged by the contractor (b) The T&P such as chain pulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor.
Taking down of the UNSV/ defective transformers of capacity 100 KVA (out door/Indoor type) from the existing site located in cantt area after disconnecting the in/out connection, transporting the transformers to workshop/factory for repairs,testing and transporting the same back after repairs and installing, hoisting of transformers on two/four pole structure at height not less than 3 metre, making all electric connections with HT/LT side jumpers and leads including earth connections etc and testing, complete all as specified and directed. Note:- (a) Oil container for collecting old transformer oil will be arranged by the contractor (b) The T&P such as chain pulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor.
M & L for opening the top of defective transformer of any make and capacity 100 KVA removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking out defective/ unserviceable coil for check after disconnecting all connections and re-assembling of core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of U/S parts including cleaning the tank, removing sludge, dirt cleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromate paint inside , replacement of nuts bolts with washers thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workshop to the entire satisfaction of Engineer-in-Charge complete all as directed and as specified. Including the following from Srl No a to c. (a) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified. (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified. (c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified. Note:- (a) The payments of new coils , Brass Spindle , Silica Gel Breather and other parts to be replaced shall be is included in item rate quoted by contractor. (b) Transformer Oil Dehydration and Topping up will be measure and paid Seperately after repair of Transformers
M & L for opening the top of defective transformer of any make and capacity 75 KVA removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking out defective/ unserviceable coil for check after disconnecting all connections and re-assembling of core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of U/S parts including cleaning the tank, removing sludge, dirt cleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromate paint inside , replacement of nuts bolts with washers thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workshop to the entire satisfaction of Engineer-in-Charge complete all as directed and as specified.(including the following ) (a) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified. (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified. (c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified. Note:- (a) The payments of new coils , Brass Spindle , Silica Gel Breather and other parts to be replaced shall be is included in item rate quoted by contractor. (b) Transformer Oil Dehydration and Topping up will be measure and paid Seperately after repair of Transformers
M&L for Replacement of LT brass spindles, nuts, bolts, washers for transformers of capacvity 75 KVA to 100 KVA complete all as specified.
M&L for Replacement of LT bushing porcelain capacity 75 KVA to 100 KVA complete with gasket set all as specified
Supply and fixing in repair CRGO silicon core as per existing thickness, size & design for transformer 75 KVA to 100 KVA complete all as specified.
Supply and fixing in repair Top cover gasket set complete & specified.of 8 mm thicknes ISI marked complete all as specified and directed.
M&L for Opening ,draining of oil ,stoppage of leakage ,change of gasket set complete HV/LV rods at site refilling of transformer oil complete all as directed by Engr-in-charge capacity 75 KVA .
Supply & Fix in replacement of silica gel breathers assembly filled with silica gel complete for transformers of capacity 75 KVA complete all as specified.
Supply & Fix in replacement of temperature gauge 0 to 300 degree centgrade for transformers of capacity 75 KVA complete all as specified.
M&L for Supply and pouring/ top up of New Transformer oil for Distribution Transformer Oil (as per IS 335) (EHV) of dielectric strenght min 45 KV in company sealed packed drum.
Material and labour for Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 75 KVA to 100 KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM number with white paint over black base in letters not less than 10 cms in height complete all as specified and as directed.NOTE :- Painting shall be carried out at site.
Material and labour for removing old paint by paint removers and painting to existing outer & inner surcface of LT Control Panel of any size by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below of make Burger/Asian/Nerolac of first quality , all as specified and directed by Engr-in-Charge. (i) LT Control Panel (Outer & Inner Surface) - Dark Grey
Carrying out servicing/maint of 30 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
Supply only lubrication oil SAE-40 ( 15 W- 40 grade) of Make: Valvoline or HP Milcy Super 20W 40, all as specified and directed. Make: HP/Servo/Gulf.
Supply and filling of inhibitor corrosion (Coolant) suitable for radiators of 30 KVA capacity DG set complete all as specified and directed.
Supply and fixing in replacement Lub oil filter complete set. Make: Kirloskar/ Micco/Bosch
Supply and fixing in replacement Diesel filter complete set. Make: Kirloskar/ Micco/Bosch
Supply and fixing in replacement Air Filter as per sample
Supply and fixing in replacement Hose pipe & Flexible pipe complete set.
Supply and fixing in replacement Fan belt for water pump
Supply and fixing in replacement Fan belt for alternator dynamo
S&F in repair lead acid battery capacity of 80 AH, 12 volts for DG sets installed on pump house. Make:- Exide Express/Amron/Luminous
Supply & Fixing for replacement of Battery charger (UPS) upto 250 AH, 12 Volts, single Phase AC supply 230V, 50 Hz including all type indicators, showing charging all as specified and directed by Engr-in-charge. Make :Luminous/ Microtek or equivalent.
Taking down copper/aluminium point wiring (light, fan,socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking of credit and making good disturbed surfaces of walls, floors etc.
Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
Material & labour for concealed/Surface conduit point wiring complete with 1.5 Sqmm (nominal cross sectional area) FRLS PVC insulated multistranded copper conductor cable in and including heavy duty PVC conduit pipe with wall thickness 2 mm minimum (ISI marked) including fittings & accessories with MS concealed terminal boxes made of 2 mm thick MS sheet with 3mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 Sqmm FRLS PVC copper conductor cable multi-stranded in green colour code as earth wire connected to the common earth dolly as specified for the following (a) One light point/ fan point/ exhaust fan point controlled by one switch
(b) One three pin socket outlet 5 Amp on same board
(c) One three pin socket outlet 5 Amp on independent board.
All as per description of Srl Item No. 65 above but with 2.5 Sqmm cable and 2.5 Sqmm copper conductor cable in green colour code as earth wire for 15 Amp socket outlet complete controlled by one switch.Note:- Socket /switch shall be measured and paid for separately
Supply & fixing socket outlet flush type 2-in-1, multipurpose, 3 pin 5 Amp and 2 pin 5 Amp and 2 pin 5 Amp complete all as specified.
Supply & fixing switch socket outlet flush type 2 in 1, multipurpose 3 pin 5 Amp and 3 pin 15 Amp 240 volts compete all as specified
S &F Switch piano, flush type single pole, one way, 230 Volts, 5 Amps complete all as specified and directed.
Supply & Fixing sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series TPN DBs (Vertical type)fitted with ABS frame and 415 volts 200 Amps rated enameled bus bar 4 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified
Supply and fixing in repair sheet metal enclosures single phase single door flush to wall fitted with bus bar and neutral link for MCB (without MCB's) 8 ways SPN complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 32 amp rating 240V, 10KA 'C' curve SPN miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply & Fixing ceiling rose,PVC/Polycarbonate,isolated three terminals.
Supply & Fixing Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings.
Supply & Fixing step type regulator Piano switch type ( 5 step) for ceiling fan 1200/1400 mm size 230 volts, 6 Amps.
M & L in repair for sub main wiring with two single core PVC insulated FRLS cable with Copper conductor unsheathed cable of size 2 x 6 sqmm drawn through in and including PVC casing / capping with 1 x 6 sqmm PVC insulated copper conductor single core for continuous earthing complete ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0 Sqmm and one run of 6.0 Sqmm PVC insulated copper conductor single core,one run of PVC casing capping shall be measured as single run)
Supply & Fixing in replacement of LED tube light fitting 18 Watts,4 feet long decorative ultra slim linear LED lighting fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and laying in replacement of pipe galvanized, “Medium class”, including fittings 80 mm dia.
Supply and laying in replacement of pipe galvanized, “Medium class”, including fittings 50 mm dia.
Supply and laying in replacement of pipe galvanized, “Medium class”, including fittings 25 mm dia.
Supply and laying in replacement of pipe galvanized, “Medium class”, including fittings 20 mm dia.
Supply and laying in replacement of supply and fix Valves, Sluice, flanged type of class 1.6 PN,100 mm (4”)dia
Supply and fix in replacement of Valves, Sluice, flanged type of class 1.6 PN, 80 mm (3”)dia
Supply and fix in replacement of gate valve conforming to IS 9338 ,50mm (2”) dia pipe
Supply and fix in replacement of gate valve conforming to IS 9338,25 mm (1”) dia pipe
M&L in replacement of Gun metal gate valve ISI marked with Iron wheel head, screwed both ends for iron pipe or for socket or union for 20 mm bore pipe including taking down existing gate valve in existing transformers of any capacity complete all as specified ISI marked
All as per srl item No 93 here-in-before but for 25 mm bore pipe
Supply and fixing in replacement of LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed. Make - Cropmton/Havells/Bajaj/Philips
Supply and fixing in replacement of LED Street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed. Make - Cropmton/Havells/Bajaj/Philips
Supply and fixing in replacement of automatic street light switch for automatic swithcing of street light/high mast light (timer switch) for Three Phase Load light. The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1 , including incoming & outgoing MCBs,SMC Encloser and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof , shock & termite proof and FRLS grade confirming to IP 54 of capacity 6 KW, Three phase, Contactor rating 32/TP and MCB rating 40Amp TPN, having Facility of manual operation. Make- HAVELLS (model - IHXTS03060 or quivalent model of Swdeep/Hansel/Havells)
Supply and fixing in replacement of automatic street light switch for automatic swithcing of street light/high mast light (timer switch) for Three Phase Load light. The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1 , including incoming & outgoing MCBs,SMC Encloser and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof , shock & termite proof and FRLS grade confirming to IP 54 of capacity 12 KW, Three phase, Contactor rating 65/TP and MCB rating 63 Amp TPN, having Facility of manual operation. Make- HAVELLS (model - IHXTS091020 or quivalent model of Swdeep/Hansel/Havells)
Pump House/Electrical Installation Cleaning /Site clearence by cutting and removing shrubs, vegetation , grass , bush , weed , trees and saplings of any height up to the ground clearence.around water supply installation as directed at site by Engr-in-charge. Note :- i. The rates quoted includes stacking of useful material and dispose off rubbish / useless material up to a distance of 50 mtr out side the periphery of the installation. ii. Pump house area include the complete OHT area, pump house area and connected path way between pump house and OHT.
Supplying and laying un-reinforced precast concrete cable cover,class HV, Type 1, flat, size 300mmx l80mm x 40mm
Cement concreted (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified and directed.
Cement concreted (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
Cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
Supply and fixing LT Pre-stressed concrete pole 9.0 metres long of cross section 102 mm x 152 mm at top and 102 mm x 289 mm at bottom class 10 complying with requirement of IS 1678-1978 incl painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtr height from top of PCC as directed (PCC and earth work shall be measured and paid separately). complete all as specified and directed
Dehydration/ filtration of transformer oil of existing transformers (outddor/ indoor, step down) at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/ sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minimum dielectric strength of 45 KV by continuous process of dehydration complete including testing all as directed and as specified. (Testing machine shall be arranged by Contractor.)
M&L Air break gang operated switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, vertically mounted, (12 insulator type) mounted on insulator and steel frame with operating mechanism in accordance with IS-9921 including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps 11000 V with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position of required size including two coats of aluminum paint over a coat of red oxide complete all as specified.
M&LLightening arrestor expulsion type for outdoor suitable for 11 KV high tension line complete with all fittings with discharge capacity 65 Kilo amperes, including bracket clamps, nuts, bolts & washers and connection to earth wire & SWG GI wire of 4mm size complete all as specified (Make Pactil/Atlas/ Southem insulator/Jaipuria).
Shifting of transformer to a distance from AGE E/M West/any other place to required place, including disconneting and necessary connection and testing after shifting complete all as directed.
M&L for pinpointing of 11000 V underground cable fault of any size with help of cable fault locating machine (CFL Machine) consisting of DC Testing,Thumping system and DIGI point Sensor complete to locate the exact fault location (1'st fault) all as specified.
Supply and fixing in replacement of MC-04 Connector (Male / Female type) complete all as specified and directed.
Supply and fixing in replacement of 'Y' Connector (Male/ Female type) complete all as specified and directed.
Supply and fixing in replacement of 4 Sqmm Copper Lugs (Male / Female type) complete all as specified and directed.
Supply and fixing in repair 4 Sqmm DC copper cable Make : Polycab complete all as specified and directed.
Supply and fixing in replacement of Fuse (Small fuse 1000 Vdc/ 30A complete all as specified and directed.
Supply and fixing in replacement of RJ 45 Connector complete all as specified and directed.
Supply and fixing in replacement of Cat-6 Sheilded cable (D-link) complete all as specified and directed.
Supply and fixing in replacement of Citel RS-485 SPD pluggable complete all as specified and directed.
Supply and fixing in replacement of Phoerix contact plugaable SPD complete all as specified and directed.
Supply and fixing in replacement of water pressure pipe flexible type ( with inner stainless steel Ring) complete all as specified and directed.
Supply and fixing in replacement of Solar Panel cleaning kit - 3 neter water fed Solar Cleaning kit with Nylon Brush & Extension pole complete all as specified and directed.
Supply and fixing in replacement of Water Fed pole kit, Solar panel cleaner complete with 7 Mtr pole, Hose Spray Washer & Scrubber Brush complete all as specified and directed.
B.L. Chaudhri and Co.
R.S.ENTERPRISES
DHAWAN CONSTRUCTION COMPANY
ABHISHEK AND COMPANY
Manjeet Singh Contractor
shivam builders
M/s Mukand Lal Khanna
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .