Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC RATES ARE REASONABLE | |
| 2 | L2₹12.2 L+₹10,544.58 (0.87%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹12.3 L+₹17,845.95 (1.47%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹12.3 L+₹18,360.58 (1.52%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹12.3 L+₹21,939.17 (1.81%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹11.5 L
EMD Value
₹23,700
Closing Date
20 Jul 2021, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
PROVN OF COVERED SHED WITH HARD STANDING AT LEBONG UNDER AGE (I) DARJEELING.
2021_MES_455619_1
CWE/136-WE/23 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
DARJEELING
Class E, Category a (i)
8 documents required · 8 mandatory
₹500
AGE (I) DARJEELING
₹23,700
Yes
28 Jul 2021
29 Jun 2021
21 Jul 2021
29 Jun 2021
20 Jul 2021
13 Jul 2021
29 Jun 2021 - 6 Jul 2021
Amount
M & L for surface dressing n exc 15 cm deep in soft / loose soil complete all as specified and directed.
M & L for excavating in post holes (or similar holes) in soft / loose soil each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.(Note:- The unit rate shall not be included if posts with pointed ends are directed to be driven into the ground).
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.(Note:- (a) Unit rate shall include for dressing/trimming sides and levelling/grading and ramming of bottoms of excavation.(b) The depth for any particular length of an excavation for the purpose of lift shall be the average depth at two ends).
M & L for returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and directed.(Note:-Measurements shall be those of the borrow pits,trenches, etc. from which the material is obtained. If this is found difficult or impracticable, measurements of the finished embankment, traverse of earth filling shall be taken after consolidation and 10% deducted to allow for increase in bulk after excavation. No deduction shall however be made in case of consolidated fills in confined places such as floors. Where the consolidation is done by heavy mechanical machinery or to the specified standard proctor density under optimum moisture conditions, deduction shall be 5 percent).
M & L for Removing of excavated materials of soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.(Note:-(a) The removal of spoil resulting from excavation performed by the Contractor shall be paid for, on the basis of solid contents measured before excavation. If measuring of the solid contents is found difficult or impracticable, the following percentage deductions shall be made to arrive at equivalent solid contents :- (i) 10 per cent deduction in all cases of consolidated fills except where the consolidation is done by heavy mechanical machinery or to the specified standard proctor density not less than 95 per cent under optimum moisture conditions, in which case the deduction shall be 5 per cent.(ii) No deduction shall be made in the case of consolidated fills in confined situations like floors.(iii) 20 per cent deduction when spoil excavated from soft/loose soil or hard/dense soil is measured in loose stacks or in carts or lorries. (iv) No deduction shall be made when spoil excavated is sand.(v) 50 per cent deduction when spoil excavated from soft/disintegrated rock or hard rock is measured in loose stacks or in carts or lorries. (b) In working out lead for large areas of excavation, the excavated areas shall be divided into suitable blocks and for each block the distance from the centre of block to the centre of placed earth pertaining to the corresponding block shall be taken as lead.(c) Theunit rates for removal of spoil include for loading into and unloading from barrows, carts, baskets, etc., or mechnical transport vehicles. In the case of spoil heaps which, in the opinion of the GE, have consolidated and require loosening before removal half the rate for rough excavation in soft soil shall be allowed in addition. However, this additional payment shall not be permitted for spoil heaps requiring loosening due to Contractor’s default. Decision of GE whether a spoil heap needs loosening or not, shall be final and binding.(d) Removal shall be assumed to be done by the shortest practicable route, and payment shall not necessarily be made for the route actually taken. No additional payment shall be allowed for roads in bad repair,gradients, or carting over consolidated ground .(e) In case excavated materials are removed to the place of use or disposed directly without being first placed clear of the edge of excavation, no adjustment shall be made in the unit rates for removal of spoil.).
M&L hardcore of broken stone boulders gauge n exc.63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.(Note:-Measurements for item shall be those after consolidation).
M&L for providing 100 mm thick Cement concrete type D- 2,1:4:8 (40mm graded aggregate) In sub base of flooring Hard Standing complete all as specified and directed.(Note:-(a) The unit rates of cement concrete in flooring include for:- (i) Use and waste of form work/screed strips and to divide the area in panels. Where dividing strips are used, these shall be measured separately,without any price adjustment.(ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers,treads, landings and the like.(b) Different layers of cement concrete floors shall be measured separately, unless laid monolithically).
M & L for providing 75 mm thick pcc type B-1 1:2:4 ( 20 mm graded aggregrate) as in base for flooring for hardstanding complete all as specified and as directed .(Note:-(a) The unit rates of cement concrete in flooring include for:- (i) Use and waste of form work/screed strips and to divide the area in panels. Where dividing strips are used, these shall be measured separately,without any price adjustment.(ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers,treads, landings and the like.(b) Different layers of cement concrete floors shall be measured separately, unless laid monolithically).
M&L fir PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation filling and mass concrete completed all as per specified and directed.
S & F hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.(Note:- The unit rate includes for riveting and/or welding as directed and fixing with screws, bolts, etc. complete).
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)forming holes, without any attachment Fe 410 -W (Gde-E- 250)quality- , complete all as specified and directed.(Note:-(a) All rolled steel section shall be of dimensions and weights as indicated and of one length within the usual rolling limits.(b) The unit rate include for cutting to dead length where required, notching, drilling, fitting,riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging,plumbing, truing up and fixing complete).
M & L preparation of steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.(Note:-The unit rate include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete).
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long and 11 to 15mm diameter of neck complete all as specified and directed .(Note:-Length of ordinary bolts shall be measured from the underside of the head to the end of shank; length of double ended bolts and lewis bolts shall be measured overall).
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpaas in roof covering / cladding to wall, fixed with self tapping screws as specified.
Supply and fixed pre-painted galvanised aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering/Cladding to wall, fixed with self tapping screws as specified.
M&L for brickwork with Fly Ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified.
M&L for rendering 15 mm thick on brick masonry walls other than fair faces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of White wash on walls complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick masonry wall surface in CM 1:4 (with WPC), finished even and smooth without using extra cement complete all as specified and directed.
Supply only WPC (best quality) of approved make compete all as specified and directed.
M&L PCC 1:3:6 , 75mm thick type C2(using 40 mm graded stone aggregate) as in plinth protection complete all as specified and directed.(Note:-(a) The unit rates of cement concrete in flooring include for:- (i) Use and waste of form work/screed strips and to divide the area in panels. Where dividing strips are used, these shall be measured separately,without any price adjustment.(ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers,treads, landings and the like.(b) Different layers of cement concrete floors shall be measured separately, unless laid monolithically).
M&L PCC 1:3:6 , 75mm thick type C2(using 40 mm graded stone aggregate) as in plinth protection complete all as specified and directed.(Note:-(a) The unit rates of cement concrete in flooring include for:- (i) Use and waste of form work/screed strips and to divide the area in panels. Where dividing strips are used, these shall be measured separately,without any price adjustment.(ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers,treads, landings and the like.(b) Different layers of cement concrete floors shall be measured separately, unless laid monolithically).
M&L PCC 1:3:6 , 75mm thick type C2(using 40 mm graded stone aggregate) as in plinth protection complete all as specified and directed.(Note:-(a) The unit rates of cement concrete in flooring include for:- (i) Use and waste of form work/screed strips and to divide the area in panels. Where dividing strips are used, these shall be measured separately,without any price adjustment.(ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers,treads, landings and the like.(b) Different layers of cement concrete floors shall be measured separately, unless laid monolithically).
S&F PVC (SWR) gutter drain pipe, 180mm bore complete all as specified
S&F 180mm PVC (SWR) joint socket complete all as specified
S&F 180mm PVC (SWR) joint tee complete all as specified
S&F 180mm PVC (SWR) joint tee with end cap complete all as specified
S&F 180mm PVC (SWR) pipe clamp complete all as specified
S&F rain water drainage pipes PVC(SWR) pipes single socketed 110mm bore in any length with rubber rings joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed.(Note:Punned depth should be taken during measurement).
Supplying & laying Fly Ash Bricks of best quality available Old size bricks laid flat for protection of UG Cable completeall as specified and directed.
Supply and lay in replacement of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 16 Sqmm 2 Core laid in trenches/along the wall/pole including making all connections complete as required at site and as directed.
M&L for cutting existing road/hard standing not exc 20 x 20 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 20 cm from top using PCC 1:3:6; including removal of surplase soil complete all as directed.
Supplying and fixing nominal bore, light grade, Galvanised mild steel pipe /tubing of size 32 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts, nuts and washers as for cable proction complete all as specified and directed for followig sizes. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule):-
M&L for point wiring in PVC casing & caping of required size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade complete with all fittings such as Elbow, bends, junction boxes, saddles incl PVC board (ISI Mark) and screws and rawalplug etc including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to One light/fan/bell point controlled by one ,one way switch .
M&L for point wiring in PVC casing & caping of required size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 2.5 sqmm nominal cross sectional area 1100 volts grade complete with all fittings such as Elbow, bends, junction boxes, saddles incl PVC board (ISI Mark) and screws and rawalplug etc including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to the following :- (a) For socket out let, 15/16 Amps on independent board with 2.5 Sqmm size cable and 1.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed by Engr - in - charge.
S&F for sub main wiring with two single core 4.0 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
S&F Decorative box type fitting suitable for not less than 4' LED Tube Rod and including bipin holders,connector block,Driver etc.complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and PVC square blocks for fixing LED Fitting all as directed.(Make:M/s Simoco Telecommunications (South Asia) Ltd/M/S Jaquar & Company Pvt Ltd/M/s HPL Electric & Power Ltd/M/S Eveready Industries India Ltd/M/S Crompton Greaves Consumer Electricals Ltd/M/S Halonix Technologies Pvt Ltd/M/S Century LED Ltd (Brand MAGIK)/M/S C&S Electric/M/s Panasonic Life Solutions India Pvt Ltd (Brand: Panasonic)/M/s Dhanashree Electronics Ltd (Brand: RASHMI)/M/s SORIL Infra Resources Limited/M/s Syska LED Lights/M/s Surya Roshni Limited (External / Internal)/M/s Orient Electric Limited (a CK Birla Group Company)
S&F of LED Tube Rod 1 x 20 W 4feet, 230V complete all as directed.(Make:M/s Simoco Telecommunications (South Asia) Ltd/M/S Jaquar & Company Pvt Ltd/M/s HPL Electric & Power Ltd/M/S Eveready Industries India Ltd/M/S Crompton Greaves Consumer Electricals Ltd/M/S Halonix Technologies Pvt Ltd/M/S Century LED Ltd (Brand MAGIK)/M/S C&S Electric/M/s Panasonic Life Solutions India Pvt Ltd (Brand: Panasonic)/M/s Dhanashree Electronics Ltd (Brand: RASHMI)/M/s SORIL Infra Resources Limited/M/s Syska LED Lights/M/s Surya Roshni Limited (External / Internal)/M/s Orient Electric Limited (a CK Birla Group Company)
S & F Switch Piano flush button single pole one way 5 Amp, 240 volt all as specified.
Supply & Fix 120 Watts LED integral floodlight luminaries, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light sourcewith IP 66 protection and including driver unit etc all as directed.(Make:M/s Simoco Telecommunications (South Asia) Ltd/M/S Jaquar & Company Pvt Ltd/M/s HPL Electric & Power Ltd/M/S Eveready Industries India Ltd/M/S Crompton Greaves Consumer Electricals Ltd/M/S Halonix Technologies Pvt Ltd/M/S Century LED Ltd (Brand MAGIK)/M/S C&S Electric/M/s Panasonic Life Solutions India Pvt Ltd (Brand: Panasonic)/M/s Dhanashree Electronics Ltd (Brand: RASHMI)/M/s SORIL Infra Resources Limited/M/s Syska LED Lights/M/s Surya Roshni Limited (External / Internal)/M/s Orient Electric Limited (a CK Birla Group Company)
S & F Switch Socket combination with encloser 5 in 1, 15 Amps, 6 pin multipurpose, flush type, 230 Volts
M & L for Ceiling rose, PVC/polycarbonate, 3 terminals and 240 Volts complete all as specified as directed.
S & F in repairs MCB DB 8 way SPN, single door, vertical type, IP - 53 with 200 Amps rated bus bar, AC and connecting up complete all as specified. ( Make -M/s Larsen & Toubro Ltd/M/s Havells India Ltd MCB (Brand-Max3, EURO-II), MCCB (Brand- HIM & HIX)/M/s Panasonic Life Solutions India Pvt Ltd (Switch Gear: Panasonic)
S & F MCB SP 6 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified. Make -M/s Larsen & Toubro Ltd/M/s Havells India Ltd MCB (Brand-Max3, EURO-II), MCCB (Brand- HIM & HIX)/M/s Panasonic Life Solutions India Pvt Ltd (Switch Gear: Panasonic)
S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified. Make -M/s Larsen & Toubro Ltd/M/s Havells India Ltd MCB (Brand-Max3, EURO-II), MCCB (Brand- HIM & HIX)/M/s Panasonic Life Solutions India Pvt Ltd (Switch Gear: Panasonic)
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead wire 4mm dia size by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate No 3 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated including testing complete.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected.
BIMAL BHATTRAI
JALAPAHAR HARDWARE
HIRA SINGH
RAI CONSTRUCTION
M/S TSHERING BHUTIA
Darjeeling Enterprises
Damdoo Bhutia
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .