| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹43.1 L+₹52,685 (1.24%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹45.1 L+₹2.5 L (5.78%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Tampered GST Registration Certificate uploaded | |
| 5 | Rejected-Technical H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | - | Rejected-Technical NO in WLR in QE June 2022issued by Western Command |
Tender Value
₹49.8 L
EMD Value
₹1 L
Closing Date
7 Nov 2022, 6:00 pmClosed
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REROUTING/SHIFTING OF HT/LT CABLES AND REPLACEMENT OF LT PANELS AT SIGNAL ENCLAVE APS AREA ALONGWITH OF CONNECTED ITEMS OF AGE (U) ELECT SUPPLY NO III UNDER GE (U) ELECT SUPPLY, DELHI CANTT10
2022_MES_542135_2
GE ELECT/D-55/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
12 Dec 2022
19 Oct 2022
9 Nov 2022
19 Oct 2022
7 Nov 2022
26 Oct 2022
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in Soft soil for laying of cables or GI pipe and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supply and laying in replacement unreinforced precast concrete cable covers class HV Type -1 with peak size 300 x 180 x 40 mm. compete all as specified and directed
All as per srl item No 3 here-in-before but using old tiles obtained under srl item No 1 all as specified and directed by Engineer- in- Charge..
Returning filling in. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Supplying laying Class LV tiles, type 1, for 1.1 KV flat size 250mm x 150 mm x 40mm all as specified and directed by Engineer-in-Charge..
Taking down/up existing HT unserviceable cable of any size from trench/pole etc all as specified and directed.
Labour and T&P only for relaying the HT cables of size 300 sqmm 3 core 11 KV in any position all as directed by engr - in - charge. detail as bellows :- (a) (Signal Enclave to near IGL pipe line cassel road)-275 RM (b) Near Rangshala area-200 RM
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) of size 300 sqmm x 3 core with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, laid in trenches fixed to pole, including jointing & testing complete all as specified. (a) One run (1x675=675 RM) from Signal Encalve to near IGL pipe line cassel road . (b) One Run (1x350 =350 RM) near Rangshala area Note: Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
M&L for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 04 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm.
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded after taking out/down old existing unserviceable from trenches / ducks/ road crossing and poles complete all as specified and directed of following size
3.5 core, 50 sqmm.
3.5 core, 35 sqmm.
3.5 core, 25 sqmm.
4 core, 16 sqmm.
Taking out old street light fittings and supply and fixing of new generation energy saving and environment friendly long life verasalite pressure die- cast aluminium IP 65 road way luminare with high power LEDs of 60 Watts capacity as light source and exclusively designed for poly carbonate cover with electronic drive.along with 1.5mtr bend pipe necessary wiring and clamps for fixing on all as specified and directed
M&L in replacement for service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed.
Taking out old damage LT pole and Supplying, Errection & Fixing Steel Tubular swan neck pole 410 SP-31 (09 metres long) including PCC (1:3:6) & (1:2:4) for copling Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint complete with cast iron base plate all as specified.(Note : Excavation earth work may be paid separatly of respective items.)
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size size 50 mm dia complete all as specified and as directed .
All as per item No 16 here in before but of size 80 mm dia complete all as specified and as directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I of 2009, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm
Supply, jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core 300 Sqmm.
M&L for Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, for the top 100mm layer, complete all as specified and directed.
Supply and fix in replacement of cable route indicator made of RCC with 8 mm TMT size 1.5 M height x 60 cm wide x 10 mm thick tapered on top visible above ground duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 11kv will be given by Engr-in-charge complete all as specified and directed.
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).( Location: Old APS)
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
Outgoing :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 63 Amps. - 09 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Location:5 Signal Group)
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
(b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 160 Amps. - 03 Nos (ii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 03 Nos (iii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (v) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (vi) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vii) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (viii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Location:5 Signal Group)
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
(b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 160 Amps. - 02 Nos (ii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 03 Nos (iii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (v) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (vi) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vii) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (viii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).(Location:1 Signal Office Block)
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
(b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 160 Amps. - 04 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Location:New APS).
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
(b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 250 Amps. - 01 Nos (ii) MCCB 4 pole 415 V breaking cap 25 KA , current rating 160 Amps. - 01 Nos (iii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 01 Nos (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint .(vi) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (vii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (viii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).(Location Near Signal Enclave Power House.)
(a) Incoming :- (i) Incomer of the panel having ACB 4 pole , 630 Amps,50 Hz,415 Volts, with Thermal Magnetic Release (Manual Fixed type) - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
(b) Outgoing :-(i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 250 Amps. - 01 Nos (ii) MCCB 4 pole 415 V breaking cap 25 KA , current rating 200 Amps. - 01 Nos (iii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 01 Nos (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint . (vi) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (vii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (viii) Indicating Lamps R Y B , LED type-01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).( Location: 1 CPBO)
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 600 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set
Outgoing :-(i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 100 Amps. - 08 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vii) Indicating Lamps R Y B , LED type01 set
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
SB ENTERPRISES
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .