Loading…
Loading…
Tender Value
₹7.5 Cr
EMD Value
₹7.5 L
Closing Date
31 Jul 2026, 11:00 amClosed
Civil work, Landscaping Works, Security work, Electrical work and Fountain Work etc
NSL/CEO/UPSC/NIT/2026/921
NSL/CEO/UPSC/NIT/2026/921
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹11,800
₹7.5 L
31 Jul 2026
16 Jul 2026
31 Jul 2026
31 Jul 2026
Grand Total 7,51,12,913.72
unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall
be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
1.7 15.6 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. kg 2,500.00 9.05 22,625.00
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres
15.23.1 For thickness of tiles 10 mm to 25 mm sqm 120.00 73.40 8,808.00
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead.
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50
Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of
1.11 15.51 useful materials near the site and disposal of unserviceable materials within 50 metres lead including each 10.00 958.75 9,587.50
refilling the excavated gap.
Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful
1.12 19.24 materials near the site and disposal of unserviceable materials within 50 m lead as per direction of
Engineer-incharge:
a 19.24.2 Rectangular manhole 120x90 cm and 90 cm deep each 5.00 4,475.50 22,377.50
b 19.24.4 Circular manhole 122 cm diameter and 1.68 m deep each 5.00 6,472.40 32,362.00
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of
rubbish to the dumping ground within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including
1.14 15.57 disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed sqm 450.00 56.35 25,357.50
by Engineerin- charge.
Digitally signed by AMIT
Removal and stacking of all electrical fittings including low side works of all kinds including lights, fans, wire,
1.15 NDSR distribution board etc. complete in all respects. The item to include disconnection of live circuits from the sqm 90.00 500.00 45,000.00
tap-off as per site conditions.
Removal and stacking of external lighting of all kinds including bollard light, pole light, boundary wall light
etc. complete in all respects.
based on Dismantling of cobble stone flooring complete in all respects including stacking of serviceable material
15.25 and disposal of unserviceable material within 50 metres lead.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish
etc., disposal of unserviceable material to the dumping ground, for which payment shall be made
separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc.,
1.19 NDSR disposal of unserviceable material to the dumping ground, for which payment shall be made separately metre 849.97 39.35 33,446.14
and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Removal and stacking of bollards (stone/ metal/ concrete etc) complete in all respects including stacking
of serviceable material and disposal of unserviceable material.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical
1.21 15.6 means, including loading, transporting, unloading to approved municipal dumping ground or as cum 1,000.00 263.95 2,63,950.00
approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Taking out of dismantled Grills/Wires/Lights etc. as is where is basis and deposit of salvage to the client as
per direction of the Engineer In charge.
Total (Dismantling) 20,69,019.79
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated
soil as directed, within a lead of 50 m.
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the
2.2 2.10 excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including
consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as
directed, within a lead of 50 m :
2.10.1 All kinds of soil
a 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia rmt 150.00 352.15 52,822.50
b 2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm rmt 80.00 549.75 43,980.00
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not
2.3 2.25 exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 cum 255.00 196.00 49,980.00
and for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep
and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Digitally signed by AMIT
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to
2.6 2.31 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m sqm 1,905.00 17.60 33,528.00
outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and
branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
2.33.1 Beyond 30 cm girth upto and including 60 cm girth each 5.00 532.35 2,661.75
2.9 2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 18.00 234.75 4,225.50
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the
cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including
2.35.3 drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match
the existing floor:
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration sqm 88.00 310.05 27,284.40
Total (Earth works ) 4,35,923.40
3 Concrete works
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per
3.1 4.6 approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the
cost of required centering, shuttering complete.
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20
mm nominal size derived from natural sources).
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III)
derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural
3.2 4.17 sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated sqm 92.00 749.30 68,935.60
and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement
concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland
Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the
cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following
grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix
shall be payable separately. In case the cement content in design mix is more than 110% of the minimum
specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost
of extra cement.
a 4.20.1 All works upto plinth level :
4.20.1.2 Concrete of M15 grade with minimum cement content of 240 kg /cum cum 23.00 8,986.15 2,06,681.45
b 4.20.2 All works above plinth and upto floor V level
4.20.2.2 Concrete of M15 grade with minimum cement content of 240 kg /cum cum 128.00 9,341.80 11,95,750.40
Digitally signed by AMIT
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions
as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without
impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but
excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
charge, for the following grades of concrete.:
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable
separately. In case the cement content in design mix is more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
a 5.33.1 All works upto plinth level
5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum cum 56.70 9,655.70 5,47,478.19
b 5.33.2 All works above plinth level upto floor V level
i 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 55.00 9,860.40 5,42,322.00
ii 5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum cum 22.00 10,011.35 2,20,249.70
3.5 5.9 Centering and shuttering including strutting, propping etc. and removal of form for
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 210.00 395.15 82,981.50
b 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 445.00 736.40 3,27,698.00
c 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 234.00 961.30 2,24,944.20
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 7,371.00 107.85 7,94,962.35
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 10,010.00 107.85 10,79,578.50
Total Concrete works 1,14,00,376.89
4 Masonry, plaster and wet works
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure
above plinth level up to floor V level in all shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 82.00 9,344.35 7,66,236.70
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 30.00 1,123.80 33,714.00
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick
4.4 13.1 12 mm cement plaster of mix :
4.5 13.4 12 mm cement plaster of mix :
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with
a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white
4.6 8.14 cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone
shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for
8.14.1 Red sand stone - exposed face fine dressed with rough backing.
Digitally signed by AMIT
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the
4.7 8.15 backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), kg 20.00 714.40 14,288.00
including making the necessary chases in stone and holes in walls wherever required.
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall
lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.
Providing and fixing dry cladding upto 10 metre height with 30 mm thick gang saw cut stone with machine
cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the
4.9 8.20 help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural
drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc.
shall be paid for separately).
8.20.1 Red sand stone - 30 mm thick gang saw cut stone sqm 925.00 2,902.65 26,84,951.25
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine
cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as
per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to
the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame
and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone
aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and
4.10 8.21 shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary kg 22,375.00 269.95 60,40,131.25
holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel
work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two
or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-
charge for approval before execution). The frame work shall be fixed in true horizontal & vertical
lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size,
adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gram), for dry stone
cladding fixed on frame work at suitable location, including making necessary recesses in stone slab,
drilling required holes etc complete as per direction of the Engineer-in-charge.
Providing 50x50x50 mm 2nd class teak wood plugs including cutting brick work and fixing in cement
mortar 1:3 (1 cement : 3 fine sand) and making good the walls etc.
Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised
M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine
cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,
4.14 8.2 approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble
4.15 8.2.2 Granite stone slab of colour black, Cherry/Ruby red
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing
to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Digitally signed by AMIT
a 8.3.1 Marble work metre 26.00 298.60 7,763.60
b 8.3.2 Granite work metre 35.00 510.95 17,883.25
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade sqm 282.00 3,617.55 10,20,149.10
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-
4.18 11.23 charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with grey cement slurry, including rubbing and polishing complete with :
4.19 11.24 Extra for pre finished nosing to treads of steps of marble stone. metre 20.00 719.90 14,398.00
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :
4.20 11.29 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of
pigment to match the shade of stone.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks,
lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table
vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of
4.21 16.91 sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding
layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver
blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of
Engineer-in-Charge.
16.91.1 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. sqm 20.00 1,045.65 20,913.00
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in
all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey
4.22 11.41A cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc.
The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the
notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the
tiles gently and easily.
11.41A.2 Glazed vitrified floor tiles polished finish of size
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic
4.23 NDSR coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting
and finishing complete as per direction of Engineer-in-charge.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm
having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours
and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm
thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the
joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone
slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed
with cement slurry and pointing with white cement slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-
11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 100.00 3,186.70 3,18,670.00
4.26 Extra for fixing granite in treads of steps, risers, ramp etc. sqm 20.00 120.00 2,400.00
Digitally signed by AMIT
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in
4.27 16.92 floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide sqm 155.00 2,189.15 3,39,318.25
filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
Total (Masonry, plaster and wet works) 1,80,01,326.25
5 Doors, windows, partition and roofing
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC
multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having
minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles
conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and
Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade
fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade
sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and
necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and
fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware
and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be
filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per
approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel
reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance
coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:-
Structural design proof checked from a Government Engineering Institute, to be provided by the
manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure
height more than 20m for all wind speeds
Casement window double panels with French (False) Mullion with S.S. 304 friction hinges as per size and
weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.
Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm &
9.147.E3.1 above) & French (False) mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). sqm 10.00 11,715.95 1,17,159.50
5.2 9.147.C2 Fixed window / ventilator with mullion / transom.
Using R2 series with frame (39 mm & above ) x (39 mm & above) & mullion (39 mm & above) x (60 mm &
above). (Height upto 1.2 metre)
Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point
5.3 9.147.F2 locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.
Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm &
9.147.F2.1 above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 2.5 metre). sqm 19.00 11,903.75 2,26,171.25
Designing, providing, installing and fixing factory finished custom designed (profile as per architect)
powered coated MS tubular structure including all required nessesary hardware and fittings complete as
per design confirming to relevant latest IS codes. The wind load shall be as per provisions of IS 875 (part -III).
the stell strucure shall be designed as per IS: 801 using commercially available software such as Frame
CAD Pro-11.7/ STAAD PRO-8i/ArchitekV2.5.16/ Revit architecture-2011 or equivalent.the MS Tubular
5.4 rectangular and square (of minimum sizes 72x72x3.2MM, 100x50x3MM 80x40x2.5MM, Base plate sqm 231.00 6,053.40 13,98,335.40
250x250x12MM, Column Top plate 90x90x6mm ) sections with the systems of purlins and portals. The item to
include vertical support MS columns required to make the roof truss erect independently in seismic and
wind load conditions as per the latest IS Codes. The item to include making of necessary provisioning for
overhead water tank as per design and specifications shared be the Architect. The plan area of the roof
shall be measured for payment.
Digitally signed by AMIT
Designing, providing, installation and fixing of walls made out of GI Steel Sheet 0.5MM - EPS - Steel
composite sand coated insulated sandwich panels with toughned groove locking systems complete as
per directions of engineer-in-charge/ Architect.The E.P.S. used as the core will be self extinguishing type.
The overall thickness of the wall shall not be less than 72mm. The item to include all nessesary hardware,
fittings and fixtures required. The item to also include making nessesary cut-outs for doors, windows,
ventilators, etc with complete sub-frame and finishing.
Desiging, Providing, installation and fixing of roof Puff panels made up of 50+80mm thick composite PUF
panels sandwiched between PPGI 0.5mm Sheets including all required necessary hardware, fittings and
fixture. The outer skin of trapezoidal PPGI sheet with depth of crest -28-30mm. Pitch 195-200mm trapezoidal
sheet & inner skin micro riving PPGI sheet & minimum 50mm thick layer of rigid CFC free polyurethane
foam of density of 40±2 Kg/m3 as insulation. The color of PPGI sheetto be as per approval of engineer-in-
charge/ Architect. The gaps between puff panels to be sealed as per manufacturers specifications to
make it air and water tight to prevent the entry of dust and water seepage in case of extreme weather
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3
5.7 12.7 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes
12.7.1 0.80 mm thick with zinc coating not less than 275 gm/m² metre 30.00 1,029.65 30,889.50
Total (Doors, windows, partition and roofing) 44,70,320.65
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27
mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm
of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate
G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling
section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,
at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall
screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with
the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish
of tapered and square edges of the board with recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of
primer suitable for board, all as per manufacturer’s specification and also including the cost of making
openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all
complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of
painting with :
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board sqm 18.00 1,529.10 27,523.80
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and
fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of
the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main
C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with the help of soffit cleat
37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at
1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of
Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm
centers with the help of suspension brackets. Wherever the main C carrier and spring T have to join, C
carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side
inclusive), fixing with clip in tiles into spring T with :
Digitally signed by AMIT
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25
mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro
statically polyester powder coated of thickness 60 microns (minimum), including factory painted after
Total Ceiling 1,87,486.20 0.00
7 Fountain works
Supplying, Installation Testing Commissioning of Fixing of 40 mm dia Bubbler Jet Nozzles in SS 304 Gr to
produce water effect etc. complete as required.
Supply, installation, testing and commissioning of cascade (waterfall) fountain nozzel assembly of size 900-
1200mm (approx) manufactured from 304 stainless steel, designed to produce a uniform, laminar sheet of
water over the entire width of the nozzel without splash or flow sepration. The cascade nozzel shall
1. fabricated SS304 body of minimum 2.0mm thick sheet with TIG welded construction.
2. internal flow straightener and diffiser chamber to ensure uniform water distribution.
7.2 3. Removable stainless steel flow equalizer plate for maintainance. each 2.00 28,000.00 56,000.00
4. Bottom flanged/ threaded inlet suitable for 40-50mm BSP connection.
5. internal mounting bracket with provision for three-axis alignment.
6. SS304 anchor fastenes, gaskets and hardware.
The cost shall included complete fixing on RCC/ Stone structure, connection to delivery pipeline,
alignment and levelling, all SS fittings, unions, nipples, reducers etc complete as directed by engineer-in-
Supplying, Installation, Testing and Commissioning of fixing of Suction Screen stainer made of ABS to be
fitted in suction to protect the pump from enrty of external materials etc. complete as required.
Supplying, Installation, Testing and Commissioning of 100 mm Dia Debris Collection Strainer in Stainless steel
304 gr etc. complete as reqd.
Supplying, Installation, Testing and Commissioning of 400 mm Dia wide SS Overflow Skimmer in Stainless
7.5 20.14 steel 304 gr with front openable fitted debris trapping mesh with outlet size of 65mm Dia for fixing in wall each 4.00 10,420.00 41,680.00
etc. Complete as reqd.
Supplying, Installation, Testing and Commissioning of 300x300 mm Dia Main Drain in SS 304 Gr with
perforations to disallow foreign material with top openable for maintenance etc. complete as required.
Supplying, Installation, Testing and Commissioning of three phase open well ISI Marked submersible
pumpset of 1.5H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for
operations on dynamic variable frequency / speed having IP 68 Protection including providing required
no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS
sheet as required. and making of flexible IP68 cable connections etc. complete of suitable head and
discharge etc. complete as required.
Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal gate valve
(Screwed type) on the existing pipeline, including testing & Commissioning etc. complete as required..
Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal Horizontal Non
7.9 20.21 Return valve ( screwed type ) on the existing pipeline, including testing & Commissioning etc. complete as
Digitally signed by AMIT
Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED
7.10 20.22 spot light 6 x 3W with IP 68 protection, SS/ aluminum dia casting body with power coated paint, soft rubber each 8.00 13,659.00 1,09,272.00
gasket along with 2 years free replacement guaranty etc. complete as required..
Supplying, Installation, Testing and Commissioning of water proof (IP 68) power supply unit of not less than
200W i/c connection along with 2 years free replacement guaranty etc. complete as required.
Supplying, Installation, Testing and Commissioning of RGB controller with remote Kit wattage not less than
200 watt i/c connection along with 2 years free replacement guaranty etc. complete as required.
Supplying, Installation, Testing and Commissioning of Signal Amplifier of RGB signal as require i/c
connection along with 2 years free replacement guaranty etc. complete as required.
Supplying, Installation, Testing and Commissioning of fixing of Power Supply/SMPS for suitable to run LED
Lights, Body-Metal input Power-220 V AC/ Output Power-12 V DC etc. complete as required.
Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in
7.15 20.28 existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with
suitable cable tags of following sizes etc. complete as required.
20.28.2 3 Core 2.5 Sq mm Flat Cable metre 80.00 124.00 9,920.00
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m
7.16 18.8 spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of
cutting chases and making good the the same including testing of joints complete as per direction of
engineer in charge.
a Concealed work including cutting chases and making good the walls etc.
b 18.8.2 20 mm nominal outer dia pipes. Metre 50.00 537.60 26,880.00
c 18.8.3 25 mm nominal dia Pipes Metre 75.00 627.25 47,043.75
18.8.4 32 mm nominal dia Pipes Metre 100.00 739.00 73,900.00
Total (Fountain works) 7,87,377.75
8 Finishing & miscellaneous works
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic
8.2 13.83 Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and colour.
Preparation of complete set of civil and interior finishing drawings including details. A qualified professional
for the purpose shall be appointed after due appproval from Engineer In Charge.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile
Organic Compound ) content.
13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre sqm 231.00 73.95 17,082.45
8.5 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer
applied @ 0.90 litre/10 sqm)
Digitally signed by AMIT
8.6 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer
applied @ 2.20kg/10 sqm
8.7 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
13.61.1 Two or more coats on new work sqm 1,500.00 155.90 2,33,850.00
Supply & Installation of tensile fabric canopy. The entire structural frame work should be designed as per
the current codes and fixed over granite platform / in ground including digging concrete base
preparation for foundation block base plate and erection with repair and resurfacing to match existing
finish. The fabric to be Ferrari/ low & Bonar or equivalent Fabric is resistance to U.V. rays and color
degradation, U.V. resistance: 7 to 8/8 treated with Teflon for anti staining, oil repellency and rot proof with
8.8 NDSR a Water Repellent- 30 cm water column and will not support mildew growth The structure should be sqm 110.00 12,910.00 14,20,100.00
complete in all respect including fittings and accessories. Provision of water drainage via. channel and
pipe at the end of the slope required.
Foundation preparation for the tubular section , PCC block exceeding 100mm on all side more than
tubular section foot print, structure should withstand wind load or structurally sound etc. complete subject
to detail engineering on site and submit shop drawings/ stadd calculation before starting the work.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in
cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3
(1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1
cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel
in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal
diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in
19.9.1 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the
external surface shall be paid for separately) :
a 19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 10.00 12,725.00 1,27,250.00
b 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 10.00 12,600.00 1,26,000.00
Steel work welded in built up sections/ framed work, including cutting,
8.10 10.25 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works kg 25,000.00 172.60 43,15,000.00
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate,
moorum screening, red bajri and labour required.
16.13.1 bituminous portion cum 18.00 5,032.25 90,580.50
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre
openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall
with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced
8.12 16.53 barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. metre 255.00 375.80 95,829.00
barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed
tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm
thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Digitally signed by AMIT
Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan
shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material
consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm
thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer
(Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather
silicone sealant, backer rods etc. The ACP shall be fixing over existing MS base framwork complete as per
approved design and instruction of engineer-in-charge.
Total Finishing & miscellaneous works 53,86,684.45 22,11,654.50
Providing and fixing of text/signages made out of brushed/matt finish 1.2mm thick stainless steel-304 grade
electroplated in shade as per approval of the client/ engineer-in-charge. The signage fixed on wall shall
be made in two parts - one to be directly fixed on wall using nessecery fastners and the top part shall be
9.1 NDSR fixed over it using matching shade allen key bolts. The signage shall be made backlit using 5mm thick Sq. inch 855.00 985.00 8,42,175.00
acrylic sheet backing and concealed lights. The overall height of the logo shall be upto 700mm and
thickness upto 125mm as per design and approved shop drawing. The overall lenght of the the text/
signage shall be measure for payment.
Providing and fixing of text/signages made out of brushed/matt finish1.2mm thick stainless steel-304 grade
electroplated in shade as per approval of the client/ engineer-in-charge. The signage fixed on wall shall
be made in two parts - one to be directly fixed on wall using nessecery fastners and the top part shall be
9.2 NDSR fixed over it using matching shade allen key bolts. The signage shall be made backlit using 5mm thick Inch 76.00 1,150.00 87,400.00
acrylic sheet backing and concealed lights. The overall height of the logo shall be upto 1200mm and
thickness upto 125mm as per design and approved shop drawing. The overall lenght of the the text/
signage shall be measure for payment.
Providing and fixing of text/signages made out of brushed/matt finish 1.2mm thick stainless steel-304 grade
electroplated in shade as per approval of the client/ engineer-in-charge. The signage shall be free-
9.3 NDSR standing and fixed on floor using nessecery fastners. The signage shall be hollow but closed from all sides. Inch 121.00 950.00 1,14,950.00
The overall height of the logo shall be upto 900mm and thickness shall be upto 300mm as per design and
approved shop drawing. The overall lenght of the the text/ signage shall be measure for payment.
Providing and fixing of text/signages made out of brushed/matt finish 1.2mm thick stainless steel-304 grade
electroplated in shade as per approval of the client/ engineer-in-charge. The signage fixed on wall shall
be made in two parts - one to be directly fixed on wall using nessecery fastners and the top part shall be
fixed over it using matching shade allen key bolts. The overall height of the logo shall be upto 300mm and
thickness upto 50mm as per design and approved shop drawing. The overall lenght of the the text/
signage shall be measure for payment.
Providing and fixing of logo/ signages made out of brushed/matt finish 1.2mm thick stainless steel-304
grade electroplated in shade as per approval of the client/ engineer-in-charge. The signage fixed on wall
shall be made in two parts - one to be directly fixed on wall using nessecery fastners and the top part shall
be fixed over it using matching shade allen key bolts. The overall thickness of the logo shall be upto
100mm as per design and approved shop drawing. The overall extent (lenght x height) of the the logo/
signage shall be measure for payment.
Total Signages 14,56,975.00 0.00
10 Landscaping works
Digitally signed by AMIT
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials
and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up
the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before
and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete
(earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking of sludge at site including royalty and carriage upto 5 km lead complete (sludge
measured in stacks will be reduced by 8% for payment)
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead
complete (manure measured in stacks will be reduced by 8% for payment) :
a 2.4.1 Screened through sieve of I.S. designation 20 mm cum 700.00 391.35 2,73,945.00
b 2.4.2 Screened through sieve of I.S. designation 16 mm cum 700.00 447.05 3,12,935.00
c 2.4.3 Screened through sieve of I.S. designation 4.75 mm cum 700.00 491.65 3,44,155.00
10.5 2.5 Rough dressing the trenched ground including breaking clods. sqm 4,500.00 2.30 10,350.00
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of
uprooted vegetation.
10.7 2.7 Fine dressing of the ground. sqm 4,500.00 5.60 25,200.00
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-
charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-
Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or
10.10 2.10 more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if
needed (the grass and good earth shall be paid for separately).
2.10.1 In rows 5 cm apart in both directions sqm 3,700.00 26.95 99,715.00
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and
other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water,
uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal
of all rubbish with all leads and lifts.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated
base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge
or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of
10.12 2.13 stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if cum 1,090.00 339.85 3,70,436.50
necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials
declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift
up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge
in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked
10.13 2.14 volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and
surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be
paid for separately)
a 2.14.3 Holes 60 cm dia, and 60 cm deep each 1,600.00 47.85 76,560.00
b 2.14.4 Holes 45 cm dia, and 45 cm deep. each 3,200.00 20.65 66,080.00
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and
leveling (cost of supplying earth and sludge or manure and mixing excluded).
Digitally signed by AMIT
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not
10.15 2.28 exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and cum 100.00 696.20 69,620.00
lift upto 1.5 m complete as per direction of Officer-in-charge.
Providing & laying of Selection no. 1 Doob grass turf with earth 50mm to 60mm thickness of existing ground
prepared with proper level and ramming with required tools wooden and than rolling the surface with
light roller make the surface smoothen and light watering the same and maintenance for 30 days or more
till the grass establish properly, as per direction of the officer-in-charge.
Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of
unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water).
b 2.57.3 Hedge Plant/ Ground Cover Plants /Seasonal Plants each 1,600.00 3.15 5,040.00
Providing and stacking Duranta Golden, having ht. 15 cm to 20 cm bushy shape with fresh and healthy
leaves in 15 cm size of Earthen Pot / Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bag of size 15 cm as per direction of
the officer-in-charge.
Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen,
Variegated, Glabra Formosa, Peruvian Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgence)
plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pot / Plastic pot as per direction
of the officer-incharge.
Providing and stacking of Tecoma argentea height 120-135 cm. in poly bag size 25 cm as per direction of
the officer-in-charge.
Providing and stacking Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15
cm size of Earthen Pot / Plastic Pot and as per direction of the officer-in-charge.
Providing, stacking and Displaying Cycus revoluta specimen plant, having 45 to 50 fresh and healthy,
10.23 5.15 leaves having 30 cm to 35 cm circumfrance of base stem well developed in 40 cm challi and as per each 80.00 1,678.00 1,34,240.00
direction of the officer-in-charge.
Providing, stacking and Displaying Bird of paradise well developed with fresh & healthy 90 cm to 120 cm ht
in 30 cm Earthen Pot/ Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Bottle palm ht. 270-300 cm bottom girth 40- 50 cm well developed in big HDPE
bag as per direction of the officer-incharge.
Providing & fixing White River (Stone) Pebbles size of 2" to 2.5" dia (5 cm to 6.25 cm), in natural colour at site
of work including loading, unloading, carriage etc. and as per direction of officer-in-charge.
Removal of garden waste by TATA 407 or equivalent including loading/ unloading and carriage upto 1 km
lead,complete disposal upto designated place as per direction of officer-in-charge
Total Landscaping works 75,70,416.86 0.00
11 Security infrastructure
11.1 Automatic Parking Hydraulic Boom Barrier
Digitally signed by AMIT
Boom Length in 3 mtr. LED Type Boom, LED Connectivity
Options., Automatic Barrier Feature:
Barriers Hydraulic barrier (Right /Left Version)with boom
Opening/ Closing Time – 4-5 Sec. Fully.
Automatic with use cycles 100% with push button, Four J
hooks, Foundation plate. Round Boom. Push Button.
BARRIER MODEL 630 STD
Power supply (Vac / Hz) 230 {+6%/ -10%} / 50
Absorbed power (W) 220
Absorbed current (A) 1
Type of oil FAAC HP OIL
Oil quantity (Lt) ~ 1.8 , Barrier weight – 73 Kg
Winding heat protection (°C) 120
Anti-crushing system standard by-pass valves
Type of slow-down Electronic
Operating ambient temperature (°C) -20 / +55
Hood protective treatment Catachresis AISI 316 L
Protection class IP 44
Body Dimensions 390,290, 200,94
Photocell (Safety Beam Sensor)
SITC of above items nos. 4.00 3,34,651.50 13,38,606.00
Supply,s installation, testing and commissioning of UVSS (under-vehical scanning system) to enable
inspection of any vehicle’s underside through a static composite image of the vehicle. It should produce
multiple angular view of high resolution 3D COLOR images of the complete under body of any vehicle
11.2 passing over it using dual Area-scan camera based technology and should be capable of handling nos 1.00 85,50,915.00 85,50,915.00
vehicles moving at different speeds ranging from Zero (0) to 25 Km/hr, complete as per technical
specifications.The item shall be executed complete in all respects as per the satisfaction of engineer-in-
charge, including all associated civil, electrical and drainage works.
Supplying, installation, testing and commissioning of 9 zone or above Door frame Metal detector for both
ferrous and non ferrous metals of nominal Size : 700 mm (W) x 1950 mm (H) x 500 mm (D) (minimum). To be
equipped with audio visual alarm with 2 line alphanumeric LCD display, height on person bar display
(metal locator) and low battery indicator. Should have a wide range of sennsitivity setting and fine tuning,
adjustable in step to 250 levels, including a 4 level basic setting. The calibration to be adjustable manually
nad automatically by built - in keypad. It should have Intelligent traffic counter for calculating the number
11.3 of people in and out also the alarm number with percentage display. It should confirm to (1)Conform to
relevant electric safety standard (Supported by Test Certificates from NABL {India} or other accredited labs
from the country of origin of the equipment). (2)The magnetic field should be as per ICNIRP Guidelines
(International Commission on Non Ionizing Radiation Protection). The references values for general public
are given in table VII of the ICNIRP Guidelines. (3)Should not be affected by external RF transmission and
EMI. (Supported by Test Certificates from NABL {India} or other accredited labs from the country of origin of
Digitally signed by AMIT
A suitable control panel shall be provided to turn unit on, access and adjust setup and programming. The
control panel shall be used to turn the DFMD on. The unit should be ready to operate within ten seconds.
The manual self-test shall be activated at any time by pressing suitable control menu. The control panel
shall be used to turn the DFMD off, ensuring that all of the information and settings are stored in memory
before shut down. The DFMD Control panel should be tamper proof. All settings should be secured with a
key lock. Further security should be accomplished with a cabinet lock to prevent unauthorized access to
physical cables, connectors & electronics. The detector
shall have a minimum of 9 zones of metal detection. These zones shall operate as individual detectors and
detect the presence of metal in their confined region. Zone display shall be on front panel with human
symbol. The zones shall be arranged in the following methodology: Top Left, Top Center and Top Right.
Middle Left, Middle Center and Middle Right. Bottom Left, Bottom Center and Bottom Right.
The DFMD shall have a 90-270v operation SMPS Power Supply, Should be provided with internal battery
back-up for 12 hours minimum operation in case of power cut. The DFMD shall have a remote control to
operate the control panel without using the buttons on the panel. The Remote shall have similar buttons as
on the control panel to allow similar operation.
The DFMD shall have a provision to interface to a Computer Network using the Ethernet connection. There
shall be a provision to interface multiple DFMD’s on the same network to monitor or control the detectors
through Software.
Supply, installation, testing and commissioning of baggage scanners of size (minimum) 1380mm (L) X
11.4 740mm (W) X1190mm (H) and tunnel opening of 500mm X 300mm (+/- 2%), complete as per the attached nos 2.00 3,83,118.00 7,66,236.00
technical specifications and satisfaction of engineer-in-charge.
Total Security infrastructure 0.00 1,15,78,932.00
12.1 Podium for security (overall dimension - 1200 (L) x 500(W) x 1200mm (H)) nos 1.00 1,50,000.00 1,50,000.00
Providing and placing of podium made out of MS support members and cladded with HPL complete as
per approved design. The overall dimension of the podium shall be 1200 (L) x 500(W) x 1200mm (H)
12.2 Security officer
Main table - 1350 x 600mm x 750mm
Back unit- 2000 x 450 x 750mm
Digitally signed by AMIT
Providing and placing Cabin Table with the following specifications:
Main Table: The main top, along with the legs, are to be constructed from 25mm E-1 grade Particle board,
finished with 2mm PVC edge banding. The Particle board must use E1 grade laminate with zero urea
formaldehyde emissions (≤ 8mg/100g oven dry board-perforated method) to ensure better in-house air
quality, complying with EN 120-1992 standards. All exposed edges of the worktop shall be secured with
2mm thick PVC edge banding. The modesty panel, 18mm thick, should also be made of E-1 grade Particle
board with 2mm PVC edge banding, meeting the same emission standards as the top and legs.
Wire management: It must be completely concealed, featuring an aluminium anodized flipper with soft
closure, a wiring tray, and housing made from 1.2mm MS sheet. The flange structure should have an epoxy
powder coating of 70-80 microns, spray-coloured and baked at 200°C. Vertical wire uptake from the floor
should be facilitated via a flexible cable riser or metal powder pole.
The drawer unit should be a 3-drawer melamine finish pedestal with overall dimensions (internal and
external) of 390-420mm (W) x 430-460mm (D) x 600-620mm (H). Drawers should be constructed from 18mm
thick E1 Grade Particle board with matching edge banding. Each pedestal must be fitted with 5 castors,
with one castor attached to the lowermost drawer for extra stability.
Low Height Back Storage shall be made from 18mm thick E1 grade prelaminated board with a melamine
finish, complete with PVC edge-banding for enhanced durability and a refined look. These storage units
shall be designed with adjustable shelves to accommodate various storage needs, ensuring versatility and
functionality. The storage units can be fitted with either extruded aluminium handles or recess handles,
according to specific requirements and approvals.
Each storage unit shall be equipped with adjustable levellers to ensure stability on uneven surfaces. The
doors shall feature a three-way lock mechanism, allowing all hinged doors to be locked simultaneously for
added security. Additionally, the doors shall be fitted with a hinge-damping mechanism, enabling soft
closing to prevent slamming and reduce wear over time.
The product shall be BIFMA Gold-rated and SCS Global certified for in-house air quality, ensuring
compliance with industry standards. It shall come with a 5-year warranty, reflecting its quality and
durability. All specifications to be completed as per the manufacturer's guidelines, approved samples, and
the direction of the Engineer-in-Charge.
12.3 Inspector
Main table - 1500 x 750 x 750mm
ERU - 900 x 450 x 750mm
Back unit- 2400 x 450 x 750mm
Digitally signed by AMIT
Providing and placing the furniture with the following specifications:
Table: The cabin office table shall feature a main and return top, as well as legs, constructed from 36mm E-
1 grade particle board. The particle board must be finished with 2mm PVC edge banding. For enhanced
indoor air quality, the table will be laminated with E1 grade laminate that exhibits zero urea formaldehyde
emissions, with an emission level not exceeding 8mg/100g of oven-dry board as measured by the
perforated method. This laminate must comply with the EN 120-1992 standard. The exposed edges of the
worktop must be secured with 2mm thick PVC edge banding. Additionally, an 18mm thick modesty panel,
also made of E-1 grade particle board, will be finished in the same manner with 2mm PVC edge banding
and E1 grade laminate to ensure consistency and compliance with indoor air quality standards.
Wire Management: The table will include a fully concealed wire management system. This system features
an aluminum anodized flipper with a soft closure mechanism, a wiring tray, and housing made from
1.2mm MS sheet. The flange structure will be epoxy powder-coated with a spray color, applied at a
thickness of 70-80 microns and baked at 200°C. Vertical wire routing from the floor will be facilitated via a set 1.00 1,17,110.00 1,17,110.00
flexible cable riser or metal powder pole as per the design approval.
Drawer Unit: The accompanying drawer unit will consist of a pedestal with three drawers, each featuring a
melamine finish. The overall dimensions of the pedestal will range between 390-420mm in width, 430-
460mm in depth, and 600-620mm in height. Each drawer will be constructed from 18mm thick E1 grade
particle board, with matching edge banding. The pedestal will be equipped with five castors, including
one additional castor on the lower-most drawer to enhance stability.
Materials and Certification: E-1 Grade laminate used to ensure no urea formaldehyde emission, with
phenol base formaldehyde emission not exceeding 8mg/100g oven-dry board (perforated method),
complying with EN 120-1892 standards. The product is BIFMA Gold-rated and SCS Global certified for in-
house air quality, ensuring compliance with industry standards. It shall have a 5-year warranty, reflecting its
quality and durability. All specifications are completed as per the manufacturer's guidelines, approved
samples, and the direction of the Engineer-in-Charge.
12.4 Desk for facial scanning - 900 x 600 x 750mm nos 2.00 45,600.00 91,200.00
Supplying, and placing in position of Free standing table as per Image/drawing. The table top are made
up of 25mm thick pre-laminated particle board with 2mm thk pvc edge banding . The Table supported
with 18mm thk Prelam Particle board side panel & Modesty panel. The working edges shall be provided
with machine pressed 2mm thick PVC edging using special hot melt glue at hot temperature. Provision of
one fixed Pedestal storage unit (combination of two drawers and one filing drawer) . Pedstal Unit made of
18mm thk prelaminated particle board with 2mm thk pvc edge banding. The product should be from
manufacturer(OEM) which have BIFMA COMPLIENT Certification, INDIAN DESIGN MARK Certification,
GREEN PRO Certification, AIOTA Certification, BIFMA LEVEL-1 Certification, GRIHA Certification. The product
should be as per above given specification under the guidance of project architect & Engineer in charge.
Supplying and placing in position of high back 360° degree revolving chair all over size is: 640mm (l) x
480mm (d) x 1240mm (h) as per image. The chair made of full mesh in black colour .it will comes in matte
finish in contemporary style. Arms: arNDSRest is having two adjustment heights (up & down) .use of ply: 12
mm thick hot pressed bwr plywood (is grade - 303 for seat).seat: 40 ± 2 mm thick polyurethane foam with
density 32 (±3) kg per cu meter for best quality cushioning in seat, back: frame of design shall be curved
made of two pieces injection moulded frame cover with mesh .backrest support adjustable lumbar
support, mechanism: self weighted multi locking mechanism .gas lift 100 mm telescopic haudraulic , base :
650 mm chrome base with smooth castors. The product should be from manufacturer(OEM) which have
BIFMA COMPLIENT Certification, INDIAN DESIGN MARK Certification, GREEN PRO Certification, AIOTA
Certification, BIFMA LEVEL-1 Certification, GRIHA Certification. The product should be as per above given
specification under the guidance of project architect & Engineer in charge.
Digitally signed by AMIT
Supplying and placing in position of medium back 360° degree revolving chair all over size is: 610mm (l) x
470mm (d) x 1040mm (h) as per image. The chair made of full mesh in black colour .it will comes in matte
finish in contemporary style. Arms: arNDSRest is having two adjustment heights (up & down).use of ply: 12
mm thick hot pressed bwr plywood (is grade - 303 for seat).seat: 40 ± 2 mm thick polyurethane foam with
density 32 (±3) kg per cu meter for best quality cushioning in seat , back : frame of design shall be curved
made of two pieces injection moulded frame cover with mesh .backrest support adjustable lumbar
support, mechanism: self weighted multi locking mechanism, gas lift 100 mm telescopic haudraulic base:
650 mm chrome base with smooth castors . The product should be from manufacturer(OEM) which have
BIFMA COMPLIENT Certification, INDIAN DESIGN MARK Certification, GREEN PRO Certification, AIOTA
Certification, BIFMA LEVEL-1 Certification, GRIHA Certification. The product should be as per above given
specification under the guidance of project architect & Engineer in charge.
The supply and installation of a 4-door locker unit equipped with cam locks, designed to meet the
following detailed specifications. The locker unit will have overall dimensions of 380 mm in width, 450 mm
in depth, and a height ranging from 1800 mm to 1850 mm.
Constructed from 100% virgin epoxy powder-coated Cold Reduced Carbon Steel Sheets (CRCA), the
locker unit will conform to IS: 513 CR2 (Cold Reduced Carbon Steel Sheets & Strips, Part 1, 2016). The steel
sheets will be procured from TATA Steel, and test certificates will be available upon request. The materials
will undergo a rigorous seven-stage nano-technology-based pre-treatment process before powder
coating, ensuring high corrosion resistance and durability.
The locker shall have a superior finish, smooth, uniform, and high-quality coating. The unit will employ
modern rigid knock-down construction made from 0.8 mm thick CRCA sheet, providing extra strength and
12.7 durability, with each compartment shelf supporting a uniformly distributed load capacity of up to 35 kg. nos 14.00 27,500.00 3,85,000.00
Designed for ease of transportation, the locker unit will be a 100% knock-down product, facilitating safe
and efficient shipping. Assembly will be completed on-site, simplifying logistics and installation processes.
The locker features a simple yet effective design, offering ample capacity for storing clothes, shoes, sports
gear, mobile phones, bags, office supplies, and cleaning materials. Each door will be equipped with a lift-
up handle and recessed hasp, paired with cam locks for secure storage. Label holders will be included for
easy identification, especially useful when multiple lockers are stacked together.
Each shutter shall have louvers that allow free airflow. The locker unit will be BIFMA Gold rated and SCS
Global certified for indoor air quality, ensuring compliance with high standards of safety and
environmental responsibility. Additionally, it shall come with a five-year warranty to guarantee quality and
Total Furniture 0.00 9,65,306.70
Distribution Board
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution
board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar,
common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on
13.2 2.3 surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for
13.3 2.10 inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Digitally signed by AMIT
Supplying and fixing following amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker
13.4 NDSR suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit
13.5 2.15 breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
Supply & Laying of following sizes Copper conductor armoured PVC insulated PVC sheathed XLPE cable of
grade 1.1 KV in the existing open masonary duct/ surface/ cable tray/ pipe etc complete as reqd.
Supplying and making end termination with brass compression gland and Copper lugs for following
size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.
Providing and fixing of Gel-Chemical Earthing Electrode of G.I. made as pipe in pipe technology(IS:3043 :
1987)duly CPRI Approved as per following specification:
Length - (3000 mm)
DIA (outer) - (80 mm)
DIA (Inner) - (40 mm)
13.8 MR DIA-Terminal Strip Hole - (25 mm) Each 2.00 46,890.00 93,780.00
Space Inside Electrodes - (Filled with Conductive Mixture)
Hot Dip Galvanizing - (70 - 100 Microns)
And earth enhancing compound should be used to treat the soil for lowering the effective ground
impedance 50Kg for each earth pit to make it maintenance free and to minimize the ground voltage
potential rise and pit covered with PVC Cover.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including
connection with brass nut bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including
connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required.
13.11 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. P/Mtr 100.00 1,246.00 1,24,600.00
13.12 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. P/Mtr 550.00 287.00 1,57,850.00
13.13 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. P/Mtr 100.00 84.00 8,400.00
Digitally signed by AMIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium class PVC conduit, with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without
independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in
surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed medium class PVC conduit as required.
c 1.14.3 2X4sq.mm+1X4sq. mm earth wire P/Mtr 600.00 373.00 2,23,800.00
d 1.14.4 2X 6sq.mm+ 1 X6sq. mm earth wire P/Mtr 50.00 482.00 24,100.00
e 1.14.5 2X 10sq.mm + 1X 6 sq. mm earth wire P/Mtr 50.00 621.00 31,050.00
h 1.14.8 4X 4sq.mm+ 2X 4sq. mm earth wire P/Mtr 50.00 587.00 29,350.00
i 1.14.9 4X6sq. mm + 2X6 sq. mm earth wire P/Mtr 25.00 813.00 20,325.00
j 1.14.10 4X10sq.mm+2X6 sq. mm earth wire P/Mtr 25.00 1,078.00 26,950.00
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including
connections but excluding modular plate etc. as required.
c 1.24.4 3 pin 5/6 A socket outlet Each 10.00 136.00 1,360.00
d 1.24.5 6 pin 15/16 A socket outlet Each 10.00 219.00 2,190.00
e 1.24.7 TV antenna socket outlet Each 1.00 168.00 168.00
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc. as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
13.38 1.31 including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections Each 20.00 545.00 10,900.00
etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,
13.39 1.32 including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, Each 25.00 659.00 16,475.00
connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed
plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained
metal cover for the socket out let and complete with connections, testing and commissioning etc. as
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including
13.41 1.2 painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit as required.
Digitally signed by AMIT
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in
13.42 1.21 surface/recess including cutting the wall and making good the same in case of recessed conduit as
13.43 8.3 LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt)
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round
/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and
construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge
protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified
Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life
time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard
Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/
Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that
LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body
including trim .
13.44 8.8 LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and
construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge
protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified
Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K /
5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power
consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all
respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135
lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be
submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction temperature shall not rise above
Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Digitally signed by AMIT
Supply, Installation, Testing & Commissioning of 1000 mm length X 35mm Width X 39mm Height(3000K)
Linear Wall Washer with Non-integral driver & completely made in India luminaire.Luminaire must use
Double LED of Chip. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey.
The complete luminaire has IP66 & IK07 protection and it comprises of high purity integrated poly
carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall
have wattage 48W and shall deliver 2640 lumens. Beam angle of the Luminaire shall be 11/15deg .Fixture
13.45 shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC. The luminaire shall nos 30.00 27,500.00 8,25,000.00
have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same
brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful
bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical
bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand
name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be
Made in India. Luminare, Driver and controller should be with same make.
Supply, Installation, Testing & Commissioning of 100mm Dia X 128mm Width X 260 mm Height- 2 X12W, Wall
Up - Down Light 3000K with Integral driver & completely made in India luminaire. The luminaire’s shall be
made of Die cast aluminum with Pure polyester powder coated housing. Optical compartment is sealed
with toughened glass using Silicon gasket ensuring IP65 & IK06 protection and lifelong performance.The
LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 2 X
12W and shall deliver 2 X 1200 lumens. Beam angle of the Luminaire shall be 29/60deg. Fixture shall
operating temperature range of 0°C to 45°C. Input Voltage Range of 140 - 280V AC. 2 stage Constant
current driver with Inbuilt 3kV surge protection. The luminaire shall have declared life of 50,000 burning
hours at L70. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must
have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL
accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance
issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed /
engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver
and controller should be with same make.
Supply, Installation, Testing & Commissioning of 115 mm Dia 2700K Bush Light with Integral driver &
completely made in India luminaire. The luminaire’s shall be made of Die cast aluminum with Pure
polyester powder coated housing. Optical compartment is sealed Reflector with toughened glass using
Silicon gasket ensuring IP67 & IK07 protection and lifelong performance.The LEDs shall have minimum CRI
≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 8W and shall deliver 640 lumens.
Beam angle of the Luminaire shall be 36 deg .Fixture shall operating temperature range of 0°C to 45°C.
13.47 Input Voltage Range of 100 - 270V AC. 2 stage Constant current driver with Inbuilt 3kV surge protection. nos 40.00 5,350.00 2,14,000.00
The luminaire shall have declared life of 50,000 burning hours at L70. Luminaire and Driver must be made in
India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct
LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer
along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for
LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and
Driver should be Made in India. Luminare, Driver and controller should be with same make.
Digitally signed by AMIT
Supply of 45W LED Decorative Post Top type luminaire with System efficacy of 85 lm/W (3800 lumens),
suitable for external poles of dia. 65mm to 75mm. Luminaire shall be made up of pure polyster power
coated RAL7021 pressure die cast Aluminium housing with Polycarbonate Fresnel lens for symmetrical or
street optics of same make. All external hardwaremust be of SS304 grade. LM 80-08 compliant LEDs of
EMC/ceramic package from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul
should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and
certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK07
protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum
current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used
should be with CCT of 3000 K, CRI of Minimum 70 and SDCM <5. LEDs must be driven at max 70% of the
rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED
mounting.LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 150-
300V AC. Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total
harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light fixture should have Dark
Sky Certification to avoid sky glow and light pollution. Manufacturer shall have inhouse lab approved by
NABL or ministry of science of govt of India. LM79 and LM80 reports need to be submitted from a NABL/UL
accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect
Supply of 214mm Dia X 80 mm Height 3000K LED fountain light with Non- Integral driver & completely made
in India luminaire. The luminaire’s shall be made of Hard Chrome plated molding stainless steel. The
complete luminaire has IP68 & IK08 protection for under water protection and it comprises of high purity
integrated poly carbonate Lens with tempered glass.The LEDs shall have minimum CRI ≥70 (White LED) &
shall have SDCM≤5. The luminaire shall have wattage 18W and shall deliver 1080 lumens. Beam angle of
the Luminaire shall be 15/30/60 deg .Fixture shall operating temperature range of 0°C to 45°C. Input
13.49 Voltage Range of 24V DC, Integrated DMX Decoder, No need to additional external decoder. The nos 10.00 20,555.00 2,05,550.00
luminaire shall have declared life of 50,000 burning hours at L70. Luminaire and Driver must be made in
India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct
LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer
along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for
LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and
Driver should be Made in India. Luminare, Driver and controller should be with same make.
Supply of Isolated, constant Voltage type 240 W LED Driver enclosure in Extruded Aluminium metal
enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP66
Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be
13.50 greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and nos 20.00 9,890.00 1,97,800.00
440V withstand for 8 hours minimum & sould have large operating input voltage range of 140V to 300V
AC(nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output
short circuit, over voltage protection, Thermal Shutdown protection.
13.51 Supply of IP 67 S - connector nos 30.00 990.00 29,700.00
13.52 Supply of IP 67 T - connector nos 20.00 990.00 19,800.00
13.53 2 MP IP IR Dome Camera
Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following
specifications, type of lens and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time
in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High
Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's
with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to
1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation,
Multi zone Privacy Masking, HLC, Digital Watermarking.
Digitally signed by AMIT
3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC,
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30
fps,Sub streams minimum: 720P@25/30 fps).
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client
software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs,
account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.
9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should
be supplied with minimum 128GB memory Card.
10) Recording Management: Format SD, overwrite, storage management, video to NAS device
11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP,
SSL, DHCP, SMTP, RTSPS, unicast
13) System Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter)
and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.
17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
2MP @ 25/30fps@1080P (1920×1080) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal
Motorized lens.
13.54 2 MP IP IR Outdoor Bullet Camera
Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having
following specifications and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time
in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High
Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR
LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to
1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation,
Multi zone Privacy Masking, HLC, Digital Watermarking.
3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC,
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30
fps Sub streams minimum: 720P@25/30 fps).
Digitally signed by AMIT
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client
software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs,
account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.
9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should
be supplied with minimum 128GB memory Card.
10) Recording Management: Format SD, overwrite, storage management, video to NAS device,
11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP,
SSL, DHCP, SMTP, RTSPS, unicast,
13) System Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter)
and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.
17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better
Varifocal Motorized lens.
13.55 Network Video Recorder (NVR)
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with
camera licenses to record for all channels having specifications and features etc as mentioned below :
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per
NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or
more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.
2) NVR should support video compressions : H.265 or better, H.264, MJPEG.
3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM,
G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port
7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output
devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for
power failure, HDD failure, vandalism, tempring, network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm
Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud
for remote monitoring without any public IP need.
13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power
Digitally signed by AMIT
15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)
16) The VMS application shall support all the features & functionalities of the offered cameras.
17) VMS should consist Licenses for all channels to record Cameras with General, motion detection,
intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no
dependency of VMS licenses by binding with the MAC address of the cameras to achieve the
18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android
and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.
19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address
for remote monitoring over the Internet.
20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode
21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF
22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring
page to view the alert details. The snapshot function is supported on monitoring and playback page
23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is
created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email
address shall be configured to receive any combination of critical, warning, or informational messages or
alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and
a list of camera that is configured to record upon alarm
24) It should have Web and GUI interface.
25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, -
Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection
26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of
Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add
Name, gender, birthday, address, credential type, credential No., countries & regions and state to each
27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions,
face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.
28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle
model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.
29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR
alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and
tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP
Conflict and abnormal behavior of fan, cybersecurity exception
30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer,
logs, presets and email.
31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall
Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,
Violence Detection.
32) Smart playback function: Should support smart search for the selected area in the video and smart
playback to improve the playback efficiency
33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera
34) Analytics by NVR: Perimeter protection and face recognation
32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd
screen: 1/4/8/9/16
Hard Disk Drive
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with
13.56 40.12 upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface,
BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
Supply Installation Testing & Commissioning of 43 inch Full HD LED monitor including wall mount brackets/
clamps/ desk mounting stand.
Digitally signed by AMIT
Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate
of color as per site requirement, should have ETL/UL verification program certificate for compliance with
ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility
and interoperability etc. complete as required.
Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular
13.59 39.16 plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- Nos. 28.00 9.00 252.00
26 AWG stranded wires etc. complete as required.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in
existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL
13.60 39.17 verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the
range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable
Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height
13.61 39.11 with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL Nos 2.00 5,278.00 10,556.00
verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
a 39.13.1 Copper Patch Cords of length 1m (3ft) Nos. 28.00 173.00 4,844.00
b 39.13.2 Copper Patch Cords of length 3m (10ft) Nos. 28.00 405.00 11,340.00
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber
should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC
60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated
Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to
+50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at
Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber
should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding
Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and
PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as
39.19.1 Single Mode 6 Core Optical fiber cable RMT 400.00 64.00 25,600.00
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having
high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm
13.64 39.22 with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature Each 4.00 705.00 2,820.00
7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage
Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for
jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple
configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools
13.65 39.21 built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered
fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single /
Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap
tube etc complete as required.
Digitally signed by AMIT
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main
Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail
of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling
fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front
door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated
door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power
distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number,
etc. complete as required.
Supplying, Installation, Testing & Commissioning of Type 1 IP Phone having 2 VoIP account, 120 x40 DOT
13.67 38.3 matrix screen with backlight, Full HD duplex speaker phone, IPV6, Gigabit Etherent, PoE etc. complete as each 3.00 11,698.00 35,094.00
Supplying, Installation, Testing & Commissioning of Analog phones having standard feautres like 16 digit
LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required.
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored
telephone cable in the existing surface/ recessed steel/ PVC Conduit etc. complete as required.
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor,
unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network
Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit
Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having
Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table.
Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP,
MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping
V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3,
13.71 39.3 UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP
Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS :
WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP
Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp,
802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet
ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on
Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as
24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting
802.3at PoE+ min.
Supply, installation testing and commisioning of 10 pair telephone tag block complete in all respects as
per approval of engineer-in-charge.
Total ELECTRICAL 40,86,264.28 40,77,058.00
CASSETTE TYPE SPLIT UNITS
Digitally signed by AMIT
Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete
with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt
drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper
Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr
(IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system
shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of
14.1 32.4 following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM)
warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver
100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be
submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as
per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute
(CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer
(OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
Inverter Type- Cooling only
a 32.4.1 1.5 TR with 5 Star BEE Rating each 4.00 77,417.00 3,09,668.00
b 32.4.3 2.5 TR with 5 Star BEE Rating each 1.00 1,18,123.00 1,18,123.00
Total HVAC 4,27,791.00 0.00
GRAND TOTAL 7,51,12,913.72
GRAND TOTAL 7,51,12,913.72
Digitally signed by AMIT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT UPSC.pdf
Tender Document
BOQ.pdf
Tender Document
Scc upsc.pdf
Tender Document
Integrtiy Pact.pdf
Tender Document
Technical circular upto 33 amendment.pdf
Tender Document
updated forms.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
GCC 2026.pdf
Tender Document
List of make UPSC_compressed.pdf
Tender Document
Tender Drawings.pdf
Tender Document
corrigendum-5359-corrigendum-i.pdf
pdf • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .