Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹31.4 L
EMD Value
₹64,000
Closing Date
30 Jan 2023, 2:00 pmClosed
DY. GENERAL MANAGER
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
Internal/external electrification work of Hostel Block at IDTR Kot Bhalwal Jammu
2023_PWDJK_201350_1
e-NIT No. 21/ELECT of 2022-23 Dt. 30-12-2022.
Open Tender
Electrical Works
Item Rate
90 days
JAMMU
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Financial Controller, JKPCC Ltd.
₹64,000
Yes
Dy. Gen. Mgr. Elect. Unit JKPCC Jammu.
4 Feb 2023
2 Jan 2023
30 Jan 2023
2 Jan 2023
30 Jan 2023
2 Jan 2023
9 Jan 2023
Amount
Sub Head-I(Wiring)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 1.5 SQ.MM + 1 X 1.5 SQ.MM Earth Wire
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire
4 X 10 SQMM + 2 X 6 SQ. MM Earth Wire
3cx1.5 SQMM Copper Cable
3cx2.5 SQMM Copper Cable
Supplying and Fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required
5/6 amps switch
3 Pin 5/6 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.
Supply and laying 25mm PVC Conduit
Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-09 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43)
8 Way Double door D.B
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.
63 Amps/40Amps
Supplying,Installation ,Testing and Commissioning of D.P Pole 220V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value.
Supplying,Installation and Testing of 6mmx600mm Cu. Plate for earthing
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
Providing and Fixing 25 mm x 5 mm G.I Strip in 40 mm dia.fixing on surface of the wall vertical/horizontal etc. as required.
SITC of pre-wired Surface Mounted LED Ceiling Down Lighter Fitting 18 W including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .
SITC of pre-wired Surface Mounted LED batten Light Fitting 1 x 20 W including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .
SITC of 300 mm Exhaust Fan along with connections and Testing
SITC of 1200 mm ceiling Fan along with connections and Testing
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required .
Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the RCC/Hume/DWC/Stone ware/Metal/Pvc Pipe as Required.
3.5 C X 300 Sq.mm A2XFY
3.5 C X 185 Sq.mm A2XFY
4C X 16 Sq.mm A2XFY
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
3.5 C X 300 Sq.mm A2XFY
3.5 C X 185 Sq.mm A2XFY
4C X 16 Sq.mm A2XFY
SITC of 35/40 W LED post top light
Supply and fixing of 75 mm 10 feet pipe for post top lighting with pvc junction box and SP MCB complete with excvation,concreating etc.
Supplying,Installation,Testing and Commissioning of Cubical outdoor Type LT feeder pillar Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars, etc. as required as per the Following Description.(IP:42)(Main Outdoor Feeder Pillar L.T Panel) Incommer :-630A Mccb 4Pole 50k =1 OUTGOINGS :-63A Mccb 4P =6 OUTGOINGS :-240/320A Mccb 4P =2 63 A Spn Mcb=3 Aluminium Busbar 400 Amps FP E-91 E Grade Electrolytic Aluminium Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
M/S KHAN AND CO.
Electromechanics Engineers And Contractors
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .