| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹48.2 L+₹3.8 L (8.55%)Rejected-Finance H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹48.8 L+₹4.4 L (9.80%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹49.8 L+₹5.3 L (12.0%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹50.4 L+₹5.9 L (13.4%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 Aug 2021, 6:00 pmClosed
GE West Ferozepur Cantt
GE West Ferozepur Cantt
CERTAIN SPECIAL REPAIR TO BLDG NO P 29 SINGLE OFFR ACCN IN SITE I OF UNIT AE AND OTHER SANCTIONED WORKS UNDER WEST FEROZEPUR CANTT
2021_MES_450485_1
802021/GE-50/E8
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE West Ferozepur Cantt
₹70,000
25 Aug 2021
7 Jul 2021
6 Aug 2021
7 Jul 2021
4 Aug 2021
27 Jul 2021
Amount
Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, shelves, over head tank and similar suspended work and removing debris outside MD land complete all as directed by E-in-charge.
Demolition of PCC of any description and in any position as in not otherwise specifically provided for
Demolition of brick work built in cement Mortar
Dismantling floor, hearth or wall tiling including cement mortar beding (but not backing),removing serviceable tiles to store and rubbish off the premises
Dismantling of Brick tiles or terracing tiles, single layer on roof
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof)
Mud phuska, 80mm thick average, consolidated thickness, on flat roofs including 25 mm thick mud plaster complete all as specified.
M&L for 10 mm thick screed plaster in cement mortar 1:4 finished even and smooth without using extra cement on top of roof complete all as specified and directed.
A tack coat of industrial bitumen 85/25 @ 1.20 Kg per square metre over a coat of bitumen primer @ 0.30 litre per square metre including preparation of roof surfaces complete all as specified.
150 mic popy film including preparation of roof surfaces complete all as specified.
M&L for 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5 % of crude oil by weight of cement on mud phuska and pointed flush as work proceeds complete all as specified and directed.
M&L except tiles for 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5 % of crude oil by weight of cement on mud phuska and pointed flush as work proceeds complete all as specified and directed. Note :- Old brick tiles retreived by dismantling of treatment vide item No 5 above to be reused.
Flush pointing to roof tiles in cement mortar (1:3) tiles including racking out joints complete all as specified.
Removing mud phuska /soil material exc. 250 m but n exc. 500 m and depositing where directed
M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or etc., and making good, cutting not exc 10 cm girth
Brushing neat cement slurry with 3 kg of cement per square metre
M&L 40 mm thick cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in slope correction layer over RCC slab finished without using extra cement complete all as specified and as directed.
M&L 10 mm thick screed bed or bedding layer of mortar in CM(1:4) with water proofing compound @2% by weight of cement or as per manufacturer instructions will be on surface to have a smooth surface for laying of water proofing membrane. Note: WPC shall be measured and paid separately)
Polymer modified bituminous membrane with sand witched polythene film/non woven polyster reinforcement /polymeric water proofing membrane 3Kg/sqm plastifelt/hyperplas /multiplas / shivam or equivalent ) laid over hot blown grade85/25@ 1.2kg/Sqm (i.e roof slab cleaned throughly to to remove all loose particle dust/dirt particle ) shall be laid over entire roof surface and on verticle surface up to grooves ( or as per manufacturers recommendation) with over laps of 100mm The over lap shall be sealed by flames or as per manufacturer instruction.Hot blown bitumen grade 85/25 @1.2kg/Sqm applied over the membrane should be compatible with membrane all as recommendation manufacturers and all as specified and directed.
M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, with grey cement and no pigment laid over 15 mm thick screed in CM (1:6) mixed with water proofing compound ,joints grouted and flush pointed in CM (1:3) mixed with 5% of crude oil by weigt of cement complete all as specified.
Preparation of roof surface and apply one coat of bituminous aluminium [email protected] Kg/Sqm applied on treated bituminous membrane complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls etc.. including raking out joints, hackinng for key , scrubbinng down with water , etc..
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required
Taking down existing chowkats or frames , without taking out shutters ,from the frame , n exc 1.5 SqM
Taking down existing chowkats or frames , without taking out shutters ,from the frame , exc 1.5 SqM but not exc 4 SqM each,
Taking down shutters of any description n exc 1 sqm each complete all as specified and directed.
Taking down shutters of any description opening exc 1 sqm and not exc 2 sqm each complete all as specified and directed.
Taking down shutters of any description and refixing in the same opening exc 1 sqm and not exc 2 sqm each complete all as specified and directed.
Taking up or down 25mm steel tubing and connections including cleeaning for refixing or removal to store complete all as directed.
Taking up or down 20mm steel tubing and connections including cleeaning for refixing or removal to store complete all as directed.
Taking up or down 15mm steel tubing and connections including cleeaning for refixing or removal to store complete all as directed.
M/L RCC 1:1.5:3 type B1 using 20mm graded aggregate as in Precast cover slab , shelves and similar articles and setting in mortarcomplete with joints to match complete all as directed.
M/L TMT bars 10mm dia and over cut to length bent to shape required including cranking and bending etc and binding with MS wire (annelaed) not less than 0.9mm dia or securing with clips..
M/L TMT bars 5 mm dia and over and upto 10 mm dia ,as in stirrups cut to length bent to shape etc including cranking and bending and binding with MS wire not less than 0.9mm dia.
M&L for Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in plinth protection, 50mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and as specified.
M & L PCC 1:5:10 type E-2 (40mm graded aggt) as in foundation filling & mass concrete
M&L Cement concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in benching, kerbs, mud stop, rounded or chamfered on edges including form work complete all as specified and directed.
M&L plain cement concrete type D2 1:4:8(40mm graded aggregate) 75mm thick laid in sub base for floor finishes .
M&L Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in floor topping, 40 mm thick, surfaces finished even and smooth without using extra cement complete all as specified.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors as in floor set and jointed in neat cement slurry over and including 15mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified.
M&L 15 mm thick CM (1:4) as in horizontal and vertical surface of sunken floor portion and mix with SIKA/FORSOC (SBR) mix with in the ratio of 4 ltr with one bag cement and all as specified.
M&L 30 mm thick cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in flooring for sub base in sunken floor finish mixing with integral water proofing compound complete all as specified and as directed. Note: WPC will be measured and paid separately
M & L brick work with sub class ‘B’ old sized bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6
All as per item 43 above but using Old Unserviceable bricks retrieved from demolition including cleaning and removal of mortar from Old Unserviceable bricks.
M/L rendering 15mm thick in CM 1:4 in on fair faces of brick work , finished even and smooth without using extra cement with WPC. Note : WPC will be measured and paid separately.
M/L rendering 15mm thick in CM 1:6 on fair faces of brick work , finished even and fair without using extra cement.
M/L rendering 10mm thick in CM 1:3 on fair faces of concrete finished even and fair in ceilings
M&L 10mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L 5mm thick in cement mortar (1:3) cement plastering to ceiling on concrete surfaces finished even and fair without using extra cement all as specified & directred.
Supply only integral water proofing compound .
M&L for preparation of newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
M&L for preparation of old surfaces of wall and applying one coat of white wash complete all as specified and directed
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying one coat of white wash complete all as specified and directed
M&L for Preparation of new plastered wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified.
M&L for complete removal of existing treatemnt and applying two coats of cement base paint on wall surfaces complete all as directed.
M&L for preparation of old surfaces of wall and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed
Supply and fixing of factory made box type window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter steel handle and with glazing bars dovetailedor welded and with one shop coat of zinc chromate primer complete all as directed
Supply and fixing of factory made steel ventilator side/top hung with glazing bars dovetailed or welded and with one shop coat of zink chromate primer complete all as specified and shown on Drawing No CEJZ/TD-1019/08 sheet 1/3 to 3/3.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads, in squares n.exc 0.50 Sqm in each pane complete all as specified.
S&F 3mm thick, Figured glass pin head type, with oil putty, in squares n.exc 0.50 Sqm complete all as specified.
Supply and fixing of factory made Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified.
All as per item No 64 but size of profile 125 mm X 60 mm, complete all as specified.
All as per item No 64 but size 75x50mm with single rebate.
S&F factory made 35mm thick second class hard wood plain framed panelled shutters (any number of panels ), with panels of timber flat on both sides (feather edge), or of veneered particle board medium density wood wood particle board with commericial face veneers and fitted to chowkats.
S&F factory made 35mm thick second class hard wood glazed and skelton shutters,open rebated and prepared to receive glass gauze,etc (without sash bars),edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) fitted to chowkat.
S & F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete as per manufacturer’s specification and drawing and as directed.
S & F factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of mild steel tubes for top & bottom rails, Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm with steel inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, fixing in the frame at site as per specification, drawing and as directed.
S& F Factory made 35mm thick 2nd class HQ Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S& F aluminium alloy ,anodized sliding door bolt with hasp and staple and fixing clips of sheet , cast or extruded section , and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed length of bolt 300 mm , fixed iin repairs
Cutting holes in brick wall buit in CM for fixing hold fats and making good dismantled portion in CM (1:3) or in cement concrete 1:2:4 type B-1 depth of embedded portion of hold fast measured from the face of jamb into wall exc half brick but n exc. One brick all as specified and directed.
S & F extruded aluminium anodised alloy handles, fabricated type, size of handle 150 mm,
S&F aluminium ,anodized 200mm long barrel tower bolts of extruded section,
All as per ser Item No 75 but 150mm in size
S & F 100 mm size butt hinges of medium weight cold rolled mild steel
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21 complete all as specified and directed
M & L for galvanised MS wire cloth for 0.56 mm nominal dia of wire & average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples etc fixed in repairs
S&F framed work such as grills, gratings etc.. With ends of bars shouldered and or riveted or forged into spikes , framed guard bars ,barred iron doors , ladders , framed balusters , walk ways , railings, frame work of water tanks and similar work conforming Fe 290 , Gde -E -165
M&L Cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of steel chowkhats including necessary form work complete all as specified.
S&F Factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with &Without glazing bars dovetailed or welded including gaurd bar and one shop coat of zinc chromate primer complete all as specified .
S&F Powder coated of ( any colour ) aluminium window , ventilator etc fixed / sliding or pull and push type in shutter frames or shutters with two/three track sliding aluminium frame of Jindal /Hindalco (or) Equivalent make of approved size, including necessary joining cleats, glazing clips,powder coated aluminium snap beading, screws, including necessary anodised aluminium fittings like handle/Tower bolt/hingess etc complete all as specified as per manufacturers instructions. Note: EPDM Rubber beading/gasket measured and paid seperatley.
S&F EPDM Rubber beading around glass in aluminium windows /ventilator shutters.
S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed.
S&F 4 lever aluminium mortice lock,vertical type size 100 mm complete.
S & F Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg of aluminium (die cost body) and fixed
S&F 4.8 mm thick sheet glass ordinary quality along with EPDM rubber all around the glass edges exc 0.5 sqm in each pane and fixed into aluminum frame work complete
S&F Aluminium (cast type) anodized, bow handle 150mm size fixed with screws complete all as specified and directed.
All as per srl item N0 89 here in before but 100 mm size.
S&F 12 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination white lamination,fixed with screws to alluminum frame work complete all as specified and directed by Engineer in Charge
S&F 14-16 mm solid PVC board plain colour fixed with screws or adhesive with complete accessories as in shutters complete all as specified and directed by Engr-In-Charge. Make: Rajshree,Echon, or equivalent as approved by GE.
S&F 16-18 mm solid PVC board plain colour fixed with screws or adhesive with complete accessories as in shutters complete all as specified and directed by Engr-In-Charge. Make: Rajshree,Echon, or equivalent as approved by GE.
S&F PTMT tower bolts, 200 mm long and fixed with steel screws complete all as specified.
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified.
PTMT door handle, 125 mm long and fixed with steel screws complete all as specified.
S &F in repair to 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads, in squares n.exc 0.50 Sqm incl. incl hacking out Old Unserviceable broken glass and putty/beading complete all as specified.
S &F in repair Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified as in repair.
Dismantling of steel work including doors ,gates but excluding framed truss etc complete all as spd and directed
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Welding in repairs n. exc 2.5cm in length and thickness n exc 6 mm complete all as specified.
S&F Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
S & F in rep of Gypsum Board 12mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm , Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl aluminium anodised snap grid frame 605X605 mm for false ceiling incl hanging arrangement complete all as specified and directed by Engineer in Charge.
Designing,fabricating,installing and fixing in position 3.00to to 4.00 mm thick aluminium composite pannels facing at walls/Circular column faces, coil coated,with kynar 500 based PVDF/lumiflon based fluoropolymer resin coating of approved colour and shade on one face and ploymer(service) coating on other face as specified using stainless steel screws,nuts,bolts,washers,cleats, weather silicon sealant ,backer rod , black silicon grooving etc complete all as specified and directed. Note: The rates of Scaffolding is deemed to be included in the quoted rate.
S&F 5 mm thick coloured of any selecetd design hollow PVC wall cladding strips interlocked to each other fitted to wall including PVC 'U' shapes at top/ bottom and PVC angles at windows/door openings all as per manufacturer’s fixing instructions complete all as specified and directed by Engr-in-Charge.
M&L glazed tiles digital/designer coloured ceramic tiles 300x450x7mm thick in vertical surfaces ( including scaffolding)such as wall lining set and jointed in neat cement slurry pointed in coloured cement to match including 15 mm thick plastering in CM 1:4, design Colour and patten as approved by GE complete all as specified and directed. Note: The rates of Scaffolding is deemed to be included in the quoted rate.
M&L for providing cement concrete type B1 1:2:4 (20mm graded aggregate) as copings, kneelers, apex stones, bed plates, kerbs, edge of paver block , water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed
M/L Non skid ceramic coloured tiles 7-8 mm th (square or rectangular)area of eacch tile exc 0.06 SM but not exc 0.11 SM in floors etc.. Set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 300 X 200X 7 mm th set and jonnted in cement slurry and pointed in white or colour X 7 mm th set and jonnted in cement slurry and pointed in white or colour cement to match including 10mm thick back coat in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles, coloured (light colour as approved), of size 300x200/ 300x450 of 7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.
M&L Terrazzo tiles 20cm x 20 cm x 20mm thick, with size of chips upto 6 mm; set, jointed and pointed in neat cement slurry in floors,with grey cement and no pigment and cut and polished including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for polishing existing terrazzo tiles flooring complete all as specified and directed.
M & L for non skid coloured ceramic tiles of 7 to 8 mm thick , area of each tile exceeding 0.11 sq m but not exceeding 0.18Sq m in floors set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match over a screed layer of 15 mm thick in CM 1:6 complete all as specified and as directed.
M & L for non skid coloured ceramic tiles of 7 to 8 mm thick , area of each tile exceeding 0.11 sq m but not exceeding 0.18Sq m as in skerting/dado set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match and backing with 10 mm thick in CM 1:4 complete all as specified and as directed.
S/F of Glazed coloured and cereamic tiles in vertical surfaces 300X200X7mm / 450X300X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over backing coat 10mm thick in cement mortar 1:4 for laying skirting dados and vertical surfaces all as specified and directed
S&F Vitrified ceramic tiles 10mm thick (Square/rectangular)polished area of each tiles exc 0.36Sqm and not exceeding 0.42Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured (Light Shade)cement to match over 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes.
S&F Vitrified ceramic tiles 10mm thick (Square/rectangular) polished area of each tiles exc 0.36Sqm and not exceeding 0.42Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured (Dark Shade)cement to matchover 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes.
M&L for light shade Vitrified tile 10mm thick polished, area of tile n exc.0.36 sqm as in Skirting set and jointed in cement slurry over and including 15mm thick screed in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.
M & L Granite (of any type) tiles 16- 20mm thick machine cut, bedded andjointed with grey cement slurryand pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing with 15mm thick screed in cement mortar (1:4) complete all as specified.
M&L 25 mm thick for PCC Flooring using cement concrete 1:2:4 type B-0 using 12.50 mm graded aggregate as in levelling course in floor.
M&L 50mm thick PCC(1:2:4) type B1 (20mm graded stone aggregate as in plinth protection laid in alternative panels finished even and smooth without using extra cement.
S&F galvanised steel pipe medium grade 50mm bore as in rain water spout, projecting 15cm beyond the face of wall complete all as specified and directed.
S & F steel water tubes, 25mm diameter medium grade galvanized, with all fitting and fixed to walls and ceiling or laid in floors including necessary cutting through walls and making good with cement mortar .
All as per item no. 124 but fixing only 25 mm dia tube any grade to wall and ceiling or laying in floors
S & F steel water tubes, 20mm diameter medium grade galvanized, with all fitting and fixed to walls and ceiling or laid in floors including necessary cutting through walls and making good with cement mortar .
All as per item no. 126 but fixing only 20 mm dia tube any grade to wall and ceiling or laying in floors
S & F steel water tubes, 15mm diameter medium grade galvanized, with all fitting and fixed to walls and ceiling or laid in floors including necessary cutting through walls and making good with cement mortar .
S&F galvanised steel water tubes 15 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors including taking down corroded GI pipe complete all as specified and as directed by Engr-in-Charge.
S&F galvanised steel water tubes 20 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors including taking down corroded GI pipe complete all as specified and as directed by Engr-in-Charge.
Taking up or down 15 mm existing steel tubing and connections and re fixing Old Unserviceable steel tubing and connections in new or Old Unserviceable position complete to walls and ceiling or laid in floors complete including cleaning the steel tubing all as specified and as directed.
All as per item No. 131 here in before but 20mm dia.
S&F in rapir fancy type bib tap of Chromium plated, 15mm bore screwed down, screwed for iron pipe or for brass ferrule complete all as specified. .
S & F in repairs stop valve/angle cock fancy type of 15 mm dia cast copper alloy chromium plated screwed down, high pressure, with crutch or butter fly handle long shank and cup (concealed type) screwed both ends for iron pipes or for unions
S&F bib taps, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule complete all as specified.
S&F 15 mm stop cock cast copper alloy with crutch or butterflty handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated with fancy shank and cup complete all as specified.
S&F towel rail 600mm long fixed with and including chromium plated brass screws and wooden/plastic cleats (Min wt 190 gms)
S & F in repairs chromium plated Shower rose,with or without swivel joints any size including fixing to steel pipe or union 15 mm dia.
Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Make Prayag or equivalent)
M&L in repair for 100mm dia Cast iron Nahani trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc and fixed in repairs complete all as specified.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cisternand flush pipe fixing in repairs
S&F in repairs Vitreous china Squatting pan , "Orissa Pattern" size 580 X 440 mm , white with integeral foot rests ( excluding Flushing cisitern and flush pipes) fixed in repairs including concrete bedding with Traps ‘P’ or ‘S’ complete all as directed.
S& F Vitreous china wash down water closet pan ( pedestal pattern) white ( Excluding fixing bolts , flushing cistern and flush pipe all as specified.
S&F Wash hand basin, flat back 630x450mm vitreous china (white) including CP waste fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified.
S&F Wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size PVC waste pipe, angle iron/cast iron brackets of required size complete all as specified and directed.
M&L for special treatment of sunken portion of WCs and Bath room as per following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP/SIKA/plaster seal of STP Ltd or equivalent Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing of Dr Fixit Pidicrete for the sunken portion of toilets/bathrooms (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6:- All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia GI spout for draining the surplus water if any.
S & F in repairs PVC valve less symphonic action type flushing cistern low level with all internal fittings including flush pipe with bend , 450mm long PVC connection and connected to WC complete all as specified and directed.
Disconnecting existing tanks of Exc 250 and not exc 500LtrsCapacity ,setting aside (or lowering if required) forrepairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
S&F 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including fittings & dismantling existing water storage tank, complete all as specified.
S&Fin repair 1000 Ltrs capacity Rotational rotational moulded triple layered polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old UNSV water tanks and removing to store complete all as directed
S&F in repair 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S & F in repairs 20 mm dia ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule
S&F20mm bore PTMT ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified.
S & F CP toilet paper holder complete all as specified and directed by Engineer in Charge
S & F in repair to CP WHB mixer 15mm bore without popup waste system with 450mm long braided hoses Complete all as specified and directed by Engineer in Charge. Note:CQT-23167B(Make:Jaquar /Equivalent make)
S&F chromium plated fancy type15mm bore dia hot and cold mixer monolithic and head shower non telephonic type all as specified and directed.
S&F chromium plated fancy type15mm bore dia hot and cold sink mixer all as specified and directed. Note:-F2002511(Make:Cera/Equivalent))
S&F Health faucet (ABS Body) with 8mm dia 1.00 m long easy flexible tube chormium coated finish and wall hook all as specified and directed by Engineer-in-Charge.
S&F in repairs Health faucet (ABS Body) with 8mm dia 1.00 m long flexible tube(PVC /stainless steel coated) and wall hook all as specified and directed by Engineer-in-Charge. Make:Jaquar cat No: ALD-CHR-585; Cera Cat NO:F8030103,Prayag No:1871
S&F Soap dish of PTMT fixed to wall with steel screws anf PVC rawl plug complete all as specified.
S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc complete all as specified.
S&F Two Way brass CP Bibcock with wall flange50 to 65mm long(facilitate to fix the Halth faucet) (Make:Jaquar) CQTNO;23041/FLR 8041N) and Make: CERA catNo:F3002161 /F2002161 15 mm dia bore type with handle, screwed down, screwed for iron pipe or famale of quarter turn type complete all as specified.
Supply & fixed of pressure JET for EWC including PVC connection and CP fitting all as specified and directed.
S&F hot and cold wall mixer Non Telephonic /Non Over head shower type arrangement with connecting legs and wall flanges all as specified and directed by Engineer-In-Charge. Make:-Jaquar Cat No: FLR-5219 N; CERA Cat No:F2004405
White wash in two coat on Old plastered surfaces of wall including preparation of surfaces complete all as specified.
Preparation of Old plastered surfaces of ceiling & applying two coats of white wash complete all as specified & directed.
M&L for Preparation of newly plastered surfaces of walls & applying three coats of white wash complete all as specified.
M& L for preparation of newly plastered surface of ceiling and applying three coat of white wash complete all as specified and directed
M&L complete removal of existing treatment apply two coats of distempered surfaces over coat of primer surfaces and all as specified and directed.
Preparation of newly plastered surfaces of walls & applying two coats of distemper oil emulsion over one prime coat complete all as specified & directed.
M&L 32 mm bore high density polyethylene (HDPE) pipes of pressure rating 6 Kgf/sq.m laid in floor or walls
S&F 110 mm bore PVC (SWR) pipes single socked in any length with rubber ring joints fixed to wall and floor including taking out old broken / unserviceable pipe of any description including fittings complete.
S&F PVC (SWR) 110 mm bore bends of any radius
S&F PVC (SWR) 75 mm floor trap, plain with grating including jointing with solvent cement complete all as specified
Taking down eaves gutters and rainwater pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in treches or in floors
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed to walls icluding all fixing items such as brackets and distance pieces etc..,
S&F 75mm dia PVC (SWR) pipes single socketed in any in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes , complete all as specified.
S&F 75mm dia PVC (SWR) bends with access door bends any radius
S&F 110 mm dia PVC (SWR) bends with access door bends any radius
S&F 75mm dia branch piece single (Single Y)with access door equal or unequal
S&F 110mm dia branch piece single (Single Y) equal or unequal
S&F 110mm bore, PVC (SWR) branch piece, single (single T) equal or unequal with access door complete all as specified.
S&F 75mm dia Junction single (Single T) with access doorequal or unequal
S&F 110mm dia Junction single (Single T)with access door equal or unequal
S&F 75mm bore PVC (SWR) Vent Cowl
S&F 110 mm bore PVC (SWR) Vent Cowl
S&F cast iron soil, waste and vent pipes of 75 mm bore in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
All as per ser item No 194 but fixing only
S&F CI bends of 75 mm bore diminishing pieces or tapers including jointing with CM 1:3 and making good complete all as specified and directed
S&F 75mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
S&F cast iron soil, waste and vent pipes of 100 mm bore in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
All as per ser item No 198 above but fixing only
S&F CI bends of 100 mm bore diminishing pieces or tapers including jointing with CM 1:3 and making good complete all as specified and directed
S&F 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
S & F in repairs CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F CP soap dish holder complete all as specified and directed by Engineer-in-charge
M & L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces applying polymer modified mortar in CM 1:3 including mixing of polymer latex additives upto 60mm thickness (Chajjas fins, border etc) (i) Qty of ploymer to be used 15% by weight of the cement. (ii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces. (iii) To achieve required thickness repear this step after 24 hrs as required.(iv) Keep the surfaces moist using water forg for 5 to 7 days etc complete all as specified and as directed. (v) Rate shall be inclusive of all necessary scaffolding for building height up to 24 meters complete all as specified and directed by Engineer-in-CHarge. Make : - Epoxy bonding agent shall be Krishna, Dr Fixit, MC Bauchemie and M/s Cemistik, Sika or Equivalent as directed by Engineer-in-Charge
M&L for application of high build polymer modified to ceiling with cement mortar Plaster (1:3) with SBR @ 4 ltr per bag of cement applied as per manufacturer's instrutions.as in complete all as specified.
M&L for preparation of new wooden surafces of any description not otherwise described , over 10 cm width or girth , priming with a coat of pink primer and applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directeed by EIC
M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as directed.
Painting to new steel surfaces of any description, over 10cm width or girth two coats with synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified.
M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 m in depth for foundations etc and getting out in soft/loose soil complete all as specified and directed.
Returing, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soill, complete all as directed by Engr-in-Charge.
Removing excavated material as soil exc. 50 m and n.exc 250 m, depositing where directed at a level n.exc. 1.5m above the starting point, complete all as directed.
M&L precast kerb stone of size as specified with concrete mix 1:2:4 type B1 using 20 mm graded aggregate set in CM 1:4 complete all as specified and directed.
M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in foundation,filling and mass concrete complete all as specified and directed.
M&L for preparation of new concrete surfaces and applying two coats of synthetic enamel paint (ordinary tint) over a coat of primer coat as in kerbs stones and all other similar works as per approved patteren complete all as specified and directed.
Excavating over areas n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for broken bricks hardcore of gauge n. exc. 63 mm , deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layeres n.exc. 15 cm thick, spread, levelled and reammed including watering, complete all as directed by Engr-in- Charge.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 ( 40 mm graded aggregate) as in sub base to flooring and other similar works complete all as specified and directed.
M&L for sand filling under floors or in foundations or cable protection including watering and consolidation complete all as specified and directed.
M&L macine finished precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade laid over sand cushning with grey cement and no pigment all as specified and directed.
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) complete, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keetping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls , floors ,etc.
M &L Point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor, multi stranded of size 1.5 sqmm, single core, in and including existing rigid non-metallic PVC conealed conduit, with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing MS pressed steel / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire of size 1.5 sqmm unsheated stranded copper conductor with green PVC insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch.
(b) One Exhaust fan point controlled by one single pole one way switch.
(b) One socket outlet on the same board controlled by one single pole one way switch
(c) One 5 amps socket outlet independent controlled by one single pole 5 Amp switch.
All as per Item No 224 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 Sq mm PVC insulated copper conductor and 2.5 Sqmm copper conductor for continuous earthing complete.
Supply & Fixing Switch piano flush type single pole one way 5/6 Amp complete all as directed.
Supply & Fixing Switch piano flush type 15 amps, single pole one way duly ISI marked.
Supply & Fixing Socket outlet 5 pin , 5/6 Amps flush type ISI marked.
Supply & Fixing Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked.
Supply & Fixing bell push flush type 5 Amps duly ISI marked.
Supply & Fixing ceiling rose,PVC/Polycarbonate,isolated three terminals.
Supply & Fixing Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings.
Supply & Fixing Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings. Including 10W LED lamp
Supply & Fixing bell ding dong type AC 230 Volt single pole.
Supply & Fixing step type regulator Piano switch type ( 5 step) for ceiling fan 1200/1400 mm size 230 volts, 6 Amps.
S & F in repair Modular Switch one way 6 A, 1 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular Switch one way 16 A, 1 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular Socket,6A - 2/3 pin combined 2 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular Socket,6A16A - 2/3 pin combined 2 module complete all asper specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular white cover plate with frame, 3 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular white cover plate with frame, 4 modulecomplete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular white cover plate with frame, 6 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
S & F in repair Modular step type regulator,120 W - 2 module complete all as per specified and directed. Make - Anchor/Havells/Legrand
Supply & Fixing LED tube light fitting 18 Watts,4 feet long decorative ultra slim linear LED lighting fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part no. LCTL-18-CDL of Crompton or LHEXBXPNIW020 of Havells or equivalent Bajaj/Phillips
Supply and Fixing LED 2 feet X 2 feet,36 watts, 230 volts recessed mounting luminaires, complete with all accessories pre-wired and including connecting up with two core 1.5 sqmm copper conductor cable complete. LCTLRN-36FO-CDL of Crompton or equivalent Bajaj/Phillips/Havells
Supply and fixing LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm
Supply and fix exhaust fans steel body AC single phase 230 V, of size 380 mm sweep with , blades and frame and louver
Supply & Fixing sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series TPN DBs (Vertical type)fitted with ABS frame and 415 volts 200 Amps rated enameled bus bar 4 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified
Supply & Fixing sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 way dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
All as per Item No 254 but SPN DB 4 way
S&F Sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps complete all as directed.
Supply & Fixing MCCB 100 Amps, 415 volts, 16 KA, 4 Pole complete all as specified.
Supply & Fixing MCB, Single pole 240 V,6 - 32 Amps 10 KA 'B Series.
Supply & Fixing MCB, Single Pole and neutral 240 V, 32 Amps 10 KA 'B' series.
M & L for sub main wiring with two single core PVC insulated FRLS cable with Copper conductor unsheathed cable of size 2 x 6 sqmm drawn through in and including PVC Concealed with 1 x 6 sqmm PVC insulated copper conductor single core for continuous earthing complete including PVC conduit 25 mm dia ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0 Sqmm and one run of 6.0 Sqmm PVC insulated copper conductor single core,one run of PVC conduit shall be measured as single run)
Supply & Fix sub main wiring of 4 Sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor with earth wire of 2.5 Sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including PVC conduit pipe 25 sq mm dia all as specified and directed. Note:-Two single core 4 Sqmm cable and one single core 2.5 sqmm cable for earth wire and including conduit pipe 25 mm dia shall measured as one length).
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate, excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009)
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core.
M & L sub class B bricks locally available of size 22x11x7.5 cm laid dry width wise acrose the line of cable in trenches for protection of UG cable
M&L Mild steel galvanised iron pipe light grade (ISI marked) 40mm bore for passing of cable laid in trenches fixed to walls laid under floors, roads including all fittings i.e MS clamps nuts & bolts etc as required all as specified.
Karan Engineers
shivam builders
M/S Yashpaul Gulati
M/S Pee Kay Builders
M/s Harkesh Kumar Bansal
S.R. Kaura and Company
M/S CHAWLA CONSTRUCTION COMPANY
Supreme Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .