Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,500
Closing Date
15 Jun 2023, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO1 (Works)
HQ 6 Sector Assam Rifles, Kashiram Basti
Repair and maint of floor, Ceiling, Roof and Periodical services to Pre Fabricated Shelter (Bldg No. DT/T/PFS/47 and T/PFTS/01) of HQ 6 Sector Assam Rifles at Kashiram Basti, Dimapur
2023_ARMHA_757084_1
6 Sect AR/Engr/MW/2023-24/07
Open Tender
Civil Works
Item Rate
30 days
Kashiram Basti
As Per Tender Documents
2 documents required · 2 mandatory
₹500
SO1 (Works)
₹10,500
1 Aug 2023
9 Jun 2023
16 Jun 2023
9 Jun 2023
15 Jun 2023
9 Jun 2023
9 Jun 2023 - 13 Jun 2023
SCHEDULE ‘A’ PART - I (Repair of Building)
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
Providing and laying vitrified floor tiles in size 600 x 600mm (thickness to be specified by the manufacturer) of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Dismantling cement asbestos sheets or other hard board in ceiling , including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and laying false ceiling tiles of approved texture in the grid including, required cutting /making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge of GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive)
Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface.
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specificationon on Old work (one or more coats)
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge, 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete in Ridges plain (500 - 600mm).
SCHEDULE ‘A’ PART - I (Internal Electrifications) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) .
Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply and fixing brass batten/ angle holder including connection etc. as required.
Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp.
Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp.
Supplying and fixing 3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin 15/16 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and drawing 2x2.5 Sqm mm of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
Supplying and drawing 2x 4 Sqm mm of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required (for AC).
Supply and fixing of LED Square ceiling ligh tof 20 Watt (Size - 300x300mm) of ceiling fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
M/S. MM Enterprises
GAUTAM ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .