Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹35.3 L+₹2.4 L (7.42%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.8 L+₹2.9 L (8.85%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹36.3 L+₹3.4 L (10.3%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹37.1 L+₹4.2 L (12.7%)Rejected-Finance 1 111 A VENUGOPAL SWAMY TEMPLE STREET LINGARAJAPURAM BANGALORE 5600 084 | 5600084 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
4 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
SPECIAL TO BLDG OF MEG RECORDS UNDER GE NORTH BANGALORE
2024_MES_645493_1
8442
Open Tender
Civil Works
Item Rate
180 days
BENGALURU
Class D Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹75,000
Yes
12 Jun 2024
7 Mar 2024
11 Apr 2024
7 Mar 2024
4 Apr 2024
21 Mar 2024
7 Mar 2024 - 21 Mar 2024
Amount
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided for complete etc all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each etc complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4.0 Sqm each etc complete all as specified and as directed
Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed
Dismantling timber scantlings in fillet, rail, posts, rafter, purlins etc 40 sq. cm and over in section, in any position as in framed work etc complete all as specified and as directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed
M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of flooring etc complete all as specified and as directed
M&L for 75 mm thick Cement Concrete Type C-1, 1:3:6 (with using 20 mm graded stone aggregate) as in plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade "A" complete all as specified and directed.
M&L for machine presssd pre-cast concrete interlocking coloured paving Block of glass fibre reinforced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment incl 50 mm thick M Sand cushioning and incl demolition of stone slab (Laid bedded and pointed in any mortar) etc complete all as specified and as directed
M&L Pre-cast Cement concrete Type 1:3:6 using (20 mm graded stone aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 incl demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:4) on other than fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
Supply only water proofing compound (Liquid) complete all as specified and as directed.
S&F Factory made 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one or more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
S&F 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one or more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in hold fast and filling of pressed steel chowkat etc complete all as specified and as directed
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed
S&F 35mm thick flush door shutter solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed
S&F Box type Steel Windows/Ventilators double side shutters (Windows side hung type, Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm, windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100mmc/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bar/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) 4 mm thick sheet glass and 0.36 mm dia stainless steel wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose . (Note : All Windows/Vent design as per CECZ TD drg No 539)
S&F 4mm thick sheet glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares n exc 0.50 sqm in each pane complete all as specified and as directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed
S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed
S&F 150 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed
M & L Non - skid Ceramic coloured (Joint Free) tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed
All as per item No 27 above, but as in skirting incl backing coat 10 mm thick in CM 1:3 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed
S & F 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking down existing GI/CPVC pipe line etc complete all as specified.
S & F 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking down existing GI/CPVC pipe line etc complete all as specified.
S&F in repairs rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 1000 ltrs incl 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic etc complete all as specified and directed
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
S&F Steel work as in tubular trusses as in columns, rafters, purlins etc. complete using ERW or induction butt welded tubes etc complete all as specified and as directed. Confroming to IS 1161-1979 grade St-240
M&L rolled MS sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality-A etc complete all as specified and as directed
S&F in repair Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws etc complete all as specified and as directed
S&F in repairs Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in ridges / valley to wall, fixed with self tapping etc complete all as specified and as directed
S&F in repairs false ceiling with GI grid suspended system of size 600X600mm standard section consisting of main runner main tee and cross, Tee wall and wall angle as per manufacture instruction / catalogue, ceiling suspended with 3 mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (Main corner, cross tee& wall angle of MS galvanized with PPPCGS) incl 4 mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling etc complete all as specified and as directed
M&L for Providing precast cement concrete, Type B-1 (1:2:4) (with using 20 mm graded stone aggregate) in windoor, door cills, lintels, bressumers, steps, quoin blocks (for use with masonry) set in CM 1:6 incl demolition of existing RCC Slab of any description and in any position etc complete all as specified and directed. Note : Reinforcement steel will be measured and paid separately.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
Complete removal exising treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc complete all as specified and as directed
M&L for 1mm thick wall care putty on wall including preparation of surface with sand paper etc to obtain smooth surface etc complete all as specified and as directed
M&L for Preparing new plastered surface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of primer etc complete all as specified and as directed
M&L for Preparing Old plastered surface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of primer etc complete all as specified and as directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint (Apex Ultima) of required shade (Company Depot Tinted) with silicon additives coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc complete all as specified and as directed
M&L for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
S&F in repairs stainless steel decorative curtain rod of 25 mm bore with wood finishes (weight not less 400 gms per running meter) incl fancy finale caps cap (02 nos in each curtain rod) etc complete all as specified and as directed
S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed
M&L for 10 mm thick in CM (1:3) as in screed bed over concrete surface mixed with water proofing compound to receive water proofing treatment etc along as specified and directed. Noted : WPC Shall be measured and paid seperately
M&L for removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and 3 mm thick APP modified water proofing membrane, weight not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm incl taking down existing roof treatment etc along with cement plastering etc complete all as specified and directed.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of exc 1.0 Km but not exc 1.50Km , beyond the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 Samm single core PVC insulated unsheathed cable 1100 volts gradel muti stranded with FRLS copper conductor conforming to IS 694 drawn through and ind non-metalic rigid PVC conduit medium grade ISi marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal / modular concealed on walls including plastic / heylam laminated sheet top cover 3 mm thick / modular frame and cover of suitable module fixed with cadmium platedison screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Samm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dall all as snecified and as directed for the following One light point controlled by one switch
As per item No. 52 above but for One fan point controlled by one switch / regular
As per item No. 52 above but for One light point controlled by 2 way switch
As per item No. 52 above but for One 3 pin socket out let 5 Amps on independent board
As per item No. 52 above but for One 3 pin socket out let 5 A on same board
Point wiring concealed complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for item No 52 to 57:- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (ii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items.
Provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity drawn through existing conduit including removing of unsv submain wiring complete. Note:- 3 runs of cable will be measured as unit length.
Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. Note:- 3 runs of cable will be measured as unit length.
Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic riaid PVC conduit and conduit accessories all as snecified and as directed. Note:- 3 runs of cable will be measured as unit length.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, all as specified and as directed.
S&F in repairs wall mounted LED batten fitting 20W, extruded aluminium heat sink provided for efficient heat dissipation & intgrated electronic driver, complete with all accessories internaly prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including flourescent tube. Bajaj Cat Part No. BCLAB 20W LED PS or techno commerical equivalent at approved makes.
S&F switch piano, flush button single pole, 230V 5 Amps one way.
S&F ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks.
S&F switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose.
S&F switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose.
S&F in replacement of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
S&F in replacement of MCB SPN 240 volts 32 Amps 'C' curve type complete all as specified and as directed
S&F in replacement of MCB single pole 240 volts 5 to 32 Amps 'C' curve type complete all as specified and as directed
S&F in replacement of MCB TPN 415 volts 10KA 'C' curve 63 Ampsa 'C' curve type complete all as specified and as directed
S& F in replacement of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar with IP42 protection as specified and as directed.
S& F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar with IP42 protection as specified and as directed.
S& in replacement of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-l 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and directed
Supply & Fix in repairs Electric storage water heater of 25 Liters capacity, 5 star rated, 2 KW heating element, made of ABS plastic body, thermostat etc including inlet and outlet flexible cold and hot pipes with electrical connection all as specified and directed. Make CALDIA of BAJAJ or techno commerical equivallant in Havells/Racold
S&F 2' x 2'Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make Bajaj cat part No. BZRSQL 43L XE WH OD SD or techno commerical equivalent of approved makes.
Replacement of outdoor type LED security light fitting of 30 watts comprising of epoxy powder coated hsg enclosed with glass cover in frame, with protection complete with all accessories and lamp colour white and fixing all as specified and directed. Make Bajaj Cat Part No. ENXT P 30L WH PO PC SD or equivalent approved makes & model
S& Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bida complete all as specified and directed
Taking down unservieable Fan,sealingcable end, dismantling blades and removing fan and complete servicing and refixing the same.
S&F in replacement of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs with IP42 protection as specified and as directed.
Supply & laying & fixing GI pipe medium grade size 20 mm bore with all necessary fittings fixing on wall ceiling or laid in trenches/under floors.
M&L for gun metal gate valve with iron wheel head screwed both ends for iron pipe fixed for size 20mm bore dia
S&F Ball brass valves, 25mm dia high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule all as directed
Excavation in trenches in hard/dense soil, not exc 1.5 mr wide and n exc 1.5 mr in depth; for foundation, laying pipes/elect cables etc, and getting out.
Supply and spread river sand to required width at bottom and top for cable cushioning (not less 18 cm thick in layer after punning) all as specified in SSR Part-l. Note : Punned thickness will be measured for payment.
Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engineer-in-charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified in soft / loose / hard / dense soil
Removing excavated materials of soil not exc. 50 mr and depositing where directed at a level not exc 1.5 mtr above the starting point
S&F Mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia.
M&L for laying, jointing, testing cable XLPE insulated, armored and PVC sheathed of 1100 volts grade and aluminum conductor confirming to IS 7098 laid in trenches/through pipe/floor/fixed wall etc complete all as specified and directed for size of cables 50 Sqmm 3.5 core stranded conductor
B5BUILDING SOLUTIONS
M/S SIRI BUILDERS
Sreyas Enterprises
S S CONSTRUCTIONS
ABHISHEK CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .