Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 CrAccepted-AOC 723 27 SHIVAJINAGAR SUDHARSHAN NIWAS NEAR POLICE GROUND BARSHI SOLAPUR 413 411 | BARSHI | SOLAPUR | MAHARASHTRA | 413411 | ₹12.0 Cr Quoted ₹11.8 Cr | L1 | Accepted-AOC 1 st Lowest |
| 2 | L2₹12.8 CrRejected-AOC | ₹12.8 Cr | L2 | Rejected-AOC 2nd Lowest |
| 3 | Rejected-Technical PLOT NO 14 15 N 20 DYNA FILTERS PVT LTD PLOT NO 14 15 20 PUNE SOLAPUR RD HADAPSAR PUNE MAHARASHTRA 411028 UDYAM MH 26 0014110 27AACCD4903E1Z1 R M MII STATUS AS VERIFIED | PUNE | MAHARASHTRA | 411028 | - | - | Rejected-Technical As per report |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per report |
Tender Value
Refer Docs
EMD Value
₹10.4 L
Closing Date
2 Mar 2021, 3:00 pmClosed
Managing Director
Plot No.R-7, MarketYard, Gultekadi, Pune 411037
CW2 Up gradation and Expansion in the Existing MSAMB Facilities at Aurangabad and Latur Division and Erection of New Custard Apple Facility
2021_CMTAD_635105_1
MSAMB/ENGG/ADB/MAGNET/CW2
Open Tender
Civil Works - Others
365 days
Aurangabad and Latur Diviison
Civil and Electromechanical
work
3 documents required · 3 mandatory
₹3,540
₹10.4 L
Yes
Maharashtra State Agricultural Marketing Board
24 Sept 2021
12 Jan 2021
2 Mar 2021
12 Jan 2021
2 Mar 2021
4 Feb 2021
12 Jan 2021 - 21 Jan 2021
27 Jan 2021
Export Facility Center, Jalna, Dist. Jalna
PART A : Work Portion
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Spec.No. MORTH 201(S. S. R. I. No. 2.09 & P. No. 26)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 (S. S. R. I. No. 21.37 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.22 & P. No. 189)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.24 & P. No. 199)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (S. S. R. I. No. 25.33 & P. No. 225)
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (S. S. R. I. No. 25.52 & P. No. 227)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227) Note:- Waterproofing Chemical Added For Tarrace Slab Casting.
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.7, Page No.38 (S. S. R. I. No. 26.07 & P. No. 230)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & Page No. 231) Note:- Waterproofing Chemical Added For Water Tank Pardi Casting
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 221)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313.
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 29.05 & Page No. 251)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 255) For Toilet Blocks And Terrace
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick (S. S. R. I. No. 22.19 & Page No. 385)
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec .No. Bd. J.2 Page No. 355 (S. S. R. I. No. 31.13 & Page No. 258) For External Water Proofing
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.26 & Page No. 262)
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 260)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 262) For Water Tanks
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. (S. S. R. I. No. 32.11 & Page No. 261)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete Spec. No .BDM-22, Page No. 390 (S. S. R. I. No. 33.18 & Page No. 268)
Providing and laying Machine Cut Machine Polished Kota Stone Flooring 25 mm To 30 mm Thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.06 & Page No. 265)
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 35.21 & Page No. 282)
Providing and applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Spec. No. Bd.P.6 Page No.414. & Preapproval of Superintending Engineer. (S. S. R. I. No. 36.14 & Page No. 285)
Providing and applying Two Coats Of Exterior Acraylic Emulsion Paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. Spec. No. As directed by the engineer in charg. (S. S. R. I. No. 35.25 & Page No. 283)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.. Spec. No. Bd.O.5 Page No.405.(S. S. R. I. No. 35.07 & Page No. 286)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306)
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190)
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499. (S. S. R. I. No. 39.09 And Page No. 307) For Main Doors And Lab Doors
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317)
Providing and fixing mild steel grill work for windows, ventilators, etc. 20 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.. Spec. No. Bd.U.1 Page No. 537 (S. S. R. I. No. 40.01 And Page No. 329)
Providing and fixing during laying in R. C. C. Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 26.68 And Page No. 245)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thickat top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. 2019-20 I. No.40.07And Page No. 330) For Staircase
Providing and Fixing Magnetic Stopper of type Pvc, Bell Magnet, Heavy Metal, for doors with fixing, Screwing, fastening, etc complete. As directed by Engineer Incharge. Heavy Metal Type (Aurangabad D. S. R. 2015-16 I. No. 601 & P. N. 178)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) (S. S. R. 2019-20 I. No.39.24 And Page No. 318)
Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT-TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18mm thick Prelaminated particle board with PVC edge band as per drawing Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.21 & Page No. 460)
Providing & Arrangemnt of High Back Chair -TILT MECHANISM WITH MULTI LOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U. CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.41 & Page No. 466)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (S. S. R. I. No. 42.54 & Page No. 358)
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.57 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.58 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.59 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.60 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.55 & Page No. 358)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.37 & Page No. 355)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.36 & Page No. 355)
Painting letters upto 20cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. Spec. No. MORH 801 (S. S. R. I. No. 6.05 & Page No. 54)
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.87 & Page No. 363)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (S. S. R. I. No. 42.02 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. Class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.09 & Page No. 351)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" diax 25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with net lon mesh including 300mm thick side filling around out side of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. As directed by Engineer in charge (S. S. R. I. No. 48.47 & Page No. 405)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 23.01 & Page No. 223 )
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP ( For Panel, DBs, Building Earthing etc.)
Supplying & erecting G.I.Earth wire of high purity of different sizes used for earthing or any other purposes on wall with G.I.necessary clamps as fixed on wall/cable/conduit with screws in an approved manner ( From DBs to Earth bus and other small electrical appliances etc)
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6A/10A/16A/20A/25A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB(FOR CONVEYOR)
Supplying, erecting CRCA sheeet metal one way enclosures suitable forDP MCB/TP MCB/FP MCB erected on angle iron /GI frame complete (FOR CONVEYOR)
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB (FOR CONVEYOR)
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XPLE armoured cable 2 core 6 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (for ups)
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Supplying & laying HMS PVC conduit 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No.WG-MA/CC
Point wiring for light/fan/bell /exhaust fan Hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n caping with 1.5 sq.mm. (2+1E) FRLS grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Supplying & erecting modular type electronic dimmer 1000W 2 module ISI marked approved make duly erected on provided plate & box with wiring connections complete
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Point wiring for two way light points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for independent plug, concealed type in min 20mm PVC conduit with 1.5 sq.mm FRLSgrade copper wires with moduler type switch and socket and required accessaries as per specification No WG-PW/SW (OR CASING CAPPING)
Supplying & Erecting modular type 3 pin 6/16A multi socket with safety shutters combined unit ISI marked approved make duly erected on provided plate & box with wiring connections complete ( for AC 13)
Supplying and erecting modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. ( For 20A S/S Outlet)
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting ding dong/ electronic musical type call bell with heavy duty coil suitable to operate on 230V AC supply erected on polished double wooden block /sunmica block of suitable size
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying, and fixing Cat-6 LSZH CABLE suitable for LAN/WAN as per specifications complete
Supplying, installing, testing & commissioning approved type Push button telephone instrument desk top/wall mount with caller ID unit as per specification in approved manner
Supplying & erecting telephone cable 3 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 /15683 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying, erecting and testing optical type smoke detector complete on box as per specification No. FF-FAS/SD
Supplying, erecting, testing and commissioning Manual Call Point (Pill box) with break glass push button in metal enclosure complete as per specification No. FF-FAAS/MCP
Supply and erecting hooters with CRCA enclosure complete as per specification No.FF-FAAS/HTR
Supplying and erecting XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling as per specification No. CB-LT/CU
Supplying, erecting, testing and commissioning the 12 Zones Microprocessor based conventional Fire Alarm Control Panel (FACP) with standard accessories complete as per specification No. FF-FAAS/FACP
DOCK DOOR & SHELTER Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK SHELTER : Retractable type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Support structure to be included in the cost.Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
DOCK LEVELER Designed for Hydraulic operation in accordance of EN:1398 in steel construction as per General technical specification Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included.Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
Dock House Structure with suitable provision to install Dock Leveler, Dock Shelter & Motorised, Overhead Door Approx. Door House Size: Width 3400mm x Length 2600mm x Height 5450mm Self-contained loading bay to be installed in front of the ante-room/loading unloading passage. The design and layout of the dock house shall be adapted to suit the requirements of the site. Steel dock comprising of supporting legs.,Collapsible structure for considerable long distance volume saving in the transport. Easy and fast to reposition in case of future.MS Chequered Plate for Platform, MS pipes for support structure, Both sides, top front & roof covered with precoated 0.5mm thick Corrugated sheet, PPGI colour coated gutter with fitting for drainage system, Finishing of MS pipes with one coat of grey epoxy primer by spray. The gaps between the dock house & exisitng civl structure (if any) to be properly sealed with civil work/flashings etc
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms, ante-room,ripening chamber, transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU working on R404A (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2: CDU: air cooled condensing unit working on R404A for each room., Air Cooling Unit: 13.5 KW each unit • Ripening Room: CDU air cooled condensing unit working on R404A and Air Cooling Unit: 23 KW • Ante-room: Air cooled condesing nuit and indoor unit working on R22/R407C (to be confrimed from site), Qty: 1 no • Evaporative air cooling units: Qty-2/3 nos • Air curtains, QTY: 9 Nos. • Grading Sorting Line: Stay Fresh Make with Dry Feeder cum Sorting Inspection, Cull Belt, Washer Unit, Hot water Treatment Unit, Dryer Unit, Belt Singulator Unit, Electronic Weight Sizer, Take-Out Cross belts , Electrical Control Panel • Transformer: 160 KVA • DG set: 140 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
Miscellaneous Items : Lab Equipments of reputed makes a) Temprature Probes to measure temprature of the fruit - 6 nos b) Refractometer to check the total soluble solids - 2 no. c) Calipers to measure size of the fruit - 4 no. d) Differntial Colour Charts to Check Colour of the fruit - 2 no. e) Penetrometer to measure Pulp pressure - 2 no. f) pH measuring probe to measure pH - 2 no. g) Microscope with camera feature - 2 no. h) illuminated magnifier- 1 no h) other related equipments as may be required as per APEDA requirements
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No.Bd. M-3 page No. 380 (S. S. R. I. No. 33.66 & Page No. 283)
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.67 & Page No. 283)
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cement mortar including neat cement float,filling joints,curingandclearing etc. complete(S. S. R. I. No. 33.41& Page No. 279)
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.(S. S. R. I. No. 36.11 & Page No. 285)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. (S. S. R. I. No. 35.26 & Page No. 289)
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. (S. S. R. I. No. 33.48 & Page No. 280)
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provided either side of the panel. An additional 5mm(+/0.25) thick PVC strip of 20mm width is to be stuck on the bottom side of the 'c 'channel prelaminated paneling of 5mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/sealed to the styles and rails with 5mm(+/0.25)x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc,10mm thickness (5mm(+/0.25)x2nos) 20mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3nos M.S.powder coated but hinges of size 100mmx25MMx2mm using 32mm long steel screws drilled suitable to pass through bothth ewalls of the M.S tube. Other hard wares should be fixed with 19x6mm size steel screws including fixture fasting. Complete as per direction of engineer in charge.(S. S. R. I. No. 39.47 And Page No. 326)
MISCELLENEOUS: Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (S. S. R. I. No. 42.20 And Page No. 353)
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565(S. S. R. I. No. 41.74 And Page No. 359)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (S. S. R. I. No. 42.86 & Page No. 362)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (S. S. R. I. No. 42.11 & Page No. 352)
PLANTATION WORK: Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5
SOLID WASTE DISPOSAL: Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
Fruits & Vegetable Modern Marketing Centre, Karmad, Dist: Aurangabad
PART A : Work Portion
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Spec.No. MORTH 201(S. S. R. I. No. 2.09 & P. No. 26)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 198)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 201)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 (S. S. R. I. No. 21.37 & P. No. 201)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.22 & P. No. 199)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.24 & P. No. 199)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 225)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 230)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (S. S. R. I. No. 25.33 & P. No. 233)
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (S. S. R. I. No. 25.52 & P. No. 235)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 236) Note:- Waterproofing Chemical Added For Tarrace Slab Casting.
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.7, Page No.38 (S. S. R. I. No. 26.07 & P. No. 239)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & Page No. 240)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 229)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 245)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313. (S. S. R. I. No. 27.01 & Page No. 254)
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 29.05 & Page No. 259)
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 x 240 x 100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out\ joints and watering compete. Spec. No As director by engineer incharge (S. S. R. I. No. 29.06 & Page No. 259)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 263
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick ( CPWD D.S.R. 2015-16 w.e.f July-2016 I. No. 22.19 & Page No. 385 ) For Terrace
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc.(Excluding Tiles). complete.As directed by Engineer in charge. (S. S. R. I. No. 31.06 & Page No. 264)
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.As directed by Engineer in charge. (S. S. R. I. No. 31.05 & Page No. 264)
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec .No. Bd. J.2 Page No. 355 (S. S. R. I. No. 31.13 & Page No. 258) For External Water Proofing
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.26 & Page No. 270
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 268)
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.1 Page No. 367 (S. S. R. I. No. 32.01 And Page No. 260)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 262) For Water Tanks
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. (S. S. R. I. No. 32.11 & Page No. 261)
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.32 And Page No. 263)
Providing internal cement plaster 20mm thick in single coat in cement mortar 1:3 without neeru finish to stone masonry surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.3 Page No. 368 (S. S. R. I. No. 32.08 And Page No. 268) For Below Texture Plaster
Providing and fixing machine cut machine polished 18 to 20 mm thick telephone black / amba white / cat bary brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.. Spec. No .Bd. M.22 B Page No. 390(S. S. R. I. No. 33.35 & Page No. 278)
Providing and laying Machine Cut Machine Polished Kota Stone Flooring 25 mm To 30 mm Thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.06 & Page No. 265)
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bedof 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (S. S. R. I. No. 33.40 & Page No. 271)
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness anconfirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. b) Skirting Spec. No. Bd.M.12 Page No. 385.. (S. S. R. I. No. 33.41 & Page No. 271)
Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M. 12 Page No. 385. (S. S. R. I. No. 33.24 & Page No. 276)
Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. complete. Spec. No. Bd.M.13 Page No. 386.. (S. S. R. I. No. 33.26 & Page No. 276)
Providing sills of required material 20 mm to 25 mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing, cleaning complete.b) Granite (S. S. R. I. No. 33.22 & Page No. 276)
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames
Providing and laying in position flooring of telephone black / Amba white / Cat bary brown / Ruby red / Ocean brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. ( S. S. R. I. No. 33.34 And Page No. 278)
Providing and fixing heavy duty interlocking concrete Grey paving blocks of 80mm thickness of having a strength of 300kg/Sq.cm. of approved quality and shape on a bed of crushedsand of 25 to 30mm thick including skirting joints and cleaning etc. complete. Spec. No. As directed by engineer incharge. . Spec. No. As directed by engineer incharge. (S. S. R. I. No. 33.50 & Page No. 280)
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 35.21 & Page No. 282)
Providing and applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Spec. No. Bd.P.6 Page No.414. & Preapproval of Superintending Engineer. (S. S. R. I. No. 36.14 & Page No. 285)
Providing and applying Two Coats Of Exterior Acraylic Emulsion Paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. Spec. No. As directed by the engineer in charg. (S. S. R. I. No. 35.25 & Page No. 283)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306)
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190)
Providing and fixing Fiber Glass Reinforced Polyster Door Shutter 30 mm Thick As Per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Spec. No. As directed by Engineer in charge. (S. S. R. I. No. 39.58 And Page No. 321 For Toilet Doors
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499. (S. S. R. I. No. 39.09 And Page No. 307)
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec as directed by engineer in charge. (S. S. R. I. No. 39.68 And Page No. 323)
Providing and fixing mild steel grill work for windows, ventilators etc. 20kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 (S. S. R. I. No. 40.01 And Page No. 329)
Providing and fixing during laying in R. C. C. Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 26.68 And Page No. 245)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 23.01 & Page No. 214)
Providing and fixing collapsible steel gate in one/two leaves with hot rolled vertical channels of 18x9x3mm minimum size, crossings of M.S. flats of size 18x5mm Tor E section for runner of minimum 40x6mm size for flange, M.S. flat for top runner of minimum size 40x12mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6mm max. spacing of vertical channels be 100mm enclosed gate position and clear space of 150mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Spec as directed by engineer in charge. (S. S. R. I. No. 39.26 And Page No. 319)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports space dat 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No.40.07 And Page No. 330) For Staircase
Providing and Fixing Magnetic Stopper of type Pvc, Bell Magnet, Heavy Metal, for doors with fixing, Screwing, fastening, etc complete. As directed by Engineer Incharge. Heavy Metal Type (Aurangabad D. S. R. 2015-16 I. No. 601 & P. N. 178)
Providing and fixing colour coated Zincalume (R) AZ150 (min150gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050 mm effective cover width and nominal 25-30mm deep ribs with subtles quarefluting in the five panat nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tin alloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) Spec. No. Directed as per engineer incharge (S. S. R. I. No. 38.34 & Page No. 302)
Providing and fixing valley gutter of 22 B.W.G. (0.8mm) plain galvanised iron sheets 90cm wide with teak wood planking 20mm thick including two coats of coal-tarring the upper surface of plank etc.complete. (excluding painting to underside of plank). Spec. No. BDR 10 Page No. 455 (S. S. R. I. No. 38.09 & Page No. 298)
Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance 85%, Colour White, Fire Performance UK Class 0 /Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. ( S. S. R.I. No. 38.47 & Page No. 310)
Providing & Arrangemnt of High Back Chair -TILT MECHANISM WITH MULTI LOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U. CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.41 & Page No. 466)
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No. As Directed By Engineer In Charge (S. S. R. I. No. 42.34 And Page No. 355)
Providing and fixing 1st class white glazed earthenware orissa type W. C. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No. As directed by Engineer in Charge. (S. S. R. I. No. 42.33 And Page No. 355)
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565(S. S. R. I. No. 41.74 And Page No. 359)
Providing and fixing white glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564.(S. S. R. I. No. 41.60 And Page No. 347)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.32 And Page No. 355)
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.80 And Page No. 361)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.31 And Page No. 355)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.20 And Page No. 353)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating , bend, connecting piece of UPVC pipe up to the outside face of wall , making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 43.18 And Page No. 367)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.51 And Page No. 358)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572.(S. S. R. I. No. 42.02 And Page No. 351)
Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.. Spec. No. Bd.V.39 Page No.573.(S. S. R. I. No. 42.03 And Page No.351)
Providing and laying 150 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.. Spec. No. Bd.V.39 Page No.573.(S. S. R. I. No. 42.04 And Page N. 351)
Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. (S. S. R. I. No. 42.09 And Page No. 351)
Providing and constructing brick masonry inspection chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete.. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.12 And Page No. 352)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.36 And Page No. 355)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.37 And Page No. 355)
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming To I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.85 And Page No. 362)
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. completeSpec. No. As Directed By Engineer In Charge.(S. S. R. I. No.43.25 And Page No. 369)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.55 And Page No.358)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.56 And Page No. 358)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.57 And Page No. 359)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.59 And Page No. 359)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.60 And Page No. 359)
Providing and laying in trenches 50 mm dia. medium grade having Embossed as ISI mark galvanised iron pipes of 5.17 Kg / meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anticorrosive oil paint, 2 coats removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. Bd.V.5 Page No. 551(S. S. R. I. No. 41.23 And Page No. 344)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery upto destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters Spec. As directed by Engineer Incharge (S. S. R. I. No. 42.53 And Page No. 358)
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Spec. No. Bd.V.46 Page No.576. (S. S. R. I. No. 42.19 & Page No. 353)
Painting letters upto 20cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. Spec. No. MORTH801. (S. S. R. I. No. 6.01 & Page No. 54)
Providing & supplying Low Back Executive chairs for training hall with hydraulic hight adgestment with reclining and revolving system stand of 5 legs having saet and back in foam with fabric cloth finish with 3“ in seat and 2” in back finished with powder coated M.S. Coated base, with writing pad at front approved by Architect. Spec. No. As directed by engineer incharge. (Non SSR)
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.87 & Page No. 363)
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" diax 25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with net lon mesh including 300mm thick side filling around out side of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. As directed by Engineer in charge (S. S. R. I. No. 48.47 & Page No. 405)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 kV
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated.
Providing pair of duly tested rubber handgloves as per IS 340715 suitable for working on 22KV supply
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying and erecting LED street light fitting suitable above 26W to 36W lamp, including lamp, with PF > 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink extruded alluminium complete as per specification No FG-ODF/FLS2
Supplying and erecting street light Wall bracket made from 40 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Raw Power Mains Consealed Type)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in anapproved manner with joints required. as per specification No(EA-EP). ( For Instrumentation Labs, Wet Analysis Labs & Other Labs )
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP ( For Panel, DBs, Building Earthing etc.)
Supplying & erecting G.I.Earth wire of high purity of different sizes used for earthing or any other purposes on wall with G.I.necessary clamps as fixed on wall/cable/conduit with screws in an approved manner ( From DBs to Earth bus and other small electrical appliances etc)
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 0.75 KW/1 HP with discharge 1.6/2.9 Litres per second (LPS) for head of 9/22 m & 40 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification no. WP-CGP
Supplying & erecting mains with 4x10 Sq.mm.and Earth Wire 6 Sq.mm FR PVC Copper Wire, in HMS rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1
Supplying and erecting D.O.L. Starter 400V. 3 Phase, 50 Cycles with no volt coil and overload element with necessary materials and connected to supply Upto 7.5 H.P. (Similar to L & T make MK-1 DOL Model)
Supplying and erecting 525 V Three phase, 50 cycles, MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAR bank of all polypropylene condensers (APP) with the standard capacities of 2,3,5,7,10,12.5 and 15 kVAR units of P.F. correction for operation on 3 phase 50 cycles with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 Pole MCCB as Incommer & outgoing SP MCB (12 Poles) or TP MCB of 4 ways (12 Poles) on iron/ G.I. frame. (Vertical Busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB upto 100A, 415V capacity with S.C. rating 25 kA (Ics=100% of Icu), thermal setting with provided leads on iron frame/wooden board as per specification No. SW-SWR/MCCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 24 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB(FOR CAPACITOR)
Supplying, erecting CRCA sheeet metal one way enclosures suitable forDP MCB/TP MCB/FP MCB erected on angle iron /GI frame complete (FOR UPS i/c-o/g-2,
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XPLE armoured cable 2 core 6 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (for ups)
Supplying, erecting & terminating XPLE armoured cable 4 core 4 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
supplying and erecting ultrasonic rat repellent machine complete with necessary acc essories complete erected at site (for 7300 sqft area)
Supplying & laying HMS PVC conduit 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No.WG-MA/CC
Point wiring for light/fan/bell points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Supplying & erecting modular type electronic dimmer 1000W 2 module ISI marked approved make duly erected on provided plate & box with wiring connections complete
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Point wiring for two way light points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for independent plug, concealed type in min 20mm PVC conduit with 1.5 sq.mm FRLSgrade copper wires with moduler type switch and socket and required accessaries as per specification No WG-PW/SW(NEAR SERVICE TABLE)
Supplying & Erecting modular type 3 pin 6/16A multi socket with safety shutters combined unit ISI marked approved make duly erected on provided plate & box with wiring connections complete ( for AC 6)
Supplying and erecting modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Supplying and erecting split type variable speed inverter technology room Airconditioning unit 2 TR capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hiwall / floor mounting type complete with Refrigerent R410 A/R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. ( For 20A S/S Outlet)
Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 sq.mm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1 (Lighting Mains Consealed Type)
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Raw Power Mains Consealed Type)
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FLSR PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Consealed Type)
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying & erecting passage/corridor light fitting (2 feet) including LED 9 W with comprises of extruded channel in plastic silver grey colour and with same plastic end cap on provided pvc block/wooden board
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete
Supplying and erecting ding dong/ electronic musical type call bell with heavy duty coil suitable to operate on 230V AC supply erected on polished double wooden block /sunmica block of suitable size
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting 8W Ceiling/wall mounted speaker(similar to Ahuja PS-6081T-PS400T/Philips)
Supplying and erecting upto1000 W Ahuja Amplifier with multiple audio outputs
Supplying and erecting 48"led smart tv(Similar to Samsung 49k5570)
Supplying and erecting fixed mike(Similar to AHUJA Paging Mike, Acm-66)
Supplying and erecting Remote mike(Similar to Ahuja AWM-490VHL Microphone)
Supplying and erecting Foldable Screen((Similar to Egate Eylet 2.13Mx 1.52M)
Supplying and erecting Web Camera((Similar to LogitechHD C525)
Supplying and erecting IP Camera 2.6mp 20mtrs((Similar to Sparsh)
Supplying and erecting 16 chanel NVR((Similar to Sparsh)
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps Unmanaged Gigabit PoE Switch( New)
Supplying, installing, testing & commissioning Digital (Hybrid) type EPABX of 3 x 8 extensions complete.
Supplying and erecting 16 port LAN SWITCH
Supplying, fixing, and configuring Broadband ADSL Router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL
Supplying, and installing HDMI cable low voltage grade as per specifications having 20 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing HDMI cable low voltage grade as per specifications having 15 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing HDMI cable low voltage grade as per specifications having 10 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing VGA cable to be laid in provided conduits and terminating as per specifications having 15 mtr cord length with male/female VGA connector as per specification complete
Supplying, and installing AV cable low voktage gradeas per specifications having 15 mtr cord length with required connector 3RCAX3RCA cable complte
Supplying, and fixing Cat-6 LSZH CABLE suitable for LAN/WAN as per specifications complete
Supplying, erecting testing and commissioning 1,5 sq.mm speaker wire complete
Supplying and erecting on line UPS pure sine waveof 6 KVA capacity complete with standard features along with necessary SMF batteries for 30 mins backup as per specification no AP-UPS
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 /15683 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Overhauling of Machineries for 1 precooling chamber, 1 cold rooms ,ante-room, DG set, LT/APFC panels and other electrical system, dock and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU working on R404A (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1: CDU: air cooled condensing unit working on R404A for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit working on R22/R407C, 11.5 kW Qty: 1 no • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 14 Nos. • DG set: 62.5 KVA • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. • LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
PLANTATION WORK: Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5
SOLID WASTE DISPOSAL: Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
Fruits & Vegetable Modern Marketing Centre, Ardhapur, Dist: Nanded
PART A : Work Portion
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.87 & Page No. 363)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (S. S. R. I. No. 42.02 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. Class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.09 & Page No. 351)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" diax 25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with net lon mesh including 300mm thick side filling around out side of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. As directed by Engineer in charge (S. S. R. I. No. 48.47 & Page No. 405)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means Spec.No. : Bd.A.3, Page No. 259.(S. S. R. I. No. 21.10& P. No. 197)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. ( Beed District D.S.R, Page No. 125, Sr. No. 486 )
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand/Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & P. No. 240)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 268)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 269)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. (S. S. R. I. No. 32.11 & Page No. 261)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 23.01 & Page No. 223 )
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
SITC of Banana Ripening System as per the general technical specifications consisting of a) Ethylene Generator along with piping b) Ethylene analyzer ( Range 0 - 500 ppm ) c) Carbon- dioxide gas analizer ( sensor 0% - 5% ) d) Centralised control panel for monitoring of 1 no. ripening room for observing parameters such as temp. , R.H. CO2 level ,Ethylene level etc. e) Temperature indicator & R. H. indicator for each Chamber The ripening system shall be fully automatic & suitable have the facility to start ripening process in a given room for a fixed time interval & fixed concentration inside the room.The system should have the facility to start ripening process in a given room for a fixed time interval & fixed concentration. The Ethylene & carbon di-oxide gas analyzer monitoring system should have LED display ,built in Ethylene & CO2 sensors.It should analyze & display the ethylene concentration in ppm level ( 0 to 500 ppm ) & CO2 level in 1 % ( 0.01 % to 5 % ) with alarm out puts, analogue outputs. Ethylene sensors will regulate the operation of the generator automatically Necessary quantity of ethylene solution to achieve 50 cycles of ripening process in banana ripening store to be included in the cost.Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
SITC of Ventilation System design to supply fresh air & extract & CO2 laden air with motorised dampers, with exhaust & supply fans, piping, fittings, timers & controls, power& control wiring etc
Humidification system for chamber complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks/ point of supply to humidifier unit, fitting ,valves,solenoid valves with strainers and humidity indicator cum controller etc. to maintain the relative humidity in the design range. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 5 Lit/hr.
Overhauling of Machineries for 1 precooling chamber, 1 cold rooms , ante-room, DG set, LT/APFC panels and other electrical system, dock and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU working on R404A (2 nos), Air Handling Unit:Star Coolers make HHC 42B 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1: CDU: air cooled condensing unit working on R404A for each room., Air Cooling Unit:Star coolers make CIC 2066 Sp 13.5 KW • Ante-room: Air cooled condesing unit and indoor unit Star coolers CIC 1066 working on R407C, 11.5 kW Qty: 1 no • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 14 Nos. • DG set: 62.5 KVA • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. • LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
Handicap Toilet
EXCAVATION & FILLING
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.(S. S. R. I. No. 21.14& P. No. 198)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 (S. S. R. I. No. 21.37 & P. No. 191)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.22 & P. No. 189)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.24 & P. No. 199)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (S. S. R. I. No. 25.33 & P. No. 225)
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (S. S. R. I. No. 25.52 & P. No. 227)
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.7, Page No.38 (S. S. R. I. No. 26.07 & P. No. 230)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 221)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313.
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 29.05 & Page No. 251)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 255) For Toilet Blocks And Terrace
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick (S. S. R. I. No. 22.19 & Page No. 385)
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.26 & Page No. 262)
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No.Bd. M-3 page No. 380 (S. S. R. I. No. 33.66 & Page No. 283)
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.67 & Page No. 283)
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cement mortar including neat cement float,filling joints,curingandclearing etc. complete(S. S. R. I. No. 33.41& Page No. 279)
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 35.21 & Page No. 282)
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.(S. S. R. I. No. 36.11 & Page No. 285)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. (S. S. R. I. No. 35.26 & Page No. 289)
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. (S. S. R. I. No. 33.48 & Page No. 280)
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provided either side of the panel. An additional 5mm(+/0.25) thick PVC strip of 20mm width is to be stuck on the bottom side of the 'c 'channel prelaminated paneling of 5mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/sealed to the styles and rails with 5mm(+/0.25)x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc,10mm thickness (5mm(+/0.25)x2nos) 20mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3nos M.S.powder coated but hinges of size 100mmx25MMx2mm using 32mm long steel screws drilled suitable to pass through bothth ewalls of the M.S tube. Other hard wares should be fixed with 19x6mm size steel screws including fixture fasting. Complete as per direction of engineer in charge.(S. S. R. I. No. 39.47 And Page No. 326)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium rames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 324)
Providing and fixing mild steel grill work for windows, ventilators, etc. 20 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.. Spec. No. Bd.U.1 Page No. 537 (S. S. R. I. No. 40.01 And Page No. 329)
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (S. S. R. I. No. 42.20 And Page No. 353)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thickat top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. 2019-20 I. No.40.07And Page No. 330) For Staircase
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete 2019-20 I. No.42.87And Page No. 363)
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565(S. S. R. I. No. 41.74 And Page No. 359)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (S. S. R. I. No. 42.54 & Page No. 358)
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.57 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.58 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.59 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.60 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.55 & Page No. 358)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.37 & Page No. 355)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.36 & Page No. 355)
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (S. S. R. I. No. 42.86 & Page No. 362)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (S. S. R. I. No. 42.11 & Page No. 352)
PLANTATION WORK: Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5
SOLID WASTE DISPOSAL: Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
Export Facility Center, Latur, Dist. Latur
PART A : Work Portion
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Spec.No. MORTH 201(S. S. R. I. No. 2.09 & P. No. 26)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 (S. S. R. I. No. 21.37 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.22 & P. No. 199)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.24 & P. No. 199)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (S. S. R. I. No. 25.33 & P. No. 233)
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (S. S. R. I. No. 25.52 & P. No. 227)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227) Note:- Waterproofing Chemical Added For Tarrace Slab Casting.
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.7, Page No.38 (S. S. R. I. No. 26.07 & P. No. 230)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & Page No. 231) Note:- Waterproofing Chemical Added For Water Tank Pardi Casting
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 221)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313. (S. S. R. I. No. 27.01 & Page No. 254)
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 29.05 & Page No. 251)
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 x 240 x 100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out\ joints and watering compete. Spec. No As director by engineer incharge (S. S. R. I. No. 29.06 & Page No. 259)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 255) For Toilet Blocks And Terrace
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick ( CPWD D.S.R. 2015-16 w.e.f July-2016 I. No. 22.19 & Page No. 385 ) For Terrace
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc.(Excluding Tiles). complete.As directed by Engineer in charge. (S. S. R. I. No. 31.06 & Page No. 256) For Sunk Vertical Sides At Toilet Blocks
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.As directed by Engineer in charge. (S. S. R. I. No. 31.05 & Page No. 256) For Flooring At Toilet Blocks
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec .No. Bd. J.2 Page No. 355 (S. S. R. I. No. 31.13 & Page No. 258) For External Water Proofing
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.26 & Page No. 262)
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 260)
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.1 Page No. 367 (S. S. R. I. No. 32.01 And Page No. 260)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 262) For Water Tanks
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. (S. S. R. I. No. 32.11 & Page No. 261)
Providing internal cement plaster 20mm thick in single coat in cement mortar 1:3 without neeru finish to stone masonry surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.3 Page No. 368 (S. S. R. I. No. 32.08 And Page No. 268) For Below Texture Plaster
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.32 And Page No. 263)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete Spec. No .BDM-22, Page No. 390 (S. S. R. I. No. 33.18 & Page No. 268)
Providing and laying Machine Cut Machine Polished Kota Stone Flooring 25 mm To 30 mm Thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.06 & Page No. 265)
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bedof 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (S. S. R. I. No. 33.40 & Page No. 271)
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness anconfirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. b) Skirting Spec. No. Bd.M.12 Page No. 385.. (S. S. R. I. No. 33.41 & Page No. 279)
Providing and laying ceramic tiles having size 30cm. x 45cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M.13 Page No. 386. (S. S. R. I. No. 33.26 & Page No. 277)
Providing and fixing machine cut machine polished 18mm to 20mm thick telephone black/ AmbaWhite/ Catbary brown/ RBI red/ Ocean Brown granite stone for treads and risers of steps and stair cases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec. No. Bd.M.22 B/Page No. 390. (S. S. R. I. No. 33.35 & Page No. 278)
Providing and fixing heavy duty interlocking concrete Grey paving blocks of 80mm thickness of having a strength of 300kg/Sq.cm. of approved quality and shape on a bed of crushedsand of 25 to 30mm thick including skirting joints and cleaning etc. complete. Spec. No. As directed by engineer incharge. . Spec. No. As directed by engineer incharge. (S. S. R. I. No. 33.50 & Page No. 280)
Providing and laying Antiskid Ceramic tiles of approved quality of size 30cm x 30cm and confirming to IS 15622-2006 (Group-BIIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Spec. No. Bd.M.12 Page No. 385. (S. S. R. I. No. 33.67 & Page No. 283)
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding / moulding the edges etc. complete. One side polish Spec. No. Bd.M.35 B / Page No.393 (S. S. R. I. No. 33.37 & Page No. 270)
Providing and constructing Granite Kitchen Platform With Fixing Of Stainless Steel Sink / Polypropelyn Sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 41.78 & Page No. 342)
Providing 25 mm To 30 mm Thick Partition Of Polished Black Kadappa Stone Slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. b) Both Side Polish. Spec. No. Bd.M.35 B /P No.393 ( S. S. R. I. No. 33.33 And Page No. 270)
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 35.21 & Page No. 282)
Providing and applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Spec. No. Bd.P.6 Page No.414. & Preapproval of Superintending Engineer. (S. S. R. I. No. 36.14 & Page No. 285)
Providing and applying Two Coats Of Exterior Acraylic Emulsion Paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. Spec. No. As directed by the engineer in charg. (S. S. R. I. No. 35.25 & Page No. 283)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306)
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190)
Providing and fixing Fiber Glass Reinforced Polyster Door Shutter 30 mm Thick As Per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Spec. No. As directed by Engineer in charge. (S. S. R. I. No. 39.58 And Page No. 321 For Toilet Doors
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499. (S. S. R. I. No. 39.09 And Page No. 307) For Main Doors And Lab Doors
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec as directed by engineer in charge. (S. S. R. I. No. 39.68 And Page No. 323)
Providing and fixing collapsible steel gate in one/two leaves with hot rolled vertical channels of 18x9x3mm minimum size, crossings of M.S. flats of size 18x5mm Tor E section for runner of minimum 40x6mm size for flange, M.S. flat for top runner of minimum size 40x12mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6mm max. spacing of vertical channels be 100mm enclosed gate position and clear space of 150mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Spec as directed by engineer in charge. (S. S. R. I. No. 39.26 And Page No. 319)
Providing and fixing mild steel grill work for windows, ventilators etc. 20kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 (S. S. R. I. No. 40.01 And Page No. 329)
Providing and fixing during laying in R. C. C. Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 26.68 And Page No. 253)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 23.01 & Page No. 223) For Service Ladder, Main Entrance Door And Canopy
Providing and fixing colour coated Zincalume (R) AZ150 (min150gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050 mm effective cover width and nominal 25-30mm deep ribs with subtles quarefluting in the five panat nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tin alloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) Spec. No. Directed as per engineer incharge (S. S. R. I. No. 38.34 & Page No. 302)
Providing and fixing valley gutter of 22 B.W.G. (0.8mm) plain galvanised iron sheets 90cm wide with teak wood planking 20mm thick including two coats of coal-tarring the upper surface of plank etc.complete. (excluding painting to underside of plank). Spec. No. BDR 10 Page No. 455 (S. S. R. I. No. 38.09 & Page No. 298)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports space dat 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No.40.07 And Page No. 330) For Staircase
Painting letters upto 20cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. Spec. No. MORTH801 (S. S. R. I. No. 6.01 & Page No. 54)
Providing & supplying Low Back Executive chairs for training hall with hydraulic hight adgestment with reclining and revolving system stand of 5 legs having saet and back in foam with fabric cloth finish with 3“ in seat and 2” in back finished with powder coated M.S. Coated base, with writing pad at front approved by Architect. Spec. No. As directed by engineer incharge. (Non SSR)
Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9-1.0, Light Reflectance ? 85%, Colour White, Fire Performance UK Class 0/ Class1 (BS476 pt-6&7) in module size of 600x600x15mm, suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channe l32 with 15mm wide T-section flanges colour white having rotary stitching on all Tsections i.e. the Main Runner, 1200mm and 600mm Cross Tees with a web height of 32mm and a load carrying capacity of 7Kgs/M2 with a minimum pull out strength of 100kgs. The T Sections have a Galvanizing of 90grams per M2 and need to be installed with Suspension system The Tile and Grid system used to gether should carrya 1 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec. No. As directed by engineer incharge. (S. S. R. I. No. 38.47 & Page No. 310)
Providing & Arrangemnt of High Back Chair -TILT MECHANISM WITH MULTI LOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U. CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.41 & Page No. 466)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 42.17 & Page No. 353)
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Spec. No. Bd.V.46 Page No.576. (S. S. R. I. No. 42.19 & Page No. 353)
Providing and fixing European Type White Glazed Earthenware Coupled Closet Symphonic Trap With symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No. As Directed By Engineer In Charge (S. S. R. I. No. 42.34 & Page No. 355)
Providing and fixing Coloured Glazed Earthenware Wash Hand Basin Of 63 Cm x 45 Cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (S. S. R. I. No. 41.74 & Page No. 349)
Providing and fixing White Glazed Earthenware Lipped Flat Back / Corner Type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564. (S. S. R. I. No. 41.60 & Page No. 347)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.78 & Page No. 361)
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.84 & Page No. 362)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge (S. S. R. I. No. 42.83 & Page No. 362)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.82 & Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.79 & Page No. 361)
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.32 & Page No. 355)
Providing and fixing Chromium Plated Towel Rod 16 mm Dia And 75 Cm. In Length including all accessories complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.31 & Page No. 355)
Providing and fixing 450 mm x 550 mm Size Superior Type Belgium Mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.20 & Page No. 353)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating , bend, connecting piece of UPVC pipe up to the outside face of wall , making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 43.18 & Page No. 367)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.51 & Page No. 358)
Providing and laying 100mm dia salt glazed stoneware pipe including fittings such as bends, tees,single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.. Spec. No. Bd.V.39, Page No. 573. (S. S. R. I. No. 42.03 & Page No. 351)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.36 & Page No. 355)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.37 & Page No. 355)
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.87 & Page No. 363)
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 43.25 & Page No. 369)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.55 & Page No. 358)
Providing and fixing on Walls / Ceiling / Floor 20 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.56 & Page No. 358)
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.57 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.58 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.59 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.60 & Page No. 359)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (S. S. R. I. No. 42.02 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)
Providing and laying concrete pipes of I.S. NP. Class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.09 & Page No. 351)
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" diax 25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with net lon mesh including 300mm thick side filling around out side of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. As directed by Engineer in charge (S. S. R. I. No. 48.47 & Page No. 405)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 kV
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated.
Providing pair of duly tested rubber handgloves as per IS 340715 suitable for working on 22KV supply
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying and erecting LED street light fitting suitable above 26W to 36W lamp, including lamp, with PF > 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink extruded alluminium complete as per specification No FG-ODF/FLS2
Supplying and erecting street light Wall bracket made from 40 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Raw Power Mains Consealed Type)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in anapproved manner with joints required. as per specification No(EA-EP). )
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP ( For Panel, DBs, Building Earthing etc.)
Supplying & erecting G.I.Earth wire of high purity of different sizes used for earthing or any other purposes on wall with G.I.necessary clamps as fixed on wall/cable/conduit with screws in an approved manner ( From DBs to Earth bus and other small electrical appliances etc)
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner
Supplying & erecting Centrifugal Water Pump (Monoblock), 415 V, Three Phase 50 Cycles A.C. Supply of 3.75 KW/ 5 HP with discharge 2/4.1 Liters per second (LPS) for head of 36/52 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification No. WP-CG
Supplying & erecting mains with 4x10 Sq.mm.and Earth Wire 6 Sq.mm FR PVC Copper Wire, in HMS rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1
Supplying and erecting D.O.L. Starter 400V. 3 Phase, 50 Cycles with no volt coil and overload element with necessary materials and connected to supply Upto 7.5 H.P. (Similar to L & T make MK-1 DOL Model)
Supplying and erecting 525 V Three phase, 50 cycles, MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAR bank of all polypropylene condensers (APP) with the standard capacities of 2,3,5,7,10,12.5 and 15 kVAR units of P.F. correction for operation on 3 phase 50 cycles with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 Pole MCCB as Incommer & outgoing SP MCB (12 Poles) or TP MCB of 4 ways (12 Poles) on iron/ G.I. frame. (Vertical Busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB upto 100A, 415V capacity with S.C. rating 25 kA (Ics=100% of Icu), thermal setting with provided leads on iron frame/wooden board as per specification No. SW-SWR/MCCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 24 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB(FOR CAPACITOR)
Supplying, erecting CRCA sheeet metal one way enclosures suitable forDP MCB/TP MCB/FP MCB erected on angle iron /GI frame complete (FOR UPS i/c-o/g-2,
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XPLE armoured cable 2 core 6 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (for ups)
Supplying, erecting & terminating XPLE armoured cable 4 core 4 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
supplying and erecting ultrasonic rat repellent machine complete with necessary acc essories complete erected at site (for 7300 sqft area)
Supplying & laying HMS PVC conduit 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No.WG-MA/CC
Point wiring for light/fan/bell points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Supplying & erecting modular type electronic dimmer 1000W 2 module ISI marked approved make duly erected on provided plate & box with wiring connections complete
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Point wiring for two way light points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for independent plug, concealed type in min 20mm PVC conduit with 1.5 sq.mm FRLSgrade copper wires with moduler type switch and socket and required accessaries as per specification No WG-PW/SW
Supplying & Erecting modular type 3 pin 6/16A multi socket with safety shutters combined unit ISI marked approved make duly erected on provided plate & box with wiring connections complete ( for AC 13)
Supplying and erecting modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Supplying and erecting split type variable speed inverter technology room Airconditioning unit 1.5 TR capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hiwall / floor mounting type complete with Refrigerent R410 A/R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and erecting split type variable speed inverter technology room Airconditioning unit 2 TR capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hiwall / floor mounting type complete with Refrigerent R410 A/R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. ( For 20A S/S Outlet)
Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 sq.mm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1 (Lighting Mains Consealed Type)
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Raw Power Mains Consealed Type)
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FLSR PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Consealed Type)
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying & erecting passage/corridor light fitting (2 feet) including LED 9 W with comprises of extruded channel in plastic silver grey colour and with same plastic end cap on provided pvc block/wooden board
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete
Supplying and erecting ding dong/ electronic musical type call bell with heavy duty coil suitable to operate on 230V AC supply erected on polished double wooden block /sunmica block of suitable size
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting 8W Ceiling/wall mounted speaker(similar to AhujaCS-6081T-PS400T/Philips)
Supplying and erecting upto 1000 W Ahuja Amplifier with multiple audio outputs
Supplying and erecting 48"led smart tv(Similar to Samsung 49k5570)
Supplying and erecting fixed mike(Similar to AHUJA Paging Mike, Acm-66)
Supplying and erecting Remote mike(Similar to Ahuja AWM-490VHL Microphone)
Supplying and erecting Foldable Screen((Similar to Egate Eylet 2.13Mx 1.52M)
Supplying and erecting Web Camera((Similar to LogitechHD C525)
Supplying and erecting IP Camera 2.6mp 20mtrs((Similar to Sparsh)
Supplying and erecting 16 chanel NVR((Similar to Sparsh)
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps Unmanaged Gigabit PoE Switch( New)
Supplying, installing, testing & commissioning Digital (Hybrid) type EPABX of 3 x 8 extensions complete.
Supplying and erecting 16 port LAN SWITCH
Supplying, fixing, and configuring Broadband ADSL Router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL
Supplying, and installing HDMI cable low voltage grade as per specifications having 20 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing HDMI cable low voltage grade as per specifications having 15 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing HDMI cable low voltage grade as per specifications having 10 m cord lengthwith male/female 19 pinHDMI connector as per specification
Supplying, and installing VGA cable to be laid in provided conduits and terminating as per specifications having 15 mtr cord length with male/female VGA connector as per specification complete
Supplying, and installing AV cable low voktage gradeas per specifications having 15 mtr cord length with required connector 3RCAX3RCA cable complte
Supplying, and fixing Cat-6 LSZH CABLE suitable for LAN/WAN as per specifications complete
Supplying, erecting testing and commissioning 1,5 sq.mm speaker wire complete
Supplying and erecting on line UPS pure sine waveof 6 KVA capacity complete with standard features along with necessary SMF batteries for 30 mins backup as per specification no AP-UPS
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 /15683 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
DOCK DOOR & SHELTER Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK SHELTER : Retractable type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Support structure to be included in the cost. Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
DOCK LEVELER Designed for Hydraulic operation in accordance of EN:1398 in steel construction as per General technical specification Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included.Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
Dock House Structure with suitable provision to install Dock Leveler, Dock Shelter & Motorised Overhead Door Approx. Door House Size: Width 3400mm x Length 2600mm x Height 5450mm Self-contained loading bay to be installed in front of the ante-room/loading unloading passage The design and layout of the dock house shall be adapted to suit the requirements of the site. Steel dock comprising of supporting legs.,Collapsible structure for considerable long distance volume saving in the transport. Easy and fast to reposition in case of future.MS Chequered Plate for Platform ,MS pipes for support structure, Both sides, top front & roof covered with precoated 0.5mm thick Corrugated sheet, PPGI colour coated gutter with fitting for drainage system, Finishing of MS pipes with one coat of grey epoxy primer by spray. The gaps between the dock house & exisitng civl structure (if any) to be properly sealed with civil work/flashings etc
Replacment of compressor of air cooled condensing unit complete with removal of exisitng compressor, supply and installation of new compressor model Emerson ZB66KQ / eqvt model working on R404a refirgerant, fresh refrigerant charge in the system, testing & commissioning of the system
SITC of Banana Ripening System as per the general technical specifications consisting of a) Ethylene Generator along with piping b) Ethylene analyzer ( Range 0 - 500 ppm ) c) Carbon- dioxide gas analizer ( sensor 0% - 5% ) d) Centralised control panel for monitoring of 1 no. ripening room for observing parameters such as temp. , R.H. CO2 level ,Ethylene level etc. e) Temperature indicator & R. H. indicator for each Chamber The ripening system shall be fully automatic & suitable have the facility to start ripening process in a given room for a fixed time interval & fixed concentration inside the room.The system should have the facility to start ripening process in a given room for a fixed time interval & fixed concentration. The Ethylene & carbon di-oxide gas analyzer monitoring system should have LED display ,built in Ethylene & CO2 sensors.It should analyze & display the ethylene concentration in ppm level ( 0 to 500 ppm ) & CO2 level in 1 % ( 0.01 % to 5 % ) with alarm out puts, analogue outputs. Ethylene sensors will regulate the operation of the generator automatically Necessary quantity of ethylene solution to achieve 50 cycles of ripening process in banana ripening store to be included in the cost.Cost for electrical supply connection to ripening panel to be arranged by contractor from available supply point as per site condtition.
SITC of Ventilation System design to supply fresh air & extract & CO2 laden air with motorised dampers, with exhaust & supply fans ,piping, fittings, timers & controls, power& control wiring etc
Humidification system for chamber complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks/ point of supply to humidifier unit, fitting ,valves,solenoid valves with strainers and humidity indicator cum controller etc. to maintain the relative humidity in the design range. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 5 Lit/hr.
Removal of exisitng electronic sizer and SITC of new imported electronic weight sier suitable for operation of 2 MT/hr grading sorting line for mangoes/ sweet lime • Intelligent chain of 5 x1 +1 exits (outlets). • Electronic system of weight, with high-precision scales • Electronic equipment cabinet. • System of lubricating on chains and weight scales • Electronic speed Variator.
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,ante-room,ripening chamber, transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 4TCS-12.2Y working on R404A (2 nos), Air Handling Unit: Star Coolers & condenser make model no HHC 42 B 43 kW capacity, water pump: 1 x 3 Kw • Cold Storage 1,2: CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 4DC-7.2Y working on R404A for each room., Air Cooling Unit: Star Coolers & condenser make model no CIC-2084Sp, 13.5 KW each unit • Ripening Room: CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 2CC-4.2Y working on R404A and Air Cooling Unit: Star Coolers & condenser make model CIC-2166 (TWIN CURCUIT), 23 KW • Ante-room: Blue star make air cooled ducted split unit model no DSA661R1,R22, Qty: 1 no • Evaporative air cooling units: Qty-3 nos: National refrigeration make , model no HPS 150 AW with 14500 CMH, 5HP motor, 10 micron box type filter HDPE media, 0.5 HP pump, Krugar make fan, model no BDB500/CM (CLI) with 4kW motor • Air curtains: Euronics make model no EAC3/EAC4/EAC5, QTY: 9 Nos. • Grading Sorting Line: Stay Fresh Make with Dry Feeder cum Sorting Inspection, Cull Belt, Washer Unit, Hot water Treatment Unit, Dryer Unit, Belt Singulator Unit, Electronic Weight Sizer, Take-Out Cross belts , Electrical Control Panel • Transformer: 160 KVA • DG set: 160 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel: 110 KVAr APFC panel with 2 nos 5 KVAR Capacitors, 2 Nos 10 KVAR Capacitors, 4 Nos 20 KVAR capacitor banks, microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
PLANTATION WORK
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5
SOLID WASTE DISPOSAL: Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
APEDA Accreditation of Export Facility Centre, Beed
PART A : Work Portion
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Spec.No. MORTH 201(S. S. R. I. No. 2.09 & P. No. 26)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 (S. S. R. I. No. 21.37 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.22 & P. No. 189)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R.I. No. 21.24 & P. No. 199)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (S. S. R. I. No. 25.33 & P. No. 225)
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (S. S. R. I. No. 25.52 & P. No. 227)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227) Note:- Waterproofing Chemical Added For Tarrace Slab Casting.
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.7, Page No.38 (S. S. R. I. No. 26.07 & P. No. 230)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & Page No. 231) Note:- Waterproofing Chemical Added For Water Tank Pardi Casting
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 221)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313.
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 29.05 & Page No. 251)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 255) For Toilet Blocks And Terrace
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick (S. S. R. I. No. 22.19 & Page No. 385)
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec .No. Bd. J.2 Page No. 355 (S. S. R. I. No. 31.13 & Page No. 258) For External Water Proofing
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.26 & Page No. 262)
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 260)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 262) For Water Tanks
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. (S. S. R. I. No. 32.11 & Page No. 261)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete Spec. No .BDM-22, Page No. 390 (S. S. R. I. No. 33.18 & Page No. 268)
Providing and laying Machine Cut Machine Polished Kota Stone Flooring 25 mm To 30 mm Thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.06 & Page No. 265)
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 35.21 & Page No. 282)
Providing and applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Spec. No. Bd.P.6 Page No.414. & Preapproval of Superintending Engineer. (S. S. R. I. No. 36.14 & Page No. 285)
Providing and applying Two Coats Of Exterior Acraylic Emulsion Paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. Spec. No. As directed by the engineer in charg. (S. S. R. I. No. 35.25 & Page No. 283)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.. Spec. No. Bd.O.5 Page No.405.(S. S. R. I. No. 35.07 & Page No. 286)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306)
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190)
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499. (S. S. R. I. No. 39.09 And Page No. 307) For Main Doors And Lab Doors
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317)
Providing and fixing mild steel grill work for windows, ventilators, etc. 20 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.. Spec. No. Bd.U.1 Page No. 537 (S. S. R. I. No. 40.01 And Page No. 329)
Providing and fixing during laying in R. C. C. Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 26.68 And Page No. 245)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thickat top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec. No. As Directed By Engineer In Charge. (S. S. R. 2019-20 I. No.40.07And Page No. 330) For Staircase
Providing and Fixing Magnetic Stopper of type Pvc, Bell Magnet, Heavy Metal, for doors with fixing, Screwing, fastening, etc complete. As directed by Engineer Incharge. Heavy Metal Type (Aurangabad D. S. R. 2015-16 I. No. 601 & P. N. 178)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) (S. S. R. 2019-20 I. No.39.24 And Page No. 318)
Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT-TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18mm thick Prelaminated particle board with PVC edge band as per drawing Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.21 & Page No. 460)
Providing & Arrangemnt of High Back Chair -TILT MECHANISM WITH MULTI LOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U. CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Spec. No. As directed by engineer incharge. (S. S. R. I. No. 51.41 & Page No. 466)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (S. S. R. I. No. 42.54 & Page No. 358)
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.57 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.58 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.59 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.60 & Page No. 359)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S. S. R. I. No. 42.55 & Page No. 358)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.37 & Page No. 355)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.36 & Page No. 355)
Painting letters upto 20cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. Spec. No. MORTH801 (S. S. R. I. No. 6.05 & Page No. 54)
Providing and fixing Jali welded mesh 50*25 11 Guage with necessary fittings as per requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. Building material No. 25 & Page No. 517)
SOLID WASTE DISPOSAL: Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
SEDIMENTATION TANK:
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
PLAIN CEMENT CONCRETE
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313.
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 260)
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,ante-room,ripening chamber, transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 4TCS-12.2Y working on R404A (2 nos), Air Handling Unit: Star Coolers & condenser make model no HHC 42 B 43 kW capacity, water pump: 1 x 3 Kw • Cold Storage 1,2: CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 4DC-7.2Y working on R404A for each room., Air Cooling Unit: Star Coolers & condenser make model no CIC-2084Sp, 13.5 KW each unit • Ripening Room: CDU: National refrigeration make air cooled condensing unit with Bitzer make compressor model no 2CC-4.2Y working on R404A and Air Cooling Unit: Star Coolers & condenser make model CIC-2166 (TWIN CURCUIT), 23 KW • Ante-room: Blue star make air cooled ducted split unit model no DSA661R1,R22, Qty: 1 no • Evaporative air cooling units: Qty-3 nos: National refrigeration make , model no HPS 150 AW with 14500 CMH, 5HP motor, 10 micron box type filter HDPE media, 0.5 HP pump, Krugar make fan, model no BDB500/CM (CLI) with 4kW motor • Air curtains: Euronics make model no EAC3/EAC4/EAC5, QTY: 9 Nos. • Grading Sorting Line: Stay Fresh Make with Dry Feeder cum Sorting Inspection, Cull Belt, Washer Unit, Hot water Treatment Unit, Dryer Unit, Belt Singulator Unit, Electronic Weight Sizer, Take-Out Cross belts , Electrical Control Panel • Transformer: 160 KVA • DG set: 160 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel: 110 KVAr APFC panel with 2 nos 5 KVAR Capacitors, 2 Nos 10 KVAR Capacitors, 4 Nos 20 KVAR capacitor banks, microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
Miscellaneous Items : Lab Equipments of reputed makes a) Temprature Probes to measure temprature of the fruit - 6 nos b) Refractometer to check the total soluble solids - 2 no. c) Calipers to measure size of the fruit - 4 no. d) Differntial Colour Charts to Check Colour of the fruit - 2 no. e) Penetrometer to measure Pulp pressure - 2 no. f) pH measuring probe to measure pH - 2 no. g) Microscope with camera feature - 2 no. h) illuminated magnifier- 1 no h) other related equipments as may be required as per APEDA requirements
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No.Bd. M-3 page No. 380 (S. S. R. I. No. 33.66 & Page No. 283)
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. Spec. No. Bd.M.3 Page No. 380 (S. S. R. I. No. 33.67 & Page No. 283)
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cement mortar including neat cement float,filling joints,curingandclearing etc. complete(S. S. R. I. No. 33.41& Page No. 279)
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.(S. S. R. I. No. 36.11 & Page No. 285)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. (S. S. R. I. No. 35.26 & Page No. 289)
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. (S. S. R. I. No. 33.48 & Page No. 280)
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provided either side of the panel. An additional 5mm(+/0.25) thick PVC strip of 20mm width is to be stuck on the bottom side of the 'c 'channel prelaminated paneling of 5mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/sealed to the styles and rails with 5mm(+/0.25)x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc,10mm thickness (5mm(+/0.25)x2nos) 20mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3nos M.S.powder coated but hinges of size 100mmx25MMx2mm using 32mm long steel screws drilled suitable to pass through bothth ewalls of the M.S tube. Other hard wares should be fixed with 19x6mm size steel screws including fixture fasting. Complete as per direction of engineer in charge.(S. S. R. I. No. 39.47 And Page No. 326)
MISCELLENEOUS : Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (S. S. R. I. No. 42.20 And Page No. 353)
MISCELLENEOUS : Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete 2019-20 I. No.42.87And Page No. 363)
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565(S. S. R. I. No. 41.74 And Page No. 359)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (S. S. R. I. No. 42.86 & Page No. 362)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (S. S. R. I. No. 42.11 & Page No. 352)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
Construction, Supply, Installation, Testing, Commisioning of Additional Facility center for custard apple at Beed, Dist. Beed
PART A : Work Portion Civil work Facility building and Storme water line
Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area . (P. No. 26 Item No. 2.07 Morth 201)
Excavation for foundation in earth soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling, with available earth/ murum, ramming, watering (including shoring and strutting) complete. (lift up to 1.5 m) By Mechanical means. (P. No. 197 Item No. 21.02 BDA1)
Excavation for foundation in hard murum including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, including dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering (including shoring and strutting) complete. (lift up to 1.5 m) By Mechanical means. (P. No. 197 Item No. 21.06 BDA2)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, including dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering (including shoring and strutting) complete. (lift from 1.5 m to 3.0) By Mechanical means. (P. No. 197 Item No. 21.10 BDA 3)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. ( AS per Item no. 22.41 of schedule of rates of NBO ) (P. No. 199 Item No. 21.22 BDW)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO ) (P. No. 199 Item No. 21.24 BDW)
Filling in plinth and floors with contractors material/brought from outside and approved by Architect in charge in layers of 15cm. to 20cm. including watering and compaction etc. complete. (P. No.201 Item No.21.37 BDA 11)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (P. No. 201 Item No. 21.40 BDA)
Providing and casting in situ cement concrete M15 of trap / granite / quartzite / gneiss metal for coping to plinth or parapet,moulded or chamfered as per drawing or as directed including steel centering, plywood / steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete.The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 229 Item No. 24.16 BDE3)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 226 Item No. 24.01 BDE1)
Providing and laying in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 230 Item No. 25.13 BDF 3)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 232 Item No. 25.33 BDF5) : Gorund Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 232 Item No. 25.33 BDF5): First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (P. No. 234 Item No. 25.52 BDF6): Gorund Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (P. No. 234 Item No. 25.52 BDF6): First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No.239 Item No. 26.07 BDF9)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 236 Item No. 25.72 BDF8): Gorund Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 236 Item No. 25.72 BDF8): First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 241 Item No. 26.26 BDF 13A)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/Crushed sand VSI Grade finely washed etc) (P. No. 240 Item No. 26.19 BDF11)
Providing and fixing in position TMT FE 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (P. No. 245 Item No. 26.33 BDF17)
Providing and applying Anti corrosive treatment to reinforcement as per cement polymer composite coating (C.P.C.C.) method developed by C.E.C.R.I. including cleaning the bar by means of any established mechanical or manual method for removing rust and deleterious material, applying rapid setting primer and cement polymer sealing coat of approved and licensed by CECRI including redoing the process if damage occurs during handling, stacking etc. complete. (P. No. 246 Item No. 26.36)
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. & return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) (P. No. 302 Item No. 38.34 BDR)
Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ) Histrength steel with min.550 MPa yield strength, metallic hot dip coated withAluminiumZinc alloy (55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mm center to center. The end rib shall be designed for anticapacity groove. & return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um ZincTin alloy coated, Hex head, selfdrilling screw etc. complete. (weight of profile 4.52 kg/sqm) 301 mm to 600 mm girth (Surface Width). (P. No. 303 Item No. 38.35 BDR)
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (P. No. 223 Item No. 23.04 BDC8)
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 mm to 450 mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and painting complete. (P. No. 225 Item No. 23.12)
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (P. No. 314 Item No. 39.09 BDT-34)
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. (P. No. 329 Item No. 39.58 BDT)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) (P. No. 318 Item No. 39.24 BDT55)
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Architect with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box (P. No. 323 Item No. 39.43 BDT)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete (P. No. 331 Item No. 39.68 BDT)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/Sqm. as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (P. No. 338 Item No. 40.01 BDU1)
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x 5 mm in position with oil painting 3 coats etc. complete (P. No. 333 Item No. 39.79 BDT)
Providing fly ash brick masonry with conventional/ I.S. type fly ash bricks in cement mortar 1:6 in foundation and plinth of inner walls/ in plinth external walls including, bailing out water manually, striking joints, raking out joints and watering complete. (P. No. 254 Item No. 27.01 BDG1)
Providing fly ash brick masonry with conventional/ I.S. type fly ash bricks in cement mortar 1:6 in superstructure including, striking joint stacking out joints and watering and scaffolding complete. (P. No. 254 Item No. 27.05 BDG5): Gorund Floor
Providing fly ash brick masonry with conventional/ I.S. type fly ash bricks in cement mortar 1:6 in superstructure including, striking joint stacking out joints and watering and scaffolding complete. (P. No. 254 Item No. 27.05 BDG5): First Floor
Providing second class fly ash masonry with conventional/ I.S. type fly ash bricks in cement mortar 1:4 in half brick thick wall including, mild steel longitudinal reinforcement of 2 bar of 6mm. Diameter/2 hoop iron strips 25 mm x1.6 mm at every third course, properly bent and bounded at ends scaffolding racking out joints and watering complete. (P. No. 254 Item No. 27.06 BDG7)
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing including all materials , labours, and equipment etc.Complete (P. No. 330 Item No. 39.64 BDT)
Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kota stone should not exceed 0.05% (P. No. 283 Item No. 33.75 BDM)
Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete. b) Granite (P. No.276 Item No. 33.22 )
Providing and laying Antiskid Ceramic tiles of approved quality company RAK / Kajaria / Nitco / Asian or equivalent size 30 cm x 30 cm and confirming to IS 156222006(GroupB IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (P. No. 283 Item No. 33.67 BDM)
Providing and laying ceramic tiles of RAK/ Kajaria/ Nitco/ Asian of having size 30 cm. x 30 cm. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (P. No. 277 Item No. 33.25 BDM13)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. (P. No. 276 Item No. 33.18 BDM22B)
Providing internal cement plaster 12 mm. thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. (P. No. 268 Item No. 32.03 BDL2): Gorund Floor
Providing internal cement plaster 12 mm. thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. (P. No. 268 Item No. 32.03 BDL2): First Floor
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. (P. No. 268 Item No. 32.02 BDL1)
Providing fine cement finish 1.5 mm. thick over green plaster surface including scaffolding, curing etc. complete. (P. No. 269 Item No. 32.21 BDL)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (P. No.269 Item No. 32.11 BDL7): Gorund Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (P. No.269 Item No. 32.11 BDL7): First Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (P. No. 288 Item No. 35.21 BDO 8E): Gorund Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (P. No. 288 Item No. 35.21 BDO 8E): First Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old & new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. (P. No. 291 Item No. 36.12 BDP6) : Gorund Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old & new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. (P. No. 291 Item No. 36.12 BDP6): First Floor
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plastersurface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. (P. No. 288 Item No. 35.25 BDO): Gorund Floor
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plastersurface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. (P. No. 288 Item No. 35.25 BDO): First Floor
Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (P. No. 286 Item No. 35.07 BDO 50
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. (P. No. 264 Item No. 31.09 BDJ)
Providing and laying cement concrete flooring 50 mm thick with 1:2:4 cement concrete laid to proper level and slope in alternate bays, including compaction, filling joints, marking lines to give appearance of tiles of 30 cm x 30 cm. or other size laid diagonally/square etc. finishing smooth (with extra cement) in any colour as directed and curing complete. With Natural Sand. (P. No. 275 Item No. 33.13 BDM7A)
Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete (P. No. 365 Item No.43.05 BDV5)
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete (P. No. 358 Item No. 42.55 BDV)
Providing and fixing 15 mm dia screw down bib / stop tap of brass including necessary socket, union, nut, testing etc. complete ( Prior approval of sample & brand by Architect is necessary before use) (P. No. 345 Item No. 41.40 BDV8)
Providing and fixing screw down 40mm dia meter wheeled stop tap of brass including necessary sockets/union nut complete. (P. No. 346 Item No. 41.47 BDV9)
Providing and fixing European type wall-hung white water closet of Paryware/Hindware with push valve concealed type with cover plate 32mm size of JAQUAR MAKE SERIES FLV-1095 including soil pipe ,vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc. complete. (P. No. 362 Item No. 42.86 BDV)
Providing and fixing 15 mm diameter PVC Aqua kraft type Supreme make or equivalent make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete (P. No. 371 Item No. 43.37 BDV)
Providing and fixing colour glazed earthenware Wash Hand Basin of 55cm x 40cm size including pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including UPVC waste pipe and trap upto the outside face of the wall. Making good damaged surface testing etc. complete. With UPVC Bottle trap. (P. No. 348 Item No. 41.66 BDV30)
Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete (P. No. 350 Item No. 41.80 BDV32)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. (P. No. 351 Item No. 42.02 BDV38)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick masonry, plastering from inside and air tight 75 mm thick RCC cover etc. complete. (P. No. 353 Item No. 42.16 BDV)
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (P. No. 354 Item No. 42.28 BDV 60)
Providing and fixing H.D.P container Syntex or alike one piecen moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (P. No. 358 item No. 42.54 BDV)
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips etc. complete. (P. No. 362 Item No. 42.85 BDV)
Providing and fixing lightening conductor system comprising of errecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2mm thick with multiple points head 1.2mt. long (Heavy Duty) welded or clamped to G.I. pipe pole B Grade 50mm dia. of reqd. length with M.S. round base plate 25cm. diam. and 10cm thick at bottom embeded in cement concrete 1:3:6 foundation of size 45cm diam. x 45cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pit 1.5 metre below ground level with 40 Kg charcoal and salt with alternate layers of charcoal and salt and G.I. pipe 40mm dia. 2mt. length burried in earth upto earthing plate remaining portion above ground level for watering and refilling complete. (P. No. 375 Item No. 44.18 BDW)
Providing and fixing copper strip 25 mm wide and 3 mm thick for lightening conductor including fixing with screws required scaffolding etc. complete. (P. No. 375 Item No. 44.19 BDW)
RWH-Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space)with 40mm size boulders including filling of percolation pit upto 0.5m depth (from bottom up)with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Architect in charge (P. No. 405 Item No. 48.46 )
Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) (P. No. 353 item No. 42.18 BDV45)
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. (P. No. 353 Item No. 42.19 BDV46)
Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of 75,000 litres capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as Stainless steel ladder inside tank and M.S. ladder outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of Acrylic emulsion with silicom additives paint to all exposed surface of structure including Anti-termite treatment shall be given for underground portion of the structure. Notes: 1) The design shall be in accordance with various relevant I.S. specification (I.S. 456/2000, I.S. 875 - 1987, I.S. 3370 - 1965 or revised.) 2) Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade-II M.S. bars shall not be used. 3) Entire structure shall be in M-300 only. 4) The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 5) The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment. 6) The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer-in-charge. If uplifts considered in design, then these rates shall be increased by 7.5%. 7) G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom. 8) For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside. 9) Cost of pump house is not included in these rates. 10) Above rates are applicable for Seismic Zones 2, 3 and 4. 11) 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 12) 10% shall be added for sump if overhead pump house is proposed. Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps. (Page No. 200 MJP CSR 2019-20)
Designing (aesthetically), and constructing RCC elevated service reservoirs of 25,000 litres capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as Stainless steel ladder inside container & M.S. ladder outside, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking providing and applying three coats of Acrylic emulsion with silicom additives to the structure including roof slab, epoxy painting to internal surface and anti- termite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Architect in Charge. Notes: 1) The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.) 2) The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks. 3) For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. 4) Plain round mild steel bars grade-I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed. 5) Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 6) These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity. 7) Staging shall have to be designed with stresses of M-250 concrete for ESR. However all RCC construction should be done in M-300 .Structures in contact with water shall be designed & casted in M- 300 8) These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 9) All conditions given in the Member Secretary's Circular No. MJP / TS-I / 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 10) 75% part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 11) The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipes and valves including cost of jointing materials upto 5 M beyond outer face of outermost column. 12) For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I./M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti- corrosive epoxy treatment from inside and outside. 13) Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item. 14) The rate shall be increased by 30% for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increased by another 10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only be used. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR. 15) The rates are applicable for staging height of 12 M. These rates shall be increased or decreased for per metre variation in this staging height as below : 12 to 16 M staging - 2% per metre 16 to 20 M staging - 3% per metre 20 M and above - 4% per metre For 17 M staging height, percentage calculation will be like below : 12 to 16 M --- 4 x 2 = 8% 16 & 17 M --- 1 x 3% = 3% Total = 11% For 21 M staging height, percentage calculation will be like below : 12 to 16 M --- 4 x 2 = 8% 16 to 20 M --- 4 x 3% = 12% 20& 21 M --- 1 x 4% = 4% Total = 24% 16) Following rates are for seismic zone III. For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR). Notes 1) Conditions from Sr. No. 1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of R.C.C. E.S.R. 2) Conditions from Sr. No. 11 to 16 are for estimation purpose only and shall not appear in the tender. (Page No. 203 MJP CSR 2019-20)
Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of 100 mm dia including railway freight, inspection charges, unloading from railway wagon, loading in to truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) With by pass arrangement - PN-1.6 (Page No. 126 MJP CSR 2019-20)
Providing double flange sluice valve of 100 mm dia. confirming for IS-14846 including worn gear arrangements as per test pressure, stain less steel spindle, caps, including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valve - PN - 1.6 with byepass arrangement (Page No. 127 MJP CSR 2019-20)
Lowering, laying and jointing in position following CI D/F reflex valves, Butterfly valves, and sluice valves of 100 mm dia. including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete ( Rate for all class of valves) (Page No.130 MJP CSR 2019-20)
Providing and supplying Air Valves Double Ball Flanged Type PN 1.6 of 100 mm as per IS 14845-2000 and MJP's Standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including all taxes (central & local), insurance, third party inspection charges, loading, unloading transportation upto departmental store site, etc. complete excluding GST levied by GOI & GOM in all respect etc. complete. (Page No. 131 MJP CSR 2019-20)
Lowering, laying and fixing in proper alignment and position all types of CI Air Valves Double Ball Flanged Type PN 1.6 of 100 mm as directed by Architect including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc, complete (for all class of valve) (Page No. 132 MJP CSR 2019-20)
Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Lift 0 to 1.5 M) (Page No. 33 MJP CSR 2019-20)
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all lead sand lifts including consolidation, surcharging, etc. complete. (Page No. 36 MJP CSR 2019-20)
Providing & supplying in standard lengths ISI mark rigid 110 mm unplasticised PVC pipes Working Pressure 8 Kg./Sq.cm suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 including excluding GST levied by GOI & GOM in all respect, including transportation, frieght charges, inspection charges, loading, unloading, conveyance to the departmental stores / site & stacking the same in closed shed dulky protected from sunrays & rains including cost of jointing material i.e solvent cement, etc. completed (selffit type to be jointed with cement solvent). (Page No. 65 MJP CSR 2019-20)
Lowering, Laying & jointing with 110 mm P.V.C. pipes and specials working pressre 6 to 12.5 Kg./Sq.cm including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete ( with cement solvent joint/ ring fit joint). (Page No. 69 MJP CSR 2019-20)
Providing ISI standard R.C.C. pipes NP-2 (2.50 m length) of 300 mm dia. in standard lengths suitable for either collar joints or rubber ring joints, excluding all statutary duties and taxes such as GST levied by GOl and GOM in all respect, inspection charges, transport to departmental stores/site, unloading and stacking etc. complete as per IS-458/1988 (Page No. 85 MJP CSR 2019-20)
Providing and constructing RCC spiral staircase in M-250 mix concrete at site of work and consisting of central vertical column of 400 mm dia and steps in RCC M-250, tie members at each brace level, RCC parapet wall 80 cm high including cost of all labour and material in volved, cost of scaffolding, centering, shuttering, curing, finishing in CM1:3 proportion including RCC M-250 footing foundation, its excavation, refilling and cleaning the site, etc. complete as per type design, with 3 coats of cement paint. (Page No. 219 MJP CSR 2019-20)
Providing and constructing B.B. masonry valve chamber of 60 x 45 cm internal size and depth upto 0.9 M with precast R.C.C slab cover with 15 cm thick 1:2:4 proportion PCC bedding, excluding excavation, B.B.masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Architect-in-charge. (Page No. 207 MJP CSR 2019-20)
Providing, erecting and giving test of Centrifugal Monoblock pump set two stage 20.00 HP conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. (Page No. 4 MJP Elect/Mech MJP DSR 2019-20)
Electromechanical Work: INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-120 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-150 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-175 / 200 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-80 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for Ceiling- 150 mm PIR thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for Ceiling- 175 / 200 mm PIR thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 150 mm XPS , min 30 kg/cu.m density Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer ,bitumin / bituminous cold compound for proper adhesion to surfaces.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 175 mm XPS , min 30 kg/cu.m density Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer ,bitumin / bituminous cold compound for proper adhesion to surfaces.
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 30 deg C. (Fermond Soupape 2230 -Valve /Equivalent)- 1 no for each Frozen storage chamber. and blast freezers
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 30 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.
PART-2: INSULATED DOORS AND DOCK SOLUTION: Insulated Sliding Doors for Blast Freezers (Manual) With 150 mm thick PIR Insulation Clear opening Size: 1500mm X 2100mm ht Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. Counter frame (if required) shall also be provided at no extra cost. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and shall have provision of self-regulating heat tracing / low voltage heating system. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For processing area to Ante-Room Insulated Doors -Swing type with double shutter 2000 mm x 2600 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For processing area entry, holding area Insulated Doors -Swing type with double shutter 2000 mm x 2100 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
Insulated Sliding Doors for Frozen Food Chambers With 120 mm thick PIR Insulation Clear opening Size: 1500mm X 2600mm ht Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness.Counter frame (if required) shall also be provided at no extra cost. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and shall have provision of self-regulating heat tracing / low voltage heating system. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For Lab, PQ area Insulated Doors - Swing type with single leaf 1200 mm x 2100 mm ht x min 49 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated single leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
DOCK DOOR & SEAL Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca/Eqvt (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK Seal : CUSHION type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Flexible polyurethane foam, covered with PVC / polyester fabric, supporting the vehicle pressures and perfectly sealing the three sides.
DOCK LEVELER Designed for Hydraulic operation as per General technical specification, Acceptable makes: Gandhi Automation/ Metaflex/Infraca/eqvt Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included
Strip Curtains: SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.
For Insulated Sliding Doors for Blast Freezer Suitable for Clear opening Size: 1500mm X 2100mm ht
For FFS 1 Suitable for Clear opening Size: 1500mm X 2600mm ht
For processing area to Ante-Room, Ante-room to dispatch dock, Suitable for Clear opening Size: 2000mm X 2600mm ht
For For FFS ante-room, processing area entry, holding area Suitable for Clear opening size: 2000 mm x 2100 mm ht
For Lab, PQ area Suitable for Clear opening Size: 1200mm X 2100mm ht
PART-3: Refrigeration System for ante-room and Dock Area: AIR COOLED CONDENSING UNITS For Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make scroll compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Ante room in front of Pre-cooling Capacity: 15 KW DesignTemperature: 5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Ante room in front of Pre-cooling (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 15 Evap. Temp. & TD ‘C’: 5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 7900 External sp. Wg, mm: 6 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 15 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation.
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
PART-4: Refrigeration System for Frozen Food Stores and Blast Freezers: AIR COOLED CONDENSING UNITS For Blast Freezer 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make two stage semi hermatic reciprocating compressor/compressors working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, Oil separator with check valve in discharge line,HP/LP Switch,Sub cooler,Oil pr switch MP54 Solenoid valve, Suction accumulator, Vibration eliminator etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Blast Freezer 1,2 ( 2 nos for each ACU): Capacity: 27.5 KW DesignTemperature: (-)36 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls etc shall be included in the cost.
AIR COOLED CONDENSING UNITS For FFS 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make two stage semi hermatic reciprocating compressor/compressors working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For FFS 1,2 ( 2 nos for each Chamber): Capacity: 16.5 KW DesignTemperature: (-)26 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Blast Freezer 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 55 Evap. Temp. & TD ‘C’: (-)36 °C / 6 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 10 mm/12 mm combination Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 61500 External sp. Wg, mm: 30 No of Fans/Unit: 3/4 Fan Motor -kW each: To be Mentioned Air throw -m: 4.5 m Drain pan insulation: Required Drain pan heating: Required Type of Defrosting: Electrical Fan peripheral heating: Required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. False ceiling with min. 60 mm PIR panel with its support structure also shall be considered.
AIR COOLING UNITS - Air Cooling Units for FFS 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type Type of Refrigerant feed: HFO - DX Capacity - 20 kW Evap. Temp. & TD ‘C’: (-)26 °C / 6 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 8 / 10 mm combination Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 17500 External sp. Wg, mm: 7 No of Fans/Unit: 3/4 Fan Motor -kW each: To be Mentioned Air throw -m: 15 m Drain pan insulation: Required Drain pan heating: Required Type of Defrosting: Electrical Fan peripheral heating: Required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction & Liquid line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction, liquid line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 32mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC / GI pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 25 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation. Drain line inside the chamber and 1m portion outside the chamber shall be in GI and shall have heat tracing.
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range) for A.C. units to be placed outside the each cold rooms in ante-room area.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .
Fabrication and Erection of the duct mouthpieces for Air Cooling Units Ducting mouthpieces for Air Cooling Units fabricated from G.S.sheet complete with collars, guide vanes, supports etc. as per approved drawings. This shall mainly be required for frozen food store chambers All ducts shall be fabricated from galvanized steel sheet . All nut bolts and washers shall be galvanized Self tapping screw shall not be used.Duct construction shall, generally, conform to IS-655. All flanged joints shall have neoprene gasket. 0.8 mm thick (22 gauge)
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
PART-5 : VENTILATION SYSTEM FOR PACKHOUSE AND OTHER AREAS
PART IV- VENTILATION SYSTEM Supply air Fans For Processing Hall ,as per the capacity specified below and complete with (a) Fan with direct coupled motor (b) Mounting ring and brackets (c) filters (d) Gravity louvers (e) Bird screen Cap. : 7000 cmh of 2.5 mm wg.sp.
PART IV- VENTILATION SYSTEM Exhaust Fans For Processing Hall ,for single stage evaporative air cooling system as per the capacity specified below and complete with (a) Fan with direct coupled motor (b) Mounting ring and brackets (c') Gravity louvers (d) Bird screen Cap. : 7000 cmh of 2.5 mm wg.sp.
PART III - VENTILATION SYSTEM - Air Curtains for FFS 1,2 Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500 mm x 2600 mm ht
PART III - VENTILATION SYSTEM - Air Curtains for processing area to Ante-Room, Ante-room to dispatch dock Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 2000mm X 2600mm ht
PART III - VENTILATION SYSTEM - processing area entry, holding area Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: :2000 mm x 2100 mm ht
PART III - VENTILATION SYSTEM - Air Curtains for Workers entry,Lab, PQ area etc Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: approx. :1200 mm x 2100 mm ht
PART-6: Processing Equipments: BELT INSPECTION SECTION MOC : SS 304 O/A Length : 8000 mm Conveyer width: 800 mm of belt Belt : PVC with 2 mm thick Powered by : 1 Hp, 3 Ph geared motor Platform : to be provided acceptable make: Fruit technologies/ kailash Enginering/ eqvt. Approved.
PACKING TABLES Function: For manipulation , Handling of Fruits, Pouches, Packing Material. Specifications : • Thick Gauge SS table top and raised edges • Drain outlet at one end , square tube structure Size : 2000 mm x 900 mm x 850 mm (ht) MOC : SS 304 acceptable make: Fruit technologies/ kailash Enginering/ eqvt. Approved.
SCOOPING and INSPECTION CONVEYER Top Conveyer: Complete with side guides Food grade belt with centre trading to avoid shifting of belt during continuous running for carrying whole fruit. Middle Conveyer : Food grade belt on both sides of top conveyer, for feeding scooped material to pulpers. Side tables with waste disposal gravity chutes on both sides of conveyer. The wastage shall be transferred to bottom conveyer through gravity chutes. Operators has to pick up whole fruit from top conveyer for scooping and dropping it on middle conveyer, which then feed to pulp extractor similarly waste disposal through waste disposal chute. Each sides of middle conveyer shall feed to individual machine ( pulper ). Bottom Conveyer: Transferring the waste material ( Custard apple skin) Chain guard, motor shroud, feed hopper, discharge chute etc. Capacity : 500 kg/ hr acceptable make: Fruit technologies/ kailash Enginering/ eqvt. Approved.
Flakes Separator Function- For extraction of pulp suitable for custard apple. Specification - Pulper- mounted on square tube rigid structure Specially designed screen for custard apple Specially designed shaft assembly with brushes & blades for pulper Openable top cover for easy cleaning after batch production Feed hopper, seed discharge chute, and screen Inclined tray for flakes outlet acceptable make: Fruit technologies/ kailash Enginering/ eqvt. Approved.
Electrical Control Panel Electrical control panel shall be manufactured as per approved GA drawings. Electrical panel contains starter for all other motors with respective H.P. with on/off switch, emergency stop button, Push button & relay, RYB indicators & Emergency stop button, 3 ckt energy meter etc.
TWO HEAD POUCH FILLING MACHINEwith hopper M.O.C.: contact parts will be in SS 316 & non contact parts in SS 304.Filling Range: 100 gram to 2000 gram.
PART-7: Miscllanious Items: Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: two side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C MOC Shall have excellent impact strength and high compression resistance.
Miscellaneous Items : PVC Crates suitables for handling fresh fruits Nikamal make Model - JBC 64160 or eqvt.
Miscellaneous Items : Weighing balance in SS construction of 150 Kg. each digital type, Sansui model no:SPP SS 150 / Eqvt
Miscellaneous Items : Lab Equipments of reputed makes a) Temprature Probes to measure temprature of the fruit - 6 nos b) Refractometer to check the total soluble solids - 2 no. c) Calipers to measure size of the fruit - 4 no. d) Differntial Colour Charts to Check Colour of the fruit - 2 no. e) Penetrometer to measure Pulp pressure - 2 no. f) pH measuring probe to measure pH - 2 no. g) Microscope with camera feature - 2 no. h) illuminated magnifier- 1 no h) other related equipments as may be required
Miscellaneous Items : Insect Killer, “Russell” ‘Carolyn’ Glue Board Insect Killer/ Eqvt, Stainless Steel Body 304 with stainless steel screws and stainless steel grills with glue board, suitable mounting arrangment. Confirming to CGMP & food safety standards.
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Supply and Installation of Trolleys for Blast Freezer to be made in complete Stainless Steel (SS304L), structurally sturdy to be able to hold the required amount of produce as per the design oad considerations. The number of trolleys would depend on the final design. The trolley shall have heavy duty and robust wheels for easy movement of trolley with load. Wheel material shall be suitable for working in (-) 30 deg C and ambient on a cyclic basis. The quantity given here is in kg to allow flexibility in design. Typical consideration would be 6 trolleys of 450 kg carrying capacity or 8 trolleys of 350 kg carrying capacity each for one blast freezer.
Wheels for Trolleys: heavy duty castor wheels in PU/SS construction complete with bracket and all relevant accessories. Suitable for use in food applications.
Supply & installation of underfloor vent pipes, Heavy duty PVC pipes min 80mm laid 1000 mm centre to centre below the floor of frozen chamber complete with fittings, required solution for installation of pipes etc. The ends of these pipes to have downward facing Elbow provided with cleanable mesh covers. Pipes should be laid with proper slope for draining condensate, which may be formed in the pipes.
Electrical Work
Supply, Installation, Testing & Commissioning of New CT's & PT's inside 11 KV H.T. metering cubical (Compact Type) approved by MSEDCL/Licensee. all as per electricity board specifications and as per the revised load sanction, Job includes removal of old CT's & PT's and replacing it with new ones. All necessary accessories required for installation such as Cables, Clamps, Connectors, Lugs, Hardware, etc shall be included in Installation rate.
Augmentation of 11 KV/0.433 KV, 160/200 KVA plinth transformer with 11 KV/0.433 KV, 500 KVA transformer. Job includes making necessary changes in foundation so as to install the new transformer. Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 500 kVA with OLTC (On Load Tap Changer), oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1510 Watts at 50% load, 4300 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, Removal and take away existing 11 KV/0.433 KV, 160/200 KVA transformers. Dismantalling of Old HT Cable of 3C x 95 sqmm & LT Cable of 3.5C x 95 sqmm of old Transformer and reterminating above cables to new transformer or Panel. (160/200 KVA transformer price benifit should be passed on to Client)
Supply, Installation, Testing & Commissioning of 3 C x 95 sq.mm. 11 KV XLPE insulated, round armoured, aluminium conductor cable, through provided RCC pipe.
Supply & Installation of heat shrink type 11 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Indoor type ).
Supply & Installation of heat shrink type 11 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Outdoor type ).
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
Same as above but electrode length shall be 3 mts.
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.
Same as above with Earthing strip of 25 x 3 mm Copper.
Supply & Installation of 6" dia RCC half round pipe for covering HT/LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 6" dia RCC round pipe for HT/LT XLPE cables laid for Road Crossing. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 146/150MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 50MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Liaisoning Work for Increase of Existing Sanctioned load from Electricity board & Electrical inspector or any other government authority for sanction of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned for 500 KVA transformer, 200 KVA DG set, Internal & External Electrical Work, Obtaining work completion report from Electrical inspector & board officials. Successfully charging of entire H.T. installation with transformer. Client (Owner) will make all official payments as per the requirement of Electricity board.
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supply, Installation, Testing & Commissioning of 3.5 C x 300 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 3.5 C x 185 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 95 sq. mm. Stranded Aluminium Conductor.
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 300 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 75 mm.
Supply & Installation of 300 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 40/50 mm.
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc.
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Same as above but control shall be two way.
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.
Same as above but on lighting switch board ( Half Pt.).
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of Bell point wiring with 1.5 sq.mm, Bell push button, Bell buzzer all modular typr, PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type bell push and reset type bell with indicator.
Supply, Installation, Testing & Commissioning of telephone point wiring with 2 pair telephone wire, through provided PVC conduit, concealed/surface mounted on the ceiling/wall with modular type RJ11 telephone socket, concealed/surface box, modular surface box etc. ( Telephone wire & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of TV point wiring with RG 6 co-axial cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type TV socket, concealed/ surface box, modular surface plate etc. (RG 6 cable & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of data outlet sockets with CAT 6 UTP cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type RJ 45 data outlet socket, concealed/surface box, modular surface plate and connection at both ends. ( CAT 6 UTP cable & PVC conduit will be measured separately ).
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.
Supply & Installation of 32mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.
Supply & Installation of 32 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. (Measurement of conduit & wires shall be separate).
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.
Same as above but with 6.0 sq.mm
Same as above but with 4.0 sq.mm
Same as above but with 2.5 sq.mm
Supply, Installation, Testing & Commissioning of telephone wires of 2 pair with 0.5 mm dia. through existing PVC conduit.
Supply, Installation, Testing & Commissioning of Jelly filled armoured telephone cable of 10 pair with 0.5mm dia liad through existing HDPE pipes
Supply & Installation of 10 pair krone type telephone junction box.
Supply, Installation, Testing & Commissioning of Co-axial cable low voltage grade RG-11 through existing PVC conduit.
Supply, Installation, Testing & Commissioning of CAT 6 UTP data cable through existing PVC conduit.
Supply & Installation of 100x50 mm PVC plastic trunking with flexible cover, base joint, aluminium clip on partition, end caps, internal angle, clips etc.
Supply & Installation of 'B' grade GI pipe down rod duly painted for fan complete erected with PVC three core flexible cable of 1 sqmm copper PVC wire.
Supply, Installation, Testing & Commissioning of 4 way VTPN MCB DB with double door, comprising of following: Incoming : 63 A 4 pole MCB 10 KA: 1 No. Outgoing : 32 A 3 pole MCB. 10 KA. : 3 Nos. 16 A 1 pole MCB. 10 KA. : 3 Nos.
Supply, Installation, Testing & Commissioning of 6 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA : 1 No. 25 A DP RCCB 30 mA Hpi type. : 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. : 12 Nos.
Supply, Installation, Testing & Commissioning of 4 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA : 1 No. 25 A DP RCCB 30 mA Hpi type. : 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. : 6 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. : 1 No. Outgoing : 10 A 1 pole 10 KA MCB. : 4 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of 25/32 A FP MCB 10 KA 2 Nos.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.
Supply, Installation, Testing & Commissioning of On line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 120 mins battery backup for full load and as per specification, Battery Rack, Interconnecting cables, etc.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 15W LED Recess mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 6W LED Surface mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 4000K)direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Red) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Yellow) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Blue) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of wall mounted 70 watt LED Street Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy >100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >= 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.
Supply, Installation, Testing & Commissioning of Integral LED post top 40 watt fitting, complete with wiring etc.
Supply, Installation, Testing & Commissioning of 1200 mm sweep 5 star rated ceiling fan with double bearing complete with wiring etc.
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 24 points Annunciator - 1 No Stay-put type push buttons. - 4 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 80 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 50 Mtrs
Fire Fighting Work: Supplying, fixing, testing & commissioning of Electric Driven Main Fire Pump suitable for automatic operation and consisting of following: Horizontal type, multistage, centrifugal, split casing pump of approved make, cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2250 lpm at 70 m head conforming to IS 1520 Suitable HP, SQ cage induction motor, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated common base plate, coupling guard; foundation bolts etc., as required with anti vibration pads. Complete.
Supplying, fixing, testing & commissioning of Standby Fire Pump (Diesel driven) with cast iron casing & bronze or phosphor bronze internal parts, complete with coupling guard, foundation,capable of discharging 2250 LPM against 70 metre head against all losses complete with suitable diesel engine, auto start facility with battery, nessesary wiring, fuel tank, exhaust system, guages & wired for automatic start of the water pump on drop of pressure in the wet riser/ hydrant and sprinkler system. The motor starter and pump should confirm to LPA / BSES & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. complete.
Supplying, fixing, testing & commissioning of electric driven pressurization Jokey Pump suitable for automatic operation and consisting of following: Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and floor of 180 lpm at 70 m. head conforming to IS: 1520. Suitable HP, SQ cage induction motor suitable for operation on 415 volts, 3 phase 50 Hz. AC with enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS: 325. M.S. fabricated common base plate, coupling, coupling guard; foundation bolts etc., as required with anti vibration pads.
Fabrication, supplying, fixing, testing & commissioning of Electrical Control Panel of cubical construction, floor mounted type fabricated out of 2mm Thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after treatment process, cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with enclosure protection class IP 42 as required.
Suuplying, Laying of XLPE insulated, PVC sheathed alluminium conductor 1.1 KV grade armoured Cable of following sizes on surface / in existing cable tray suitably clamped as required with glands. 3 ½ core 70 sq.mm
Suuplying, Laying of XLPE insulated, PVC sheathed alluminium conductor 1.1 KV grade armoured Cable of following sizes on surface / in existing cable tray suitably clamped as required with glands. 3 ½ core 25 sq.mm.
Supplying, fixing of 25mm x 5mm GI strip in 40mm dia G.I. pipe from earth electrode as required.
Supplying, laying, testing & commissioning of ‘C’ class heavy duty MS pipe conforming to IS1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including supports, anticorrosive treatment with coal tar / asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia
Supplying, laying, testing & commissioning of ‘C’ class heavy duty MS pipe conforming to IS1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including supports, anticorrosive treatment with coal tar / asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia
Supplying, laying, testing & commissioning of ‘C’ class heavy duty MS pipe conforming to IS1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including supports, anticorrosive treatment with coal tar / asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 80 mm dia
Supplying, laying, testing & commissioning of ‘C’ class heavy duty MS pipe conforming to IS1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including supports, anticorrosive treatment with coal tar / asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 65 mm dia
Supplying, laying, testing & commissioning of ‘C’ class heavy duty MS pipe conforming to IS1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including supports, anticorrosive treatment with coal tar / asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 50 mm dia
Supplying, fixing, testing & commissioning of double flanged metallic expansion joint (expansion bellows) of standard length as per manufacturers specs including provoding necessary rubber gaskets, flanges, nuts, bolts and washers complete as required.150 mm dia
Supplying, fixing, testing & commissioning of double flanged metallic expansion joint (expansion bellows) of standard length as per manufacturers specs including provoding necessary rubber gaskets, flanges, nuts, bolts and washers complete as required. 80 mm dia
Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating including providing necessart rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 150 mm dia
Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating including providing necessart rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 100 mm dia
Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating including providing necessart rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 80 mm dia
Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating including providing necessart rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 65 mm dia
Supplying, fixing, testing & commissioning of Check valve (NRV) of rating PN 1.6 rating including provodong necessary rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 150 mm dia
Supplying, fixing, testing & commissioning of Check valve (NRV) of rating PN 1.6 rating including provodong necessary rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 100 mm dia
Supplying, fixing, testing & commissioning of Check valve (NRV) of rating PN 1.6 rating including provodong necessary rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required. 65 mm dia
Supplying and fixing, testing & ommissioning of `Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required. 150 mm dia
Supplying and fixing, testing & ommissioning of `Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required. 65 mm dia
Supplying, fixing, testing & commissioning of external/internal Hydrants confirming to IS 5290 (Type “A”) Hydrant valve shall be SS single outlet having 80 NB flanged inlet. Outlet shall be oblique female instantaneous type coupling of SS conforming to SS-304 having spring loaded lugs; internal parts shall be of copper or Gun metal. A cap with chain shall be provided on the outlet of the valve. Stand post of 80 NB of suitable length.
Supplying, fixing, testing & commissioning of RRL fire hose pipe (as per IS:636) of 63 mm dia and 15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:636. Hose shall be complete with ISI marked SS-304 male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire
Supplying, fixing, testing & commissioning of 63 mm dia instantaneous pattern, SS short branch pipe (conforming to SS-304),20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supplying, fixing 4 way fire brigade connection of cast iron body with 4 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for 150 mm dia MS pipe connection, conforming to IS 904 as required.
Supplying, fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm, in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Supplying, fixing of pressure switch in the MS pipe line including connection etc., as required.
Supplying, fixing of pressure gauges (Bourden type)
Supplying, Fixing of Weather proof cabinet fabricated from 16 gauge M.S. Sheet with Double glazed door having locking arrangement ,painted "fire Red" with powder coated paint "Fire Hose" written on front including suitable supports to Place 900 mm above ground level ,approximately size 750 x 600 x 250 mm deep ( To house Two lengths of Canvas hose with coupling , branch pipe and nozzle and accessories which includes hammer and set of duplicate keys) for External/Internal Hydrants.
Supplying , fixing of First-Aid-fire Hose reel wall mounting swinging type complete with Standrad fire hose reel with 20 mm dia. High preesure rubber hose 36.5 mtrs. Long with SS nozzle and control valve ,shutoff valve , all mounted on circular hose reel of heavy duty mild steel construction and cast iron brackets. Hose reel shall confirm to IS: 884 -1969 and rubber hose to IS : 5132 . Hose reel shall be connected directly to Wet Riser
Supplying, fixing of Siamese fire brigade inlet connection with 4 instantaneous male inlet coupling as per specifications i/c non return valves but without sluice valves.
FIRE EXTINGUISHERS: Supply & Fixing of ABC type 5Kg. Fire extinguishers (ISI Mark)
Supply & Fixing of CO2 type 4.5Kg. Fire extinguishers (ISI Mark)
Providing and fixing Photo Illuminicent 12x6 inch Exit Signages.
SPRINKLER SYSTEM: Suuplying & fixing of Pendant/Upright Type Standard Response K-80 Sprinklers @ 68º C
Supplying & fixing of Flow Switches.
Supplying & fixing of Air Release Valve 25 mm Dia.
Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. 100 mm dia
Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. 80 mm dia
Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. 50 mm dia
Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. 32 mm dia
Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. 25 mm dia
Supplying, fixing, testing & commissioning of installation control valve of Cast Iron body and brass / bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser / Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 100 mm dia as required.
Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating including providing necessart rubber gasket, flanges, union, nuts, bolts, washers & painting etc complete as required of size 100 mm Dia.
Supplying, fixing, testing & commissioning of gun metal gate valves of following sizes; 25 mm dia for air release + test valve.
Supplying, fixing, testing & commissioning of gun metal gate valves of following sizes; 50 mm dia for drain.
FIRE ALARM & DETECTION SYSTEM: Supplying, fixing, testing & commissioning of 1 loop addressable control panel with loop cards, 230 V ac and sounder circuits with battery back up.
Supplying, fixing, testing & commissioning of Analogue addressable Multisensor detector
Supplying, fixing, testing & commissioning of Analogue addressable Photoelectric Smoke detector
Supplying, fixing, testing & commissioning of Analogue addressable Heat detector with base.
Supplying, fixing, testing & commissioning of Analogue addressable Manual Call Point
Supplying, fixing, testing & commissioning of Analogue addressable Hooter Cum Strobe.
Supplying, fixing, testing & commissioning of Control Module
Supplying, fixing, testing & commissioning of 2C x 1.5 sq.mm Cu. - armoured cable
Supplying, fixing, testing & commissioning of PVC Conduit pipe / Cassing Capping Patti.
Supplying, fixing, testing & commissioning of SMOKE/FIRE ALARM Siren Range 1.0 km.
LAISIONING CHARGES FOR PROVISIONAL FIRE NOC FROM MIDC FIRE OFFICE AND GET DRAWINGS APPROVED BEFORE STARTING WORK AND TO OBTAIN FINAL FIRE NOC
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer . 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
NATHANI PAREKH CONSTRUCTIONS PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid