Executive Engineer R.M. Division BBMB Talwara
Executive Engineer R.M. Division BBMB Talwara Sector 2
Renovation of the buildings of BBMB 66 KV and11 KV sub station at Beas Dam site and 33 kv Sub station at Sansarpur Terrace
2023_BBMB_172297_1
DNIT10/2023-24
Open Tender
Civil Works
Item Rate
60 days
Pong Dam site
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
Accounts Officer Cash BBMB Talwara
₹17,748
11 Dec 2023
28 Oct 2023
6 Dec 2023
28 Oct 2023
5 Dec 2023
28 Oct 2023
Amount
Removing Doors and windows (steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. (a) Doors of area 3sqm and below.(CSR-8.26)(a)
Removing Doors and windows (steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. (b) windows of area 3sqm and below.(CSR-8.26)(b)
Aluminium frame 100m x 45mm providing and fixing.
Aluminium window and door 80mm x30mm providing and fixing.
Glass providing and fixing 5mm
Steel Jail providing and fixing.
Crib From jail and glass fixing
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. Complete. I.S.I Designation No. III (size of door 851mm to 1000mm)(CSR-17.43)(c )
Appling priming coat with metal primer on new steel or iron work including preparation of surface.(CSR-16.20)
Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.(CSR-16.21)A&C
Nicking cement concrete surface (over 28 days old including preparation and laying slurry.(CSR-10.31)
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to bespecified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 600x600 mm(CSR-14.113)(a) A&C 2
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.(CSR-14.72)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(CSR-14.126)
Scraping (a) white wash and colour wash.(CSR-8.31)(a)
Preparation of Plastered surface for distempering including surface applying filling with approved quality filler consisting of plaster of Paris and chalk Mitti including finishing the surface to the required finish complete.(CSR ITEM No-16.6)
Distempering with Acrylic washable oil bound distemper(of approved manufacture) two coats over one priming coat to give an even shade.(CSR ITEM No-16.11)A&C 1
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacemetc.two or more coats to give an even shade.(CSR-16.13)A&C 1
12.5 mm thick cement plaster 1:4. CSR 15.9)
Providing and laying 80 mm thick factory made cement concrete interlocking Paving blocks of M-40 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.(CSR-14.139)
Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and and down pipes.(CSR Item-8.11)
Corrugated GI Sheet roofing 0.80mm thick fixed with galvanized iron J or L hooks 10mm dia, GI Limpot and bitumen washers complete excluding the cost of purling rafters and trusses.(CSR ITEM-13.18)
GI Sheet gutters 0.80mm thick semicircluar 15cm diametre including fixing with clamps and making connections with rain water pipes. (CSR ITEM NO-13.22)
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mmlong dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.(CSR-13.64) A&C4
Dismantling Sanitary fixtures such as Eurpoean/ Indian/Orissa W.C., PVC/ China warecistern, Wash Hand Basin, Urinal Pot, Sinks andCP Fittings and disposal of dismantled materialwithin a distance of 100 Mtr. complete in allrespect as required by Engineer-in-Charge. Eurpoean/Indian/Orissa W.C.(CSR-30.88)(a)
Providing and fixing in position ChinawareIndianOrisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVCflushing cistern ISI makred including cost ofPVC long bend 32 mm dia complete in allrespect and to the entire satisfaction of Engineer-in-charge.(CSR-30.2)
Extra for providing and fixing C.P. Brass longflush bend 32mm instead of PVC long bend. .(CSR-30.7)(C)
Providing and fixing in position vitreous chinaware white lavatory suites of approvedmake (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm longwithout CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm.(CSR-30.31)(ii)
Providing and fixing in position C.P. BrassAuto close Pillar Cock of approved make (tothe approval of Engineer-in-charge)(CSR-30.34)
Providing & Fixing in position 5mm thickbevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 600mmx450mm.(CSR-30.61)
Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.C.P. brass towel Rails size 15mm dia610mm long.(CSR-30.58)(a)
LED Light
REPLACEMENT OF WIRES, COVER FRAMES,MODULAR SWITCHES, CONCEALED METALBOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPEACCESSORIES) Derived from 34.01: Replacement of PVC insulated copperconductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laidin existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked,recessed in wall etc., complete with powdercoated/anodized concealed metal boxes(1.6mm thick with Brass lugs) required forsuitable number of modules (Modularaccessories) for having Step type electronicfan regulators (two module) 100watts, bellpush, 6Amp. 2/3 universal socket (shuttered),16/20Amp. combined/ universal Socket(Shuttered), 6/10Amp. Switches, 16/20Amp.switches with indicator etc. and covered withFrame Plate etc., PVC connector (For FanBox and Call Bell), PVC Bush, bonding toearth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm,1100volts grade (For 6Amp. wall socket &plug control point) and other petty materialetc. including the cost of above material,cutting and filling up of chases (withfinishing the surface):- (Derived From )aWiring fan point (Without fan box)CSR 34.01) CSR-34.08 (i)a
Wiring light point CSR34.01) CSR-34.08 (iib)
Wiring 6Amp. wall socket point CSR34.01) CSR-34.08 (iv)b
Wiring 16/20Amp. power plug control point CSR34.01) CSR-34.08 (vi)b
PVC INSULATED FR COPPER CONDUCTOR CABLES Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge Overall size 1.5sq.mm (Un-sheathed)(CSR-34.09) (ii)
Overall size 2.5sq.mm (Un-sheathed) CSR-34.09 (iii)
Overall size 4sq.mm (Un-sheathed) CSR-34.09 (iv)
PVC, HDPE PIPES & PVC FLEXIBLEPIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III &HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- (x) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) CSR-34.12
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB'sSupply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper bus bars, shrouded neutral bars, earth bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP& Ndistribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: TP&N Horizontal Double Door Distribution Board 12 way each -CSR-34.17 viii)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C):-CSR-34.16 (ii)
MCB Four Pole 50, 63amp. (10kA, Curve-C) xvi CSR-34.16 (xvi)
VISHAKH SOODEN GOVT CONTRACTOR
M/S EIGHT ARMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .