Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAdmitted-Finance A 18 SECTOR 136 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | L1 | Admitted-Finance | |
| 2 | L2₹43.5 L+₹42,785.81 (0.99%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹65.6 L+₹22.6 L (52.4%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Montecarlo Limited L2 | BST Infratech Ltd. L3 | R S INFRAPROJECTS PVT LTD L1 |
|---|---|---|---|---|---|---|
| 1.00Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. | ||||||
| 2.00 | High Tensile Steel | 500 | MT | 1,08,933.08 ₹1,28,541.04 | 1,27,000 ₹1,54,580 | 99,194 ₹1,17,048.92 Lowest |
| 3.00 | Mild Steel | 305 | MT | 1,05,042.61 ₹1,23,950.27 | 1,19,300 ₹1,45,494 | 91,853 ₹1,08,386.54 Lowest |
| 4.00 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) | 35 | MT | 1,25,934.42 ₹1,48,602.62 Lowest | 1,28,800 ₹1,56,704 | 1,37,380 ₹1,62,108.4 |
| 5.00 | Sub station structure | 35 | MT | 1,06,339.43 ₹1,25,480.53 | 1,27,000 ₹1,54,580 | 91,853 ₹1,08,386.54 Lowest |
| 6.00Supply of Earthing material of Towers | ||||||
| 7.00 | Pipe Type Set | 96 | Set | 2,927.58 ₹3,454.54 Lowest | 3,310 ₹4,023.8 | 3,291 ₹3,883.38 |
| 8.00 | Counter Poise Earthing set | 50 | Set | 5,650.9 ₹6,668.06 Lowest | 7,010 ₹8,496 | 9,872 ₹11,648.96 |
| 9.00Supply of following Tower Accessories | ||||||
| 10.00 | Danger Plate | 114 | Nos. | 220.46 ₹260.14 Lowest | 420 ₹519.2 | 447 ₹527.46 |
Tender Value
₹94.1 Cr
EMD Value
₹1.9 Cr
Closing Date
7 Nov 2024, 4:00 pmClosed
SE(Contract-I)
New MM Building, Old Power House, Banipark Jaipur-302006.
Construction of various 220/132 kV Transmission Lines in Rajasthan at Nathdwara (Udaipur District) including survey, supply of all equipments/ materials, erection (including civil works), testing and commissioning on turnkey basis
2024_RRVPN_417194_1
SE(C-I)/2024-25/BN-9018002401
Open Tender
Electrical Works
Turn-key
540 days
udaipur
Please refer Tender documents.
18 documents required · 18 mandatory
₹23,600
As per bid specification
₹1.9 Cr
27 Nov 2024
12 Sept 2024
7 Nov 2024
12 Sept 2024
7 Nov 2024
20 Sept 2024
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Sub station structure
Supply of Earthing material of Towers
Pipe Type Set
Counter Poise Earthing set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. **
(i) Disc Insulator - 70 kN
(ii) Long Rod - 70 kN
(i) Disc Insulator - 120 kN
(ii) Long Rod - 120 kN
Zebra Conductor -Al-59
Hardware Fittings for Zebra equivelent AL-59 conductor
Single Suspension H/W fittings for Zebra equivelent AL-59 conductor
Single Tension H/W fittings for Zebra equivelent AL-59 conductor
Double Suspension H/W fittings for Zebra equivelent AL-59 conductor
Double Tension H/W fittings for Zebra equivelent AL-59 conductor
T- Clamp Zebra-Zebra
PG Clamp Zebra-Zebra
PG Clamp 7/3.15 mm E/W
Bolted Type S/T H/W for single Zebra
Bolted Type S/S H/W for single Zebra
Accessories for Zebra equivelent AL-59 conductor
Mid Span Compression Joint for Zebra equivelent AL-59 conductor
Repair Sleeve for Zebra equivelent AL-59 conductor
Preformed Armour Rod for Zebra equivelent AL-59 conductor
Vibration Damper for Zebra equivelent AL-59 conductor
G.I. Earth wire 7/3.15
Strain Assembly for Earth wire 7/3.15 with copper earth Bond
Suspension Assembly for Earth wire 7/3.15 with copper earth Bond
Vibration Damper for Earth wire 7/3.15
Mid Span Compression Joint for Earth wire 7/3.15
Repair sleeves for Earth wire 7/3.15
Any Other item required for successful completion of work
Note: ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
(ii) Hard Rock (with blasting subject to permission or without blasting)
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
(ii) Special Towers for any span including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(iii) 1:2:4 Mix
(iv) 1:1.5:3 Mix
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil. (i)each set by laying 4 wires each 15m long at a depth of 600mm l.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
Erection of special tower (with extension)
Erection of substation structures including leveling, setting of stub & Tighting,Punching of Nuts& Bolts and tack welding upto beam level as per specification.
CONDUCTOR STRINGING: Stringing of Zebra equivelent AL-59 including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
EarthwireStringing :- (A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc.
(i)One No. 7/3.15 mm galvanised wire
Revitment work
(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
Any Other Item
Description of Work / Item(s)
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Sub station structure
Supply of Earthing material of Towers
Pipe Type Set
Counter Poise Earthing set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. **
(i) Disc Insulator - 70 kN
(ii) Long Rod - 70 kN
(i) Disc Insulator - 120 kN
(ii) Long Rod - 120 kN
ACSR Zebra Conductor
Hardware Fittings for ACSR Zebra Conductor
Single Suspension H/W fittings for ACSR Zebra Conductor
Single Tension H/W fittings for ACSR Zebra Conductor
Double Suspension H/W fittings for ACSR Zebra Conductor
Double Tension H/W fittings for ACSR Zebra Conductor
T- Clamp Zebra-Zebra
PG Clamp Zebra-Zebra
PG Clamp 7/3.15 mm E/W
Bolted Type S/T H/W for single Zebra
Bolted Type S/S H/W for single Zebra
Accessories for ACSR Zebra Conductor
Mid Span Compression Joint for ACSR Zebra Conductor
Repair Sleeve for ACSR Zebra Conductor
Preformed Armour Rod for ACSR Zebra Conductor
Vibration Damper for ACSR Zebra Conductor
G.I. Earth wire 7/3.15
Strain Assembly for Earth wire 7/3.15 with copper earth Bond
Suspension Assembly for Earth wire 7/3.15 with copper earth Bond
Vibration Damper for Earth wire 7/3.15
Mid Span Compression Joint for Earth wire 7/3.15
Repair sleeves for Earth wire 7/3.15
Any Other item required for successful completion of work
Note: ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
(ii) Hard Rock (with blasting subject to permission or without blasting)
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
(ii) Special Towers for any span including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(ii) 1:2:4 Mix
(iii) 1:1.5:3 Mix
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil. (i)each set by laying 4 wires each 15m long at a depth of 600mm l.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
Erection of special tower (with extension)
Erection of substation structures including leveling, setting of stub & Tighting,Punching of Nuts& Bolts and tack welding upto beam level as per specification.
CONDUCTOR STRINGING: Stringing of ACSRZebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
EarthwireStringing :- (A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc.
(i)One No. 7/3.15 mm galvanised wire
Revitment work
(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
Any Other Item
Description of Work / Item(s)
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Supply of Earthing material of Towers
Pipe Type Set
Counter Poise Earthing set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. **
(i) Disc Insulator - 70 kN
(ii) Long Rod - 70 kN
(i) Disc Insulator - 120 kN
(ii) Long Rod - 120 kN
ACSR Panther Conductor
Hardware Fittings for ACSR Zebra Conductor
Single Suspension H/W fittings for ACSR Panther Conductor
Single Tension H/W fittings for ACSR Panther Conductor
Double Suspension H/W fittings for ACSR Panther Conductor
Double Tension H/W fittings for ACSR Panther Conductor
Accessories for ACSR Panther Conductor
Mid Span Compression Joint for ACSR Panther Conductor
Repair Sleeve for ACSR Panther Conductor
Preformed Armour Rod for ACSR Panther Conductor
Vibration Damper for ACSR Panther Conductor
OPGW Cable
24 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for 24 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
Joint box (24Fibre)
Any Other item required for successful completion of work
Note: ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
(ii) Hard Rock (with blasting subject to permission or without blasting)
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(ii) 1:2:4 Mix
(iii) 1:1.5:3 Mix
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil. (i)each set by laying 4 wires each 15m long at a depth of 600mm l.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
Revitment work
(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
(C )Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
(E) Brick masonary in foundation & plinth with bricks of class desig nation 75 in cement mortar 1:5 (1 cement : 5 coarse sand)
(F) Brick on edge flooring with bricks of class designation 75 including pointing in cement mortar (1:3) complete laid on 12mm thick bed of cement sand mortar 1:6.
Installation of OPGW
Stringing of 24 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
Installation Hardware set for above 24 Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
JOINT BOX (24 FIBER) OPGW CABLE
Any Other Item
Montecarlo Limited (BID ID -2973984)
BST Infratech Ltd. (BID ID -2959892)
R S INFRAPROJECTS PVT LTD (BID ID -2984041)
BST Infratech Ltd. (BID ID -2959892)
Montecarlo Limited (BID ID -2973984)
BST Infratech Ltd. (BID ID -2959892)
R S INFRAPROJECTS PVT LTD (BID ID -2984041)
BST Infratech Ltd. (BID ID -2959892)
Montecarlo Limited (BID ID -2973984)
BST Infratech Ltd. (BID ID -2959892)
R S INFRAPROJECTS PVT LTD (BID ID -2984041)
BST Infratech Ltd. (BID ID -2959892)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
ilovepdfmerged.pdf
Tender Documents • 6.65 MB
BOQ_750175.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .