Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.9 LAccepted-AOC | 1 | Accepted-AOC Awarded | |
| 2 | 2₹9.9 L+₹2.9 L (40.9%)Rejected-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | 2 | Rejected-Finance 2nd lowest | |
| 3 | 3₹10.9 L+₹3.9 L (56.3%)Rejected-Finance | 3 | Rejected-Finance 3nd lowest | |
| 4 | 4₹11.4 L+₹4.4 L (63.1%)Rejected-Finance 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | 4 | Rejected-Finance 4th lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹11,400
Closing Date
26 Mar 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EWC
3-Civil Lines, Bareilly
Increasing capacity of 33/11 KV Sub-Staions in district Shahjahanpur - Rampur Kalan (2x5 MVA to 5plus10 MVA) and Gangsara (2x5 MVA to 5plus10 MVA)
2021_MVVNL_572577_1
34/EWC(B)/2020-21
Open Tender
Electrical Works
Fixed-rate
90 days
Shahjahanpur
As per tender document
3 documents required · 3 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹11,400
11 Feb 2022
18 Mar 2021
27 Mar 2021
18 Mar 2021
26 Mar 2021
18 Mar 2021
180 days
Amount
Part (A)
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
MS Channel 100x50mm @ 9.5 kg./mtr.
M.S.Angle 75x75x8mm @ 8.9 kg./mtr.
11 KV Cable 3x300 Sq. mm XLPE
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per as per details given below.
Providing of bore well type pipe earthing 5mtr. below the water level but minimum depth of pipe earthing should be 40 mtr. at T/F neutral, LA. & equipment stuctures by using Ist class GI Pipe (ISI Mark)of size 40 mm dia.(All the required materials will be provided by firm.)
Making of triangular bridge for above pipe earthing by using 32 mm dia round bar & GI strip of size 50x6 mm. (All the required materials will be provided by firm.)
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & will be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms.
Laying of 11KV cable of different size from power T/F to control room I/C and control room to outside D/P. 11 KV Cable will be layed in brick trench constructed below 750mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench as per RESPO norms.
Termination of 11 KV XLPE cable of size 3x300sqmm by 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer & 11 KV switch gear panels with suitable connectors. 11 KV cable boxes will be supplied by the Deparment & other material will be supplied by the contractor.
Safe removal of existing old 5 mva /8 mva 33/11 kv power transformer from plinth after disconnecting ht, lt, neutral earthing & wiring connections. draining out of transformer oil from transformer radiator and dismentalling of radiators. Proper placing & stacking of exisiting transformer to suitable place with in substation permises as per instruction of site incharge.
Safe carriage & commisioning (if required) of old & used 5 MVA transformer from site to other substation as per requirement :-
Safe loading & unloading of old & used 5 MVA Transformer with all accessories.
Rate for carriage (per km).
Placing the old & used 5 MVA transformer on the plinth, reassambling of transformer radiators, conservator & changing of all Gasket, testing after earthing of T/F neutral, HT/LT & wiring connection of old & used 5 MVA transformer
Centrifuging of transformer oil of old & used 5 MVA Transformer (if required).
Repairing of damage switchyard fencing.
Bharat Trading Corporation
M/S MEGHA ENTERPRISES
M/s Shubham Traders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .