Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹46.7 L Quoted ₹49.4 L | L1 | Accepted-AOC lowest tenderer |
| 2 | L2₹51.4 L+₹2.0 L (4.03%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹51.4 L+₹2.0 L (4.03%) | L2 | Rejected-Finance GREATER THAN L1 |
| 3 | L3₹52.4 L+₹3.0 L (6.16%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹52.4 L+₹3.0 L (6.16%) | L3 | Rejected-Finance GREATER THAN L1 |
| 4 | L4₹55.8 L+₹6.4 L (13.0%)Rejected-Finance | ₹55.8 L+₹6.4 L (13.0%) | L4 | Rejected-Finance GREATER THAN L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical DOCUMENTS NOT FOUND CORRECT |
Tender Value
₹49.6 L
EMD Value
₹1 L
Closing Date
8 Apr 2024, 6:00 pmClosed
Shri Gaurav Tiwari, IDSE, EE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIRS / REPLACEMENT OF TUBULAR STREET LIGHT POLES AND LT UG CABLE FOR EXTERNAL ELECTRIC SUPPLY AT OTM AREAS AT INS SHIVAJI LONAVLA
2024_MES_646048_1
GE/LONAVLA/8228/E8
Open Tender
Civil Works
Item Rate
210 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹1 L
Yes
20 May 2024
12 Mar 2024
10 Apr 2024
12 Mar 2024
8 Apr 2024
26 Mar 2024
12 Mar 2024 - 25 Mar 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard dense soil
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft and loose soil for laying of cable trenches all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pair holes etc n exec 10 sqm on plan and n.exec 1.5 in depth and getting out in road / hard / dense soil
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified.
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
Removing excavated material exc 250m but n.exc 500m and depositing where directed as in soils.
S&F 150mm dia HDPE Pipes PN 10 as in cable trench all as specified and directed
M/L for PCC 1:4:8 type D-2 concrete bed to drain pipes of dia 150mm incl, packing under and haunching against the sides of pipes after they are laid and tested etc complete.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less
M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface of broken boulders
M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Taking out under ground 1.1 KV (E) Grade LT cable of size upto 35sqmm 3.5 Core from pole/trenches/walls / ducts etc., for carrying out repairs , relaying, rerouting, laying back through same / different route after carrying out repair / issue under schedule of credit all as directed by Engineer-in-Charge at site.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core. Including taking down ikd unserviceble cable any size by dismantling of all electrical connection etc all as ditrected.
All as per item No.15 above but of size 16 sq mm 4 core
All as per item No.15 above but of size 25 sq mm 4 core
All as per item No.15 above but of size 25 sq mm 3.5core
All as per item No.15 above but of size 35 sq mm 3.5 core
All as per item No.15 above but of size 50 sq mm 3,1/2 core
All as per item No.15 above but of size 70 sq mm 3,1/2 core
All as per item No.15 above but of size 95 sq mm 3,1/2 core
All as per item No.15 above but of size 120 sq mm 3,1/2 core
All as per item No.15 above but of size 185 sq mm 3,1/2 core
All as per item No.15 above but of size 240 sq mm 3,1/2 core
All as per item No.15 above but of size 300 sq mm 3,1/2 core
All as per item No.15 above but of size 400 sq mm 3,1/2 core
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and as directed.
All as per item No.28 above but for cable of size 70 to 95 sq mm
All as per item No.28 above but for cable of size 120 to 240 sq mm
All as per item No.28 above but for cable of size 300 to 400 sq mm
Supply and laying GI pipe light grade 15 mm dia for protection of servoce connection on pole from bracket to junction box not less than 4.0 mtr length all as specified and directed by Engr In Charge
M & L for GI pipe/ tubes light grade of size 50 mm dia for UG cable protection with all fittings laid in trenches, on poles to crossing the roads/Nalah etc .
Cutting and filling bituminus road as per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
M & L for LT route marker made of 50mm x 50mm x 6mm angle iron ficx on PCC block of size 200 x200mm x 200mm including indicaring LT 1100V U/G Cables and fiximg on ground above the cable of every 50 meter length
Supplying and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 300 x 200x 100 mm with 32 Amp 4way heavy duty terminal block with 6 Amp MCB SP and two number of canle entru gland (stainless steel )of standard size with suitable size clamp to fix with pole incudinmg taking old u/s complete all as directed Make Sintex of equivalent
S & F Outdoor Type, weather and vermin proof Bus bar panel made out of 2 mm thick stainless steel sheet including four pole 200 Amps MCCB 415 Volts 50 Hz with front opening and locking arrangement, 200 Amps capacity aluminium bus bar for phase, 3 No's and 1 No 200 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required height all as specified and as directed by Engr-In-Charge .
M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate with 4.0 mm thick GI wire by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized iron strip 25x4 mm as earthing lead by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
Renewal/ Repairs to LT Panel Board of any size complete as mentioned below:- (I) Repair/ replacement of damaged hinges of each compartment (ii) Taking down existing bus bars cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new s/s nuts, bolts, washers etc. (iii) Replacement of damaged copper flexible cable and fixing new copper flexible cable of suitable size for incoming and out going connections of each MCCB terminals to bus bars. (iv) Replacement of damaged/ worn out/ loose connections/ cable lugs for incoming & outgoing cables. (v) Replacement of u/s CT's, ammeters, Volt meters, Indication Lamps (01 Set each) including provision of new wiring for the same. Note : Ammeters and CT's shall be wired with 2.5 sqmm copper wire. (vi) Replacement of neoprene gasket for all doors of panel board. (vii) Scrubing , cleaning of rust materials with the help of wire brush , emery cloth and Painting of complete panel by applying one caot of red oxide and two coat of approved enamel paint, colour as directed by Engr -In-Charge . Note : i) Cost for replacement of spares are deemed to be included in the quoted rates. ii) The rate shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket with painting to all doors including raising of foundation to 0.3 M height etc. iii) Cost of replacement of MCCB's, Repairs to ACB's not included in the scope of work.
Supply and installation of Earthing rods as per following specifications. (a) Earthing rod 25 mm pure copper hollow Earthing Rod with strip I pipe Design Length 3m. Copper Terminal of 100x50x5. (b)BFC Compound The BFC is carbide based having very high electrical conductivity. BFC having high moisture retaining capacity BFC is hygroscopic, nonmagnetic and non-corrosive in nature and in ROHS compliant (c) Installation The Earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5m The Bore drilling will be done with the help of pneumatic boring machine. 50KG BFC will be placed inthe bore to cover the Earthing rod from all sides. BFC will be poured in slurry form in properly mixed condition Earth pit cover square 300x300x240mm to be provided to cover the Earth pit The Earth pit cover shall be made of Reinforced FRP and should be capable of carrying The weight of 5 tonnes. Make : U- Protect,Ashok,JEFF Techno. Note : Electrode must be tested for short circuit test of minimum 40KA at CPRI/NABL. 2)After installation company testing& checked test with earth value certificate provide by contractor.
Taking down street light fitting /security lights any type from pole carefully and refix the same in its own position including repair and replacement of unserviciable parts and testing complete . NOTE :-(i) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Supply and installation of Hot dip galavanised iron pole 7 mtr long sheet thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate 200x200x12 mm, long weatherproof reinforced door opening with junction box mounting arrangement but including of junction box with 4 Nos aluminium Bus bar and including 1.0 M long single arm bracket made of 40NB B class pipe having top 70 mm, 20 dia threaded made to J shape M20x600mm long steel grade EN8 grade foundation bolts - 4 nos with nuts, templates and all complete as per approved drawing (with internal accessorises like connectors, one run of FRLS PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm 3 core conductor as per required and mcb) . including taking down old rusted pole of any size by digging or cutting all as directed . Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups @ 190 mm c/c as per approved drawing(Including form work). This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC, RCC,Form work and reinforcement shall be deemed to be included in qoted rates.
Supply and installation of Hot dip galavanised iron pole 7 mtr long sheet thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate 200x200x12 mm, long weatherproof reinforced door opening with junction box mounting arrangement but including of junction box with 4 Nos aluminium Bus bar and including 1.0 M long double arm bracket made of 40NB B class pipe having top 70 mm, 20 dia threaded made to J shape M20x600mm long steel grade EN8 grade foundation bolts - 4 nos with nuts, templates and all complete as per approved drawing (with internal accessorises like connectors, two run of FRLS PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm 3 core conductor as per required and mcb) including taking down old rusted pole of any size by digging or cutting all as directed . Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups @ 190 mm c/c as per approved drawing(Including form work). This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC, RCC,Form work and reinforcement shall be deemed to be included in qoted rates.
Shree Ayyappa Engineering
cooltech engineering services
INDIAN AIR CONDITIONING SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .