Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹9.4 L+₹3,127 (0.33%)Accepted-Finance 154 A BARASIROHI NEAR IIT KANPUR KALYANPUR KANPUR NAGAR UTTAR PRADESH 208016 | KANPUR NAGAR | UTTAR PRADESH | 208016 | L2 | Accepted-Finance ok | |
| 3 | L3₹9.4 L+₹5,369 (0.57%)Accepted-Finance | L3 | Accepted-Finance ok |
| Sl No | Description | Qty | Unit | ELECTRO POWER SERVICES AND SOLUTIONS L2 | KPS ENTERPRISES L1 | exSel Corporation L3 |
|---|---|---|---|---|---|---|
| 1.00Scope: Supply , installation and configuration of Gateway for telementary data over IEC104 protocal to SLDC Lucknow and Modipuram at 132kV S/s Colonenganj under ETD GONDA. | ||||||
| 1.01 | Providing & Installation of New Gateway at 132kV S/s Colonenganj under ETD GONDA with following specification as follows -
(1) Multiple-Master Communication capabil
(2) Support IEC60870-5-101/103/104, DNP3serial/TCP MODBUS RTU/ASCII/TCP,IEC62056-DLMS, IEC61850, SNMP, SNTP,MQTT
(3) Data Point Support:-5000
(4) Port Connectors: 4 Serial (RS232/485) and 2 Ethernet
(5) Power Supply (AC-DC) 85-265VAC 50-60HZ or 100-370VDC
(6) Realiability: IEC61850-3 complitant hardware,
(7) Time Sync based on NTP/SNTP/NEMA/Protoco specific Synchronization (IEC104/DNP3.0etc)
Suitable for Existing ALSTOM Make SCADA System as Installed at 132kV S/s Colonenganj under ETD GONDA work Included as Installation & all Software configuration and its testing if required as per site condition. | 1 | Nos. | 2,15,000 ₹2,15,000 | 2,13,500 ₹2,13,500 Lowest | 2,15,000 ₹2,15,000 |
| 1.02 | Following work to be carried out for Lucknow SLDC -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Lucknow
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Lucknow | 1 | Nos. | 99,500 ₹99,500 | 99,400 ₹99,400 Lowest | 1,00,000 ₹1,00,000 |
| 1.03 | Following work to be carried out for Modipuram ALDS -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Modipuram.
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Modipuram. | 1 | Nos. | 99,500 ₹99,500 | 99,400 ₹99,400 Lowest | 1,00,000 ₹1,00,000 |
| 1.04 | IEC61850 based BCPUs. ICD/.CID file configuration of ALSTOM make relays for 132kV & 33kV Feeders.
i). 132kV Feeders-7Nos
ii). 33kV Feeders-12Nos | 19 | Nos. | 8,500 ₹1,61,500 | 8,450 ₹1,60,550 Lowest | 8,500 ₹1,61,500 |
| 1.05 | Supply and Installation of GPS time synchronization receiver with display Suitable to make all BCPUs/Relays must be time synch. | 1 | Nos. | 1,97,500 ₹1,97,500 Lowest | 1,97,500 ₹1,97,500 Lowest | 1,98,000 ₹1,98,000 |
| 1.06 | Providing and installation of the UPS 1KVA of backup of 30min. | 2 | Nos. | 12,300 ₹24,600 Lowest | 12,300 ₹24,600 Lowest | 12,500 ₹25,000 |
Tender Value
₹9.4 L
EMD Value
₹9,411
Closing Date
27 Mar 2026, 12:00 pmClosed
SE ETC Gonda
OFFICE OF SE ETC GONDA, 220 KV SUBSTATION CAMPUS JAIL ROAD GONDA
WORK
2026_UPTCL_1127214_1
09/ETC(GD)/2025-26
Open Tender
Miscellaneous Works
Fixed-rate
30 days
GONDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
EE ETD GONDA
₹9,411
15 Apr 2026
18 Mar 2026
27 Mar 2026
18 Mar 2026
27 Mar 2026
18 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: SUPERINTENDING ENGINEER, ELECTRICITY TRANSMISSION CIRCLE - GONDA.
Name of Work:- Work for installation, supply and configuration of Gateway for telementary data over IEC104 protocal to SLDC Lucknow and Modipuram at 132kV S/s Colonenganj under Electricity Transmission Circle – Gonda.
Tender No: E-Tender No- 09/ETC(GD)/2025-26, Due on 27.03.2026
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work/Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Scope: Supply , installation and configuration of Gateway for telementary data over IEC104 protocal to SLDC Lucknow and Modipuram at 132kV S/s Colonenganj under ETD GONDA. 6Core x 2.5 Sq mm
1.01 Providing & Installation of New Gateway at 132kV S/s Colonenganj under ETD GONDA with following specification as follows - (1) Multiple-Master Communication capabil (2) Support IEC60870-5-101/103/104, DNP3serial/TCP MODBUS RTU/ASCII/TCP,IEC62056-DLMS, IEC61850, SNMP, SNTP,MQTT (3) Data Point Support:-5000 (4) Port Connectors: 4 Serial (RS232/485) and 2 Ethernet (5) Power Supply (AC-DC) 85-265VAC 50-60HZ or 100-370VDC (6) Realiability: IEC61850-3 complitant hardware, (7) Time Sync based on NTP/SNTP/NEMA/Protoco specific Synchronization (IEC104/DNP3.0etc) Suitable for Existing ALSTOM Make SCADA System as Installed at 132kV S/s Colonenganj under ETD GONDA work Included as Installation & all Software configuration and its testing if required as per site condition. 0.0 Nos. Excess(+) Full Conversion INR
1.02 Following work to be carried out for Lucknow SLDC - Work Included:- (a)Complete checking of SAS gateway panel included architecture and settings. (b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Lucknow (c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Lucknow 0.0 Nos. Excess(+) Full Conversion INR
1.03 Following work to be carried out for Modipuram ALDS - Work Included:- (a)Complete checking of SAS gateway panel included architecture and settings. (b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Modipuram. (c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Modipuram. Erection of new 33 KV VCB in proper alignment and cable termination of circuit breaker as per logic for tripping/closing, spring charging/indication/supervision circuit with proper ferruling and checking out of breaker operation from local/remote including earthing & connection of both side jumpers and works related to complete the erection work. All required T&P skilled labours, crane/hydra etc. shall be arranged by the contractor at his own cost. 0.0 Nos. Excess(+) Full Conversion INR
1.04 IEC61850 based BCPUs. ICD/.CID file configuration of ALSTOM make relays for 132kV & 33kV Feeders. i). 132kV Feeders-7Nos ii). 33kV Feeders-12Nos 0.0 Nos. Excess(+) Full Conversion INR
1.05 Supply and Installation of GPS time synchronization receiver with display Suitable to make all BCPUs/Relays must be time synch. 0.0 Nos. Excess(+) Full Conversion INR
1.06 Providing and installation of the UPS 1KVA of backup of 30min. 6Core x 2.5 Sq mm 0.0 Nos. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Note: The Rates quoted against each items/work by Bidders herein shall be inclusive GST i.e. (Basic Rate Per Unit + Tax Amount) as applicable.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_2102352.pdf
techsummary_2102352.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_2102352.xls
BOQ • 0.23 MB
TD09.pdf
Tender Documents • 1.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .