Tender Value
₹29.9 L
EMD Value
₹60,000
Closing Date
12 Oct 2020, 3:00 pmClosed
Project Manager
PROJECT MANAGER, UNIT-13, MIG-67, INDIRA NAGAR (NEAR POWER HOUSE), BANDA
CONSTRUCTION OF AUDITORIUM IN DIET CAMPUS AT DISTRICT- BANDA
2020_UPPRC_518241_1
14/PCL/PM/UNIT-13/BANDA
Limited
Civil Works
Item Rate
180 days
Banda
CONSTRUCTION OF AUDITORIUM IN DIET CAMPUS AT DISTRICT- BANDA
2 documents required · 2 mandatory
₹2,950
Project Manager, Unit-13
₹60,000
19 Oct 2020
6 Oct 2020
12 Oct 2020
6 Oct 2020
12 Oct 2020
6 Oct 2020
Amount
MAIN BUILDING / AUDITORIUM
Cleaning of site
Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
Filling of Cartage earth.
Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.
As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete)
As in item 6 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
As in item 6 above but in R.C.C. Raft foundation & footing .(Using 1:1.5:3 Mix concrete)
As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-20 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia single bulb piles
First Class brick work in 1:6 cement and coarse sand of 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand)
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand)
Same as in item no. 14 but in1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
15 mm thick plaster with cement mortar in proportion of 1:3 cement & coarse sand in plinth.
12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.
Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work.
Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work.
25 mm thick Kota stone slab flooring over 20 mm thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing & polishing complete.
25mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick.
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing & fixing of hold fast for chaukhatsof doors and windows.
Providing & fixing of door / windows grill.
Supply & fixing of Z-section windows
Angle Iron door chaukhat 40*40*5
Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works)
Same as above item but in New wood surface
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Fixing of door, window, ventilator chaukhat Door
Fixing of door, window, ventilator chaukhat Window
Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 200 mm x 10mm
Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and laying "brick coba" 120 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Making drain along with the apron.
Making grooves 10 to 12 mm wide x 8mm deep in plaster of the walls or in ceiling vertically or horizontally as required.
20 mm thick pre-cast cement concrete tiles with aggregate of size upto 6 mm laid in floor, trades of steps and landing on 20 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) with neat cement slurry with pigment to match the shade of the tiles.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing on wall face unplasticised Rigid 110mm dia PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382 a) 110mm a) 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) 110mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand).
Providing & laying Inter locking pathway
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash.
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash.
Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and piano type switches & socket etc., complete in all respects as directed, including matching color wash.
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
2 x 10 sq. mm. With 1 x 6 sq.mm. Earth wire In 25 mm dia conduit.
2 x 16 sq. mm. With 1 x 10 sq.mm. Earth wire In 32 mm dia conduit.
Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects. 20 mm dia. conduit
Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects. 25 mm dia. conduit
Supply & fixing of Recess/pendent/surface round 12 to 15 Watt LED Down lighter having powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.
Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.
Add for fixing of tube fitting as pendent with two number 19 mm dia. 16 gauge rigid steel conduit double check nuts : spring loaded flanges or M.S. hook fabricated from 25mm x 3mm flat iron duly grouted in the ceiling upto 3.5 height of ceiling upto 3.5 height of ceiling, including painting with synthetic enamel paint. alongwith supply of all materials, labour, T & P etc. required for proper completion of work.
Add extra to above item for 15 cm or part thereof for room height above 3.5 m. ( S. NO. 1144X4)
Supply and fixing of LED street light fitting havingdie cost aluminium body and diffuser with driver set suitable 75 to 90 Watt Confirming to IP 66 and above protection complete in all respects. On wall.
Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. 600x480x200 mm. size
Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. 600x480x200 mm. size
Supply and fixing of surface/ flush mounting 4 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge. 4 way TPN
Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 5 - 32 amps.Cat. A
Supply and fixing of single pole MCB blanking plate CAT B
Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge. 40 Amp 2 Pole
Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp 2 Pole
Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work.
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required.
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system
Supply and erection of factory fabricated and wired metal clad dust and vermin proof mounting panel TPN switch board complete with HRC tube heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respect. 100 AMP TPN Outgoing
S/F of door chime on Polished M.D.F.E.G. board including making connections etc. complete in all respects.
S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules.
S/F of shock treatment chart ( prescribed under I.E.rules ) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P etc for proper completion of work.
Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality.
Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make : USHA Cat No. TURBO JET DLX 300mm sweep.
Supply & fixing of ISI marked portable fire extinguishers, complete with initiall charge and wall bracket along with supply of all materials and labour for proper completion of work. CO2 type. 4.5 Lt.capacity
S/F of Fire extinguishers, abc Type 6 kg. Capacity ( ISI Marked IS: 15683 & TAC approved ) Complete with initial charge and wall Bracket, along with supply of all mwtrials and labour for proper completion of work.
GDST extra as applicable
M/s Raj Kishore Gupta
DISHA ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .