Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹24.4 L+₹1.0 L (4.46%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹24.6 L+₹1.3 L (5.45%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹24.9 L+₹1.6 L (6.68%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹29.9 L+₹6.6 L (28.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
19 Sept 2022, 6:00 pmClosed
Lt Col Aditya Gorhe
GE Utility Bathinda Mil stn
SPECIAL REPAIR / REPLACEMENT OF BER SUMMER APPLIANCES AND PROVISION OF THREE PHASE ELECTRIC SUPPLY FOR PHOSPHATING PLANT AT BATHINDA UNDER GE (U) BATHINDA.
2022_MES_546314_1
8660/2022-23/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class D cat c i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹52,000
Yes
4 Oct 2022
19 Aug 2022
21 Sept 2022
19 Aug 2022
19 Sept 2022
3 Sept 2022
Amount
SCHEDULE A PART I Supply, installing , testing and commissioning of split type AC 1.5 tonne (indoor / out door unit with copper tubes of evaporator and condensor complete) cooling capacity not less than 5000 Watt (Minimum) with 5 star BEE rating 2022, inverter technology, cordless remote control unit and with in built air ioniser and plazma filter for batter indoor air quality with stand for outdoor unit, 230 Volt, 50 Hz, single Phase complete all as per maunfacturer instruction and direced by Engineer-in-Charge. Note:- Copper pipe, insulation material, PVC clamps , outdoor unit stand and water pipe for condensate as per requirement will be arranged by the contractor and the cost of the same are included in this item and nothing shall be paid extra on this account.
Supply, installing , testing and commissioning of split type AC 2 tonne (indoor / out door unit with copper tubes of evaporator and condensor complete) cooling capacity not less than 6000 Watt (Minimum) with 5 star BEE rating 2022, inverter technology, cordless remote control unit and with in built air ioniser and plazma filter for batter indoor air quality with stand for outdoor unit, 230 Volt, 50 Hz, single Phase complete all as per maunfacturer instruction and direced by Engineer-in-Charge. Note:- Copper pipe, insulation material, PVC clamps , outdoor unit stand and water pipe for condensate as per requirement will be arranged by the contractor and the cost of the same are included in this item and nothing shall be paid extra on this account.
Supply, installing , testing and commissioning of refrigerator electric driven (Single phase, 230 Volts, 50 Hz) of capacity 310 litres (Minimum) double door, 3 star rating including all built in accessories complete all as directed.
Supply, installing , testing and commissioning of refrigerator electric driven (Single phase, 230 Volts, 50 Hz) of capacity 165 litres (Minimum) single door, 3 star rating including all built in accessories complete all as directed.
Supply, installing , testing and commissioning of deep freezer electric driven (Single phase, 230 Volts, 50 Hz) with hard top single door, storage capacity 300 litres (Minimum) including all built in accessories complete all as directed.
Supply, installing , testing and commissioning of water cooler fully stainless steel, electric driven (Single phase, 230 Volts, 50 Hz) having approximate storage capacity 80 litres and normal cooling capacity of 40 litres per hour complete all as directed.
Supply, installing , testing and commissioning of water cooler fully stainless steel, electric driven (Single phase, 230 Volts, 50 Hz) having approximate storage capacity 120 litres and normal cooling capacity of 60 litres per hour complete all as directed.
Supply, installing , testing and commissioning of water cooler fully stainless steel, electric driven (Single phase, 230 Volts, 50 Hz) having approximate storage capacity 150 litres and normal cooling capacity of 150 litres per hour complete all as directed.
SCHEDULE A PART II Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.5 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed.
All as per serial item No 10 above but sectional area 25 Sq mm 4 core.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm complete all as directed.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
Supply and laying or fixing GI tubing light grade 80 mm dia for cable protection including fitting under road / across the drain or nallah / laid in trench complete all as specified and directed by Engineer-in charge .
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe up to 150 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge. Note : Galvanised steel light grade pipe shall be paid under respective items.
Cutting road, demolition of concrete (Un reiforced) in ground floor and paving thickness not exceeding 15 cm (below or above ground level), taking out old LT under ground cable of any size any description and old pipe, relaying the taking out old serviceable cable and pipe from this job or new cable and pipe in lieu of old unserviceable cable and pipe including material and labour for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate for making good and matching the existing surface complete all as directed. Note: (a). New GI pipe and UG cable if required shall be measured and paid separately under respective items.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including 32 x 6 mm GI strip upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion and including demolition of old existing one complete all as specified and shown on plate No 3 of SSR Part-I 2009.
Ganga Enterprises
M/s NIRMAN BUILDERS
UNITED ENGINEERING CORPORATION
M/s Kataria Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .