Loading…
Loading…
Tender Value
₹32.8 L
EMD Value
₹65,668
Closing Date
2 May 2026, 3:00 pmClosed
Executive Engineer North Roads PWD
Opp. Khalsa College, Mall Road, Delhi -110054
A/R and M/O Roads under North Roads Division, PWD, Delhi during 2026-27 (SH- Replacement of damaged polycarbonate sheet and painting work of FOB at Azadpur under Sub Division NR-12
2026_PWD_290422_1
04/EE/NR/PWD/26-27/Delhi
Open Tender
Civil Works - Roads
Percentage
30 days
North Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹65,668
29 Apr 2026
25 Apr 2026
2 May 2026
25 Apr 2026
2 May 2026
25 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 5,614 | sqm | 25.15 | ₹1,41,192.1 |
| 2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work | 5,614 | sqm | 155.9 | ₹8,75,222.6 |
| 3 | Providing and fixing multi-walled transparent / opaque 10mm thick polycarbonate sheet of required colour blue, brown or green etc. UV co-extruded and having UV coating on one side multi walled sheet of weight not less than 1.60 to 2.05kg/sqm as approved by Engineer-in-charge. The light transmission from transparent or translucent or opaque polycarbonate sheet varies from 30 to 80% and shall be decided by engineer in charge as per requirement. The panel shall satisfy the Dart drop impact test for value above 15 and upto 60 Joules and confirm either flame retardancy of class UL-94HB/94V-0 category as per IS14434:2023 or category V0 & HB as per ASTM D635-18 or BSID0 classification as per EN13501 for fire salety. The yellowness index tested as per ASTM E313 (D1925) shall be less than or equal to 2 or it shall be 1 unit as per ASTM D 2244 at the time of installation and shall be less than or equal to 10 as per ASTM E313 (D 1925) or 6 units as per ASTM D 2244 on a sample after 5000 Hours of exposure of UV / sun light. The multi walled poly carbonate sheet shall be fixed on tubular steel structure with aluminium Alcox section of'size 60x18x2 mm (anodized 25 micron thick) and weight not less than 0.462 kg/metre. Weather proof Neoprene / EPDM rubber gasket shall be fixed on both side of joints to make the whole structure water tight as per approved design/drawings. The aluminium section shall be fixed on Joints at both sides (top & bottom) of polycarbonate sheet to hold the sheets rigidly together. The weather proof neoprene gasket and aluminium profile shall be fixed and sealed with silicon sealant to make the Joints fully water proof. The open overhead ends of polycarbonate sheet to be sealed with anodised aluminium U Profile/ channel of size 10x10x1.5 mm thick of weight not less than 0.2kg/m. The polycarbonate sheet and aluminium profile shall be fixed to MS Framed Structure with self-taping and self-drilling 55mm long steel screws to be fixed @ 300mm centre to centre. The rate shall be inclusive of cost of all material involved such as polycarbonate sheet, aluminium profile and aluminium channel, EPDM gasket, Self-taping screws, nut bolts, Silicon sealant or axy other material requircd for fixing the sheet but excluding the cost of steel structure which shall be paid separately including hoisting the sheets and fixing in position in required scaffolding shape. The rate shalI also include the cost of all T&P scaffolding and safery precautions required during execution of the work. The entire work shall be executed as per required design/drawings and direction of Engineer-in-charge, all complete.
10 mm thick and U-value not more than 2.50 W/m2K | 1,795 | sqn | 978 | ₹17,55,510 |
| 4Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work | |||||
| 4.01 | 15 mm dia nominal bore | 100 | metre | 322.15 | ₹32,215 |
| 4.02 | 25 mm dia nominal bore | 100 | metre | 467.75 | ₹46,775 |
| 4.03 | 40 mm dia nominal bore | 100 | metre | 617.05 | ₹61,705 |
| 4.04 | 50 mm dia nominal bore | 200 | metre | 762.15 | ₹1,52,430 |
| 4.05 | 80 mm dia nominal bore | 300 | metre | 1,041.7 | ₹3,12,510 |
| 5 | Less: GST Correction factor (1 - 0.973 = 0.027) on DSR items | 1 | L.S | 91,194 | ₹91,194 |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.10 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_385460.xls
BOQ • 0.34 MB
NITReplacementofdamagedpolycarbonatesheet.pdf
Tender Documents • 1.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .