| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹28.1 L+₹2.8 L (11.1%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹29.5 L+₹4.2 L (16.7%)Admitted-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ali Mohammad Baba and Sons L2 | JAIMA ELECTRICALS L1 | SUNIL KUMAR SURI CONTRACTOR L3 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of 500 KVA three phase Servo Stablizer with the following configurations. (Complete scope of work had from SBD) | 1 | Job | 17,60,000 ₹17,60,000 | 14,20,000 ₹14,20,000 Lowest | 17,86,000 ₹17,86,000 |
| 2.00 | 3.5 core Al Cable armoured cable from the Servo stablizer to the point at Pannels 250 sqmm crossection | 75 | Job | 2,700 ₹2,02,500 | 2,106 ₹1,57,950 Lowest | 2,786 ₹2,08,950 |
| 2.10 | 300 crossection | 150 | m | 3,000 ₹4,50,000 | 2,466 ₹3,69,900 Lowest | 3,300 ₹4,95,000 |
| 2.20 | 400 crossection | 75 | m | 3,600 ₹2,70,000 | 3,306 ₹2,47,950 Lowest | 4,000 ₹3,00,000 |
| 3.00 | The work comprises construction of a robust RCC foundation for installation of a 500 kVA, 3-phase automatic servo voltage stabilizer at CHC Gandoh. The foundation is essential to support the stabilizer's operational load and ensure vibration-free, safe functioning of the equipment. The process begins with excavation of earth up to a depth of approximately 1.2 meters, covering a foundation area of 2.5 meters in length and 1.5 meters in width. The excavated pit is properly leveled and compacted. A reinforced cement concrete (RCC) base using M25 grade concrete will be cast with steel reinforcement comprising 12 mm diameter TMT bars spaced at 150 mm center-to-center in both directions to ensure structural strength and load-bearing capacity.
The concrete will be poured in layers, properly vibrated, and cured for at least 7 days. The top 300 mm of the foundation will remain above ground level and be finished with a non-slip surface—either a chequered plate or anti-skid tiles—to prevent slipping hazards. Anchor bolts will be embedded during concreting for securing the stabilizer frame. Provision for cable conduits and earthing pits will be included. The foundation will be designed to support an estimated equipment weight of 1000–1200 kg and withstand weather exposure if installed outdoors. | 1 | job | 25,000 ₹25,000 Lowest | 88,500 ₹88,500 | 78,600 ₹78,600 |
| 4.00 | To maintain continuous power to critical hospital systems at CHC Gandoh, a dedicated bypass and isolation system is integrated with the 500 kVA, 3-phase automatic servo voltage stabilizer (AVR). This setup enables seamless disconnection of the AVR for maintenance or repair without interrupting power supply to vital equipment such as the oxygen generation plant, ICU, and diagnostic units. The system includes an 800 A, 4-pole manual changeover switch, MCCBs on both input and output sides of the AVR for isolation, and interlocked bypass circuitry to prevent backfeed risks. Status indicators (AVR ON, Bypass ON, Mains ON), surge protection devices, and proper earthing are also provided. All components are housed in a weather-resistant IP54-rated enclosure for safe and durable operation. This arrangement ensures operational reliability, flexibility, and adherence to hospital-grade electrical safety standards. The installation includes proper cable routing, terminations, and commissioning as per IS/IEC norms for electrical systems. | 1 | job | 99,500 ₹99,500 | 2,42,000 ₹2,42,000 | 78,600 ₹78,600 Lowest |
Tender Value
₹29.8 L
EMD Value
₹59,640
Closing Date
3 Oct 2025, 12:00 pmClosed
EXECUTIVE ENGINEER MECHANICAL AND HOSPITA
KHELLANI DODA
Installation of 500 KV three phase servo Stablizer for CHC Gandoh SITC
2025_PWDJK_286913_1
MHDD/TS/2025-26/53
Open Tender
Electrical Works
Turn-key
30 days
GANDOH
AS PER SBD
2 documents required · 2 mandatory
₹1,000
EXECUTIVE ENGINEER MECH AND HOSP DIV DODA
₹59,640
13 Oct 2025
4 Sept 2025
3 Oct 2025
4 Sept 2025
3 Oct 2025
4 Sept 2025
Amount
SITC of 500 KVA three phase Servo Stablizer with the following configurations. (Complete scope of work had from SBD)
3.5 core Al Cable armoured cable from the Servo stablizer to the point at Pannels 250 sqmm crossection
300 crossection
400 crossection
The work comprises construction of a robust RCC foundation for installation of a 500 kVA, 3-phase automatic servo voltage stabilizer at CHC Gandoh. The foundation is essential to support the stabilizer's operational load and ensure vibration-free, safe functioning of the equipment. The process begins with excavation of earth up to a depth of approximately 1.2 meters, covering a foundation area of 2.5 meters in length and 1.5 meters in width. The excavated pit is properly leveled and compacted. A reinforced cement concrete (RCC) base using M25 grade concrete will be cast with steel reinforcement comprising 12 mm diameter TMT bars spaced at 150 mm center-to-center in both directions to ensure structural strength and load-bearing capacity. The concrete will be poured in layers, properly vibrated, and cured for at least 7 days. The top 300 mm of the foundation will remain above ground level and be finished with a non-slip surface—either a chequered plate or anti-skid tiles—to prevent slipping hazards. Anchor bolts will be embedded during concreting for securing the stabilizer frame. Provision for cable conduits and earthing pits will be included. The foundation will be designed to support an estimated equipment weight of 1000–1200 kg and withstand weather exposure if installed outdoors.
To maintain continuous power to critical hospital systems at CHC Gandoh, a dedicated bypass and isolation system is integrated with the 500 kVA, 3-phase automatic servo voltage stabilizer (AVR). This setup enables seamless disconnection of the AVR for maintenance or repair without interrupting power supply to vital equipment such as the oxygen generation plant, ICU, and diagnostic units. The system includes an 800 A, 4-pole manual changeover switch, MCCBs on both input and output sides of the AVR for isolation, and interlocked bypass circuitry to prevent backfeed risks. Status indicators (AVR ON, Bypass ON, Mains ON), surge protection devices, and proper earthing are also provided. All components are housed in a weather-resistant IP54-rated enclosure for safe and durable operation. This arrangement ensures operational reliability, flexibility, and adherence to hospital-grade electrical safety standards. The installation includes proper cable routing, terminations, and commissioning as per IS/IEC norms for electrical systems.
Ali Mohammad Baba and Sons (BID ID -2555673)
SUNIL KUMAR SURI CONTRACTOR (BID ID -2565539)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .