| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹49.6 LAccepted-AOC | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹50.0 L+₹34,416.10 (0.69%)Rejected-Finance | L-2 | Rejected-Finance Not Being L1 | |
| 3 | L-3₹50.0 L+₹34,931.20 (0.70%)Rejected-Finance | L-3 | Rejected-Finance Not Being L1 | |
| 4 | L-4₹50.0 L+₹36,040.95 (0.73%)Rejected-Finance | L-4 | Rejected-Finance Not Being L1 | |
| 5 | L-5₹52.1 L+₹2.4 L (4.89%)Rejected-Finance | L-5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
2 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
PROVISION OF EQUIPMENT STORE ROOM FOR CONTROL STORES OF VARIOUS AD UNITES DURING ANNUAL AD FIRING AT GSFR ANDCERTAIN SPECIALISED ELECTRICAL WORK UNDER GE I GOS
2023_MES_634183_2
8000/111/2023-24/1010/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
As per tender Documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹96,000
18 Mar 2024
20 Jan 2024
3 Feb 2024
20 Jan 2024
2 Feb 2024
27 Jan 2024
Amount
Surface excavation n.exc 30 cm deep and getting out in Soft/loose soil.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified.
M&L for RCC, (nominal mix) 1:2:4 Type B-1 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed Note - Reinforcement and form work shall be measured and paid separately.
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L for RCC, (nominal mix) 1:2:4 Type B-1 (using 20mm graded aggregate) as in Columns,pillars, piers,posts and struts etc complete all as specified and directed.
Formwork to Square,rectangular or polygonal rough surface of concrete of sides of pillars, posts, struts, piers, columns and stanchions
M&L for RCC, (nominal mix) 1:2:4 Type B-1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L for RCC, (nominal mix) 1:2:4 Type B-1 (using 20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Moorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etcall as specified & directed.
Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete
Removing surplus excavated earth (soil) to a distance n. exc 50 m & Depositing where directed at a level n. exc 1.5 m above the starting point complete
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete
S&F Mild steel TMT bars 8mm dia and over, cut to length, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete
M & L brick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth without using extra cement but using waqter proofing compound complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on concrete surface of ceiling finishing even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall & concrete and applying 2 coats of white wash on walls or concrete surfaces including preparation complete.
M&L for two coats of cement based paint after preparation of new plastered surface complete all as specified
M&L three coats of white wash on new plastered ceiling surface including preparation of surfaces complete all as specified
M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface.
M & L 100 mm thick Cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed.
M & L 50 mm thick Cement concrete type B-1, 1:2:4 using 20 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in plinth protection, surfaces finished even and smooth with out using extra cement all as specified.(Note- Joint 12 mm wide to the full depth of pcc shall be provided at every 3 metres and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. cost of this provision shall be deemed to be included in the quated rate for concrete in plinth protection
M & L for water proofing treatment for roof slabs including crumple joints by applying bitumen primer @ 0.3 ltr/sqm then applying bot blown 85/25 @ 1.20kg/sqm and laying APP modified bituminous 3mm thick with non oven polyester core water proofing membrane laid and bonded to the sub-strata by heat process, over lap shall be sealed by flame torch application not less than 3.2kg/sqm with over lap of 100mm and end lap of 150 mm and APP membrane shall be covered with bituminous based aluminium paint @0.2kg/sqm on top complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:3 on concrete surfaces of roof , surface finished even and rough complete all as specified
Supply only water proofing compound of approved make.
S&F Powder coated Aluminium anodised glazed side hung door with following specifications and making good the adjacent surfaces complete all as specified and directed. (a) Cross section of chowkhat/frame 101.60x44.45x2mm thick (b) Cross section of hanging and meeting style 83x44x2mm thick. (c) Top rail of cross section 114x44x2mm thick (d) Bottom rail of cross section 114x44x2mm thick. (e) Lockingrail (middle rail) rail of cross section 100x44x2mm thick. (f) 5.5 mm thick tinted glass of approved make (g) Aluminium handle elsc type -02 Nos per shutter (inside and outside) (h) Aluminium door stopper heavy duty-01 Nos per shutter. (i) Aluminum tower bolt 200 mm long-01 Nos per shutter (inside) (j) Mortice brass Lock- 01 Nos per shutter with key superior quality make as approved by GE
S&F Powder coated Aluminium sliding glazed windows with three track and three shutter sliding with following specifications and making good the adjacent surfaces complete all as specified and directed. (a) Window frame of Cross section 101 mm x44 mm x 1.5mm thick (b) Three way track for sliding shutters of Cross section 91.8 mm x31.8 mm x1.1 mm thick. (c) Sliding shutters frame of Cross section 40 mm x18 mm x1.1 mm thick (d) 5.5 mm thick tinted glass of approved make (e) IDPE rubber gasket for fixing of glass. (f) Locking cleats per shutter-01 Nos. (g) Sliding rollers per shutter-01 Nos. (h) Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.56mm for shutters-01 Nos (i) Fixing screws for frame with wall per window-08 Nos
S&F 7mm thick aluminium grills of god quality surrounded by aluminium 'C' channel with mesh size 75 X 75mm complete all as specified and directed.
M&L for Removal of existing installed meters with following procedures all as specified and directed:- 1. Manpower deployment for disconnecting the power supply from existing energy meter by carefully opening connection from terminal and depositing into stores for safe custody. 2. Capture the final reading/reading remark from the meters being removed from wall and providing the same to MES for final settlement for all the meters
Supply, Installation, Testing and commissioning of Single Phase dual mode (Credit/Prepay) Smart meter with following Specification. AC Single phase Two wire, Tamper proof, Static Watt-Hour Meter of Accuracy Class 1.0, 240V, 50Hz, Current 10-60Amps conforming to relevant Indian Standards like IS 16444 with dual mode (credit/Prepay) support, Advanced Revenue Protection Features, In Build billind data calculation, Microprocessor based LCD based circuitry. Meter should support the following functionalities. Meter should have load limiting switch and the load setting configurable remote command from base station (HES). Meter should detect Tamper event and Power outage detection and reporting to HES using communication module The advance metering system should have mobile application supporting on android and IOS both, which shows all parameters, Alerts. Meter should transfer the billing and tamper data for bill generation, data analysis and energy accounting to HES using communication module over NBIoT or GPRS(4G). Support 15/30/60 minutes Instantenous data for Voltage, Current, Power Factor, Power, Cummulative Energies and frequency support of 15/30/60 minutes of energy and maximum demand load profile. Meter should have Bidirectional communication module to accomodate NBIoT/GPRS(4G) cellular communication Technology for remote connection/disconnection. Support of meter mode switching (Credit to Prepay and Prepay to Credit) through authenticated command remotely. Metering system is also supplied with Tamper Proof external enclosure box of IP54 or better protection against environmental conditions, which also comes with proper sealing arrangement. Correct and reliable installation of the above supplied metering system by skilled technical staff such that no faults in metering system dur to improper installation. Training to end user on new metering system and working with consumer mobile app. Initial reading data capturing during Installation and providing the same to MES personnel for further record keeping and accounting. SLA driven installation and commissioning work of the metering system. Note: These rates should include the 2 years SIM cards charges including DLP period
Supply, Installation, Testing and commissioning of Three Phase dual mode (Credit/Prepay) Smart meter with following Specification. AC Single phase Two wire, Tamper proof, Static Watt-Hour Meter of Accuracy Class 1.0, 240V, 50Hz, Current 20-100Amps conforming to relevant Indian Standards like IS 16444 with dual mode (credit/Prepay) support, Advanced Revenue Protection Features, In Build billind data calculation, Microprocessor based LCD based circuitry. Meter should support the following functionalities. Meter should have load limiting switch and the load setting configurable remote command from base station (HES). Meter should detect Tamper event and Power outage detection and reporting to HES using communication module The advance metering system should have mobile application supporting on android and IOS both, which shows all parameters, Alerts. Meter should transfer the billing and tamper data for bill generation, data analysis and energy accounting to HES using communication module over NBIoT or GPRS(4G). Support 15/30/60 minutes Instantenous data for Voltage, Current, Power Factor, Power, Cummulative Energies and frequency support of 15/30/60 minutes of energy and maximum demand load profile. Meter should have Bidirectional communication module to accomodate NBIoT/GPRS(4G) cellular communication Technology for remote connection/disconnection. Support of meter mode switching (Credit to Prepay and Prepay to Credit) through authenticated command remotely. Metering system is also supplied with Tamper Proof external enclosure box of IP54 or better protection against environmental conditions, which also comes with proper sealing arrangement. Coorect and reliable installation of the above supplied metering system by skilled technical staff such that no faults in metering system dur to improper installation. Training to end user on new metering system and working with consumer mobile app. Initial reading data capturing during Installation and providing the same to MES personnel for further record keeping and accounting. SLA driven installation and commissioning work of the metering system. Note: These rates should include the 2 years SIM cards charges including DLP period
M&L for Hosting and Configuration of the Web based Software, Website setup, User Credential Creation with following modules & services Capable to connect 2000 number of metering points in the setup (capable to enhance for future expansion) M&L for Consumer and Meter Management Module all as specificied and directed. The Consumer and Meter Management Module would be responsible for creating and managing the consumer information, System should be capable to add/remove the consumers triggered through transfer/service completion of the employee. The module should be capable of supporting following applications. a. Consumer attributes update triggered through authenticated channel b. Replacement and updation of defective meters c. Sanctioned Load/Demand update on request through authenticated channel d. Record keeping of the meters. Tariff Management Modeule: The tariff management module should be capable of keeping the latest tariffs consumer category wise. It will also be able to manage the revisions in the existing tariffs against the Government orders. System should be capable to define and manage the tariff. The module should be capable to add/update the existing tariff category and respective tariffs. The system should be capable to update the tariffs over the air from HES using NBIoT/GPRS(4G) channel. Occupation and Vacation Module : The system should be capable to support the occupation and vacation of the officers as well as other private consumers in the system. Customer App : The occupants officers/customers should be able to view energy data and billing data handy on a mobile app available for android and IOS. The app should also enable customer to purchase the vend token online. Communication : Email or SMS communications to users and consumers User Administration : To be available Note: 1. These rates should include the 2 years cloud charges including DLP period 2. Rates given considering 250 nos meters presently & same can be extended till 2000 nos as required
Deployment of adequate skilled manpower and back end IT infra/ cloud hosted applications for providing following services. A. Skilled manpower to deliver the professional services for better efficiency B. Procurement and deployment of hardwares/accessories like (i) Computers to enable the manpower in executing their duties (ii) Printers to print the bills/tokens (iii) UPS sufficient enough to back the uninterrupted services (iv) Tools and tackles to deliver the services (v) Any need of vehicles for mobility in delivering the services (vi) MES User Training
M/s MAA BHAIRABI ENTERPRISES
M/s Bapujee Builders and Traders
M/S. KISHAN ENGINEERING
HARAGOURI SUPPLIERS
R J ENTERPRISES
V.Venkata Ramaiah
Shree Mahavir Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .