Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.0 LAccepted-AOC 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹45.3 L+₹43,555 (0.97%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹45.8 L+₹89,013 (1.98%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L-3 | Rejected-Finance Being higher bid value | |
| 4 | Rejected-Technical | - | Rejected-Technical being deficient documents | |
| 5 | Rejected-Technical | - | Rejected-Technical Being Un-enlisted in appropriate category. |
Tender Value
₹45.0 L
EMD Value
₹89,980
Closing Date
10 Jan 2024, 6:00 pmClosed
GE Alipore Kolkata
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/ MAINT AND SHIFTING OF WINDOW AC AND SPLIT AC IN COMD HOSP (EC) OLD BLDG P-01, P-02, P-04, P-07 AND P-10 UNDER GE ALIPORE KOLKATA
2023_MES_632538_1
GE/ALP(8286B) KOLKATA OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Alipore Kolkata
Class D Category c (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹89,980
Yes
GE Alipore
3 Feb 2024
13 Dec 2023
17 Jan 2024
13 Dec 2023
10 Jan 2024
27 Dec 2023
13 Dec 2023 - 20 Dec 2023
21 Dec 2023
Amount
Taking down and Servicing of defective split (out and indoor unit) type of AC of 1.5/2 TR capacity of any type/size/make/model including replacement of unserviceable parts and cleaning, washing condenser assembly by chemical, checking, retightening of all electrical connections, complete all as directed by Engineer-in-charge . Note : (1) Spare parts will be measured & paid seperately under relevent items as supply only. (2) Fixing charge of parts / spares are deemed to be included in the unit rate (3) Refrigerant gas shall be measured and paid under respective items
Taking down and Servicing of defective window type AC of 1.5 to 2 TR capacity , any type/ size/ make/model including replacement of unserviceable parts and cleaning and washing, condenser asembly by chemical, checking and retightening of all elecctrical connections, complete all as directed by Engr-in-charge. Note : (1) Spare parts will be measured & paid seperately under relevent items as supply only. (2) Fixing charge of parts / spares are deemed to be included in the unit rate (3) Refrigerant gas shall be measured and paid under resspective items
Material and labour for testing leakage of gas , brazing by oxyaccetelene gas wedling and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of whole refrigerator of any capacity/type and make complete all as directed by the Engr-in-charge. Note :-Refrigerant gas shall be measured and paid as supply only under resspective items
Supply and fixing power unit with 20 Amps starter incl 4 model plate, 20A plug and socket, PVC box for mounting of power unit suitable for 20 Amps power unit and connection of electric supply and testing complete etc as specified and directed.
Material and labour for submain wiring with two single core PVC insulated FRLS cable 4 Sqmm size, stranded copper conductor and drawn through and including surface rigid PVC conduit//casing caping with all accessories along with one continuous earth wire of size single core 4 Sqmm PVC insulated copper conductor and connected to common earth dolly complete all as directed. Note : Two run 4 sqmm cable and one run 4 sqmmm cable includinh one run of PVC conduit shall be measured as single run.
Material and labour for submain wiring with two single core PVC insulated FRLS cable 6.0 Sqmm size, stranded copper conductor and drawn through and including surface rigid PVC conduit/ casing caping of 20mm dia with all accessories along with one continuous earth wire of size single core 6.0 Sqmm PVC insulated copper conductor and connected to common earth dolly complete all as directed. Note : Two run 6.0 sqmm cable and one run 4.0 sqmmm cable includinh one run of PVC conduit shall be measured as single run.
Dismantling and taking down from existing position window type AC 1.5 / 2 Ton capacity and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position by brick work and plastring and distermering work and new position etc all as directed by Engr-in-Charge.
Dismantling and taking down from existing position split type AC of capacity 1.5 / 2 Ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc all as specified and directed.
Taking down and Dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer case and rewiding ,heat burnishing the blower motor with super enamel copper wire of suitablle gauge by taking out burnt winding and cleaning the iron core complete as directed by Engr - in - charge
Supply only following spare parts suitable for window type AC of any make / model 1.5 -2.0 TR capacity
Starting capacitor 80-100 Mfd Make : Keltron / Sarada / Usha
Running capacity 30-36 Mfd Make : Keltron / Sarada / Usha
Overload protector relay as per sample
Potential relay box type as per sample
Thermostate switch Make : Ranutrol / Baba
Blower motor single phase 230 Volt, 50 Hz as per sample
Strainer of capillalry tube as per sample
Hermetic sealed type compressor of capacity 1.5 TR. Make : LG/Kirloskar/ Tecumseh BPL/Hitachi/Higly
Supply only following spare parts suitable for Split type AC of any make / model 1.5/2 TR capacity
Rotary compressor for 1.5 Ton capacity Make : Hitachi / Samsung / LG / BPL/Higly
Rotary compressor for 2 Ton capacity Make : Hitachi / Samsung / LG / BPL /Higly/Voltas
Harmetic sealed compressor for 2Ton Make : Kirloskar / Tecumseh / Carrier /Higly
Harmetic sealed compressor of 1.5 Ton capacity Make : Kirloskar / Tecumseh / Carrier
Single Power contactor suitable for 1.5/2 Ton capacity
Running capacitor 50 Mfd Make : Keltron / Sarada / Usha
Runing capacitor 30-36 Mfd Make : Keltron / Sarada / Usha
Fan motor single phase 230 Volt, 50 Hz as per sample
Strainer of capillary tube as per sample
Sensing unit with complete accessories any make / capacity Make : LG/Samsung / Carrier / Weather Maker
Multi terminal capacitor (50+6/50+4mfd) suitable for Split AC (stating, running and fan combined)
Blower motor Indoor unit single phase 230 V suitable for window type AC 1.5 ton complete all as specified and as directed.
Copper tube 1/4" as per sample
Copper tube 1/2" as per sample
Insulation tube 1/4" as per sample
Insulation tube 1/2" as per sample
Copper tube 5/8" as per sample
Insulation tube 5/8" as per sample
Remote Control suitable for 1.5/2 Ton split / window type AC as per Sample.
Supply only Condenser unit suitable for Split 1.5 /2 Ton AC complete all as specified and as directed.
Supply only outdoor blower fan blade suitable for split AC 1.5/2 Ton complete all as specified and as directed.
Supply only Repaired printed circuit board (non invertor ) for split AC 1.5/2 Ton complete all as specified and as directed.
Repair / maintenance of voltage stabilizer of capacity 5/4 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc complete as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
Repair / maintenance of voltage stabilizer of capacity 2/1 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc complete as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint all as specified and directed.
Supply and filling of Refrigerant Gas R-22/32 in factory sealed cylinder complete all as directed by Engineer-in-charge.
EASTERN REFRIGERATION AND ELECTRICAL CO
RADHA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .